Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Miscellaneous Vessel class in Maury's sources begin in 2016.
Every line above is a count of records the US Coast Guard wrote, or a date it recorded.
A blank resolution means none was recorded in this data; it does not establish that a
deficiency is outstanding. Years with a record are calendar years in which a record
exists, not years in service. What Maury does
not do.
Registered dimensions (L × B × D)241.0 ft × 60.0 ft × 20.6 ft
Registered tonnagegross 2,520 / net 756
ITC dimensions (L × B × D)241.0 ft × 60.0 ft × 20.6 ft
ITC tonnagegross 2,520 / net 756
BuilderLEEVAC INDUSTRIES LLC · JENNINGS, LA, UNITED STATES · built 2002
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing portNEW ORLEANS, LA
Endorsements, as the file codes themcw_un, reg
DocumentationValid · issued 21 July 2026 · expires 31 August 2027
Service, as the file records itIndustrial Vessel
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it2520 - Convention (Subpart B), Gross Ton 756 - Convention (Subpart B), Net Ton 3714 - Dead Weight, Metric Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Professional
The full record for this vessel
Behind this panel: 19 inspections, each with its date, unit and type; 11 deficiencies with the resolution recorded against each; operational controls, none recorded without a removal date; no tow-unit appearances recorded; no other recorded names; the documentation record: dimensions, tonnage, builder, hailing port and endorsements. Every line is a record the Coast
Guard wrote; the counts above are the same counts as in the summary, and they are free.
Professional is $39 a month or $299 a year,
or $19.99 a month locked for life at the founding rate, for the first 200 subscribers. It unlocks
every detail section on every vessel page, fleet watch tied to your account, and ownership records
on request. Already a subscriber? Sign in.
Maury does not score, rate or grade vessels, at any price.
Vessel history report
Every record for this hull, in one document — $299
Every recorded inspection, 1972 to
2026, in one chronology · every deficiency, with system, dates
and resolution · operational controls imposed and removed · every name this
hull has been recorded under · the vessels it was inspected alongside, and when
· how its record compares with hulls of similar age and size, as a fact about the
population and never a judgement about this vessel.
This report is in development and is not for sale yet. There is
no date, and nothing is charged. Leave an email and we will tell you when it exists, once.
Used only to tell you when the report exists.
Not shared, not sold, and not added to a mailing list.
Inspection history · 19
11 February 2026In-Service Inspection · Administrative Inspection · MTSA/ISPS Verification
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 8310562
27 September 2025Type not recorded
No type recorded · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 8245351
30 July 2025ACP Annual Oversight · Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 8198237
No oceangoing ship may operate unless fitted with approved 15 ppm OWS; OWS inoperable. Rectify prior to int'l voyage.
33 CFR 155.360
Condition: Improper/Lack of Maintenance
Action required: 702 - Prior to embarking on international voyage
Resolved 10 August 2023
Resolution: OWS repaired.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 26 July 2023Resolved
Each vessel must be designed and constructed to minimize fire hazards. Approximately 6" of the insulation in the emergency generator space was rotted out.
46 CFR 127.220(a)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 25 August 2023
Resolved 3 August 2023
Resolution: Insulation replaced.
10 - Safety of Navigation › N/A - No Subsystem › Other (navigation)
Issued 12 May 2023Resolved
Except as provided, machinery must comply with subchapter F; vessel lost stbd propeller and is no longer in compliance. Vessel is permitted to locally shift with tug support to drydock for repairs in Port Fourchon.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 26 July 2023
Resolution: Shaft repaired
09 - Working and Living Conditions › 092 - Working Conditions › Machinery
Issued 11 January 2023Resolved
Auxiliary steering system gear shall be of adequate strength and capable of steering the ship at navigable speed and of being brought into action in an emergency; control power failure on port pump and inop stbd nfu control while operating aft steering.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 11 January 2023
Resolution: Issue discovered to be failure to switch to local controls; steering gear operational.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 11 January 2023Resolved
Electrical pwoer should be suficient for 18h emergency lighting in machinery spaces and exits; four (04) e-lights found inop, one (01) was flickering.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 10 February 2023
Resolved 17 January 2023
Resolution: E-lighting fixed.
11 - Life Saving Appliances › N/A - No Subsystem › Launching arrangements for rescue boats
Issued 12 January 2022Resolved
Each davit must be inspected and repaired as needed. The rescue boat davit brake was inoperable because the counterweight was seized. Error was fixed during the inspection.
Action required: 10 - Deficiency Rectified
Due 12 January 2022
Resolved 12 January 2022
03 - Water/Weathertight Conditions › N/A - No Subsystem › Cargo ports and other similar openings
Issued 19 October 2021Resolved
A bilge pipe piercing the collision bulkhead must be fitted with a screw down valve located on the forward side of the collision bulkhead and operable from the weather deck or if not readily accessible a screw down valve without a reach rod. The valve and reach rod are corroded and unserviceable.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 9 November 2021
Resolved 2 November 2021
Resolution: ABS witnessed installation of new valve and reach rod.
Vessel sustained damage to the entire portside of the vessel and a small area on the starboardside from Hurricane Ida. All damaged sideshell and internal structural members need to be cropped and renewed, replaced in kind.
Condition: Damaged By Earlier Event
Action required: 17 - Rectify deficiencies prior to departure
Due 9 November 2021
Resolved 2 November 2021
Resolution: ABS and CG completed oversight of all repairs to the sideshell and internal structural members.
Vessel shall maintain a valid Certificate of Inspection by completing the annual and periodic inspections within the 3 months of the Anniversary Date. Vessel exceeded the 3 month Anniversary Date by over one month.
Action required: 10 - Deficiency Rectified
Due 22 February 2021
Resolved 22 February 2021
Resolution: Vessel completed Inspection for Certification (COI) and issued new COI.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 22 February 2021Resolved
Vessel shall ensure that non-metallic fuel oil hoses do not exceed 30 inches. Vessel had one hose on each of the Fire Fighting Monitor Engine that exceeded 30 inches.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 24 March 2021
Resolved 25 February 2021
Resolution: Vessel corrected deficiency by installing steel fuel lines piping to minimize the size of non-metallic fuel hoses.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 28 August 2019Resolved
The emergency generator set must shut down automatically upon operation of a fixed fire extinguishing system in the emergency generator room.
Emergency generator failed to shut down folliwng the operation of the fixed fire extinguishing system.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 17 November 2019
Resolved 25 October 2019
Resolution: USCG MI witnessed proper operation of CO2 shutdown for E-Gen.
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.