Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Towing Vessel class in Maury's sources begin in 1980.
Every line above is a count of records the US Coast Guard wrote, or a date it recorded.
A blank resolution means none was recorded in this data; it does not establish that a
deficiency is outstanding. Years with a record are calendar years in which a record
exists, not years in service. What Maury does
not do.
Registered dimensions (L × B × D)66.7 ft × 24.0 ft × 8.0 ft
Registered tonnagegross 96 / net 65
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderALBINA ENGINE & MACHINE · PORTLAND, OR, UNITED STATES · built 1968
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing portKETCHIKAN, AK
Endorsements, as the file codes themcw_un, reg
DocumentationValid · issued 22 June 2026 · expires 30 June 2027
Service, as the file records itTowing Vessel
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it65 - Regulatory (Subpart C or D), Net Ton 96 - Regulatory (Subpart C or D), Gross Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Professional
The full record for this vessel
Behind this panel: 22 inspections, each with its date, unit and type; 13 deficiencies with the resolution recorded against each; operational controls, none recorded without a removal date; 3 other vessels inspected with it; no other recorded names; the documentation record: dimensions, tonnage, builder, hailing port and endorsements. Every line is a record the Coast
Guard wrote; the counts above are the same counts as in the summary, and they are free.
Professional is $39 a month or $299 a year,
or $19.99 a month locked for life at the founding rate, for the first 200 subscribers. It unlocks
every detail section on every vessel page, fleet watch tied to your account, and ownership records
on request. Already a subscriber? Sign in.
Maury does not score, rate or grade vessels, at any price.
Vessel history report
Every record for this hull, in one document — $299
Every recorded inspection, 1972 to
2026, in one chronology · every deficiency, with system, dates
and resolution · operational controls imposed and removed · every name this
hull has been recorded under · the vessels it was inspected alongside, and when
· how its record compares with hulls of similar age and size, as a fact about the
population and never a judgement about this vessel.
This report is in development and is not for sale yet. There is
no date, and nothing is charged. Leave an email and we will tell you when it exists, once.
Used only to tell you when the report exists.
Not shared, not sold, and not added to a mailing list.
The Coast Guard recorded this vessel and the following in the same
inspection activity — normally a tug and the barges in its tow. A recreational or
unclassed hull in the same activity is held and not published, so it does not appear
here: these lists are a floor, not a complete manifest.
11 - Life Saving Appliances › N/A - No Subsystem › Line-throwing appliance
Issued 5 May 2025Resolved
Each towing vessel operating in oceans and coastwise service must have a line throwing appliance approved under approval series 160.040- Four rocket projectiles, each complete with bridle and leader of fire-resistant materials. Two of the projectiles shall be of the buoyant type.
Additional equipment: The line throwing appliance must have:(1) The equipment on the list provided by the manufacturer with the approved appliance; and(2) An auxiliary line that:(i) Is at least 450 meters (1,500 feet) long;(ii) Has a breaking strength of at least 40 kilonewtons (9,000 pounds-force); and(iii) Is, if synthetic, of a dark color or certified by the manufacturer to be resistant to deterioration from ultraviolet light.
Vessel is certified for coastwise routes and is equipped with 01 line throwing device and no axillary line.
Condition: Placed in Improper Service
Action required: 50 - Rectify deficiencies w/in 30 days
Due 14 June 2025
Resolved 10 June 2025
Resolution: O/O has added two Ikaros Line throwers, two buoyant heads, and the auxiliary line to vessel. All Sat.
07 - Fire Safety › N/A - No Subsystem › Ready availability of fire fighting equipment
Issued 25 April 2022Resolved
Portable fire extinguishers on board found to be out of service with 01 portable extinguisher gauge in the bridge indicating low psi and requiring recharge. Portable and semi-portable fire extinguishers must be inspected, maintained, and tested in accordance with the requirements of Chapter 7 and 8 of NFPA 10. Provide servicing certificate to marine inspector.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 9 May 2022
Resolved 12 May 2022
Resolution: Received fire equipment sevicing certificates.
14 - Pollution Prevention › 141 - MARPOL Annex I › Segregation of oil and water ballast
Issued 25 April 2022Resolved
Unauthorized clear-well located in the aft portion of the ENG RM. No person may operate an oceangoing ship of less than 400 GT unless it has the capacity to retain oily-mixtures on board and equipped to discharge to a reception facility or if it has approved OWS equipment for processing oily mixtures for discharge into the sea. Clear-well or bilge water practices shall be modified to the satisfaction of a marine inspector.
Condition: Design Flaw
Action required: 16 - Rectify deficiencies w/in 14 days
Due 9 May 2022
Resolved 12 May 2022
Resolution: Equipment removed.
11 - Life Saving Appliances › N/A - No Subsystem › Line-throwing appliance
Issued 24 June 2020Resolved
Provide Line Throwing Appliance for vessel as required by and meeting the requirements of 46 CFR 141.385.
46 CFR 141.385
Action required: 50 - Rectify deficiencies w/in 30 days
Due 24 July 2020
Resolved 2 July 2020
Resolution: Provided photograph
14 - Pollution Prevention › 141 - MARPOL Annex I › Pumping, piping and discharge arrangements
Issued 24 June 2020Resolved
Designate in writing person in charge (PIC) of fueling transfer operations.
33 CFR 155.700
33 CFR 155.715
Action required: 50 - Rectify deficiencies w/in 30 days
Due 24 July 2020
Resolved 2 July 2020
Resolution: Provided document
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 24 June 2020Resolved
Provide evidence of record of inspection, testing and maintenance of applicable lifesaving equipment as required by 46 CFR 141.235. Requirements for weekly, monthly and annual required servicing is provided in 46 CFR 199.190.
46 CFR 141.235
46 CFR 199.190
Action required: 50 - Rectify deficiencies w/in 30 days
Due 24 July 2020
Resolved 2 July 2020
Resolution: Provided photograph
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 24 June 2020Resolved
Label engine room and pilothouse escape hatches as required by 46 CFR 144.160 (f).
46 CFR 144.160 (f)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 24 July 2020
Resolved 2 July 2020
Resolution: Provided photograph
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 24 June 2020Resolved
Repair or replace temporary battery charger in FWD Starboard engine.
Extended due to lead time on component.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 24 July 2020
Resolved 12 August 2020
Resolution: Temp charging system replaced w/ permanent.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 24 June 2020Resolved
Install insulation (lagging) on main diesel engine
turbochargers for areas exceeding 428 degrees F as
required by 46 CFR 143.220(b).
46 CFR 143.220(b
Action required: 50 - Rectify deficiencies w/in 30 days
Due 24 June 2020
Resolved 2 July 2020
Resolution: Provided photograph
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 24 June 2020Resolved
Install cover missing from electrical outlet above fire pump centerline aft of engine room.
46 CFR 143.300
Action required: 50 - Rectify deficiencies w/in 30 days
Due 24 July 2020
Resolved 7 July 2020
Operations/Management › Drug and Alcohol Testing › EAP Display Requirements
Issued 28 February 2011Resolved
DER could not provide evidence of a satisfactory EAP
Action required: 705 - Other - as specified
Due 28 March 2011
Resolved 28 February 2011
Resolution: Satisfactory EAP provided.
Navigation
Issued 13 October 1986Resolved
VESSEL WAS MISSING SHIP'S BELL AS REQUIRED BY COLREGS RULE 33. A VESSEL OF 12 METERS OR MORE IN LENGTH SHALL BE PROVIDED WITH A WHISTLE AND A BELL. THE VESSEL "DEAN FOSS" IS OVER 20 METERS LONG.
Condition: Unknown
Due 18 May 2002
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Documentation
Issued 13 October 1986Resolved
VESSELS OTP WAS INCOMPLETE. VESSEL WAS LACKING PROCEDURES 33 155.750(3-9) AS REQUIRED BY 33 CFR 155.750.
Condition: Unknown
Due 18 May 2002
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.