Records from 2009 to 2026. Most recent: inspection, 9 February 2026.
Documentation record
Registered dimensions (L × B × D)220.5 ft × 54.0 ft × 16.0 ft
Registered tonnagegross 1,585 / net 1,164
ITC dimensions (L × B × D)220.5 ft × 54.0 ft × 16.0 ft
ITC tonnagegross 1,999 / net 599
BuilderLEEVAC INDUSTRIES LLC · JENNINGS, LA, UNITED STATES · built 2001
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeShip
Hull configurationMonohull
Hailing portNEW ORLEANS, LA
Trade endorsementsCoastwise, unrestricted, Registry
DocumentationValid · issued 14 January 2026 · expires 28 February 2027
Service, as the file records itIndustrial Vessel
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it1585 - Regulatory (Subpart C or D), Gross Ton
1999 - Convention (Subpart B), Gross Ton
1530 - Dead Weight, Gross Ton
3930 - Displacement, Gross Ton
1164 - Regulatory (Subpart C or D), Net Ton
599 - Convention (Subpart B), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Inspection history · 24
9 February 2026
Administrative Inspection
Administrative · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 8308102
8 April 2025
Administrative Inspection
Administrative · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 8108374
7 October 2024
Deficiency Check · In-Service Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 8015833
19 August 2024
Damage Survey
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7985348
19 August 2024
Type not recorded
No type recorded · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 8026927
29 January 2024
MTSA/ISPS Verification · Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7857604
4 April 2023
Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7662410
1 April 2022
Administrative Inspection
Administrative · Sector Virginia · USCG East District (CGD-E) · Activity 7423009
30 March 2022
TPO Audit · ISM SMC Audit
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7421373
11 March 2022
Internal Structural Exam · Drydock Exam · Deficiency Check
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7396803
13 January 2022
Administrative Inspection
Administrative · USCG East District (dp) · USCG East District (CGD-E) · Activity 7379720
29 December 2021
Ballast Water Examination · COI Inspection · MTSA/ISPS Verification · MARPOL Annex IV Survey
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 7372720
29 December 2021
Internal Structural Exam
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 7372725
25 March 2021
Administrative Inspection · Annual Inspection · MTSA/ISPS Verification · DAPI Audit
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7158803
10 December 2020
Construction Oversight
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7122977
18 February 2020
Annual Inspection · Deficiency Check
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6910519
19 November 2019
Internal Structural Exam · Cargo Tank Internal · Administrative Inspection · Drydock Exam
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6858766
26 February 2019
Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6641591
17 January 2019
DAPI Audit · SIP Initial Entry · Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6611484
5 March 2018
Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6365978
12 September 2017
Type not recorded
No type recorded · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6297977
17 January 2017
Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6072064
13 December 2016
Internal Structural Exam · Drydock Exam
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 6057319
1 April 2016
Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 5845099
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 11 October 2024
Resolved
Vessel is authorized to proceed directly from Mare Island Drydock, Vallejo, CA to San Diego, CA. The vessel must meet the following conditions:
-One (01) escort tug is required while transiting within the boundary lines of San Francisco Bay.
-Two (02) escort tugs are required while transiting within the boundary lines of San Diego Bay.
-Vessel shall not transit in the waters of San Francisco Bay in less than 1/4 NM of visibility.
-The vessel shall not carry any passengers or cargo during transit.
- A 24 hr watch is required to monitor temporary repairs.
-Vessel must maintain radio check-in with nearest USCG Sector on 2-hour schedule
-The vessel shall be manned and operated in accordance with the Certificate of Inspection expiring 18 January 2027.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Resolved 17 October 2024
Resolution: Vessel has arrived safely in San Diego. Attended vessel to verify repairs.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 11 October 2024
No resolution recorded
A survey, either general or partial, according to the circumstances, shall be made every time an accident occurs or a defect is discovered which affects the safety of the vessel or the efficacy or completeness of its lifesaving appliances, fire-fighting or other equipment, or whenever any important repairs or renewals are made. The survey shall be such as to insure that the necessary repairs or renewals have been effectively made, that the material and the workmanship of such repairs or renewals are in all respects satisfactory, and that the vessel complies in all respects with the regulations in this subchapter. Vessel has inoperable stbd propulsion system due to previous marine casualty involving mooring line getting wrapped around shaft and shearing reduction gear output face. Vessel is restricted from operating in any commercial capacity until permanent repairs are witnessed by a Marine Inspector.
Condition: Damaged By Earlier Event
Action required: 701 - Prior to carriage of passengers/cargo
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 25 September 2024
Resolved
Vessel is authorized to proceed directly from San Diego, California, to Vallejo, California, at Mare Island Shipyard for the purpose of conducting repairs. The vessel must meet the following conditions:
-Two (02) escort tugs are required while operating within the boundary lines of San Diego Bay and San Francisco Bay.
-Vessel shall not transit in waters of San Francisco Bay in less than 1/4 NM of visibility.
-The vessel may not carry any passengers or cargo during transit.
-24 hr watch is required to monitor damage.
-Vessel must maintain radio check-in with nearest USCG Sector on 2 hour schedule.
-This permit expires upon arrival at Vallejo, California, or 08 October 2024, whichever occurs first.
-The vessel shall be manned and operated in accordance with the Certificate of Inspection expiring 18 January 2027.
-Coordinate oversight of repairs with local OCMI.
Condition: Damaged By Earlier Event
Action required: 15 - Rectify deficiencies by next port
Resolved 11 October 2024
Resolution: Re-issued 835 for transit back to San Diego.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 19 August 2024
Resolved
The installation of all systems of a marine engineering nature, together with the details of design, construction, and installation, shall be in accordance with the requirements of subchapter F (Marine Engineering) of this chapter. Vessel reported a line in the water that got wrapped around the stbd shaft causing damage to the main propulsion gear box. Vessel is restricted from conducting commercial operations until vessel is fully repaired. Send ABS report to local OCMI once all damage is found and once repairs are completed and approved by ABS.
46 CFR 96.03-1
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Resolved 11 October 2024
Resolution: Re-issued 835 to cover updated plans.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 19 August 2024
Resolved
Means shall be provided whereby normal operation of propulsion machinery can be sustained or restored even though one of the essential auxiliaries becomes inoperative. Special consideration shall be given to the malfunctioning of the hydraulic, pneumatic or electrical means for control in main propulsion machinery including controllable pitch propellers. However, the Administration, having regard to overall safety considerations, may accept a partial reduction in propulsion capability from normal operation. Vessel had a mooring line wrap around the starboard shaft, which caused the reduction gear box housing to crack. Vessel removed starboard shaft and blanked both sides of the shaft tube with a steel flange,bolts, gasket and 5200. Conducted permanent repairs in LA and notify local OCMI for a follow-on inspection. See page 2 for flag state dispensation.
Flag state dispensation is granted for vessel to make transit to Bollinger Fourchon or Bollinger Morgan City, LA and proceed directly to shipyard to conduct permanent repairs. Vessel is not allowed to carry passengers or work in any commercial capacity. Vessel is required to have two tugs escort them out of San Diego harbor and once in prior to arrival in new zone contact local OCMI. Vessel must ensure accepted risk assessment and mitigation measures remain in place for the duration of the voyage. Vessel must have on board a copy of Letter of Dispensation issued by Sector San Diego.
Action required: 705 - Other - as specified
Resolved 15 July 2025
Resolution: Vessel arrived to destination.
07 - Fire Safety › N/A - No Subsystem › Division - decks, bulkheads and penetrations
Issued 29 December 2021
Resolved
MCT (Multi Cable Transit) in watertight bulkhead between tank farm & bow thruster space was missing packing making it neither water tight nor meeting the fire rating of the bulkhead. Replace missing with compatible material to the existing or repack entire MCT with IMO & ABS approved material.
Action required: 705 - Other - as specified
Due 5 January 2022
Resolved 7 April 2022
Resolution: Verified multi cable transit in WTBH between tank farm and bow thruster space has been replaced with suitable approved materials. See narrative for details.
07 - Fire Safety › N/A - No Subsystem › Division - decks, bulkheads and penetrations
Issued 29 December 2021
Resolved
MCT (Multi Cable Transit) in watertight bulkhead between Engine room & tank farm has mis-matched materials. Prove compatibility of materials use or re-pack with IMO & ABS approved material that meet fire rating and for watertight bulkheads.
Action required: 705 - Other - as specified
Due 5 January 2022
Resolved 7 April 2022
Resolution: Verified multi cable transit in WTBH between engine room and tank farm space has been replaced with suitable, approved materials. See narrative for details.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 18 February 2020
Resolved
Install cable supports for PAM power supply cables on starboard side. Due 18Mar2020.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 18 March 2020
Resolved 5 March 2020
Resolution: Cable supports installed.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 18 February 2020
Resolved
Provide calibrated testing device to complete Periodic Safety Test Procedures for temperature alarms on generator and main engines IAW approved procedures. Device should either be EMI part No. 17500 or Hart scientific model 9141 dry well calibrator or equal.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 18 March 2020
Resolved 5 March 2020
Resolution: Calibrated device provided.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 18 February 2020
Resolved
Provide hand pump or calibrated pressure gauge IAW approved PSTP's to perform loss of lube oil pressure on main engines and generators.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 18 March 2020
Resolved 5 March 2020
Resolution: Calibrated device provided. PSTP completed.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Gauges, thermometers, etc
Issued 18 February 2020
Resolved
Provie calibrated gauges for start air pressure PSTP alarm.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 18 March 2020
Resolved 5 March 2020
Resolution: Gauges calibrated.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 18 February 2020
Resolved
Provide approved Caterpillar bushing/chafe gear for fuel line support brackets on starboard main engine.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 18 March 2020
Resolved 5 March 2020
Resolution: Proper chafing gear provided.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 17 January 2019
Resolved
Vessel's crew demonstrated low/no competency or knowledge in carrying out the processes of the SIP program in the areas of using the required check sheets & procedures specific to the CO2 fixed systems of the engine room and paint locker as well as the the automatic and manual dampeners.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 17 February 2019
Resolved 22 January 2019
07 - Fire Safety › N/A - No Subsystem › Fire-dampers
Issued 17 January 2019
Resolved
Provide proper installation of the engine room fire damper screen.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 17 February 2019
Resolved 22 January 2019
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 17 January 2019
Resolved
Provide documentation form the SIP Rep from teh company attesting to a successful internal SIP audit.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 22 February 2019
Resolved 22 February 2019
Resolution: Voluntary SIP disenrollment.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 17 January 2019
Resolved
Provide SIP training certificates for vessel crew.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 22 February 2019
Resolved 22 February 2019
Resolution: Voluntary SIP disenrollment.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 17 January 2019
Resolved
Provide new CAP amd VAP for approval.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 22 February 2019
Resolved 22 February 2019
Resolution: Voluntary SIP disenrollment.