Records from 2000 to 2022. Most recent: inspection, 17 November 2022.
Documentation record
Registered dimensions (L × B × D)183.1 ft × 56.0 ft × 18.0 ft
Registered tonnagegross 1,489 / net 446
ITC dimensions (L × B × D)183.1 ft × 56.0 ft × 18.0 ft
ITC tonnagegross 1,489 / net 446
BuilderHALTER MARINE GROUP INC · MOSS POINT, MS, UNITED STATES · built 2000
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portNEW YORK, NY
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 12 June 2026 · expires 31 July 2027
Service, as the file records itOffshore Supply Vessel
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it1489 - Convention (Subpart B), Gross Ton
446 - Convention (Subpart B), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Inspection history · 30
17 November 2022
Exemption
Administrative · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 7596185
1 August 2022
Plan Review (Other than "T")
Administrative · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 7521987
17 September 2021
Type not recorded
No type recorded · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7314699
8 August 2014
Annual Inspection
Physical examination · Activities Europe · Activity 4929902
18 July 2012
Annual Inspection · MTSA/ISPS Verification · MARPOL Annex I Examination · DAPI Audit
Physical examination · Activities Europe · Activity 4369424
25 July 2011
DAPI Audit · Annual Inspection · SIP Inspection/Audit · MTSA/ISPS Verification · MARPOL Annex I Examination
Physical examination · Activities Europe · Activity 4047436
3 July 2009
MARPOL Annex I Examination · SIP Inspection/Audit
Physical examination · Activities Europe · Activity 3525484
10 April 2008
MTSA/ISPS Verification · Annual Inspection · Hull Examination
Physical examination · Activities Europe · Activity 3162021
4 April 2008
SIP Initial Entry · Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3177603
22 January 2008
MTSA/ISPS Verification
Physical examination · Activities Europe · Activity 3134131
24 July 2007
Deficiency Check
Physical examination · Activities Europe · Activity 3005606
16 May 2007
Annual Inspection
Physical examination · Activities Europe · Activity 2938822
10 August 2006
Security Plan Amendment Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2742308
24 May 2006
Deficiency Check · Re-Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2667644
13 July 2005
Administrative Inspection
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 2425569
28 April 2005
Deficiency Check
Physical examination · MIDET HARVEY CANAL DETAIL · USCG Heartland District (CGD-H) · Activity 2344998
17 April 2005
Cargo Tank Internal · Hull Examination · Internal Structural Exam · MTSA/ISPS Verification · COI Inspection
Physical examination · MIDET HARVEY CANAL DETAIL · USCG Heartland District (CGD-H) · Activity 2323992
20 December 2004
Administrative Inspection
Administrative · Marine Safety Center (MSC) · Activity 2262647
29 April 2004
MTSA/ISPS Verification
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2086580
19 April 2004
Security Plan Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2047488
25 November 2003
Deficiency Check
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 1954402
14 August 2003
Re-Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 1875780
2 April 2003
Hull Examination
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 1766987
16 September 2002
Annual Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1676116
20 September 2001
Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1382384
22 May 2001
Damage Survey · Examination of Repairs
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1065636
18 May 2001
Damage Survey
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1064196
16 May 2001
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 160226
26 April 2001
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1063246
23 June 2000
Initial Certification · Hull Examination · Construction Oversight · Initial Construction-Excluding Oversight
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1420383
Documentation › Safety Management System › Critical Equipment/Systems ID Procedures
Issued 25 July 2011
Resolved
Revise and submit automation test procedes for approval to reflect but not inclusive of overspeeds, low lube oil shutdowns, ect as per 46CFR 62.50.
Action required: 705 - Other - as specified
Due 25 August 2011
Resolved 18 August 2011
Resolution: Orginally approved test procedures were located and sent to vessel.
Lifesaving › Launching Appliances › Davit
Issued 25 July 2011
Resolved
Provide certificates and USCG approval for rescue boat davit and conduct required loading testing according to 46 CFR 133.175.
Action required: 705 - Other - as specified
Due 25 August 2011
Resolved 22 August 2011
Resolution: Placard placed on davit and testing was completed in the presence of an attending ABS surveyor.
Fire Fighting › Fixed CO2 Fire Extinguishing System › Servicing
Issued 25 July 2011
Resolved
Conduct required testing of fixed firefighting and portable extinguishers at an approved DOT facility as per 46 CFR 132.350. Extended until 25 Nov as new equipment is being shipping via US.
Action required: 705 - Other - as specified
Due 25 November 2011
Resolved 8 March 2012
Resolution: Received certificates from an approved DOT facility.
Fire Fighting › Fixed CO2 Fire Extinguishing System › Location
Issued 25 July 2011
Resolved
Provide proposal for placing a discharge alarm for the CO2 system for release head in the ECR.
Action required: 705 - Other - as specified
Due 25 September 2011
Resolved 10 August 2011
Resolution: ABS witnessed that the system was audible within the ECR while the main engines and generators running.
Engineering › Fuel Oil Storage/Transfer System › Hose
Issued 3 July 2009
Resolved
Provide fuel hose certificate. Item reported cleared via E-mail dated 27Jul2009 and shall remain open until verified to be corrected by attending USCG Marine Inspector.
Due 17 July 2010
Resolved 6 May 2010
Lifesaving › Launching Appliances › Falls
Issued 3 July 2009
Resolved
Provide certificate for davit wire rope. Item reported cleared via E-mail dated 27Jul2009 and shall remain open until verified to be corrected by attending USCG Marine Inspector.
Due 17 July 2010
Resolved 6 May 2010
Lifesaving › Launching Appliances › Davit
Issued 3 July 2009
Resolved
Repair/replace rescue boat davit motor in accordance with manufacturer's manual. Item reported cleared via E-mail dated 27Jul2009 and shall remain open until verified to be corrected by attending USCG Marine Inspector.
Due 17 July 2010
Resolved 6 May 2010
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 3 July 2009
Resolved
Replace cracked light on STBD bridge ring buoy. Item reported cleared via E-mail dated 27Jul2009 and shall remain open until verified to be corrected by attending USCG Marine Inspector.
Due 17 July 2010
Resolved 6 May 2010
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 3 July 2009
Resolved
Replace/repair secondary stern light. Item reported cleared via E-mail dated 27Jul2009 and shall remain open until verified to be corrected by attending USCG Marine Inspector.
Due 17 July 2010
Resolved 6 May 2010
Navigation › Emergency Steering › Communications to Emergency Steering
Issued 3 July 2009
Resolved
Amend bridge emergency steering instructions to include instructions for bridge operator. Item reported cleared via E-mail dated 27Jul2009 and shall remain open until verified to be corrected by attending USCG Marine Inspector.
Due 17 July 2010
Resolved 6 May 2010
Lifesaving › Immersion Suits › General
Issued 16 May 2007
Resolved
Provide lights for all immersion suits onboard iaw 46 CFR 133.70(c)(4).
Condition: Improper/Lack of Maintenance
Due 16 August 2007
Resolved 24 July 2007
Fire Fighting › Portable CO2 Fire Extinguisher › Service
Issued 16 May 2007
Resolved
Prove that hydro testing of portable CO2 fire extinguishers were carried out by DOT approved facility iaw 46 CFR 132.350(c)(1) and NFPA 10 or renew or re-qualify the bottle by having it service by DOT approved facility.
Condition: Improper/Lack of Maintenance
Due 16 August 2007
Resolved 16 May 2007
Lifesaving › Launching Appliances › Davit
Issued 16 May 2007
Resolved
Replace broken slewing valve handle for the rescue boat davit or renew the whole valve unit.
Condition: Damaged By Earlier Event
Due 16 August 2007
Resolved 16 May 2007
Resolution: Corrected prior to the conclusion of the inspection.
Construction/Loadline › Hull › Hull Plating
Issued 24 May 2006
Resolved
MAKE PERMANENT REPAIRS TO PORT AFT SIDESHELL, BOTTOM PLATE AND STERN HULL PLATING AS MARKED AND DISCUSSED BY THIS INSPECTOR PRIOR TO SAILING. THIS VSL IS TO PROCEED IMMEDIATELY TO CONDUCT PERMANENT REPAIRS. CONTACT THIS INSPECTOR TO NOTIFY WHERE VSL IS GOING FOR REPAIRS AND TO APPROVE FINAL REPAIRS.
Action required: 705 - Other - as specified
Due 24 June 2006
Resolved 27 May 2006
Resolution: COMPLETED ALL REPAIRS TO SIDESHELL AND BOTTOM AS MARKED.
Fire Fighting › Structural Fire Protection - General › Accommodation Space Protection
Issued 17 April 2005
Resolved
Repair or replace the fire alarm pull box located in house on the main deck in way of the head.
Action required: 705 - Other - as specified
Due 1 May 2005
Resolved 28 April 2005
Lifesaving › Rescue Boat › Carriage Requirement
Issued 17 April 2005
Resolved
Conduct full load weight test to the rescue boat and davit assembly.
Action required: 705 - Other - as specified
Due 1 May 2005
Resolved 28 April 2005
Lifesaving › Lifebuoys
Issued 14 August 2003
Resolved
Provide proper arrangement for smoke/ring buoys on both port and starboard bridge wings. LEGACY COMPONENT DESC: Self-Activitating Smoke Signals
Action required: 705 - Other - as specified
Due 14 September 2003
Resolved 25 November 2003
Resolution: Installed brackets.
Lifesaving › Rescue Boat
Issued 14 August 2003
Resolved
Renew or end for end davit cable for rescue boat. LEGACY COMPONENT DESC: Davit cable
Action required: 705 - Other - as specified
Due 14 September 2003
Resolved 1 September 2003
Resolution: Renewed rescue boat davit cable.
Communications › Alarms/Indicators
Issued 14 August 2003
Resolved
Provide power failure alarms for steering pumps. LEGACY COMPONENT DESC: Steering Failure Alarm System
Action required: 17 - Rectify deficiencies prior to departure
Due 14 September 2003
Resolved 1 September 2003
Fire Fighting › Portable Foam Applicators
Issued 14 August 2003
Resolved
Provide proper foam eductor for the carriage of marine portable tanks. LEGACY COMPONENT DESC: Foam Equipment
Action required: 701 - Prior to carriage of passengers/cargo
Due 14 September 2003
Resolved 1 September 2003
Documentation › Certificates/Documents
Issued 16 September 2002
Resolved
Vesel did not receive annual endorsement to Safety Equipment Certificate. This was attributable to the fact that MSO NOLA is currently not sending inspector overseas for annual inspections. Requested owners rep to attempt to get ABS to complete annual survey and endorsement on CG's behalf. LEGACY COMPONENT DESC: Cargo Ship Safety Equipment Certificate
Due 30 October 2002
Resolved 17 September 2003
Documentation › Certificates/Documents
Issued 16 September 2002
Resolved
Vessel did not receive annual endorsement for IOPP certificate. This was attributable to the fact that MSO New Orleans is currently not sending inspectors overseas for annual inspections. Requested owners rep attempt to get ABS to conduct annual survey and endorsment on CG's behalf.
Due 30 October 2002
Resolved 17 September 2003