MAURY USCG vessel records Sign in
← All vessels

SEAWOLF

SEAWOLF is a 1978 industrial vessel. The Coast Guard has recorded 50 inspections since 1982, most recently in November 2023, along with 74 deficiencies and 2 casualty investigations between 2007 and 2018.

Records from 1982 to 2023. Most recent: inspection, 7 November 2023.

Built
1978
Last inspected
7 November 2023
Documentation
No Operation - PM · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

7802524 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
WDD9036
Flag
UNITED STATES
338042000, 367150770, 367306130 (licence lapsed)
Maury page id
psix-49864

Inspections, by type

…with no type recorded10
Years with a record 27 calendar years (1982–2023)
The 50 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 3 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Miscellaneous Vessel class in Maury's sources begin in 1979.

Documentation record

Registered dimensions (L × B × D)165.0 ft × 40.0 ft × 12.7 ft
Registered tonnagegross 270 / net 183
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderBOURG DRY DOCK & SERVICE · BOURG, LA, UNITED STATES · built 1978
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portNEW ORLEANS, LA
Trade endorsementsCoastwise, unrestricted
DocumentationNo Operation - PM · issued 30 June 2004
Service, as the file records itIndustrial Vessel
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it270 - Regulatory (Subpart C or D), Gross Ton
183 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

WDD9036MMSI 367306130 · expired · compulsorily equipped · granted 2 August 2007, cancelled 7 October 2017
WDD4896MMSI 367150770 · expired · compulsorily equipped · granted 15 November 2006, cancelled 21 January 2017 · licensed under a name not among this hull’s recorded names (not shown)
WAQ9183MMSI 338042000 · expired · compulsorily equipped · granted 21 December 2005, cancelled 2 April 2016 · licensed under a name not among this hull’s recorded names (not shown)
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspected as a tow unit · 4

The Coast Guard recorded this vessel and the following in the same inspection activity — normally a tug and the barges in its tow. A recreational or unclassed hull in the same activity is held and not published, so it does not appear here: these lists are a floor, not a complete manifest.

SEA OX Towing Vessel · MISLE 127248 · 14 August 2018 · activity 6512017COASTAL 20 Freight Barge · MISLE 671019 · 14 August 2018 · activity 6512017GEORGE D. WILLIAMS Industrial Vessel · MISLE 266230 · 31 May 1998 · activity 58026MAN O WAR Offshore Supply Vessel · MISLE 445499 · 31 May 1998 · activity 58026

Inspection history · 50

7 November 2023 Administrative Inspection
Administrative · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 7821696
14 August 2018 Type not recorded
No type recorded · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 6512017
17 March 2014 Type not recorded
No type recorded · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 4817919
6 March 2014 Administrative Inspection · Annual Inspection · MTSA Verification · Deficiency Check
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 4817904
29 June 2012 DAPI Audit
Administrative · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 4360728
2 September 2011 DAPI Audit
Administrative · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 4137242
22 November 2010 MTSA Verification · COI Inspection
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 3896710
19 January 2010 DAPI Audit
Administrative · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3669364
16 December 2008 Deficiency Check
Physical examination · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 3380498
19 November 2008 MTSA Verification · Annual Inspection
Physical examination · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 3366207
10 April 2008 Hull Examination · Internal Structural Exam
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3181391
29 September 2007 Type not recorded
No type recorded · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 3105801
25 September 2007 Deficiency Check · Re-Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3065599
10 April 2007 Examination of Repairs · Deficiency Check · Administrative Inspection · In-Service Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2906114
12 October 2006 Security Plan Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2799083
20 September 2006 Administrative Inspection
Administrative · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 2782834
19 September 2006 Administrative Inspection
Administrative · Marine Safety Center (MSC) · Activity 2782175
25 August 2006 Re-Inspection · MTSA Verification
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 2759593
15 February 2006 Hull Examination · Re-Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 2585196
6 June 2005 MTSA Verification · COI Inspection
Physical examination · MSU LAKE CHARLES · USCG Heartland District (CGD-H) · Activity 2381178
3 May 2005 Administrative Inspection
Administrative · MSU LAKE CHARLES · USCG Heartland District (CGD-H) · Activity 2348123
30 June 2004 Administrative Inspection
Administrative · MSU LAKE CHARLES · USCG Heartland District (CGD-H) · Activity 2116019
22 December 2003 Security Plan Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 1972331
8 December 2003 Internal Structural Exam · Re-Inspection · Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1960709
14 February 2003 Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1743189
21 February 2002 Annual Inspection · Deficiency Check · Administrative Inspection
Physical examination · MSU LAKE CHARLES · USCG Heartland District (CGD-H) · Activity 1488041
2 February 2001 Hull Examination · COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1454897
25 February 2000 Re-Inspection · Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1369532
8 February 1999 Hull Examination · COI Inspection
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1375632
31 May 1998 Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 58026
1 December 1997 COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1381072
24 November 1997 Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 773755
27 November 1996 Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1416404
23 November 1995 Hull Examination · COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1383095
19 January 1995 Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1177228
22 October 1994 COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 860715
22 October 1994 Inclining Experiment · Deficiency Check · COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1354976
27 January 1994 Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1451919
29 December 1993 Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1382684
26 June 1993 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 141097
16 October 1992 COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1433964
14 January 1992 Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1266684
14 May 1991 Persons In Addition to Crew
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 904030
18 December 1990 Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 914257
2 November 1990 MARPOL Annex II Examination · Hull Examination · COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1215455
2 October 1990 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1233180
25 September 1984 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 975311
29 June 1984 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1286757
29 June 1984 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1308259
7 October 1982 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 964131

Deficiency record · 74

Navigation › Piloting/Steering › Marine Charts
Issued 6 March 2014 Resolved
Charts for areas operating not available.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 17 April 2014
Resolution: Updated charts onboard.
Electrical › Lighting (emergency) › Lighting Fixture
Issued 6 March 2014 Resolved
E-lighting in both dive shacks not operable.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 17 April 2014
Resolution: E-lights repaired and tested.
Lifesaving › Lifebuoys › Serviceable
Issued 6 March 2014 Resolved
Lifebuoy on 01 level not servicable.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 17 April 2014
Resolution: Lifebuoy replaced.
Engineering › Fuel Oil Service System › Filter
Issued 6 March 2014 Resolved
F/O filter on STBD side engine room is missing flame shield.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 17 April 2014
Resolution: Flame sheild replaced.
Electrical › Electrical Distribution System (service) › Distribution Panel Bus
Issued 6 March 2014 Resolved
Blanks missing in breaker panel in engine room.
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Resolved 17 April 2014
Resolution: Blanks installed.
Construction/Loadline › Structures › Door
Issued 6 March 2014 Resolved
Dogging wrench missing on port engine room individual dogged door.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 17 April 2014
Resolution: Dogging wrench replaced.
Electrical › Electrical Distribution System (service) › Junction Box
Issued 6 March 2014 Resolved
Junction box on mast in bad condition.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 17 April 2014
Resolution: Junction boxes replaced.
Engineering › Compressed Air System (control) › Receiver/Bottle
Issued 6 March 2014 Resolved
Both pressure vessels on back deck for diver's air are wasted and are required to be removed from the vessel. Both condemned
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 17 April 2014
Resolution: Tanks replaced.
Deck/Cargo › Cargo Transfer (solid) › General
Issued 6 March 2014 Resolved
Crane test not conducted as required by 46 CFR 107.259.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 17 April 2014
Resolution: Crane test completed.
Documentation › Certificates/Documents › Stability Letter
Issued 24 November 2010 Resolved
Procure updated ICLL certificate reflecting statement as required by USCG MSC letter H1-0702615 dated August 23, 2007.
Action required: 705 - Other - as specified
Due 24 December 2010
Resolved 7 January 2011
Resolution: Duty Marine Inspector verified that vessel had obtained updated ICLL cert.
Lifesaving › Inflatable Liferafts › Capacity
Issued 24 November 2010 Resolved
Install additional inflatable liferafts port and starboard to accomodate max persons allowed IAW 46CFR199.130(3).
Action required: 17 - Rectify deficiencies prior to departure
Resolved 25 November 2010
Resolution: Duty Marine Inspector verified that vessel installed two additional 20-person inflatable liferafts, one per side, just forward of existing liferafts, giving a 40 person per side liferaft capability.
Documentation › Safety/Response Plans/Programs › Fire Control Plans
Issued 24 November 2010 Resolved
Update additional liferafts on plan and permanently exhibit Fire Control Plans.
Action required: 705 - Other - as specified
Due 24 December 2010
Resolved 25 November 2010
Resolution: Duty Marine Inspector verified that fire control plan was updated to show additional life rafts.
Documentation › Certificates/Documents › Stability Letter
Issued 24 November 2010 Resolved
Post copy of stability letter dated August 23, 2007.
Action required: 705 - Other - as specified
Due 24 December 2010
Resolved 25 November 2010
Resolution: Duty Marine Inspector verified that stability letter had been posted as required.
Electrical › Electric Supply System (service) › Cable
Issued 24 November 2010 Resolved
Conduct conversion plan verification of plans listed in USCG MSC letter Ser# E2-0801867 and E2-0802511 (conversion from OSV to DSV).
Action required: 705 - Other - as specified
Due 1 April 2011
Resolved 17 May 2011
Resolution: Verified installation for equipment discussed in letters above.
Fire Fighting › Fixed Fire Detection System › Heat Detectors
Issued 19 November 2008 Resolved
Heat detectors in engine room not operating properly. Replace inoperable detectors.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 21 November 2008
Electrical › Electrical Distribution System (service) › Wiring
Issued 19 November 2008 Resolved
Found several unused dead ended wires in engine room and on rescue boat davit. All such wires to be removed.
Action required: 705 - Other - as specified
Due 19 December 2008
Resolved 16 December 2008
Lifesaving › Launching Appliances › Davit
Issued 19 November 2008 Resolved
Replace wasted hydraulic couplings.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 21 November 2008
Navigation › Piloting/Steering › Marine Charts
Issued 19 November 2008 Resolved
Provide on board updated navigation chart of suitable scale to navigate the Calcasieu River.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 21 November 2008
Accommodation/Occupational Safety › Occupational Safety › Rubbish/Waste Materials
Issued 19 November 2008 Resolved
Remove excess oily water from bilge and provide receipt/documentation.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 21 November 2008
Engineering › Diesel Engine (propulsion-reduction gear) › Valve
Issued 19 November 2008 Resolved
Replace leaking valve cover gaskets on MDEs
Action required: 17 - Rectify deficiencies prior to departure
Resolved 21 November 2008
Engineering › Shafting/Propeller Arrangements › Coupling Bolt
Issued 19 November 2008 Resolved
Properly double nut all shaft packing bolts.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 21 November 2008
Personnel › Certificates/Documents/Licenses › License, Operator
Issued 25 September 2007 Resolved
Provide FCC Radio Operator's Permit for Licensed Mate.
Due 25 October 2007
Resolved 27 September 2007
Resolution: Captain verified Lic. Mate was in process of completing FCC tests to obtain permit.
Navigation › Piloting/Steering › US Coast Pilot
Issued 25 September 2007 Resolved
Provide current US Coast Pilot for area of operation, along with local notice to mariners.
Due 25 October 2007
Resolved 27 September 2007
Resolution: Provided new US Coast Pilot and local notice to mariners.
Operations/Management › Drug and Alcohol Testing › Testing, Equipment
Issued 25 September 2007 Resolved
Provide Alcohol Test Strips.
Due 25 October 2007
Resolved 27 September 2007
Resolution: Purchased Alcohol Test Strips.
Operations/Management › Lifesaving › Op Readiness/Maintenance/Inspection
Issued 25 September 2007 Resolved
Provide Lifesaving Maintenance Record.
Due 25 October 2007
Resolved 27 September 2007
Resolution: Provided Lifesaving Maintenance Record.
Navigation › Piloting/Steering › Compass Deviation Table
Issued 25 September 2007 Resolved
Provide Compass Deviation Table
Due 25 October 2007
Resolved 27 September 2007
Resolution: Captain verified Compass Deviation Table would be completed on 9/28 in Fourchon, LA.
Electrical › Electric Generation Source (service) › Generator
Issued 25 September 2007 Resolved
Demonstrate proper operation of generator overspeeds.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 27 September 2007
Resolution: Generators Repaired and Renewed by Marine Electric.
Communications › Alarms/Indicators › Engineers' Assistance-needed Alarm
Issued 25 September 2007 Resolved
Provide automation test results.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 27 September 2007
Resolution: Automation Test results provided by Marine Electric.
Documentation › Manuals/Policy Documentation › Steering Gear Changeover Instructions
Issued 25 September 2007 Resolved
Provide.
Due 25 October 2007
Resolved 27 September 2007
Resolution: Created Steering Gear Changeover Instructions.
Electrical › Electrical Distribution System (service) › Circuit Breaker
Issued 25 September 2007 Resolved
Renew cover to Circuit Breaker Panel by Bow Thruster Engine.
Due 25 October 2007
Resolved 27 September 2007
Resolution: Renewed cover to Circuit Breaker Panel.
Stability › Incline Test › General
Issued 10 April 2007 Resolved
Noted machinery and dive equipment elevated on the aft deck. Required vsl operator to provide proof of suitability of stability ltr and loading diagram in current outfitting. ABS will provide new stability information.
Action required: 705 - Other - as specified
Resolved 27 September 2007
Resolution: ABS and vessel provided new stability information. New stability letter located in vessel documentation.
Engineering › Fuel Oil Service System › Hose
Issued 6 June 2005 Resolved
Port MDE: Replace F/O hoses on engine mounted F/O pump
Action required: 705 - Other - as specified
Resolved 2 September 2005
Engineering › Fuel Oil Service System › Hose
Issued 6 June 2005 Resolved
Port MDE: Replace F/O hoses from RACOR filters to F/O pump
Action required: 705 - Other - as specified
Resolved 2 September 2005
Engineering › Diesel Engine (auxiliary) › Overspeed Device
Issued 6 June 2005 Resolved
Starboard SSDG: Repair and test generator
Action required: 705 - Other - as specified
Resolved 2 September 2005
Electrical › Electric Generation Source (service) › Generator Cable
Issued 6 June 2005 Resolved
Port & Starboard SSDG: Properly support wires hanging down in engine oil drip pans.
Action required: 705 - Other - as specified
Resolved 2 September 2005
Electrical › Electrical Distribution System (service) › Wiring
Issued 6 June 2005 Resolved
Ladderway to Engine room: Properly secure wire in overhead cable way with metal banding
Action required: 705 - Other - as specified
Resolved 2 September 2005
Operations/Management › Vessel Safety Management › Maintenance of Ship/Equipment
Issued 6 June 2005 Resolved
Engine Room Bilges: Pump down and clean all F/O L/O and accumulated trash from engine room bilges
Action required: 705 - Other - as specified
Resolved 2 September 2005
Electrical › Lighting (service) › Lighting Fixture
Issued 6 June 2005 Resolved
Aft engine room ovhd: Replace broken light cover
Action required: 705 - Other - as specified
Resolved 2 September 2005
Operations/Management › Vessel Safety Management › Maintenance of Ship/Equipment
Issued 6 June 2005 Resolved
Engine Room General: Clean all oil residue from under SSDGs and under air compressor located portside aft in engine room
Action required: 705 - Other - as specified
Resolved 2 September 2005
Operations/Management › Vessel Safety Management › Maintenance of Ship/Equipment
Issued 6 June 2005 Resolved
Steering compartment: Properly repair or replace all leaking hydraulic fittings, hoses, & seals on steering gear
Action required: 705 - Other - as specified
Resolved 2 September 2005
Operations/Management › Vessel Safety Management › Maintenance of Ship/Equipment
Issued 6 June 2005 Resolved
Steering compartment: Pump down and clean all oil from bilge pockets
Action required: 705 - Other - as specified
Resolved 2 September 2005
Construction/Loadline › Structures › Transverse Bulkhead
Issued 6 June 2005 Resolved
Steering Compartment: Crop and renew all wasted steel in way of aft bulkhead, guage as neccessary.
Action required: 705 - Other - as specified
Resolved 2 September 2005
Construction/Loadline › Hull › Stiffener
Issued 6 June 2005 Resolved
Steering Compartment: Crop and renew wasted steel in way of Port and Starboard rudder support structure
Action required: 705 - Other - as specified
Resolved 2 September 2005
Construction/Loadline › Hull › Stiffener
Issued 6 June 2005 Resolved
Steering compartment: Crop and renew wasted steel in way of center section bracing
Action required: 705 - Other - as specified
Resolved 2 September 2005
Operations/Management › Vessel Safety Management › Maintenance of Ship/Equipment
Issued 6 June 2005 Resolved
Deck crane: Replace broken glass in door of crane
Action required: 705 - Other - as specified
Resolved 2 September 2005
Documentation › Certificates/Documents › Certificate of Inspection
Issued 3 May 2005 Resolved
COI has expired outside it's 90 day window, vsl is required to schedule an inspection prior to any operations. Vsl is still required to have it's MTSA verification exam completed.
Due 24 April 2006
Resolved 24 April 2006
Accommodation/Occupational Safety › Ventilation
Issued 14 February 2003 Resolved
Engine room blowers need guards.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 19 February 2003
Resolution: Guards installed.
Electrical › Lighting (service)
Issued 14 February 2003 Resolved
Repair light fixture on 02 deck that is potential electrical hazard.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 19 February 2003
Resolution: Fixture corrected.
Engineering › Diesel Engine (propulsion-electric)
Issued 14 February 2003 Resolved
Filters needed repair.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 19 February 2003
Resolution: Filters repaired.
Electrical › Electrical Distribution System (service) › Non-conducting Deck Covering
Issued 21 February 2002 Resolved
Install rubber matting behind switchboard.
Due 21 March 2002
Resolved 4 March 2002
Resolution: Rubber matting installed behind switchboard.
Engineering › Diesel Engine (propulsion-reduction gear)
Issued 21 February 2002 Resolved
Conduct engine automation tests and ensure automation manual is onboard prior to sail date.
Due 21 March 2002
Resolved 4 March 2002
Resolution: Conducted satisfactory test of engine automation. Automation instructions onboard.
Deck/Cargo › Cargo Transfer/Lightering (liquid)
Issued 21 February 2002 Resolved
Conduct required hydrostatic test of fuel transfer hoses. LEGACY COMPONENT DESC: Transfer Hose
Due 21 March 2002
Resolved 4 March 2002
Resolution: Tested hoses.
Engineering › Steering Gear System › Rudder Bearing
Issued 21 February 2002 Resolved
Double nut packing gland.
Due 21 March 2002
Resolved 4 March 2002
Resolution: Rudder gland double nutted.
Fire Fighting › Fire Main › Condition
Issued 21 February 2002 Resolved
Fire main piping corroded to the point of failure at engine room fire station.
Condition: Improper/Lack of Maintenance
Due 21 March 2002
Resolved 4 March 2002
Resolution: Crew replaced corroded section of pipe.
Engineering › Diesel Engine (propulsion-reduction gear) › Piping (exhaust)
Issued 21 February 2002 Resolved
Replace lagging insulation.
Due 21 March 2002
Resolved 4 March 2002
Resolution: Crew replaced lagging.
Electrical › Lighting (emergency)
Issued 21 February 2002 Resolved
Install emergency lighting at engine room escape trunks and life raft embarkation stations.
Due 21 March 2002
Resolved 4 March 2002
Resolution: Lights installed.
Deck/Cargo › Cargo Transfer (solid)
Issued 21 February 2002 Resolved
Replace broken windshield in crane.
Due 21 March 2002
Resolved 4 March 2002
Resolution: Windshield replaced.
Accommodation/Occupational Safety › Medical/First Aid › Hospital Space
Issued 21 February 2002 Resolved
Request exemption for hospital space.
Due 21 March 2002
Resolved 4 March 2002
Resolution: Exemption recieved by MSU Lake Charles.
Engineering › Fuel Oil Storage/Transfer System › Tank
Issued 21 February 2002 Resolved
Fix leaks in fuel tank pipe niples.
Condition: Improper/Lack of Maintenance
Due 21 March 2002
Resolved 4 March 2002
Resolution: Tightened packing.
Documentation
Issued 2 February 2001 Resolved
Provide proof of Coast Guard plan review that vessel was built to 46 CFR subchapter "I".
Condition: Unknown
Due 2 February 2001
Resolved 2 February 2001
Lifesaving
Issued 25 February 2000 Resolved
Install a rescue boat in compliance with 8th Coast Guard District Rescue Boat Requirement dtd Nov. 12, 1998.
Condition: Unknown
Due 25 February 2000
Resolved 25 February 2000
Lifesaving
Issued 8 February 1999 Resolved
Install a rescue boat approved under the 46 CFR approval series 160.156 with appropriate launching apparatus or install a suitable workboat in compliance with 8th CG District Rescue Boat Requirements on Offshore_x001C_ Supply Vessels dtd Nov 12, 1998.
Condition: Unknown
Due 8 February 1999
Resolved 8 February 1999
Electrical
Issued 22 October 1994 Resolved
REPAIR EMERGENCY LIGHTING TO STEERING ROOM PASSAGEWAY.
Condition: Unknown
Due 22 November 1994
Resolved 25 October 1994
Accommodation/Occupational Safety
Issued 22 October 1994 Resolved
PROPERLY SECURE AFT TONNAGE OPENING TO HOUSE.
Condition: Unknown
Due 22 November 1994
Resolved 25 October 1994
Navigation
Issued 22 October 1994 Resolved
SWING COMPASS.
Condition: Unknown
Due 17 November 1994
Resolved 17 November 1994
Construction/Loadline
Issued 22 October 1994 Resolved
REPAIR PORT STACK HATCH WATER TIGHT DOOR.
Condition: Unknown
Due 22 November 1994
Resolved 25 October 1994
Engineering
Issued 22 October 1994 Resolved
INSTALL RACOR FUEL OIL FLAME IMPENGEMENT BOWLS.
Condition: Unknown
Due 22 November 1994
Resolved 25 October 1994
Lifesaving
Issued 22 October 1994 Resolved
SECURE LOOSE GEAR AND CONDUCT GENERAL HOUSEKEEPING PRIOR TO GETTING UNDERWAY.
Condition: Unknown
Due 22 November 1994
Resolved 25 October 1994
Documentation
Issued 2 November 1990 Resolved
PROVIDE PROOF OF APPROVED CG-1258 IN ACCORDANCE WITH 46 CFR 67.25-3.
Condition: Unknown
Due 2 November 1990
Resolved 2 November 1990
Documentation
Issued 29 June 1984 Resolved
SUBMIT CERTIFICATE OF DOCUMENTATION FOR ANNUAL ENDORSEMENT.
Condition: Unknown
Due 29 June 1984
Resolved 29 June 1984
Navigation
Issued 29 June 1984 Resolved
REPAIR PORT RADAR 46 CFR 96.
Condition: Unknown
Due 29 June 1984
Resolved 29 June 1984
Lifesaving
Issued 29 June 1984 Resolved
TOTAL PERSONS ALLOWED IS REDUCED TO A TOTAL OF 16 TILL 4 ADDITIONAL USCG APPROVED LIFEJACKETS WITH LIGHTS AND WHISTLES ARE PROVIDED ON BOARD THE VESSEL. 46 CFR 94.40. ALSO WHEN THIS IS COMPLETED NOTIFY [name withheld] PHONE [phone withheld].
Condition: Unknown
Due 29 June 1984
Resolved 29 June 1984
Electrical
Issued 29 June 1984 Resolved
MAKE OPERATIONAL THE OVERSPEED TRIP FOR THE PORT GENERATOR. 46 CFR 111.12.
Condition: Unknown
Due 29 June 1984
Resolved 29 June 1984
Unknown
Issued 29 June 1984 Resolved
THE FOLLOWING DEFICIENCIES PERTAIN TO THE VESSEL PBR/311, DN597499.
Condition: Unknown
Due 29 June 1984
Resolved 29 June 1984

Casualty record · 2

29 September 2007Routine · role: Involved in a Marine Casualty · serious marine incident, as classified · 1 injured · activity 3105801
14 August 2018Routine · role: Involved in a Marine Casualty · at RAILROAD BRIDGE ON BOEUF BAYOU, AMELIA · activity 6512017
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.