MAURY USCG vessel records
← All vessels

CHUCKY'S PRIDE

Built
1978
Last inspected
9 April 2025
Documentation
Valid · NVDC file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 9 April 2025
…with no type recorded1
Operational controls None recorded without a removal date
Years with a record 10 calendar years (2016–2025)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

WDG2133
Flag
UNITED STATES
Maury page id
psix-49775

Documentation record

Registered dimensions (L × B × D)47.5 ft × 15.7 ft × 6.7 ft
Registered tonnagegross 37 / net 26
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderDELTA MARINE INDUSTRIES INC · SEATTLE, WA, UNITED STATES · built 1978
Hull materialFRP (Fiberglass)
PropulsionDiesel Reduction
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing portSAN FRANCISCO, CA
Endorsements, as the file codes themcw_un, fi, reg
DocumentationValid · issued 5 May 2026 · expires 30 April 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it37 - Regulatory (Subpart C or D), Gross Ton
26 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Professional
The full record for this vessel

Behind this panel: 23 inspections, each with its date, unit and type; 17 deficiencies with the resolution recorded against each; operational controls, none recorded without a removal date; 3 other vessels inspected with it; no other recorded names; the documentation record: dimensions, tonnage, builder, hailing port and endorsements. Every line is a record the Coast Guard wrote; the counts above are the same counts as in the summary, and they are free.

Professional is $39 a month or $299 a year, or $19.99 a month locked for life at the founding rate, for the first 200 subscribers. It unlocks every detail section on every vessel page, fleet watch tied to your account, and ownership records on request. Already a subscriber? Sign in.

Maury does not score, rate or grade vessels, at any price.

Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 1972 to 2026, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspected as a tow unit · 3

The Coast Guard recorded this vessel and the following in the same inspection activity — normally a tug and the barges in its tow. A recreational or unclassed hull in the same activity is held and not published, so it does not appear here: these lists are a floor, not a complete manifest.

AMIGO Passenger (Inspected) · MISLE 47687 · 4 November 2023 · activity 7833539CMA CGM CHILE Freight Ship · MISLE 1638425 · 4 November 2023 · activity 7833539SF WATER TAXI IV Passenger (Uninspected) · MISLE 1813196 · 4 November 2023 · activity 7833539

Inspection history · 23

9 April 2025 COI Inspection · Deficiency Check
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 8099617
21 January 2025 Drydock Exam · Internal Structural Exam · Hull Examination
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 8063011
21 March 2024 Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7881166
4 November 2023 Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7833539
17 April 2023 In-Service Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7671241
9 February 2023 Annual Inspection · Deficiency Check · Administrative Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7633935
7 February 2023 Internal Structural Exam · Drydock Exam · Hull Examination · Deficiency Check
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7631643
9 December 2022 Plan Review "T" Boat
Administrative · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7606774
18 January 2022 Annual Inspection · Deficiency Check
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7381710
11 January 2021 Internal Structural Exam · Hull Examination · Drydock Exam
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7120111
11 January 2021 Deficiency Check · Internal Structural Exam · COI Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7120672
12 May 2020 Annual Inspection · Deficiency Check
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6951931
18 February 2020 Administrative Inspection · Drydock Exam
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6910584
2 January 2020 Administrative Inspection · Simplified Stability Test
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6936765
20 May 2019 Administrative Inspection · Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6686681
8 January 2019 Drydock Exam · Plan Review "T" Boat · Examination of Repairs · Administrative Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6607405
26 February 2018 Administrative Inspection · Deficiency Check · DAPI Audit · Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6358224
22 January 2018 Internal Structural Exam · Administrative Inspection · Drydock Exam
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6339163
29 March 2017 In-Service Inspection · Administrative Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6114037
21 February 2017 Administrative Inspection · Annual Inspection · Deficiency Check
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6091800
14 November 2016 Administrative Inspection · Excursion Permit
Administrative · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6041090
26 January 2016 Drydock Exam · Deficiency Check · Internal Structural Exam
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 5803227
26 January 2016 COI Inspection · Administrative Inspection · DAPI Audit
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 5804014

Deficiency record · 17

07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 9 April 2025 Resolved
Vessels described by 46 CFR 175.110(c) must have an interconnected fire detection system in compliance with § 181.450 installed in all enclosed areas where passengers and crew have routine access, including accommodation spaces and machinery spaces. Marine Inspector identified that the smoke detectors on board were not interconnected. Replace with UL 217 compliant detectors capable of being interconnected in each space and conduct satisfactory smoke detector prior to operating in outside of lakes, bays, and sounds. 46 CFR 181.405(c)
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 23 April 2025
Resolved 14 April 2025
Resolution: Observed satisfactory interconnected smoke detector test.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 9 April 2025 Resolved
The flame screens must consist of a single screen of corrosion resistant wire of at least 30 × 30 mesh. The flame screens...must be of such size and design as to prevent reduction in the net cross sectional area of the vent pipe and permit cleaning or renewal of the flame screens or arrester elements. Marine Inspector identified that fuel tank vents were painted over inhibiting the cross sectional area of the mesh. 46 CFR 182.450(e)
Condition: Damaged By Earlier Event
Action required: 16 - Rectify deficiencies w/in 14 days
Due 23 April 2025
Resolved 9 April 2025
Resolution: Received photographs from operator showing that the paint covering the flame screens was cleaned.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 9 April 2025 Resolved
In systems and applications where flexible hoses are permitted to be clamped: (1) Double hose clamping is required where practicable. Marine Inspector identified missing double hose clamp on bilge pump in the midship void. 46 CFR 182.410(d)(1)
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 23 April 2025
Resolved 9 April 2025
Resolution: Received photograph from operator showing that double clamping was added to bilge pump.
04 - Emergency Systems › N/A - No Subsystem › Fire drills
Issued 9 April 2025 Resolved
Fire fighting drills and training shall be logged or otherwise documented for review by the Coast Guard upon request. The drill entry shall include the following information:(1) Date of the drill and training; and(2) General description of the drill scenario and training topics. Marine Inspector identified that the fire drill entries in the vessel logbook were not formatted correctly. 46 CFR 185.524 (d)
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 14 April 2025
Resolved 14 April 2025
Resolution: Observed new drill log forms to ensure proper documentation of drills and trainings onboard the vessel.
05 - Radio Communications › N/A - No Subsystem › Other (radio communication)
Issued 9 February 2023 Resolved
A vessel must comply with the applicable requirements for any radio and Electronic Position Indicating Radiobeacon (EPIRB) installations, including the requirements for a station license and installation certificates to be issued by the Federal Communications Commission, as set forth in 47 CFR part 80. Vessel's Safety Radiotelephony Certificate was expired. Renew Safety Radiotelephony Certificate.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 11 March 2023
Resolved 14 February 2023
Resolution: Obtained Communications Act Safety Radiotelephony Certificate
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 9 February 2023 Resolved
Fire fighting drills and training shall be logged or otherwise documented for review by the Coast Guard upon request. The drill entry shall include the following information: Date of the drill and training; and General description of the drill scenario and training topics. No current records of drills. Completed satisfactory fire drill and logged completion.
Condition: Invalid
Action required: 10 - Deficiency Rectified
Due 9 February 2023
Resolved 9 February 2023
Resolution: Conducted fire drill and correctly logged drill.
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 9 February 2023 Resolved
Abandon ship and man overboard drills and training shall be logged or otherwise documented for review by the Coast Guard upon request. The drill entry shall include the following information: Date of the drill and training; and General description of the drill scenario and training topics. No current record of drills. Completed satisfactory drill and logged completion.
Condition: Invalid
Action required: 10 - Deficiency Rectified
Due 9 February 2023
Resolved 9 February 2023
Resolution: Completed satisfactory drill and logged completion.
02 - Structural Conditions › N/A - No Subsystem › Closing devices/watertight doors
Issued 18 January 2022 Resolved
Each hatch cover must have securing devices. Engine room hatch on deck does not have a securing device.
Condition: Design Flaw
Action required: 50 - Rectify deficiencies w/in 30 days
Due 17 February 2022
Resolved 9 February 2022
Resolution: Owner installed a latch/securing device on hatch. All SAT
11 - Life Saving Appliances › N/A - No Subsystem › Stowage and provision of liferafts
Issued 11 January 2021 Resolved
Each survival craft must be stowed so that when the vessel sinks the survival craft floats free and automatically inflates. Painter of IBA is attached to vessel, not the weak link.
Condition: Improper Installation
Action required: 10 - Deficiency Rectified
Due 14 January 2021
Resolved 14 January 2021
Resolution: Attached painter to weak link.
08 - Alarms › N/A - No Subsystem › Emergency signal
Issued 11 January 2021 Resolved
Visual and audible bilge alarm must be provided at the operation station. Audible alarm has ability of being silenced.
Condition: Improper Installation
Action required: 10 - Deficiency Rectified
Due 14 January 2021
Resolved 14 January 2021
Resolution: Operator disconnected alarm wiring from operation panel. Alarm silencer is no longer able to be used.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 11 January 2021 Resolved
Lifejackets on oceans route must have water lights. No operable lights on 03 adult and 01 child PFD's.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 28 January 2021
Resolved 20 January 2021
Resolution: Received pictures of newly purchased and installed waterlights on PFD's. See documents tab under deficiencies for more.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 12 May 2020 Resolved
Each child sized life jacketmust be stored in a location the is appropriately marked and separated from adult life jackets. The vessel's life jacket placards are outdated and do not accurately reflect that number and location of lifejackets. Update the placards to accurately reflect the current number storage location of the lifejackets.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 12 June 2020
Resolved 5 June 2020
Resolution: Received pictures documenting the corrected deficiencies for required PFD placards.
05 - Radio Communications › N/A - No Subsystem › Other (radio communication)
Issued 12 May 2020 Resolved
A vessel must comply witht the applicable requirements for any radio and EPIRB installation, including certificates issued by the FCC as set forth in 47 CFR part 80. The vessel's FCC radio safety telephony certificate was not properly endorsed by the issuing agency. Provide evidence to the Coast Guard that the current certificate is valid and properly endorsed.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 12 June 2020
Resolved 19 June 2020
Resolution: Received photo documentation from the operator.
11 - Life Saving Appliances › N/A - No Subsystem › Buoyant apparatus
Issued 12 May 2020 Resolved
An inflatable buoyant apparatus must be serviced at an approved facility in accordance with the requirements of 46 CFR 160.151 no later than the month and year on its servicing sticker. The required annual maintenance for the IBA was not completed prior to the expiration month. Complete the required servicing and provide evidence to the Coast Guard.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 5 June 2020
Resolution: Received photo documentation of installed 30-person IBA, due for next servicing by May 2022.
Engineering › Bilge Water Management System › Not Operational
Issued 26 February 2018 Resolved
Vessel experienced a clog in their fixed bilge system resulting in a unsatisfactory bilge pump test.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 2 March 2018
Resolved 2 March 2018
Resolution: Vessel installed UL 1113 approved electric bilge pumps to satisfy bilge requirements.
Engineering › Bilge Water Management System › Interface Detector
Issued 26 February 2018 Resolved
Audible bilge high level alarm is not operational.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 2 March 2018
Resolved 2 March 2018
Resolution: Verified operation of visual and audible alarms in all required spaces.
Communications › Alarms/Indicators › High Water Alarm
Issued 21 February 2017 Resolved
Repair audible alarm on bilge high level alarm. 46CFR182.530
Action required: 705 - Other - as specified
Due 7 March 2017
Resolved 21 February 2017
Resolution: Recieved video from operator demonstrating satisfactory operation of audible high water alarms.

Ownership record