Records from 1999 to 2020. Most recent: inspection, 30 January 2020.
Inspection history · 47
30 January 2020
Administrative Inspection
Administrative · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 6899696
7 June 2017
Administrative Inspection
Administrative · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6168231
5 April 2016
Administrative Inspection
Administrative · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 5876254
10 September 2015
Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 5721478
27 May 2014
Cargo Tank Internal · Internal Structural Exam · Hull Examination
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 4866342
25 January 2012
Administrative Inspection · MARPOL Annex VI Survey
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 4257261
23 September 2011
COI Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 4152481
7 July 2011
Type not recorded
No type recorded · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 4073157
20 September 2010
Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3851955
12 March 2010
Damage Survey
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3695841
11 March 2010
Type not recorded
No type recorded · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3896732
25 January 2010
Administrative Inspection
Administrative · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3669728
6 July 2009
Re-Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3601979
22 July 2008
Re-Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3275618
1 May 2008
Administrative Inspection
Administrative · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3196652
9 July 2007
Re-Inspection · Deficiency Check
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2991323
1 May 2007
In-Service Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2919787
21 September 2006
Drydock Extension
Administrative · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2783627
6 July 2006
COI Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2702734
14 December 2005
Re-Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2552058
14 November 2005
Administrative Inspection
Administrative · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 2534161
26 September 2005
Security Plan Amendment Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2501714
6 April 2005
Type not recorded
No type recorded · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2327507
16 February 2005
Security Plan Amendment Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2294013
27 October 2004
MTSA/ISPS Verification · Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 2229602
29 July 2004
Internal Structural Exam · Hull Examination · Cargo Tank Internal
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2149335
3 November 2003
Security Plan Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 1979606
10 September 2003
Deficiency Check
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1901624
5 September 2003
Administrative Inspection
Administrative · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1945814
2 September 2003
Re-Inspection
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1894418
21 February 2003
Administrative Inspection
Administrative · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 1747625
10 September 2002
Annual Inspection
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1671220
26 November 2001
Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1450699
26 July 2001
COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1373555
18 May 2001
Damage Survey
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1064194
16 May 2001
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 160226
29 August 2000
Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 822372
26 July 2000
Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1458790
25 January 2000
Damage Survey
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1045437
21 January 2000
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 108285
20 January 2000
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 6094
19 October 1999
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1124786
27 September 1999
Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1342893
2 September 1999
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1120732
23 August 1999
Damage Survey · Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 779168
22 August 1999
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 53298
26 July 1999
Initial Construction-Excluding Oversight · Initial Certification · Inclining Experiment
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1369304
Construction/Loadline › Hull › Side Shell
Issued 12 March 2010
Resolved
Vessel was involved in a collision with the M/V [name withheld] that puntured the side shell of the vessel in the vicinity of the messdeck. ABS attended vessel during repairs and witnessed testing after repairs were completed. Vessel cleared to sail by ABS.
Condition: Damaged By Earlier Event
Action required: 17 - Rectify deficiencies prior to departure
Resolved 12 March 2010
Construction/Loadline › Structures › Machinery Space Opening
Issued 11 July 2007
Resolved
DEMONSTRATE PROPER OPERATION OF ENGINE ROOM CLOSURE.
Action required: 17 - Rectify deficiencies prior to departure
Due 9 August 2007
Resolved 11 July 2007
Resolution: COMPLETED
Construction/Loadline › Structures › Door
Issued 9 July 2007
Resolved
INSTALL CORRECT SIZE FIRE DOOR ON MAIN DECK BATHROOM AT NEXT DRYDOCK
Action required: 705 - Other - as specified
Due 9 August 2008
Resolved 22 July 2008
Fire Fighting › Structural Fire Protection - General › Cooking Area
Issued 9 July 2007
Resolved
PROVIDE AND INSTALL METAL COVER FOR DEEP FAT FRYER.
Action required: 705 - Other - as specified
Due 9 August 2007
Resolved 10 July 2007
Resolution: COMPLETED
Construction/Loadline › Structures › Door
Issued 9 July 2007
Resolved
RENEW FREEZER DOOR GASKET.
Action required: 705 - Other - as specified
Due 9 August 2007
Resolved 10 July 2007
Resolution: COMPLETED
Accommodation/Occupational Safety › Occupational Safety › Tripping/Falling Hazard
Issued 9 July 2007
Resolved
RENEW TWO SAFETY HARNESSES, INSPECT MONTHLY AND LOG MONTHLY.
Action required: 705 - Other - as specified
Due 9 August 2007
Resolved 10 July 2007
Resolution: COMPLETED
Electrical › Lighting (service) › Lighting Fixture
Issued 9 July 2007
Resolved
DEMONSTRATE PROPER OPERATION OF GENERAL ALARM LIGHT IN AFT STEERING STATION.
Action required: 17 - Rectify deficiencies prior to departure
Due 9 August 2007
Resolved 10 July 2007
Resolution: COMPLETED
Electrical › Lighting (emergency) › Lighting Fixture
Issued 9 July 2007
Resolved
DEMONSTRATE PROPER OPERATION OF ENGINE ALARM LIGHTS ON FINAL POWER.
Action required: 705 - Other - as specified
Due 9 August 2007
Resolved 10 July 2007
Resolution: COMPLETED
Navigation › Piloting/Steering › Magnetic Compass
Issued 15 December 2005
Resolved
Repair/replace magnetic compass and renew deviation table.
Condition: Unknown
Due 19 December 2005
Resolved 4 January 2006
Resolution: Repaired compass and provided updated deviation table.
Engineering › Pressure Vessel › Relief Valve
Issued 27 October 2004
Resolved
Complete annual testing of all relief valves on vsl.
Due 20 November 2004
Resolved 27 October 2004
Construction/Loadline › Hull › Hull Plating
Issued 29 July 2004
Resolved
Crop and renew as original non-tight bulk head in port aft peak.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 29 July 2004
Resolution: Inserted and verified by ABS.
Deck/Cargo › Holds/Tanks › Liquid Level Gaging
Issued 29 July 2004
Resolved
Reweld broken sounding tubes as necessary
Action required: 17 - Rectify deficiencies prior to departure
Resolved 29 July 2004
Resolution: Repairs completed.
Documentation › Certificates/Documents
Issued 10 September 2003
Resolved
Document was expired LEGACY COMPONENT DESC: Cargo Ship Safety Construction Certificate
Action required: 705 - Other - as specified
Resolved 10 September 2003
Resolution: Document was issued by MSU Galveston
Documentation › Certificates/Documents
Issued 10 September 2003
Resolved
Document was expired LEGACY COMPONENT DESC: IOPP Certificate
Action required: 705 - Other - as specified
Resolved 10 September 2003
Resolution: Document was issued by MSU Galveston
Electrical › Electric Generation Source (emergency)
Issued 10 September 2002
Resolved
Restore overspeed safety function on emergency generator. LEGACY COMPONENT DESC: Overspeed Safety Function
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Resolved 11 September 2002
Electrical › Electric Generation Source (emergency)
Issued 10 September 2002
Resolved
Correct out of balance condition of emergency generator cooling fan and the cracked belt guard cover mount. LEGACY COMPONENT DESC: Cooling Fan
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Resolved 11 September 2002
Engineering › Compressed Air System (control)
Issued 10 September 2002
Resolved
Replace faulty hose on stbd air compressor. LEGACY COMPONENT DESC: Hose
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 11 September 2002
Documentation › Manuals/Policy Documentation
Issued 10 September 2002
Resolved
Produce SOLAS Tarining Manual. LEGACY COMPONENT DESC: Training Manual (lifesaving)
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 11 September 2002
Navigation › Piloting/Steering
Issued 10 September 2002
Resolved
Make correction to marine charts. LEGACY COMPONENT DESC: Marine Charts
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 11 September 2002
Lifesaving › Line-Throwing Appliances
Issued 10 September 2002
Resolved
Replace expired charges for line throwing gun. LEGACY COMPONENT DESC: Charges
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 11 September 2002
Navigation
Issued 26 July 2000
Resolved
DEMONSTRATE PROPER OPERATION OF DEPTH RECORDING DEVICE IAW 33CFR164.35.
Condition: Unknown
Due 26 September 2000
Resolved 29 August 2000
Construction/Loadline
Issued 23 August 1999
Resolved
MAKE PERMENANT REPAIRS TO AREA DAMAGED BY ANCHOR IWO OF Z-DRIVE ROOM AFT NEAR THE CENTERLINE. REPAIRS SHALL BE MADE TO THE SATISFACTION OF ATTENDING MARINE INSPECTOR.
Condition: Unknown
Due 24 August 1999
Resolved 24 August 1999
Fire Fighting
Issued 26 July 1999
Resolved
Relocate emergency generator radiator cover from behind 02-03 deck access ladder.
Condition: Unknown
Due 26 July 1999
Resolved 26 July 1999
Lifesaving
Issued 26 July 1999
Resolved
Prove proper operation of engineer call alarm.
Condition: Unknown
Due 26 July 1999
Resolved 26 July 1999
Engineering
Issued 26 July 1999
Resolved
Loss of 24vdc to Caterpillar electrical engine control results in loss of shutdowns, no low lube oil trip, overspeed or emegency/local shutdowns. Install audible/visual alarm indicating loss of 24vdc.
Condition: Unknown
Due 26 July 1999
Resolved 26 July 1999
Engineering
Issued 26 July 1999
Resolved
Prove proper operation of start air pressure gauge in pilot house.
Condition: Unknown
Due 26 July 1999
Resolved 26 July 1999
Deck/Cargo
Issued 26 July 1999
Resolved
Install shut off valves at each filling end on following fill pipes:_x001C_ misc oil, anchor windlass oil 1 & 2, Cat oil and M/E oil.
Condition: Unknown
Due 26 July 1999
Resolved 26 July 1999
Fire Fighting
Issued 26 July 1999
Resolved
Provide second 5 gallons of fire fighting foam.
Condition: Unknown
Due 26 July 1999
Resolved 7 August 1999