MAURY USCG vessel records Sign in
← All vessels

EL PATRON

EL PATRON is a 1977 passenger vessel (inspected). The Coast Guard has recorded 67 inspections since 1985, most recently in September 2025, along with 55 deficiencies.

Records from 1985 to 2025. Most recent: inspection, 3 September 2025.

Built
1977
Last inspected
3 September 2025
Documentation
Valid · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WDC6120
Flag
UNITED STATES
366915000
Maury page id
psix-51266

Inspections, by type

…with no type recorded4
Years with a record 38 calendar years (1985–2025)
The 67 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Registered dimensions (L × B × D)47.5 ft × 15.7 ft × 6.7 ft
Registered tonnagegross 37 / net 26
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderDELTA MARINE INDUSTRIES · SEATTLE, WA, UNITED STATES · built 1977
Hull materialFRP (Fiberglass)
PropulsionDiesel Reduction
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portSAN DIEGO, CA
Trade endorsementsCoastwise, unrestricted, Fishery, Registry
DocumentationValid · issued 25 August 2025 · expires 31 August 2026
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it37 - Regulatory (Subpart C or D), Gross Ton
26 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

WDN6365MMSI 366915000 · active · compulsorily equipped · granted 23 February 2023, expires 23 February 2033
WDC6120MMSI 367051690 · expired · compulsorily equipped · granted 12 June 2015, cancelled 26 July 2025 · licensed under a name not among this hull’s recorded names (not shown)
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspected as a tow unit · 2

The Coast Guard recorded this vessel and the following in the same inspection activity — normally a tug and the barges in its tow. A recreational or unclassed hull in the same activity is held and not published, so it does not appear here: these lists are a floor, not a complete manifest.

PLAYBOY TOO Commercial Fishing Vessel · MISLE 46246 · 28 August 2015 · activity 5228740GOLD RUSH Passenger (Inspected) · MISLE 47977 · 28 August 2015 · activity 5228740

Inspection history · 67

3 September 2025 Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 8133568
1 April 2025 Hull Examination · Deficiency Check · Internal Structural Exam · Administrative Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 8084367
26 March 2025 Plan Review "T" Boat · Simplified Stability Test
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 8100338
4 September 2024 Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7907494
17 November 2023 Administrative Inspection · Special Consideration
Administrative · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7884025
13 June 2023 COI Inspection · Plan Review "T" Boat
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7667332
13 June 2023 In-Service Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7721941
13 June 2023 Plan Review "T" Boat
Administrative · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7762528
2 March 2023 Hull Examination · Internal Structural Exam
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7610140
28 October 2021 Hull Examination
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 7342067
19 October 2021 Annual Inspection
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 7334863
3 September 2021 In-Service Inspection
Physical examination · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 7306643
3 December 2020 Annual Inspection
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 7107730
23 October 2019 Hull Examination
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 6842005
9 October 2019 Annual Inspection
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 6835068
2 October 2019 In-Service Inspection
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 6813425
30 October 2018 COI Inspection · In-Service Inspection · Hull Examination
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 6597186
25 June 2018 Administrative Inspection
Administrative · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 6455717
5 March 2018 Annual Inspection
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 6376894
1 March 2017 COI Inspection · DAPI Audit · Deficiency Check
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 6095493
28 September 2016 Hull Examination
Physical examination · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 6010680
18 November 2015 Annual Inspection
Physical examination · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 5765506
28 August 2015 Type not recorded
No type recorded · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 5228740
9 January 2012 Administrative Inspection
Administrative · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 4221836
22 December 2011 Annual Inspection
Physical examination · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 4213307
21 January 2011 Deficiency Check · Hull Examination
Physical examination · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 3931817
21 December 2010 Annual Inspection
Physical examination · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 3914562
20 April 2009 Simplified Stability Test · Plan Review "T" Boat
Physical examination · Sector Portland · USCG Northwest District (CGD-NW) · Activity 3377598
30 March 2009 Internal Structural Exam · Hull Examination
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 3445089
24 September 2008 Deficiency Check · COI Inspection
Physical examination · Sector Portland · USCG Northwest District (CGD-NW) · Activity 3326265
22 February 2008 Deficiency Check · Hull Examination
Physical examination · Sector Portland · USCG Northwest District (CGD-NW) · Activity 3151113
5 February 2008 Administrative Inspection
Administrative · Sector Portland · USCG Northwest District (CGD-NW) · Activity 3142201
20 June 2007 Annual Inspection
Physical examination · Sector Portland · USCG Northwest District (CGD-NW) · Activity 2966070
14 June 2006 Annual Inspection
Physical examination · Sector Portland · USCG Northwest District (CGD-NW) · Activity 2678667
10 March 2006 Hull Examination
Physical examination · Sector Portland · USCG Northwest District (CGD-NW) · Activity 2608496
22 June 2005 COI Inspection · Deficiency Check
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 2396389
21 April 2004 Hull Examination · Re-Inspection
Physical examination · Marine Safety Detachment Kenai · USCG Arctic District (CGD-A) · Activity 2051313
14 April 2003 Re-Inspection
Physical examination · Marine Safety Detachment Kenai · USCG Arctic District (CGD-A) · Activity 1790113
16 April 2002 Re-Inspection · Hull Examination
Physical examination · Marine Safety Detachment Kenai · USCG Arctic District (CGD-A) · Activity 1632891
1 May 2001 COI Inspection
Physical examination · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 1420509
11 May 2000 Hull Examination · Re-Inspection
Physical examination · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 1379090
5 May 2000 Excursion Permit
Administrative · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 818043
4 May 1999 Re-Inspection
Physical examination · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 1447967
6 May 1998 COI Inspection
Physical examination · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 790024
29 April 1997 Re-Inspection
Physical examination · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 1093900
13 June 1996 Deficiency Check
Physical examination · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 1192752
16 May 1996 Re-Inspection
Physical examination · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 1085283
22 April 1996 Hull Examination
Physical examination · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 1080629
9 May 1995 COI Inspection · MARPOL Annex V Examination
Physical examination · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 1217818
20 May 1994 Re-Inspection
Physical examination · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 1358415
26 April 1994 Excursion Permit
Administrative · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 858346
11 April 1994 Hull Examination
Physical examination · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 1423903
28 April 1993 Re-Inspection
Physical examination · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 1354314
23 September 1992 Hull Examination
Physical examination · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 1255614
16 June 1992 Type not recorded
No type recorded · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 1257149
9 June 1992 Administrative
Administrative · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 1264650
4 May 1992 COI Inspection
Physical examination · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 1265236
17 May 1991 Type not recorded
No type recorded · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 1252392
25 April 1991 Re-Inspection
Physical examination · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 1216584
14 March 1991 Hull Examination
Physical examination · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 926966
19 April 1990 Re-Inspection
Physical examination · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 1238021
9 April 1989 Hull Examination · COI Inspection
Physical examination · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 898318
10 May 1988 Re-Inspection
Physical examination · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 886874
1 May 1987 Hull Examination · Re-Inspection
Physical examination · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 1326199
8 May 1986 COI Inspection
Physical examination · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 987857
27 January 1986 Credit Drydock
Administrative · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 999788
16 May 1985 Type not recorded
No type recorded · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 981696

Deficiency record · 55

13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 3 September 2025 Resolved
Vessel with a power driven steering gear must be fitted with a rudder angle indicator at the operating station; electronic rudder angle indicator inop.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 17 September 2025
Resolved 23 September 2025
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 3 September 2025 Resolved
An adult life jacket must be provided for each person on board; 2 life jackets condemned. Replaced prior to CG departure from vessel.
Action required: 10 - Deficiency Rectified
Due 3 September 2025
Resolved 3 September 2025
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 1 April 2025 Resolved
A vessel that is exposed to salt water more than three months in any 12 month period since the last examination must undergo a drydock examination and an internal structural at least once every two years. Vessel is overdue for drydock examination due March 31st, 2025. Vessel is to complete a satisfactory drydock examination prior to carrying passengers. 46 CFR 176.600 (c) (1)
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 22 April 2025
Resolution: Recieved credit dry dock
Deck/Cargo › Mooring/Anchoring › Winch
Issued 21 December 2010 Resolved
Install anchor windlass IAW 46CFR 184.300
Action required: 705 - Other - as specified
Due 5 March 2011
Resolved 9 March 2011
Resolution: Anchor windlass installed.
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 21 December 2010 Resolved
Install free in port guards IAW 46CFR 176.610
Action required: 705 - Other - as specified
Due 21 January 2011
Resolved 9 March 2011
Resolution: Freeing port guards installed.
Lifesaving › Lifejacket/PFD (Type I) › Retroreflective Material
Issued 21 December 2010 Resolved
Renew retroreflective tape on 01 lifejacket IAW 46CFR 180.78
Action required: 705 - Other - as specified
Resolved 21 January 2011
Resolution: Retro reflective tape was renewed.
Engineering › Bilge Water Management System › Pump
Issued 21 December 2010 Resolved
Prove proper operation of bilge pump IAW 46CFR 182.520.
Action required: 705 - Other - as specified
Due 21 January 2011
Resolved 21 January 2011
Resolution: Proved operation of bilge pump.
Fire Fighting › Fixed Gas Fire Extinguishing System › Operating Controls
Issued 24 September 2008 Resolved
Missing instruction placard for fixed CO2 fire extinguishing system. Owner must post instruction placard prior to 24 OCT 2008. 46 CFR 185.612(a).
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 24 September 2008
Resolved 26 September 2008
Resolution: New engraved placrd installed.
Communications › Alarms/Indicators › Fire Alarm
Issued 20 June 2007 Resolved
Install and prove operation of an USCG approved electrically supervised engine compartment heat detection system, to the satisfaction of the attending USCG Marine Inspector.
Due 20 June 2008
Resolved 22 February 2008
Resolution: Requirement was cleared at an earlier inspection and was based on NTSB recommendation.
Fire Fighting › Fixed Fire Detection System › Heat Detectors
Issued 22 June 2005 Resolved
Prove proper operations of the heat detection system in the engine space. 46 CFR 181.410 Prior to carriage of passengers.
Due 22 June 2005
Resolved 23 June 2005
Resolution: Received fax statement from Master attesting to the proper operation of the heat detection system.
Engineering › Freshwater System (jacketwater cooling) › Hose
Issued 22 June 2005 Resolved
Renew starboard engine cooling water flexible hose. 46 CFR 182.720
Due 22 July 2005
Resolved 23 June 2005
Resolution: Received fax statement from Master attesting to the renewal of the flexible hose.
Lifesaving › Lifejacket/PFD (Type I) › Condition
Issued 16 April 2002 Resolved
Replace one adult size PFD.
Due 16 April 2002
Resolved 16 April 2002
Lifesaving › Lifejacket/PFD (Type I) › Condition
Issued 1 May 2001 Resolved
Conduct U/W drills and test of propulsion machinery in presnce of Mirine Inspector.
Condition: Unknown
Due 27 May 2001
Resolved 22 June 2005
Navigation
Issued 6 May 1998 Resolved
PROVIDE AND PROOF PROPER OPERATION OF HORN.
Condition: Unknown
Due 8 May 1998
Resolved 7 May 1998
Lifesaving
Issued 6 May 1998 Resolved
MARK VESSEL NAME AND CAPACITY ON LIFEFLOAT IN AT LEAST 1 1/2 INCH LETTERS.
Condition: Unknown
Due 8 May 1998
Resolved 7 May 1998
Accommodation/Occupational Safety
Issued 6 May 1998 Resolved
MARK FORWARD ESCAPE HATCH IN AT LEAST 2 INCH LETTERS ON BOTH SIDES "EMERGENCY ESCAPE, KEEP CLEAR".
Condition: Unknown
Due 8 May 1998
Resolved 7 May 1998
Lifesaving
Issued 6 May 1998 Resolved
PROVE PROPER OPERATION OF RING BUOY WATERLIGHT.
Condition: Unknown
Due 8 May 1998
Resolved 7 May 1998
Lifesaving
Issued 6 May 1998 Resolved
PROVIDE 1 ADDITIONAL ADULT PFD. VESSEL LIMITED TO 29 PERSONS TOTAL UNTIL CLEARED.
Condition: Unknown
Due 8 May 1998
Resolved 7 May 1998
Lifesaving
Issued 6 May 1998 Resolved
REPLACE RETRO-REFLECTIVE TAPE ON 3 ADULT PFD'S.
Condition: Unknown
Due 8 May 1998
Resolved 7 May 1998
Navigation
Issued 29 April 1997 Resolved
PROVIDE EMERGENCY BROADCAST PLACARD.
Condition: Unknown
Due 30 April 1997
Resolved 8 May 1997
Lifesaving
Issued 29 April 1997 Resolved
PROVIDE LIFE JACKET DONNING PLACARD.
Condition: Unknown
Due 30 April 1997
Resolved 8 May 1997
Documentation
Issued 29 April 1997 Resolved
PROVIDE WASTE MANAGEMENT PLAN ONBOARD.
Condition: Unknown
Due 7 May 1997
Resolved 8 May 1997
Engineering
Issued 29 April 1997 Resolved
PROVE PROPER OPERATION OF BOTH MAIN DIESEL ENGINES.
Condition: Unknown
Due 6 May 1997
Resolved 8 May 1997
Fire Fighting
Issued 29 April 1997 Resolved
PROVIDE ONE ADDITIONAL BII PORTABLE FIRE EXTINGUISHER.
Condition: Unknown
Due 7 May 1997
Resolved 8 May 1997
Construction/Loadline
Issued 29 April 1997 Resolved
REMOVE WATER FROM PORT AND STARBOARD SIDES OF CENTER HOLD.
Condition: Unknown
Due 30 April 1997
Resolved 8 May 1997
Accommodation/Occupational Safety
Issued 29 April 1997 Resolved
LABEL EMERGENCY EXIT HATCH.
Condition: Unknown
Due 6 May 1997
Resolved 8 May 1997
Lifesaving
Issued 29 April 1997 Resolved
PROVIDE COVERED METAL TRASH CONTAINER IN LOUNGE.
Condition: Unknown
Due 6 May 1997
Resolved 8 May 1997
Lifesaving
Issued 29 April 1997 Resolved
PROVIDE RECORD OF DRILLS AND TRAINING.
Condition: Unknown
Due 30 April 1997
Resolved 8 May 1997
Deck/Cargo
Issued 29 April 1997 Resolved
PROVE PROPER OPERATION OF ANCHOR WINCH.
Condition: Unknown
Due 6 May 1997
Resolved 8 May 1997
Electrical
Issued 29 April 1997 Resolved
PROVE PROPER OPERATION OF GENERATOR.
Condition: Unknown
Due 6 May 1997
Resolved 8 May 1997
Electrical
Issued 29 April 1997 Resolved
REMOVE EXPOSED WIRES FROM STARBOARD SIDE FORWARD IN CENTER HOLD.
Condition: Unknown
Due 30 April 1997
Resolved 8 May 1997
Documentation
Issued 29 April 1997 Resolved
MOUNT CERTIFICATE OF INSPECTION, FCC LICENSE, RADIOTELEPHONY CERTIFICATE AND MASTERS LICENSE ON VESSEL.
Condition: Unknown
Due 6 May 1997
Resolved 8 May 1997
Lifesaving
Issued 29 April 1997 Resolved
PROVIDE RECORD OF MONTHLY EPIRB TESTING.
Condition: Unknown
Due 30 April 1997
Resolved 8 May 1997
Lifesaving
Issued 29 April 1997 Resolved
REPLACE CRACKED AND ROTTEN PADDLES FOR LIFE FLOAT.
Condition: Unknown
Due 30 April 1997
Resolved 8 May 1997
Construction/Loadline
Issued 29 April 1997 Resolved
PROVE PROPER OPERATION OF FIXED ENGINE DRIVEN BILGE PUMP.
Condition: Unknown
Due 6 May 1997
Resolved 8 May 1997
Lifesaving
Issued 16 May 1996 Resolved
SECURE PAINTER TO LIFEFLOAT.
Condition: Unknown
Due 16 May 1996
Resolved 21 May 1996
Lifesaving
Issued 16 May 1996 Resolved
REPLACE SPLIT PADDLES IN LIFEFLOAT.
Condition: Unknown
Due 16 May 1996
Resolved 16 May 1996
Construction/Loadline
Issued 16 May 1996 Resolved
SECURE WATERTIGHT HATCH FOR LAZARETTE TO VESSEL.
Condition: Unknown
Due 16 May 1996
Resolved 21 May 1996
Lifesaving
Issued 16 May 1996 Resolved
REPAIR NUMEROUS TEARS AND SPLITS ON LIFEFLOAT WITH MANUFACTURERS APPROVED PATCH.
Condition: Unknown
Due 16 May 1996
Resolved 16 May 1996
Lifesaving
Issued 16 May 1996 Resolved
SECURE LINE FROM WATERLIGHT TO LIFEFLOAT.
Condition: Unknown
Due 16 May 1996
Resolved 21 May 1996
Electrical
Issued 16 May 1996 Resolved
REMOVE EXPOSED DEAD END WIRING ABOVE AND AFT OF STARBOARD MAIN ENGINE.
Condition: Unknown
Due 16 May 1996
Resolved 21 May 1996
Construction/Loadline
Issued 22 April 1996 Resolved
REPLACE CLAMPS (SUPPORTS) FOR FISH HOLD DRAIN PIPING IN LAZARETTE.
Condition: Unknown
Due 22 April 1996
Resolved 22 April 1996
Navigation
Issued 9 May 1995 Resolved
INSTALL DOUBLE NUT/COTTER/KEY TO STEERING LINKAGE.
Condition: Unknown
Due 9 May 1995
Resolved 9 May 1995
Navigation
Issued 9 May 1995 Resolved
REPAIR SSB RADIO FREQUENCY PAD AND PROVE SATISACTORY OPERATION.
Condition: Unknown
Due 9 May 1995
Resolved 9 May 1995
Accommodation/Occupational Safety
Issued 9 May 1995 Resolved
REWIRE MASERATOR PUMP TO MSD.
Condition: Unknown
Due 9 May 1995
Resolved 9 May 1995
Lifesaving
Issued 9 May 1995 Resolved
INSTALL PENDANTS TO LIFEFLOATS.
Condition: Unknown
Due 9 May 1995
Resolved 9 May 1995
Electrical
Issued 9 May 1995 Resolved
MAKE PERMANENT REPAIRS TO GEN SET TO PREVENT WATER LEAK FROM IMPELLER.
Condition: Unknown
Due 9 May 1995
Resolved 9 May 1995
Engineering
Issued 4 May 1992 Resolved
LABEL EMERGENCY FUEL SHUT-OFF VALVES.
Condition: Unknown
Due 4 May 1992
Resolved 4 May 1992
Documentation
Issued 4 May 1992 Resolved
PROVIDE CURRENT STABLILITY LETTER.
Condition: Unknown
Due 4 May 1992
Resolved 4 May 1992
Deck/Cargo
Issued 4 May 1992 Resolved
MAKE PERMANENT REPAIRS TO ANCHOR WINCH AND PROVE PROPER OPERATION.
Condition: Unknown
Due 4 May 1992
Resolved 4 May 1992
Construction/Loadline
Issued 14 March 1991 Resolved
Provide and install strainers and check valves on all bilge suction lines.
Condition: Unknown
Due 14 March 1991
Resolved 14 March 1991
Construction/Loadline
Issued 14 March 1991 Resolved
Make available for inspection the forward compartment.
Condition: Unknown
Due 14 March 1991
Resolved 14 March 1991
Construction/Loadline
Issued 14 March 1991 Resolved
Cover the hole in the forward bulkhead of the storeroom, below decks on thevessels starboard side.
Condition: Unknown
Due 14 March 1991
Resolved 14 March 1991
Construction/Loadline
Issued 14 March 1991 Resolved
Repair the fractures on both the port and starboard sides of the vessel at the forward step.
Condition: Unknown
Due 14 March 1991
Resolved 14 March 1991
Engineering
Issued 14 March 1991 Resolved
Design and install guards for the main engine pullys on the forward ends ofboth main engines and on the port main engine main shaft.
Condition: Unknown
Due 14 March 1991
Resolved 14 March 1991

Ownership record