Records from 2002 to 2026. Most recent: inspection, 11 February 2026.
Documentation record
Registered dimensions (L × B × D)241.0 ft × 60.0 ft × 20.6 ft
Registered tonnagegross 2,520 / net 756
ITC dimensions (L × B × D)241.0 ft × 60.0 ft × 20.6 ft
ITC tonnagegross 2,520 / net 756
BuilderLEEVAC INDUSTRIES LLC · JENNINGS, LA, UNITED STATES · built 2002
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portNEW ORLEANS, LA
Trade endorsementsCoastwise, unrestricted, Registry
DocumentationValid · issued 21 July 2026 · expires 31 August 2027
Service, as the file records itIndustrial Vessel
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it2520 - Convention (Subpart B), Gross Ton
756 - Convention (Subpart B), Net Ton
3714 - Dead Weight, Metric Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Inspection history · 49
11 February 2026
In-Service Inspection · Administrative Inspection · MTSA/ISPS Verification
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 8310562
27 September 2025
Type not recorded
No type recorded · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 8245351
30 July 2025
ACP Annual Oversight · Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 8198237
23 October 2024
MTSA/ISPS Verification · ACP Handover Survey · Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 8023334
7 March 2024
Administrative Inspection
Administrative · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7875758
14 November 2023
Damage Survey · Administrative Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7824319
26 July 2023
COI Inspection · Annual Inspection · MTSA/ISPS Verification
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7752622
21 July 2023
Damage Survey
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7748741
12 May 2023
Damage Survey · Administrative Inspection · Drydock Exam
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7686886
11 May 2023
Type not recorded
No type recorded · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7694747
11 January 2023
Periodic Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7619747
12 January 2022
Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7379028
19 October 2021
Internal Structural Exam · Drydock Exam · Damage Survey
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 7335744
22 February 2021
MTSA/ISPS Verification · MARPOL Annex I Examination · COI Inspection · MARPOL Annex VI Survey
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7143643
7 April 2020
Administrative Inspection
Administrative · Commandant (CG-CVC) · Activity 6940161
25 October 2019
Administrative Inspection · Deficiency Check
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6841488
28 August 2019
COI Inspection · Drydock Exam · Administrative Inspection · Internal Structural Exam · MARPOL Annex I Examination · MTSA/ISPS Verification · MARPOL Annex VI Survey
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 6797428
6 August 2019
Administrative Inspection
Administrative · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6775031
21 August 2017
Administrative Inspection
Administrative · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6247654
17 August 2015
MARPOL Annex I Examination · Administrative Inspection · SIP Inspection/Audit
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 5218484
3 August 2015
In-Service Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 5205097
17 October 2014
Type not recorded
No type recorded · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 5010928
24 June 2014
SIP Inspection/Audit · Periodic Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 4897188
18 July 2012
SIP Initial Entry · Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 4382736
11 June 2012
Internal Structural Exam · Hull Examination · COI Inspection · Administrative Inspection · Drydock Exam
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 4341197
19 September 2011
Administrative Inspection
Administrative · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 4146797
31 August 2011
Annual Inspection · MTSA/ISPS Verification
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 4131087
27 July 2009
Damage Survey
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3548396
27 July 2009
Type not recorded
No type recorded · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3549420
9 July 2009
Re-Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3528327
19 February 2009
In-Service Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3420959
18 September 2008
Re-Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3340978
14 September 2008
Type not recorded
No type recorded · Sector Mobile · USCG Heartland District (CGD-H) · Activity 3337599
2 July 2007
MARPOL Annex II Examination · Internal Structural Exam · COI Inspection · Hull Examination · MTSA/ISPS Verification
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 2980526
14 August 2006
Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2744266
31 January 2006
Administrative Inspection
Administrative · Marine Safety Center (MSC) · Activity 2576487
31 January 2006
Security Plan Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2576495
16 September 2005
Administrative Inspection · Re-Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2501195
20 June 2005
Hull Examination · Internal Structural Exam
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 2397041
8 June 2005
Drydock Extension · Administrative Inspection
Administrative · MSU LAKE CHARLES · USCG Heartland District (CGD-H) · Activity 2383941
4 June 2004
MTSA/ISPS Verification
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2088662
27 May 2004
Administrative Inspection · Re-Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2079655
25 May 2004
Administrative Inspection
Administrative · MIDET EAST BANK DETAIL · USCG Heartland District (CGD-H) · Activity 2077837
20 April 2004
Security Plan Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2048393
29 December 2003
Security Plan Review - ASP
Administrative · Marine Safety Center (MSC) · Activity 1979364
11 September 2003
Administrative Inspection
Administrative · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 1902372
15 October 2002
Administrative Inspection
Administrative · MSU LAKE CHARLES · USCG Heartland District (CGD-H) · Activity 1690106
9 September 2002
Administrative Inspection
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1673121
3 June 2002
Inclining Experiment · Construction Oversight · Initial Certification
Physical examination · MSU LAKE CHARLES · USCG Heartland District (CGD-H) · Activity 1625476
14 - Pollution Prevention › 141 - MARPOL Annex I › 15 PPM Alarm arrangements
Issued 3 August 2023
Resolved
No oceangoing ship may operate unless fitted with approved 15 ppm OWS; OWS inoperable. Rectify prior to int'l voyage.
33 CFR 155.360
Condition: Improper/Lack of Maintenance
Action required: 702 - Prior to embarking on international voyage
Resolved 10 August 2023
Resolution: OWS repaired.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 26 July 2023
Resolved
Each vessel must be designed and constructed to minimize fire hazards. Approximately 6" of the insulation in the emergency generator space was rotted out.
46 CFR 127.220(a)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 25 August 2023
Resolved 3 August 2023
Resolution: Insulation replaced.
10 - Safety of Navigation › N/A - No Subsystem › Other (navigation)
Issued 12 May 2023
Resolved
Except as provided, machinery must comply with subchapter F; vessel lost stbd propeller and is no longer in compliance. Vessel is permitted to locally shift with tug support to drydock for repairs in Port Fourchon.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 26 July 2023
Resolution: Shaft repaired
09 - Working and Living Conditions › 092 - Working Conditions › Machinery
Issued 11 January 2023
Resolved
Auxiliary steering system gear shall be of adequate strength and capable of steering the ship at navigable speed and of being brought into action in an emergency; control power failure on port pump and inop stbd nfu control while operating aft steering.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 11 January 2023
Resolution: Issue discovered to be failure to switch to local controls; steering gear operational.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 11 January 2023
Resolved
Electrical pwoer should be suficient for 18h emergency lighting in machinery spaces and exits; four (04) e-lights found inop, one (01) was flickering.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 10 February 2023
Resolved 17 January 2023
Resolution: E-lighting fixed.
11 - Life Saving Appliances › N/A - No Subsystem › Launching arrangements for rescue boats
Issued 12 January 2022
Resolved
Each davit must be inspected and repaired as needed. The rescue boat davit brake was inoperable because the counterweight was seized. Error was fixed during the inspection.
Action required: 10 - Deficiency Rectified
Due 12 January 2022
Resolved 12 January 2022
03 - Water/Weathertight Conditions › N/A - No Subsystem › Cargo ports and other similar openings
Issued 19 October 2021
Resolved
A bilge pipe piercing the collision bulkhead must be fitted with a screw down valve located on the forward side of the collision bulkhead and operable from the weather deck or if not readily accessible a screw down valve without a reach rod. The valve and reach rod are corroded and unserviceable.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 9 November 2021
Resolved 2 November 2021
Resolution: ABS witnessed installation of new valve and reach rod.
02 - Structural Conditions › N/A - No Subsystem › Hull damage impairing seaworthiness
Issued 19 October 2021
Resolved
Vessel sustained damage to the entire portside of the vessel and a small area on the starboardside from Hurricane Ida. All damaged sideshell and internal structural members need to be cropped and renewed, replaced in kind.
Condition: Damaged By Earlier Event
Action required: 17 - Rectify deficiencies prior to departure
Due 9 November 2021
Resolved 2 November 2021
Resolution: ABS and CG completed oversight of all repairs to the sideshell and internal structural members.
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 22 February 2021
Resolved
Vessel shall maintain a valid Certificate of Inspection by completing the annual and periodic inspections within the 3 months of the Anniversary Date. Vessel exceeded the 3 month Anniversary Date by over one month.
Action required: 10 - Deficiency Rectified
Due 22 February 2021
Resolved 22 February 2021
Resolution: Vessel completed Inspection for Certification (COI) and issued new COI.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 22 February 2021
Resolved
Vessel shall ensure that non-metallic fuel oil hoses do not exceed 30 inches. Vessel had one hose on each of the Fire Fighting Monitor Engine that exceeded 30 inches.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 24 March 2021
Resolved 25 February 2021
Resolution: Vessel corrected deficiency by installing steel fuel lines piping to minimize the size of non-metallic fuel hoses.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 28 August 2019
Resolved
The emergency generator set must shut down automatically upon operation of a fixed fire extinguishing system in the emergency generator room.
Emergency generator failed to shut down folliwng the operation of the fixed fire extinguishing system.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 17 November 2019
Resolved 25 October 2019
Resolution: USCG MI witnessed proper operation of CO2 shutdown for E-Gen.
Lifesaving › Inflatable Liferafts › Hydrostatic Release Unit
Issued 17 August 2015
Resolved
Life Raft strap was secured so tightly that the pelican hook could not be release to manually launch liferaft.
Due 18 August 2015
Resolved 18 August 2015
Resolution: Corrected on spot
Lifesaving › Rescue Boat Equipment › Searchlight
Issued 17 August 2015
Resolved
Search light could not be plugged in to current configuration of rescue boat.
Due 18 August 2015
Resolved 18 August 2015
Resolution: Master placed order with company and filled out proper Corrective Action form in accordance with that ICR.
Lifesaving › Rescue Boat Equipment › Electric Torch
Issued 17 August 2015
Resolved
Batteries Dead
Due 18 August 2015
Resolved 18 August 2015
Resolution: New Batteries were installed
Pollution Prevention/Response › Prevention Equipment › Oily Water Separator (15 ppm)
Issued 17 August 2015
Resolved
Solenoid valve for Overboard discharge would not completely close upon OCM reaching 15 ppm.
Due 19 August 2015
Resolved 19 August 2015
Resolution: Valve replaced, and test witnessed by [name withheld] and [name withheld].
Lifesaving › Rescue Boat Equipment › Bucket (rigid rescue boat)
Issued 24 June 2014
Resolved
Bucket and Knife Missing from equipment.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 24 June 2014
Pollution Prevention/Response › Prevention Equipment › Oily Water Separator (15 ppm)
Issued 24 June 2014
Resolved
Overboard discharge valve did not seat allowing water to flow above 15 ppm test.
Action required: 705 - Other - as specified
Resolved 24 June 2014
Resolution: Valve repalced and tested sat.
Navigation › Emergency Steering › Communications to Emergency Steering
Issued 24 June 2014
Resolved
rudder indicators between the bridge and emergency steering station variance of 15 +.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 25 June 2014
Resolution: Tech repaired the unit.
Construction/Loadline › Hull › Hull Plating
Issued 27 July 2009
Resolved
Vessel has inset plating on the bow w/crack following an allision from another vessel.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Resolved 27 July 2009
Resolution: Cracked plating was welded and checked by ABS. Vessel will be inserting new plate at the next drydock in June 2010.