SIGNET POLARIS

Built
2014
Last inspected
30 March 2026
Documentation
Valid · NVDC file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Towing Vessel class in Maury's sources begin in 1980.

Inspection record

Last inspected 30 March 2026
…with no type recorded7
Operational controls None recorded without a removal date
Years with a record 13 calendar years (2013–2026)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

9681778
WDG9593
1226777
Flag
UNITED STATES
Maury page id
psix-1226777

Documentation record

Registered dimensions (L × B × D)100.0 ft × 38.0 ft × 18.2 ft
Registered tonnagegross 476 / net 142
ITC dimensions (L × B × D)100.0 ft × 38.0 ft × 18.2 ft
ITC tonnagegross 476 / net 142
BuilderPATTI MARINE ENTERPRISES INC · PENSACOLA, FL, UNITED STATES · built 2014
Hull materialSteel
PropulsionDiesel
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing portPASCAGOULA, MS
Endorsements, as the file codes themcw_un, reg
DocumentationValid · issued 12 January 2026 · expires 28 February 2027
Service, as the file records itTowing Vessel
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it476 - Convention (Subpart B), Gross Ton
349 - Dead Weight, Gross Ton
142 - Convention (Subpart B), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Professional
The full record for this vessel

Behind this panel: 44 inspections, each with its date, unit and type; 21 deficiencies with the resolution recorded against each; operational controls, none recorded without a removal date; 9 other vessels inspected with it; no other recorded names; the documentation record: dimensions, tonnage, builder, hailing port and endorsements. Every line is a record the Coast Guard wrote; the counts above are the same counts as in the summary, and they are free.

Professional is $39 a month or $299 a year, or $19.99 a month locked for life at the founding rate, for the first 200 subscribers. It unlocks every detail section on every vessel page, fleet watch tied to your account, and ownership records on request. Already a subscriber? Sign in.

Maury does not score, rate or grade vessels, at any price.

Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 1972 to 2026, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspected as a tow unit · 9

Inspection history · 44

30 March 2026 Administrative Inspection · COI Inspection · Vessel Attendance
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 8330371
21 October 2024 Deficiency Check · Administrative Inspection · Annual Inspection
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 8035038
6 September 2024 Administrative Inspection · Deficiency Check
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 7998052
5 July 2024 Administrative Inspection · Internal Structural Exam · Drydock Exam · Examination of Repairs
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7949852
14 June 2024 Administrative Inspection · Periodic Inspection
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 7934859
25 April 2023 Annual Inspection · Administrative Inspection
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 7675656
30 March 2023 Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7659833
12 March 2023 Damage Survey · Examination of Repairs · Administrative Inspection
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 7649744
12 March 2023 Type not recorded
No type recorded · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 7850061
22 August 2022 Administrative Inspection
Administrative · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 7540822
12 July 2022 Annual Inspection · Deficiency Check · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7505225
28 June 2022 Examination of Repairs · Administrative Inspection · Internal Structural Exam · Drydock Exam
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7489391
5 May 2022 Deficiency Check
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 7444564
14 January 2022 Type not recorded
No type recorded · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 7389964
17 September 2021 Type not recorded
No type recorded · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 7314605
15 July 2021 Administrative Inspection · Deficiency Check
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 7257901
29 June 2021 Damage Survey
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 7239373
29 June 2021 Type not recorded
No type recorded · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 7300549
26 April 2021 Examination of Repairs · Administrative Inspection
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 7220392
12 April 2021 Damage Survey
Physical examination · Marine Safety Unit Victoria · USCG Heartland District (CGD-H) · Activity 7173596
30 March 2021 COI Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7165304
1 July 2020 Administrative Inspection · Damage Survey
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6992358
27 May 2020 Examination of Repairs · Damage Survey · Administrative Inspection
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 6962054
27 May 2020 Type not recorded
No type recorded · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 6962845
10 January 2020 Administrative Inspection
Administrative · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 6889181
9 January 2020 Type not recorded
No type recorded · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 6933338
28 August 2019 Hull Examination
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 6790227
19 August 2019 In-Service Inspection · Administrative Inspection
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 6791459
13 August 2019 Drydock Exam · Internal Structural Exam · MTSA Verification · COI Inspection
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 6769484
1 August 2019 Administrative Inspection
Administrative · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 6769368
5 July 2019 Administrative Inspection
Administrative · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 6744536
31 January 2019 Administrative Inspection
Administrative · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 6618012
13 July 2018 Deficiency Check
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6571366
5 July 2018 Damage Survey
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 6468010
5 July 2018 Type not recorded
No type recorded · Sector Key West · USCG Southeast District (CGD-SE) · Activity 6645133
11 May 2018 Administrative Inspection · Annual Inspection
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 6412084
11 August 2017 MTSA Verification · Annual Inspection · Deficiency Check
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 6237299
3 March 2017 Drydock Exam · Internal Structural Exam · Administrative Inspection
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 6098382
7 September 2016 Annual Inspection · MTSA Verification
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 5994866
5 May 2016 Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 5869985
28 September 2015 Annual Inspection
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 5730934
1 December 2014 Administrative Inspection
Administrative · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 5032309
11 September 2014 Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 4980503
27 February 2013 Initial Certification · ISM Oversight · MARPOL Annex V Examination · Ballast Water Examination · MARPOL Annex I Examination · Initial Construction-Excluding Oversight · Plan Review (Other than "T") · MARPOL Annex IV Survey · Construction Oversight · MARPOL Annex VI Survey · MTSA/ISPS Verification · DAPI Audit
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 4540276

Deficiency record · 21

09 - Working and Living Conditions › 092 - Working Conditions › Lighting (Working spaces)
Issued 20 June 2025 Resolved
All electrical engineering details and installations shall be designed and installed in accordance with subchapter J of this chapter. Sufficient illumination must be provided by the emergency lighting source under emergency conditions to effect damage control procedures and to provide for safe egress from each space. Area in forward stores, used for housing fire fighting gear, does not have an adequate emergency source of lighting. 90.25-1(a) 46 CFR 111.75-15(c)(2)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 20 July 2025
Resolved 3 October 2025
Resolution: Vessel submitted satisfactory photos of lighting.
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 21 June 2024 Resolved
The boundary bulkheads and decks separating the accommodations and control stations from cargo and machinery spaces, galleys, main pantries and storerooms, other than small service lockers, shall be of “A” Class construction. The EOS "A" Class Fire door has an improperly installed gasket. Repair or replace to the satisfaction of the attending USCG Marine Inspector. 46 CFR 92.07-10(c)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 21 July 2024
Resolved 12 September 2024
Resolution: Vessel installed new gaskets during drydock. All sat.
11 - Life Saving Appliances › N/A - No Subsystem › Embarkation arrangement survival craft
Issued 21 June 2024 Resolved
Each muster station and embarkation station must be adequately illuminated by lighting with power supplied from the vessel's emergency source of electrical power. Starboard embarkation light is inoperable. Repair or replace to the satisfaction of the attending USCG Marine Inspector. 46 CFR 96.06-1 46 CFR 199.110(c)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 21 July 2024
Resolved 24 August 2024
Resolution: Vessel repaired light.
11 - Life Saving Appliances › N/A - No Subsystem › Immersion suits
Issued 21 June 2024 Resolved
Each immersion suit or anti-exposure suit must be marked in such a way as to identify the person or vessel to which it belongs. Immersion suits are not appropriately marked. Rectify to the satisfaction of the attending USCG Marine Inspector. 46 CFR 96.06-1 46 CFR 199.70(c)(3)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 21 July 2024
Resolved 20 September 2024
Resolution: Received pic of immersion suit marking; all sat.
11 - Life Saving Appliances › N/A - No Subsystem › Immersion suits
Issued 21 June 2024 Resolved
Immersion suits or anti-exposure suits must have the following attachments and fittings: Each immersion suit or anti-exposure suit must have a lifejacket light approved under approval series 161.112 securely attached to the front shoulder area of the immersion suit or anti-exposure suit. Rectify to the satisfaction of the attending USCG Marine Inspector. 46 CFR 96.06-1 46 CFR 199.70(c)(4)(i)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 21 July 2024
Resolved 20 September 2024
Resolution: Received pic of immersuit suits w/ lights; all sat.
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 21 June 2024 Resolved
Demand instrumentation displays must be clearly readable and immediately available to the operator. Bridge and Engine alarm panels both display incorrect date and time for alarms. Rectify to the satisfaction of the attending USCG Marine Inspector. 46 CFR 96.03-1 46 CFR 62.25-20(c)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 21 July 2024
Resolved 20 September 2024
Resolution: Received pic of bridge panel reflecting accurate time of pic date stamp; all sat.
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 21 June 2024 Resolved
The integrity of any deck in way of a stairway opening, other than a stairtower, shall be maintained by means of “A” or “B” class bulkheads and doors at one level. The integrity of a stairtower shall be maintained by “A” Class doors at every level. The doors shall be of self-closing type. Holdback hooks, or other means of permanently holding the door open will not be permitted. Galley "A" Class door was installed with a holdback hook. Deficiency rectified. 46 CFR 92.07-10(d)(4) 46 CFR 92.07-10(g)
Action required: 10 - Deficiency Rectified
Resolved 21 June 2024
05 - Radio Communications › N/A - No Subsystem › Operation of GMDSS equipment
Issued 15 July 2022 Resolved
Radio equipment required by this subpart must be maintained to provide the availability of the functional requirements specified in § 80.1081 and to meet the performance standards specified in § 80.1101. Vessel GMDSS equipment (INMARSAT) was in error mode, and last known GMDSS (with exception of EPIRB) checks were logged in 2021. Provide objective attesting to proper function of GMDSS equipment. 47 CFR 80.1105
Action required: 17 - Rectify deficiencies prior to departure
Resolved 21 July 2022
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 15 July 2022 Resolved
Test procedure documents must be in a step-by-step or checkoff list format. Each test instruction must specify equipment status, apparatus necessary to perform the tests, safety precautions, safety control and alarm set points, the procedure to be followed, and the expected test result. Vessel was not conducting Periodic Safety Test Procedures IAW approved CG test procedures, must do so in presence of CG MI. 46 CFR 61.40-10(a)
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 21 July 2022
Resolution: Vsl demonstrated proper testing IAW approved procedures.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 12 April 2021 Resolved
Starboard shaft starting overheating. Vessel Master decided to shutdown engine to prevent any furthur damage. Vessel transited to Corpus for repairs and be cleared by Class society.
Condition: Invalid
Action required: 705 - Other - as specified
Resolved 5 May 2022
Resolution: Action must be cleared by Class Society prior to CG clearing deficency out of the system.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 30 March 2021 Resolved
Each self-propelled vessel must have duplicate light sources for the side, masthead and stern lights. Port side duplicate side light is not operational.
Condition: Damaged By Earlier Event
Action required: 16 - Rectify deficiencies w/in 14 days
Due 13 April 2021
Resolved 27 April 2021
Resolution: All duplicate lighting have been tested, all sat.
11 - Life Saving Appliances › N/A - No Subsystem › Immersion suits
Issued 30 March 2021 Resolved
Immersion suits and their locations are not reflected in the safety plan.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 13 April 2021
Resolved 27 April 2021
Resolution: Immersion Suits now reflect on safety plan.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 30 March 2021 Resolved
Provide proper seal for the vent in the starboard Z drive room.
Condition: Placed in Improper Service
Action required: 16 - Rectify deficiencies w/in 14 days
Due 13 April 2021
Resolved 27 April 2021
Resolution: Starboard Z drive room, proper vent seal has been installed.
01 - Certificates & Documentation › 013 - Documents › Survey report file
Issued 27 May 2020 Resolved
A survey, either general or partial, according to the circumstances, shall be made every time an accident occurs or a defect is discovered which affects the safety of the vessel, or whenever any important repairs or renewals are made. The survey shall be such as to insure that the necessary repairs or renewals have been effectively made, that the material and the workmanship of such repairs or renewals are in all respects satisfactory, and that the vessel complies in all respects with the regulations in this subchapter. A damage survey must be conducted to assess damage and required repairs to hull, between frames 6-35, port azimuth thruster, and fuel tank and its appurtenances. Any temporary or permanent repairs must be made to the satisfaction of the attending marine inspector. Prior to departure from current location, you are required to submit a comprehensive salvage plan for approval, including rigging of the vessel, pollution mitigation of the exposed fuel tanks, and maintaining structural/watertight integrity of the port azimuth thruster. Following salvage, you must submit a comprehensive transit plan that describes how the vessel will be moved and where the vessel will be moved to from its current location. A strict communication schedule will be established with the Coast Guard for the duration of the transit. You are not authorized to proceed until the Coast Guard has reviewed your transit plan.
Condition: Damaged By Earlier Event
Action required: 17 - Rectify deficiencies prior to departure
Due 29 May 2020
Resolved 5 May 2022
Resolution: Plans was uploaded to misle.
01 - Certificates & Documentation › 013 - Documents › Survey report file
Issued 10 January 2020 Resolved
A survey, either general or partial, according to the circumstances shall be made every time an accident occurs which affects the safety of the vessel or the completeness of its life saving appliances, fire-fighting or other equipment, or whenever any important repairs or renewal are made. Prior to movement, copies of all surveys relating to reported loss of propulsion will be provided to satisfaction of the attending Marine Inspector.
Condition: Damaged By Earlier Event
Action required: 60 - Rectify deficiencies prior to movement
Due 10 February 2020
Resolved 14 January 2020
Resolution: Vessel found bad wires and defective ECM. Tech report provided and uploaded to file.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 5 July 2018 Resolved
Vessel experienced the loss of both generators, but was able to restart generator number two. The cause of the generator loss could not be determined at sea. Vessel is to proceed to Miami to have a technician complete diagnostics on the cause of the casualty and provide a report to the local OCMI. Vessel must also demonstrate proper operation of both generators prior to departure from Miami.
Condition: Damaged By Earlier Event
Action required: 17 - Rectify deficiencies prior to departure
Due 5 August 2018
Resolved 13 July 2018
Resolution: Attended vessel and witnessed successful test of both generators. ABS report was supplied after inspection.
Fire Fighting › Structural - A Class Divisions › Machinery Spaces
Issued 11 August 2017 Resolved
Construction of vsl must be made to minimize fire hazards. Cable transit run in engine room has to be flush w/ bulkhead section. It is petruding bulkhead by 2 inches and athwartship passageway bulkhead and overhead penetration not adequate.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 11 September 2017
Resolved 6 September 2017
Resolution: All identified bulkhead and overhead penetrations repaired to the satisfaction of attending CG Marine Inspector
Lifesaving › Buoyant Apparatus › Floating Electric Waterlight
Issued 8 September 2016 Resolved
Vessel shall have 08 Life rings, 50% must be fitted with self igniting lights. Currently vessel life rings have only 25% outfitted with self igniting lights.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 18 September 2016
Resolved 11 June 2018
Resolution: Vsl installed new waterlights on liferings. 04 rings have waterlights. All sat.
Lifesaving › Buoyant Smoke Signals › General
Issued 8 September 2016 Resolved
Life Buoy with self activating smoke signals must be stowed that when released fall directly into water without striking any part of the vessel. Currently Life Buoy with smoke signal when released will land on deck and not enter water.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 18 September 2016
Resolved 11 June 2018
Resolution: Lifebuoy with smoke signal properly rigged to deploy in water. Vsl installed new bracket. Tested satisfactory.
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 8 September 2016 Resolved
Life Buoys fitted with smoke signals must also be fitted with lights. Currently Life buoys fitted with smoke signals are not fitted with lights.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 18 September 2016
Resolved 11 June 2018
Resolution: Vsl installed lights on lifebuoys with smoke signals. All satisfactory.
Lifesaving › Rescue Boat › Carriage Requirement
Issued 1 October 2015 Resolved
Vessel does not have a rescue boat and regularly engages in operations that restricts maneuverability. Vessel must submit proposal to local OCMI on how it plans to meet the requirement of a rescue boat.
Condition: Design Flaw
Action required: 705 - Other - as specified
Due 31 October 2015
Resolved 21 April 2016
Resolution: Appeal returned from District 8 accepting a rescue platform over a rescue boat