Built
1980
Last inspected
22 June 2026
Documentation
Valid · NVDC file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Miscellaneous Vessel class in Maury's sources begin in 2016.

Inspection record

Last inspected 22 June 2026
…past their stated due date1
Operational controls None recorded without a removal date
Years with a record 11 calendar years (2016–2026)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

WAS9972
Flag
UNITED STATES
Maury page id
psix-51207

Documentation record

Registered dimensions (L × B × D)248.0 ft × 56.0 ft × 17.4 ft
Registered tonnagegross 2,060 / net 2,060
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderGALVESTON SHIPBUILDING · GALVESTON, TX, UNITED STATES · built 1980
Hull materialSteel
PropulsionNone
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing portPORTLAND, OR
Endorsements, as the file codes themcw_un, reg
DocumentationValid · issued 4 March 2026 · expires 31 March 2027
Service, as the file records itOil Recovery
Hull formbarge (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it2060 - Regulatory (Subpart C or D), Gross Ton
2060 - Regulatory (Subpart C or D), Net Ton
8169 - Dead Weight, Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Professional
The full record for this vessel

Behind this panel: 13 inspections, each with its date, unit and type; 13 deficiencies with the resolution recorded against each, 1 without one; operational controls, none recorded without a removal date; no tow-unit appearances recorded; 1 other recorded name; the documentation record: dimensions, tonnage, builder, hailing port and endorsements. Every line is a record the Coast Guard wrote; the counts above are the same counts as in the summary, and they are free.

Professional is $39 a month or $299 a year, or $19.99 a month locked for life at the founding rate, for the first 200 subscribers. It unlocks every detail section on every vessel page, fleet watch tied to your account, and ownership records on request. Already a subscriber? Sign in.

Maury does not score, rate or grade vessels, at any price.

Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 1972 to 2026, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspection history · 13

22 June 2026 Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 8410598
25 June 2025 Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 8167503
30 May 2024 Internal Structural Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7924110
20 January 2023 MTSA Verification · COI Inspection · Deficiency Check
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7624711
27 April 2022 Drydock Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7433601
11 August 2021 Administrative Inspection · Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7286117
22 July 2020 MARPOL Annex I Examination · COI Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7012414
24 June 2019 Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6723729
1 April 2019 Internal Structural Exam · Drydock Exam · Cargo Tank Internal
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6654051
28 March 2018 Administrative Inspection · Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6382158
13 July 2017 Drydock Exam · Administrative Inspection · Internal Structural Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6306332
22 August 2016 Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 5974644
7 March 2016 Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 5834344

Deficiency record · 13

13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 25 June 2025 Resolved
Fuel supply and return hoses to the generator are not fire rated and do not meet SAE J1942. Provide fuel hose listed in SAE J1942-1 that is fire rated with hose end fittings that meet SAE J1475. 56.60-25(b)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 25 July 2025
Resolved 15 July 2026
Resolution: Hoses replaced.
09 - Working and Living Conditions › 092 - Working Conditions › Pipes, wires (insulation)
Issued 25 June 2025 Resolved
Generator exhaust piping is uninsulated. Provide proper insulation for exposed exhaust piping. 46 CFR 56.50-1(k)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 25 June 2025
Resolved 15 July 2026
Resolution: Lagging installed.
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 30 May 2024 Resolved
Vessel must undergo an annual inspection within 3 months before or after each anniversary date. Vessel outside window (COI date 20JAN2023)and must submit a 3752/Application for inspection prior to carriage of cargo.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 13 June 2024
Resolved 25 June 2025
Resolution: New COI issued in July 2024, def not cleared erroneously. Cleared in this activity.
14 - Pollution Prevention › 141 - MARPOL Annex I › Other (MARPOL Annex I)
Issued 20 January 2023 Resolved
Emergency pump shut off installed at the manifold on the cargo deck failed to secure the cargo pump engine. Provide a functioning cargo pump emergency shut off prior to cargo operations.
Action required: 705 - Other - as specified
Due 28 February 2023
Resolved 25 June 2025
Resolution: Tested sat.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 20 January 2023 No resolution recorded
Modifications have been made to the Coast Guard approved electrical plant. Prior to operating the new equipment submit plans of the modifications to Marine Safety Center (MSC) for review and approval. Submitted plans shall demonstrate compliance with 46 CFR Subchapter J. Once approved plans are returned from MSC the installation shall be inspected by an attending Marine Inspector prior to placing it into service.
Action required: 705 - Other - as specified
Due 28 February 2023 — due date passed with no resolution recorded
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 11 August 2021 Resolved
Lube oil and fuel lines should be replaced on prime mover w/fire retardant hoses or be provided with approved fire sleeves. 32.35-1
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 20 January 2023
Resolution: Equipment removed from vessel.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 11 August 2021 Resolved
Low oil alarm missing and needs to be reinstalled on prime mover.32.35-1
Condition: Invalid
Action required: 705 - Other - as specified
Resolved 20 January 2023
Resolution: Equipment removed from vessel.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Gauges, thermometers, etc
Issued 11 August 2021 Resolved
Gauges are not working for generator, need to be installed/repaired. 32.35-1
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 20 January 2023
Resolution: Equipment removed from vessel.
Electrical › Electrical Distribution System (service) › Wiring
Issued 28 March 2018 Resolved
Port Side of Machinery space has large ammount of dead end wires as a result of Port Generator no longer in service. Remove wires or terminate them in junction box to the satisfaction of Marine Inspector.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 28 April 2018
Resolved 11 April 2018
Resolution: All dead end wires were removed. all items sat.
Stability › Watertight Integrity › General
Issued 28 March 2018 Resolved
Watertight doors on machinery space were not vapor tight. Inspect and renew all 3 watertight doors as necessary to the satisfaction of CG Marine Inspector.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 28 April 2018
Resolved 11 April 2018
Resolution: Three WTD's were repaired by replacing gasket seal. All 3 WTD's found sat.
Accommodation/Occupational Safety › Ventilation › General
Issued 22 August 2016 Resolved
All goose neck vents must have means of closure. 46 CFR 92.15-10(a)
Action required: 705 - Other - as specified
Due 22 September 2016
Resolved 22 September 2016
Resolution: Received email correspondence with pictures.
Electrical › Lighting (service) › Lighting Fixture
Issued 22 August 2016 Resolved
Install high strength guards over light fixtures in machinery space and spaces adjacent. 46 CFR 111.75-20(b)
Action required: 705 - Other - as specified
Due 22 September 2016
Resolved 22 September 2016
Resolution: Received email correspondence with pictures.
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 22 August 2016 Resolved
Install guard over generator's rotating machinery. 46 CFR 58.01-20
Action required: 705 - Other - as specified
Due 22 September 2016
Resolved 22 September 2016
Resolution: Received email correspondence with pictures.

Recorded names · 1

FOSS 248-P3 (2002–2007). Names as the Coast Guard recorded them in incident records, with the years they appear; some are renames and some are spelling variants.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.