Records from 2000 to 2026. Most recent: inspection, 13 April 2026.
Documentation record
Registered dimensions (L × B × D)125.9 ft × 42.0 ft × 20.0 ft
Registered tonnagegross 294 / net 200
ITC dimensions (L × B × D)125.9 ft × 42.0 ft × 20.0 ft
ITC tonnagegross 845 / net 253
BuilderDAKOTA CREEK INDUSTRIES INC · ANACORTES, WA, UNITED STATES · built 2000
Hull materialSteel
PropulsionDiesel
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing portJACKSONVILLE, FL
Trade endorsementsCoastwise, unrestricted, Registry
DocumentationValid · issued 9 December 2025 · expires 31 January 2027
Service, as the file records itTowing Vessel
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it845 - Convention (Subpart B), Gross Ton
294 - Regulatory (Subpart C or D), Gross Ton
253 - Convention (Subpart B), Net Ton
200 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Inspection history · 42
13 April 2026
In-Service Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 8349950
13 April 2026
Type not recorded
No type recorded · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 8350754
31 March 2026
Damage Survey
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 8338631
31 March 2026
Type not recorded
No type recorded · Sector Virginia · USCG East District (CGD-E) · Activity 8340499
13 February 2026
Damage Survey · Administrative Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 8310213
13 February 2026
Type not recorded
No type recorded · Sector Virginia · USCG East District (CGD-E) · Activity 8314668
16 January 2026
Administrative Inspection
Administrative · Sector Virginia · USCG East District (CGD-E) · Activity 8297456
7 July 2025
Administrative Inspection
Administrative · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 8178022
21 May 2025
Administrative Inspection
Administrative · Sector Virginia · USCG East District (CGD-E) · Activity 8140667
24 February 2025
COI Inspection · Drydock Extension
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 8080571
26 November 2024
Damage Survey · Administrative Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 8040428
26 November 2024
Type not recorded
No type recorded · Sector Virginia · USCG East District (CGD-E) · Activity 8041792
9 May 2024
Administrative Inspection
Administrative · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 7909206
16 February 2024
MTSA/ISPS Verification
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 7866443
6 October 2023
In-Service Inspection
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 7804537
3 October 2023
MTSA Verification
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 7802789
29 September 2023
Administrative Inspection
Administrative · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 7800489
30 June 2023
Deficiency Check · Damage Survey
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7727132
19 April 2022
Initial Certification
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 7433917
31 March 2022
MTSA/ISPS Verification
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 7422264
17 September 2021
Type not recorded
No type recorded · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 7314605
1 August 2020
Type not recorded
No type recorded · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 7023576
21 November 2019
Administrative Inspection
Administrative · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6860097
1 November 2019
MTSA/ISPS Verification · Administrative Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6854865
9 May 2017
MTSA Verification
Physical examination · Marine Safety Unit Valdez · USCG Arctic District (CGD-A) · Activity 6142120
19 May 2015
MTSA/ISPS Verification
Physical examination · Marine Safety Unit Valdez · USCG Arctic District (CGD-A) · Activity 5129936
25 November 2014
Administrative Inspection
Administrative · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 5029887
20 November 2013
MTSA Verification
Physical examination · Marine Safety Unit Valdez · USCG Arctic District (CGD-A) · Activity 4756566
21 February 2013
Type not recorded
No type recorded · Marine Safety Unit Valdez · USCG Arctic District (CGD-A) · Activity 4537566
31 December 2012
Type not recorded
No type recorded · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 4509675
8 October 2012
Type not recorded
No type recorded · Marine Safety Unit Valdez · USCG Arctic District (CGD-A) · Activity 4460247
29 June 2012
Type not recorded
No type recorded · Marine Safety Unit Valdez · USCG Arctic District (CGD-A) · Activity 4361321
5 October 2010
Deficiency Check
Physical examination · Marine Safety Unit Valdez · USCG Arctic District (CGD-A) · Activity 3863784
7 June 2010
MTSA Verification
Physical examination · Marine Safety Unit Valdez · USCG Arctic District (CGD-A) · Activity 3763130
9 March 2010
Industry Initiated Exam · DAPI Audit
Physical examination · Marine Safety Unit Valdez · USCG Arctic District (CGD-A) · Activity 3694865
17 April 2008
MTSA/ISPS Verification
Physical examination · Marine Safety Unit Valdez · USCG Arctic District (CGD-A) · Activity 3186524
7 June 2005
MTSA/ISPS Verification
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 2383160
7 July 2004
MTSA Verification
Physical examination · Marine Safety Unit Valdez · USCG Arctic District (CGD-A) · Activity 2123964
30 January 2004
Security Plan Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2013579
7 May 2002
Type not recorded
No type recorded · Marine Safety Unit Valdez · USCG Arctic District (CGD-A) · Activity 1614160
17 May 2001
Type not recorded
No type recorded · Marine Safety Unit Valdez · USCG Arctic District (CGD-A) · Activity 176040
12 April 2000
Type not recorded
No type recorded · Marine Safety Unit Valdez · USCG Arctic District (CGD-A) · Activity 46962
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 13 April 2026
Resolved
Machinery and electrical systems must be designed and
maintained to provide for safe operation of the towing
vessel and safety of persons onboard under normal and
emergency conditions. #1 SSDG breaker keeps tripping and
is unable to take load. Vessel may proceed to Lake
Charles and must fix generator prior to departure.
Action required: 705 - Other - as specified
Due 20 April 2026
Resolved 5 May 2026
Resolution: ABS findings that the repairs complete.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 31 March 2026
Resolved
Machinery and electrical systems must be designed and maintained to provide for safe operation of the towing vessel and safety of persons onboard under normal and emergency conditions. MI received report from vessel captain reporting a brief loss of power due to a faulty volatge regulator.
46 CFR 143.205 (a), 16a
Action required: 16 - Rectify deficiencies w/in 14 days
Due 13 April 2026
Resolved 9 April 2026
Resolution: Preliminary report received from TPO. Findings # 114.0
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 13 February 2026
Resolved
Propulsion machinery, including main engines, reduction gears, shafting, bearings, and electrical equipment and systems, must:(1) Be maintained to ensure proper operation. Duty Marine Inspector received report of loss of propulsion on Port Z-Drive due to stripped spine gear on aqua master.
46 CFR 143.205 (c)(1)
Action required: 17 - Rectify deficiencies prior to departure
Resolved 14 February 2026
Resolution: Received finding number from TPO.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 30 June 2023
Resolved
Machinery and electrical systems must be designed and maintained to provide for safe operation of the towing vessel and safety of persons onboard under normal and emergency conditions. During outbound transit, vessel reported that the starboard main engine experienced overheating which resulted in the crew reducing propulsion and returning to Penn Terminal. Vessel is required to make repairs to the satisfaction of the TPO and provide TPO report to Sector Delaware Bay OCMI prior to departure.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 30 June 2023
Resolution: Received TPO report attesting to proper operation of starboard main engine.