Records from 2016 to 2026. Most recent: inspection, 6 May 2026.
07 - Fire Safety › N/A - No Subsystem › Division - decks, bulkheads and penetrations
Issued 10 December 2025
Resolved
The following fire protection systems and appliances shall be kept in good working order so as to ensure their required performance if a fire occurs: structural fire protection, including fire-resisting divisions, and protection of openings and penetration in these divisions. Engineroom fire dampers SS-134, and SS-136 do not fully close, engineroom fire damper SS-138 indicates a motor failed alarm on the MCCS panel and its operation was not able to be witnessed, and fire damper 4-86-2 for cargo hold 5C is unwired.
74SOLAS(24)2/14.2.1.1.1
Action required: 60 - Rectify deficiencies prior to movement
Resolved 12 January 2026
Resolution: Received ABS report.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 10 December 2025
Resolved
In a ship in which oil fuel is used, the arrangements for the storage, distribution and utilization of the oil fuel shall be such as to ensure the safety of the ship and persons on board. The EDG fuel tank sight glasses are leaking fuel oil and the EDG fuel oil return pipe union in the overhead is leaking fuel oil.
74SOLAS(01)II-2/15.2
Action required: 50 - Rectify deficiencies w/in 30 days
Due 9 January 2026
Resolved 12 January 2026
Resolution: Received ABS Report.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 10 December 2025
Resolved
Fire-fighting systems and appliances shall be kept in good working order and readily available for immediate use. Found the CO2 alarm panel outside of the bow thruster space missing the power available light bulb.
74SOLAS(24)II-2/14.2.1.2
Action required: 50 - Rectify deficiencies w/in 30 days
Due 9 January 2026
Resolved 12 January 2026
Resolution: Received ABS Report.
09 - Working and Living Conditions › 092 - Working Conditions › Lighting (Working spaces)
Issued 10 December 2025
Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure the ship in all respects will remain fit to proceed to sea without danger to the ship or persons on board. Found numerous lights not working, missing bulbs, missing covers, etc. in the following spaces – bow thruster space, steering gear space, aft mooring/towing space.
74SOLAS(24)I/11(a)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 9 January 2026
Resolved 12 January 2026
Resolution: Received ABS Report.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 10 December 2025
Resolved
Portable fire extinguishers and their stations must be numbered in accordance with 46CFR97.37-23 of this subchapter. Found portable extinguishers not numbered as required by the U.S. Supplement to International Conventions and Class Society Rules Nov 2025 at various locations in the following spaces – stbd side aft mooring/towing space, engineroom, and stbd engine room upper stack/casing.
46CFR95.50(e) and U.S.Supplement NOV. 2025, 2.4.2.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 9 January 2026
Resolved 12 January 2026
Resolution: Received ABS Report.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 10 December 2025
Resolved
The following fire protection shall be kept in good working order so as to ensure their required performance if a fire occurs: .2 fire detection and fire alarm systems. The trouble alarm on the vessel’s fire alarm panel could not clear. Alarms will still sound when tested.
74SOLAS(24) II-2/14 2.1.1.2
Action required: 50 - Rectify deficiencies w/in 30 days
Due 9 January 2026
Resolved 12 January 2026
Resolution: Received ABS Report.
08 - Alarms › N/A - No Subsystem › Steering gear alarm
Issued 10 December 2025
Resolved
Main and auxiliary steering power units must, in event of a power failure to any of the steering power units, an audible and visual alarm given on the navigation bridge. Steering unit loss of power and low hydraulic oil level alarms did not annunciate (audible) on the bridge.
74SOLAS(04)II-1/29 5.2
Action required: 50 - Rectify deficiencies w/in 30 days
Due 9 January 2026
Resolved 12 January 2026
Resolution: Received ABS Report.
08 - Alarms › N/A - No Subsystem › Machinery controls alarm
Issued 10 December 2025
Resolved
Automation systems shall be designed in a manner which ensures that the threshold warning of impending or imminent slowdown or shutdown of the propulsion system is given to the officer in charge of the navigational watch. Each alarm indicator in the Starboard Vital Alarm Panel for the 1A and 1B engines is mislabeled as 2A and 2B and lights up as 2A or 2B when activated. P-touch labeling on the console, above the alarm panel, is not acceptable as a permanent fix.
74SOLAS(04)II-1/31.2.10
Action required: 50 - Rectify deficiencies w/in 30 days
Due 9 January 2026
Resolved 12 January 2026
Resolution: Received ABS Report.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 10 December 2025
Resolved
All waste receptacles shall be constructed of non-combustible materials with no openings in the sides and bottoms. Trash cans, located in the galley and mess rooms are constructed of plastic material.
74SOLAS(01)II-2/18.5
Action required: 50 - Rectify deficiencies w/in 30 days
Due 9 January 2026
Resolved 12 January 2026
Resolution: Received ABS Report.
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance and inspections
Issued 10 December 2025
Resolved
Maintenance, testing and inspections of lifesaving appliances shall be carried out in a manner having due regards to ensuring reliability of such appliances. #4 LB has a longitudinal crack in the fiberglass hull, 8 inches below the right-side hatch opening, when viewed from inside. Showing signs of water intrusion into the inside of the LB.
705 Other = Total person count reduced to 50 persons total until crack is evaluated/ corrected by OEM representative.
74SOLAS(24)III/20.3
Action required: 705 - Other - as specified
Resolved 12 January 2026
Resolution: Received ABS Report.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Doors
Issued 12 February 2025
Resolved
Each power-operated sliding watertight door shall be provided with an individual hand-operated mechanism. It shall be possible to open and close the door by hand at the door itself from both sides. WTD 5-99-2 is not able to be opened by hand from the fully closed position.
74SOLAS(04)II-1/25-9.2
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 February 2025
Resolved 20 February 2025
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 12 February 2025
Resolved
Electrical installations shall be such that the safety of passengers, crew and ship from electrical hazards will be ensured. There is a soft patch repair on electrical cable near WTD 5-99-2.
74SOLAS(04)II-1/40.1.3
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 February 2025
Resolved 20 February 2025
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 12 February 2025
Resolved
Electrical installations shall be such that the safety of passengers, crew and ship from electrical hazards will be ensured. There is a ground on the 480 bus, likely from cargo hold light 3C.
74SOLAS(04)II-1/40.1.3
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 February 2025
Resolved 20 February 2025
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 12 February 2025
Resolved
The following fire protection systems shall be kept in good order so as to ensure their required performance if a fire occurs: structural fire protection, including fire-resisting divisions, and protection of openings and penetrations in these divisions. Self-closing fire door 5-90-2 did not latch when released.
74SOLAS(20)II-2/14.2.1.1.1
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 February 2025
Resolved 20 February 2025
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 12 February 2025
Resolved
In a ship in which oil fuel is used, the arrangements for the storage, distribution and utilization of the oil fuel shall be such as to ensure the safety of the ship and persons on board. The arrangements for the storage, distribution and utilization of oil used in pressure lubrication systems shall be such as to ensure the safety of the ship and persons on board. On the #1A MDE, the fire sleeves on one lube oil and two fuel oil return lines were chafed through.
74SOLAS(01)II-2/15.2, 15.3
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 February 2025
Resolved 20 February 2025
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 12 February 2025
Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure that the ship in all respects will remain safe to proceed to sea without danger to the ship or persons on board. There is significant accumulation of oil in the bilge forward of the MDEs.
74SOLAS(20)I/11(a)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 February 2025
Resolved 20 February 2025
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 12 February 2025
Resolved
Electrical installations shall be such that the safety of passengers, crew and ship from electrical hazards will be ensured. An open electrical box with dead end wires was found on the back deck IWO the life rafts.
74SOLAS(04)II-1/40.1.3
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 February 2025
Resolved 20 February 2025
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 12 February 2025
Resolved
Electrical installations shall be such that the safety of passengers, crew and ship from electrical hazards
will be ensured. Multiple lights were found throughout
the cargo decks without covers.
74SOLAS(04)II-1/40.1.3
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 February 2025
Resolved 20 February 2025
11 - Life Saving Appliances › N/A - No Subsystem › On board training and instructions
Issued 12 February 2025
Resolved
Posters or signs shall be provided on or in the vicinity of survival craft and shall illustrate the procedures for operating the appliance. Instructions for life rafts
were not readily posted.
74SOLAS(20)III/9.2.1
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 February 2025
Resolved 20 February 2025
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 12 February 2025
Resolved
Fire-fighting systems and appliances shall be kept in good working order and readily available for immediate use. Multiple fire extinguishers throughout the cargo decks were not secured properly.
74SOLAS(20)II-2/14.2.1.2
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 February 2025
Resolved 20 February 2025
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 12 February 2025
Resolved
Fire-fighting systems and appliances shall be kept in good working order and readily available for immediate use. Foam sprinkler head on F-Deck was found to be clogged.
74SOLAS(20)II-2/14.2.1.2
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 February 2025
Resolved 20 February 2025
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 12 February 2025
Resolved
Fire-fighting systems and appliances shall be kept in good working order and readily available for immediate use. Heat detector on C-Deck for fire detection system was found unsecured and dangling.
74SOLAS(20)II-2/14.2.1.2
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 February 2025
Resolved 20 February 2025
09 - Working and Living Conditions › 092 - Working Conditions › Other (accident prevention)
Issued 12 February 2025
Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure that the ship in all respects will remain safe to proceed to sea without danger to the ship or persons on board. Nitrogen bottle found IWO reefer
not secured.
74SOLAS(20)I/11(a)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 February 2025
Resolved 20 February 2025
04 - Emergency Systems › N/A - No Subsystem › Abandon ship drills
Issued 12 February 2025
Resolved
Every crew member shall participate in one abandon ship drill and one fire drill every month. Vessel has not conducted a recent fire drill or abandon ship drill with full crew complement. Rectify prior to activation.
74 SOLAS (20) III/19.3.2
Action required: 705 - Other - as specified
Resolved 4 May 2026
Resolution: Completed Drills.
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 12 February 2025
Resolved
Nautical charts and publications shall be adequate and up to date. Vessel charts are not reflective of most current updates. Rectify prior to activation.
74 SOLAS (20) V/27
33 CFR 164.33
Action required: 705 - Other - as specified
Resolved 4 May 2026
Resolution: Confrimed charts and pubs up to date.
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 12 February 2025
Resolved
All lifesaving appliances shall be ready for immediate use.
Lifesaving appliances and equipment are stowed off station.
Rectify prior to activation.
74 SOLAS (20) III/20.2
Action required: 705 - Other - as specified
Resolved 4 May 2026
Resolution: Confirmed life saving equipment on stations.
01 - Certificates & Documentation › 012 - Crew Certificates › Manning specified by the minimum safe manning doc
Issued 12 February 2025
Resolved
The certificate of inspection (COI) issued by an OCMI specifies the minimum complement necessary for the safe operation of the vessel. Vessel was not fully manned in accordance with COI. Rectify prior to activation.
46 CFR 15.501
Action required: 705 - Other - as specified
Resolved 4 May 2026
Resolution: Verified manning and credentials on board.
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 7 February 2025
Resolved
Your vessel must undergo an annual inspection within the 3 months before or after each anniversary date.
The term anniversary date means the day and the month of each year, which corresponds to the date of expiration of the Certificate of Inspection.
Vessel is overdue for ACP Annual Oversight Exam.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 12 February 2025
Resolution: Completed annual inspection
01 - Certificates & Documentation › 011 - Ships Certificates › Cargo Ship Safety Radio (including exemption)
Issued 14 February 2024
Resolved
Stations in the maritime service must be licensed by the FCC either individually or by fleet. No proof on board thata station license has been issued by the FCC. 47 CFR 80.12
Action required: 50 - Rectify deficiencies w/in 30 days
Due 16 March 2024
Resolved 23 February 2024
Resolution: ABS has taken this for action.
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 14 February 2024
Resolved
Doors required to be self closing shall not be fitted with hold-back hooks. Several self closing doors were found to be held open with rope in the Ro-Ro spaces and the machinery spaces. 74 SOLAS (20 Cons) II-2/9.4.2.2
Action required: 50 - Rectify deficiencies w/in 30 days
Due 16 March 2024
Resolved 23 February 2024
04 - Emergency Systems › N/A - No Subsystem › Abandon ship drills
Issued 13 April 2023
Resolved
Every crew member shall participate in at least one abandon ship drill and one fire drill every month. Conduct fire and abandon ship drills, to include lowering a lifeboat, in the presence of the attending Coast Guard Marine Inspector prior to activation.
74SOLAS(20)III/19.3.2
Action required: 705 - Other - as specified
Resolved 19 May 2023
Resolution: Witnessed satisfactory fire and abandon ship drills. Crew donned life jackets and brought immersion suits and required gear.
01 - Certificates & Documentation › 012 - Crew Certificates › Manning specified by the minimum safe manning doc
Issued 13 April 2023
Resolved
Upon activation, vessel is to provide MMCs for all crew members when vessel is fully crewed in accordance with the COI manning to the satisfaction of the attending Coast Guard Marine Inspector.
46 CFR 15.401
Action required: 705 - Other - as specified
Resolved 18 May 2023
Resolution: Verified valid MMCs, TWICs, and Medical Certificates to include minumum GMDSS and Lifeboatman training to COI minimum safe manning; all sat.
10 - Safety of Navigation › N/A - No Subsystem › Nautical publications
Issued 13 April 2023
Resolved
All ships shall have nautical charts and nautical publications to plan and display the ship's route for the intended voyage. Vessel does not have currently corrected charts or up to date nautical publications. Provide updated nautical publications prior to activation.
74SOLAS(20) V/ 19.2.1.4
Action required: 705 - Other - as specified
Resolved 18 May 2023
Resolution: Verified updated and corrected charts and publications for planned voyage, all sat.
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 13 April 2023
Resolved
After any survey, no change shall be made in the structural arrangements, machinery, equipment, and other items covered by the survey, without the sanction of the Administration. Found numerous emergency lighting throughout the vessel was inoperable.
74SOLAS(20) I/11(b)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 April 2023
Resolved 19 April 2023
07 - Fire Safety › N/A - No Subsystem › Fire-dampers
Issued 13 April 2023
Resolved
The following fire protection systems shall be kept in good working order so as to ensure their required performance if a fire occurs: structural fire protection, including fire-resisting divisions, and protection of openings and penetrations in these divisions. Ventilation fire damper SS-134 was found inoperable.
74SOLAS(20) II-2/14.2.1.1.1
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 April 2023
Resolved 19 April 2023
07 - Fire Safety › N/A - No Subsystem › Fire-dampers
Issued 13 April 2023
Resolved
The following fire protection systems shall be kept in good working order so as to ensure their required performance if a fire occurs: structural fire protection, including fire-resisting divisions, and protection of openings and penetrations in these divisions. Ventilation fire damper SS-135 and 04-90-1 failed to close completely.
74SOLAS(20) II-2/14.2.1.1.1
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 April 2023
Resolved 19 April 2023
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 13 April 2023
Resolved
Two means of escape shall be provided from each machinery space of Category A. In particular, one of the following provisions shall be complied with: Self-closing doors of the same fire integrity standards shall be fitted in the enclosure. Escape trunk 5-95-4 fire door missing closing mechanism, failed to secure in the closed position.
74SOLAS(20) II-2/13.4.2.1.1
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 April 2023
Resolved 19 April 2023
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 19 July 2022
Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or persons on board. Vessel reported rudder drifting without remote control input while operating in the follow-up mode on both port and starboard steering gear pumps.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 20 July 2022
Resolution: Recieved ABS survey after construction report.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 6 July 2022
Resolved
Vessel is required 2 tug escorts greater than 3,000HP to assist vessel to sea buoy upon departure. If the issue is not corrected during underway sea trials, vessel is required to have 2 tug escorts greater than 3,000HP escort vessel back to mooring from sea buoy.
33CFR160.111(c)
Action required: 17 - Rectify deficiencies prior to departure
Due 6 July 2022
Resolved 21 July 2022
Resolution: Vessel completed sea trials, cpp operated correctly.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 6 July 2022
Resolved
Fire-fighting systems and appliances shall be kept in good order and available for immediate use. STBD CO2 discharge alarm panel for the 04 level fidley room has in inoperable light. 74 SOLAS (20) II-2/14.2.1.2
Action required: 60 - Rectify deficiencies prior to movement
Due 6 July 2022
Resolved 15 July 2022
Resolution: Accepted as a condition of ACS.
07 - Fire Safety › N/A - No Subsystem › Fire-dampers
Issued 6 July 2022
Resolved
Fire protection systems shall be kept in good working order as to ensure their required performance if a fire occurs, including protection of openings. Engine room fire dampers 4-90-1, SS-135, SS-136, SS-139, PC-21 do not properly close. 74 SOLAS (20) II-2/14.2.1.1.1
Action required: 60 - Rectify deficiencies prior to movement
Due 6 July 2022
Resolved 15 July 2022
Resolution: Accepted as a condition of ACS.
11 - Life Saving Appliances › N/A - No Subsystem › Rescue boats
Issued 6 July 2022
Resolved
Before the ship leaves port and at all times during the voyage, all life-saving appliances shall be in working order and ready for immediate use. Rescue boat starting was intermittent, crew ordered parts and are awaiting arrival and installation.74 SOLAS (20) III/20.2
Action required: 60 - Rectify deficiencies prior to movement
Due 6 July 2022
Resolved 15 July 2022
Resolution: Accepted as a condition of ACS.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Doors
Issued 6 July 2022
Resolved
The condition of the ship and its equipment shall be maintained to ensure that the ship will remain fit to proceed to sea without danger to the ship or persons on board. The stbd side cargo door displayed a panel showed door open when it was actually closed.
74 SOLAS (20) I/11(a)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 6 August 2022
Resolved 15 July 2022
Resolution: Accepted as a condition of ACS.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 6 July 2022
Resolved
Hydraulic powered steering gear units shall in the event of a power failure or low-level give an audible and visual alarm on bridge. Vessels audible alarm did not sound on bridge due to installed toggle switch engaged on bridge. Consult installation plans to see if toggle
switch was originally installed, if not remove toggle
switch so alarms will sound without human intervention.
74 SOLAS (01) II-1/29.12.2
Action required: 50 - Rectify deficiencies w/in 30 days
Due 6 August 2022
Resolved 15 July 2022
Resolution: Accepted as a condition of ACS.
07 - Fire Safety › N/A - No Subsystem › Fire-dampers
Issued 6 July 2022
Resolved
Fire protection systems shall be kept in good working order as to ensure their required performance if a fire occurs, including protection of openings. Ventilation fire damper ES118 (2-108-2) did not fully open.74 SOLAS (20) II-2/14.2.1.1.1
Action required: 50 - Rectify deficiencies w/in 30 days
Due 6 August 2022
Resolved 15 July 2022
Resolution: Accepted as a condition of ACS.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 6 July 2022
Resolved
Fire protection systems shall be kept in good working order as to ensure their required performance if a fire occurs, including fire detection and fire alarm systems. Fire detection panel located in compartment aft of pilot house was not properly labeled.
74 SOLAS (20) II-2/14.2.1.1.1
Action required: 50 - Rectify deficiencies w/in 30 days
Due 6 August 2022
Resolved 15 July 2022
Resolution: Accepted as a condition of ACS.
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 6 July 2022
Resolved
Fire protection systems shall be kept in good working order so as to ensure their required performance if a fire occurs: structural fire protection, including fire-resisting divisions, and protection of openings and penetrations in these divisions. Fire boundary doors located at 3-87-3 and 1-83-0 did not close.
74 SOLAS (20) II-2/14.2.1.1.1
Action required: 50 - Rectify deficiencies w/in 30 days
Due 6 August 2022
Resolved 15 July 2022
Resolution: Accepted as a condition of ACS.
09 - Working and Living Conditions › 092 - Working Conditions › Obstruction/slipping, etc.
Issued 6 July 2022
Resolved
The condition of the ship and its equipment shall be maintained to conform with the regulations to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or persons on board. Aft steering has excessive hydraulic oil on the deck.
74 SOLAS (20) I/11(a)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 6 August 2022
Resolved 15 July 2022
Resolution: Accepted as a condition of ACS.
09 - Working and Living Conditions › 092 - Working Conditions › Obstruction/slipping, etc.
Issued 6 July 2022
Resolved
The condition of the ship and its equipment shall be maintained to conform with the regulations to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or persons on board. AC flat has excessive oil and water on the deck.
74 SOLAS (20) I/11(a)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 6 August 2022
Resolved 15 July 2022
Resolution: Accepted as a condition of ACS.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 6 July 2022
Resolved
The condition of the ship and its equipment shall be maintained to conform with the regulations to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or persons on board. #1 auxiliary boiler flame out sensor was zip tied in place.
74 SOLAS (20) I/11(a)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 6 August 2022
Resolved 15 July 2022
Resolution: Accepted as a condition of ACS.
07 - Fire Safety › N/A - No Subsystem › Division - decks, bulkheads and penetrations
Issued 6 July 2022
Resolved
The condition of the ship and its equipment shall be maintained to ensure that the ship will remain fit to proceed to sea without danger to the ship or persons on board. Spray foam was found being used as fire block in the MCT in the fan room located on A deck (1-83-0).
74 SOLAS (20) I/11(a)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 6 August 2022
Resolved 15 July 2022
Resolution: Accepted as a condition of ACS.
07 - Fire Safety › N/A - No Subsystem › Division - decks, bulkheads and penetrations
Issued 6 July 2022
Resolved
The following fire protection systems shall be kept in good working order so as to ensure their required performance if a fire occurs: structural fire protection, including fire-resisting divisions, and protection of openings and penetrations in these divisions. Bridge deck had multiple holes breaching A-60 fire boundary IWO fire block and bulkhead. 74 SOLAS (20) II-2/14.2.1.1.1
Action required: 50 - Rectify deficiencies w/in 30 days
Due 6 August 2022
Resolved 15 July 2022
Resolution: Accepted as a condition of ACS.
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 6 July 2022
Resolved
Fire protection systems shall be kept in good working order as to ensure their required performance if a fire occurs,including protection of openings. Stair tower fire door 5-92-1 is not self closing.
74 SOLAS (20) II-2/14.2.1.1.1
Action required: 50 - Rectify deficiencies w/in 30 days
Due 6 August 2022
Resolved 15 July 2022
Resolution: Accepted as a condition of ACS.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 14 December 2021
Resolved
The following fire protection systems shall be kept in good order so as to ensure their required performance if a fire occurs :fire detection and fire alarm systems. Fire control panel is displaying a “Fatal Trouble” alarm. 74 SOLAS (20) II-2/14.2.1.1.2
Action required: 17 - Rectify deficiencies prior to departure
Resolved 21 December 2021
Resolution: Witnes by ABS and Coast Guard
08 - Alarms › N/A - No Subsystem › Machinery controls alarm
Issued 14 December 2021
Resolved
Main and auxiliary steering gear power unit shall: In the event of a power failure to any one of the steering gear power units, an audible and visual alarm shall be given on the navigational bridge. The audible alarm did not annunciate. 74 SOLAS (01) II-1/29.5.2
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 21 December 2021
Resolution: Witnessed by ABS and Coast Guard
08 - Alarms › N/A - No Subsystem › Machinery controls alarm
Issued 14 December 2021
Resolved
Hydraulic powered-operated steering gear shall be provided with the following: a low-level alarm for each hydraulic fluid reservoir. Audible and visual alarms shall be given on the navigational bridge. The audible alarm did not annunciate. 74 SOLAS (01) II-1/29.12.2
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 21 December 2021
Resolution: Witnessed by ABS and Coast Guard
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 14 December 2021
Resolved
Fire control panels are required to be type approved by the CG. This functions is not delegated to the RO or Class Society under ACP procedures. Provide CG approval certificate for the newly installed fire control panels. 46 CFR 2.75, ACP CG TTP 3-72.9A 2019, NVIC 2-95 Ch. 3 Enclosure 1 (pg.4)
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 21 December 2021
Resolution: Approval certificate provided.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Doors
Issued 14 December 2021
Resolved
The condition of the ship and its equipment shall be maintained to ensure that the ship will remain fit to proceed to sea without danger to the ship or persons aboard. The engineer workshop’s Class 3 watertight door’s bulkhead deck pump handle moves in the open direction when the watertight door is closed locally with power, and the local pump handle is leaking hydraulic fluid at the seal. 74 SOLAS (20) I/11(a)
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 16 February 2022
14 - Pollution Prevention › 141 - MARPOL Annex I › Oil filtering equipment
Issued 14 December 2021
Resolved
Every ship of 400 gross tons and above shall be subject to an annual survey of the equipment and arrangements to ensure they have been maintained and that they remain satisfactory for the service intended. Crew was not able to demonstrate operation of the oily water separator and function test of oil content meter to the satisfaction of the attending CG marine inspector. MARPOL (17) Annex I/6.1.4
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 1 February 2022
Resolution: Witnessed Chief Engineer conduct satisfactory operational tests of the OWS, and function test of OCM IAW manufactures test procedures. Witnessed both test twice.
07 - Fire Safety › N/A - No Subsystem › Fire-dampers
Issued 14 December 2021
Resolved
The condition of the ship and its equipment shall be maintained to ensure that the ship will remain fit to proceed to sea without danger to the ship or persons aboard. Engine compartment supply ventilation fire damper SS-137 did not close during testing. 74 SOLAS (20) I/11(a)
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 16 February 2022
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 14 December 2021
Resolved
Fire-fighting systems and appliances shall be kept in good working order and readily available for immediate use. Steering flat fire station No. 69 has a leaking wye gate. 74 SOLAS (20) II-2/14.2.1.2
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 16 February 2022
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 14 December 2021
Resolved
Escape systems and appliances shall be kept in good order so as to ensure their required performance if a fire occurs. The emergency escape scuttle in way of the bow thruster compartment has erratic operation and the hinges will not lock in the open position. 74 SOLAS (20) II-2/14.2.1.1.3
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 16 February 2022
03 - Water/Weathertight Conditions › N/A - No Subsystem › Doors
Issued 14 December 2021
Resolved
Doorways in deckhouses that lead or give access to stairways leading below shall be fitted with doors that when secured closed makes the door weathertight. The QAWTD 1-112-1 at the weather deck appears warped a not weathertight. ICLL (88 Proto) 18(2)
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 16 February 2022
09 - Working and Living Conditions › 092 - Working Conditions › Machinery
Issued 14 December 2021
Resolved
The condition of the ship and its equipment shall be maintained to ensure that the ship will remain fit to proceed to sea without danger to the ship or persons aboard. The fuel oil line for auxiliary boiler No.2 has rags and heat cord wrapped around its entire length. 74 SOLAS (20) I/11(a)
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 16 February 2022
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 14 December 2021
Resolved
The condition of the ship and its equipment shall be maintained to ensure that the ship will remain fit to proceed to sea without danger to the ship or persons aboard. Emergency light at the EDG switchboard is inoperative. 74 SOLAS (20) I/11(a)
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 16 February 2022
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 14 December 2021
Resolved
Fire-fighting systems and appliances shall be kept in good working order and readily available for immediate use. A smoke detector above the EDG switchboard has a metal shroud affixed around it. 74 SOLAS (20) II-2/14.2.1.2
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 16 February 2022
04 - Emergency Systems › N/A - No Subsystem › Emergency source of power - Emergency generator
Issued 14 December 2021
Resolved
After any survey of the ship has been completed, no changes shall be made in the structural arrangements, machinery, equipment and other items covered by the survey, without the sanction of the Administration. The jacket water motor controller has a wired temperature probe running from the controller enclosure and taped to a nearby flexible hose. 74 SOLAS (20) I/11(b)
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 16 February 2022
04 - Emergency Systems › N/A - No Subsystem › Emergency steering position com./ compass reading
Issued 14 December 2021
Resolved
The condition of the ship and its equipment shall be maintained to ensure that the ship will remain fit to proceed to sea without danger to the ship or persons aboard. The steering flat’s sound powered phone has mislabeled call stations. 74 SOLAS (20) I/11(a)
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 16 February 2022
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 14 December 2021
Resolved
After any survey of the ship has been completed, no changes shall be made in the structural arrangements, machinery, equipment and other items covered by the survey, without the sanction of the Administration. Power panel 16P402 (6-88-1) in the engine compartment has mislabeled circuit breakers. 74 SOLAS (20) I/11(b)
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 16 February 2022
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 14 December 2021
Resolved
Fire-fighting systems and appliances shall be kept in good working order and readily available for immediate use. Multiple portable extinguishers in the accommodation spaces were not mounted correctly, missing mount locking pins, and one extinguisher mount iwo hospital space was found broken off the passageway bulkhead. 74 SOLAS (20) II-2/14.2.1.2
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 16 February 2022
03 - Water/Weathertight Conditions › N/A - No Subsystem › Ventilators, air pipes, casings
Issued 14 December 2021
Resolved
The condition of the ship and its equipment shall be maintained to ensure that the ship will remain fit to proceed to sea without danger to the ship or persons aboard. The vent closure for Discharge 1-18-2,IWO port bow partially missing gasket, frozen in open position. 74 SOLAS (20) I/11(a)
Action required: 10 - Deficiency Rectified
Resolved 21 December 2021
03 - Water/Weathertight Conditions › N/A - No Subsystem › Ventilators, air pipes, casings
Issued 14 December 2021
Resolved
The condition of the ship and its equipment shall be maintained to ensure that the ship will remain fit to proceed to sea without danger to the ship or persons aboard. The vent closure for Discharge 2-18-1, IWO STBD bow frozen in open position. 74 SOLAS (20) I/11(a)
Action required: 10 - Deficiency Rectified
Resolved 21 December 2021
03 - Water/Weathertight Conditions › N/A - No Subsystem › Ventilators, air pipes, casings
Issued 14 December 2021
Resolved
The condition of the ship and its equipment shall be maintained to ensure that the ship will remain fit to proceed to sea without danger to the ship or persons aboard. The vent closure for Discharge 2-16-2, IWO Port bow, frozen in open position. 74 SOLAS (20) I/11(a)
Action required: 10 - Deficiency Rectified
Resolved 21 December 2021
03 - Water/Weathertight Conditions › N/A - No Subsystem › Ventilators, air pipes, casings
Issued 14 December 2021
Resolved
The condition of the ship and its equipment shall be maintained to ensure that the ship will remain fit to proceed to sea without danger to the ship or persons aboard. The vent closure for Discharge 2-17-1, IWO STBD bow frozen in open position. 74 SOLAS (20) I/11(a)
Action required: 10 - Deficiency Rectified
Resolved 21 December 2021
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 14 December 2021
Resolved
Fire-fighting systems and appliances shall be kept in good working order and readily available for immediate use. Galley deep fat fryer fixed firefighting system's agent bottle was disconnected. 74 SOLAS (20) II-2/14.2.1.2
Action required: 10 - Deficiency Rectified
Resolved 21 December 2021
11 - Life Saving Appliances › N/A - No Subsystem › Radio life-saving appliances
Issued 12 April 2021
Resolved
All life saving appliances shall be in working order and ready for immediate use. Vessel was missing one sealed lifeboat radio battery.
74SOLAS(14)III/20.2
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 April 2021
Resolved 19 April 2021
07 - Fire Safety › N/A - No Subsystem › Fire-dampers
Issued 12 April 2021
Resolved
The condition of the ship and its equipment shall conform with the regulations to proceed to sea without danger. Dampers 5-110-2 and 7-45-2 did not close properly.
74SOLAS(14)I/11(a)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 April 2021
Resolved 19 April 2021
10 - Safety of Navigation › N/A - No Subsystem › Voyage data recorder (VDR)/Simplified Voyage data recorder(S-VDR)
Issued 12 April 2021
Resolved
The condition of the ship and its equipment shall conform with the regulations to proceed to sea without danger. VDR starboard microphone was inoperable.
74SOLAS(14)I/11(a)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 April 2021
Resolved 19 April 2021
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 12 April 2021
Resolved
The condition of the ship's equipment must conform with the present regulations. The fire detection panel was displaying a trouble alarm.
74SOLAS(14)I/11(a)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 April 2021
Resolved 19 April 2021
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 12 April 2021
Resolved
Not less than 2 lifebuoys should be provided with lifebuoy self-activating smoke signals capable of quick release from the navigation bridge. The lines attached to the smoke signals were too short. Correct on the spot.
74SOLAS(14)III/7.1.3
Action required: 10 - Deficiency Rectified
Resolved 13 April 2021
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 12 April 2021
Resolved
Distress flares shall be carried and stowed on or near the navigation bridge. Distress flares were being stowed with expired flares. Corrected on the spot.
74SOLAS(14)III/6.3
Action required: 10 - Deficiency Rectified
Resolved 13 April 2021
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 12 April 2021
Resolved
Before ship leaves the port and at all times during the voyage, all life saving appliances shall be in working order and ready for immediate use. Water for all 4 lifeboats was being stored in the house. Corrected on the spot.
74SOLAS(14)III/20.2
Action required: 10 - Deficiency Rectified
Resolved 13 April 2021
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 12 April 2021
Resolved
Fire protection systems and fire-fighting systems and appliances shall be properly tested and inspected. Fire door in stair tower below navigation bridge was not properly closing. Corrected on the spot.
74SOLAS(14)II-2/14.1.1
Action required: 10 - Deficiency Rectified
Resolved 13 April 2021
10 - Safety of Navigation › N/A - No Subsystem › Voyage data recorder (VDR)/Simplified Voyage data recorder(S-VDR)
Issued 9 May 2019
Resolved
To assist in casualty investigations, cargo ships, when engaged on international voyages, shall be fitted with a VDR which may be an S-VDR. Vessels S-VDR is not properly recording voyage data. Repair to the satisfaction of Class.
SOLAS (14) V/20.2
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 19 September 2019
Resolution: Mackay Marine attended the vessel on 18 June 2019, installed new power supply module and new batteries, tested, and confirmed SVDR was fully working.
Pollution Prevention/Response › Prevention Equipment › Oily Water Separator (15 ppm)
Issued 13 December 2017
Resolved
The automatic stopping device should consist of a valve arrangement installed in the effluent outlet line of the 15 ppm Bilge Separator which automatically diverts the effluent mixture from being discharged overboard back to the ship’s bilges or bilge tank when the oil content of the effluent exceeds 15ppm. The automatic stopping device not operational. MARPOL I/14.6 and MEPC 107(49)3.6.
Action required: 705 - Other - as specified
Due 19 January 2018
Resolved 18 December 2017
Resolution: Three way OWS diverter valve was repaired and SAT operation demonstrated during 18DEC2017 CG attendance.
Communications › Alarms/Indicators › Steering Failure Alarm System
Issued 13 December 2017
Resolved
In the event of a failure of electrical power supply to the control system, and aduble and visual alarm shall be given on the navigation bridge. Both port and staboard visual and audible alarms did not indicate when power was secured to steering.
Action required: 705 - Other - as specified
Resolved 13 January 2018
Resolution: To the satisfaction of the ABS Surveyor.
Fire Fighting › Means of Escape › Blocked
Issued 13 December 2017
Resolved
Escape routes shall be maintained in a safe condition, clear of obstacles. Remove the refrigerant compressed gas cylinder stowed in the machinery space emergecy escape.
Action required: 705 - Other - as specified
Resolved 18 December 2017
Resolution: The cylinder was moved while we were on board.
Fire Fighting › Means of Escape › Doorways
Issued 13 December 2017
Resolved
Fire doors in...stairway enclosures shall be self-closing and capable of closing with an angle of inclination of up to 3.5 deg opposing closure. Self closing door in cargo space C-6 does not close.
Action required: 705 - Other - as specified
Resolved 13 December 2017
Resolution: Provided to ABS Surveyor iaw ACP.
Construction/Loadline › Penetrations › Pipe Flange
Issued 13 December 2017
Resolved
Discharges led through the shell either from spaces below the freeboard deck or from within superstructures and deckhouses on the freeboard deck fitted with doors...shall be fitted with accessible means for preventing water from passing inboard. Repair broken oily water drain line for C-1 deck hatch coaming.
Action required: 705 - Other - as specified
Resolved 13 December 2017
Resolution: Provided to ABS Surveyor iaw ACP.
Lifesaving › Embarkation Appliances/Stations › Accessability
Issued 13 December 2017
Resolved
Muster and embarkation stations shall be adequately illuminated. The liferaft embarkation station lights were heavily rusted and the grounding wires were not attached.
Action required: 705 - Other - as specified
Resolved 13 December 2017
Resolution: Provided to the ABS Surveyor to clear iaw ACP.
Lifesaving › Lifeboat › Propulsion Engine
Issued 13 December 2017
Resolved
All life-saving appliances shall be in working order and ready for immediate use. The #1 and #2 lifeboats failed to shutdown when secured.
Action required: 705 - Other - as specified
Resolved 18 December 2017
Resolution: Provided to the ABS Surveyor to clear iaw ACP.
Lifesaving › Lifeboat Equipment › Food Ration
Issued 13 December 2017
Resolved
Survival craft shall be stowed fully equipped as required by the code. The rations shall be kept in airtight packaging. Replace 02rations in lifeboat #3 with broken vacuum packed seal.
Action required: 705 - Other - as specified
Resolved 7 August 2018
Resolution: Provided to the ABS Surveyor to clear iaw ACP.
Lifesaving › Lifeboat Equipment › First Aid Kit
Issued 13 December 2017
Resolved
Survival craft shall be stowed fully equipped as required by the code. One first-aid kit outfit in a water proof kit. Replace expired ammonia inhalants and missing eye flush kit in each of the 4 lifeboats.
Action required: 705 - Other - as specified
Resolved 18 December 2017
Resolution: Provided to the ABS Surveyor to clear iaw ACP.
Lifesaving › Embarkation Appliances/Stations › Designated Location
Issued 13 December 2017
Resolved
Each muster station shall have sufficient clear deck space to accommodate all persons as assigned to muster at that station. Remove the cable laying across the deck and hand rail at the starboard lifeboat embarkation deck.
Action required: 705 - Other - as specified
Resolved 18 December 2017
Resolution: Provided to the ABS Surveyor to clear iaw ACP.
Operations/Management › Vessel Safety Management › External Certification/Verification/Control
Issued 13 December 2017
Resolved
A copy of the Document of Compliance shall be kept on board the ship in orer that the master can produce it on request for verification. The ISM DOC was unavailable for inspection.
Action required: 705 - Other - as specified
Resolved 13 December 2017
Resolution: The master was able to obtain a copy of the company's DOC.
Lifesaving › Lifebuoys › Markings (ship name/port)
Issued 13 December 2017
Resolved
Lifebuoys shall be marked in block capitals...the name and port of registry. All lifebuoys are missing the port of registry.
Action required: 705 - Other - as specified
Resolved 13 January 2018
Resolution: Provided to the ABS Surveyor to clear iaw ACP.
Lifesaving › Lifebuoys › Serviceable
Issued 13 December 2017
Resolved
Lifebuoys complying with the requirements of 2.1.1 of the code...be fitted with a grab line. Several grablines were wasted on the lifebuoys and noted to the chief mate.
Action required: 705 - Other - as specified
Resolved 13 December 2017
Resolution: Provided to the ABS Surveyor to clear iaw ACP.
Construction/Loadline › Penetrations › Pipe Flange
Issued 13 December 2017
Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or persons on board. In hold C, several valves an valve handles were wasted and/or missing to the chill water piping.
Action required: 705 - Other - as specified
Resolved 13 December 2017
Resolution: Provided to the ABS Surveyor to clear iaw ACP.
Lifesaving › Launching Appliances › Winch
Issued 13 December 2017
Resolved
Each survival craft shall be stowed fully equipped as required by...the code. All parts requiring regular maintenance by the ship's crew shall be readily accessible and easily maintained. Make repairs and conduct maintenance to the starboard lifeboat winch motors and adjacent piping.
Action required: 705 - Other - as specified
Resolved 13 December 2017
Resolution: Provided to the ABS Surveyor to clear iaw ACP.
Fire Fighting › Fire Hydrants › Condition
Issued 13 December 2017
Resolved
Fire-fighting systems and appliances shall be kept in good working order. Repai, clean up and maintain fire hydrants on all decks and ensure they are no longer leaking.
Action required: 705 - Other - as specified
Resolved 13 December 2017
Operations/Management › Drills/Instruction › Not Conducted
Issued 13 December 2017
Resolved
Prior to activation: Conduct satisfactory abandon ship and fire drill, review manning/MMD in accordance with COI, Provide updated and corrected charts.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 7 August 2018
Resolution: Vessel was properly manned and sat drills for fire and abandon ship were completed.
Operations/Management › Vessel Safety Management › Maintenance of Ship/Equipment
Issued 8 December 2017
Resolved
Vessel's Periodic Testing of Vital System Automation is lacking the procedures to adequately perform the periodic safety tests required by 46 CFR 61.40-6 and 46 CFR 61.40-10. The current revision of the vessel's PSTP was approved by the USCG in 2002, but it fails to address several of the systems required by the regulations. Deficiency was originally issued by Sector Corpus Christi on 29JAN2016, ABS Seattle has requested for an extension to complete PSTP changes and granted by Sector Puget Sound OCMI.
Action required: 705 - Other - as specified
Due 31 May 2018
Resolved 7 August 2018
Resolution: Approved PSTP's and letter from USCG MSC issued August 1, 2018. Procedures tested and observed by ABS.
Fire Fighting › Fixed Fire Detection System › Control Panel
Issued 8 December 2017
Resolved
Any required fixed fire detection and fire alarm system with manually operated call points shall be capable of immediate operation at all times. The installed fire detection panel displays a system fault. 74SOLAS(2001) II-2/13.1.1
Action required: 705 - Other - as specified
Due 19 January 2018
Resolved 3 January 2018
Resolution: See Classification report in activity documents.
Engineering › Fuel Oil Service System › Pump
Issued 8 December 2017
Resolved
The machinery, boilers and other pressure vessels, associated piping systems and fittings shall be of a design and construction adequate for the service for which they are intended and shall be so installed and protected as to reduce minimum danger to persons on board. The #1 Fuel Oil boost pump in the engine room has excessive leakage from the pump housing. 74SOLAS(2004) II-1/26.1
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 19 January 2018
Resolved 3 January 2018
Resolution: See Classification report in activity documents.
Engineering › Fuel Oil Service System › Gauge
Issued 8 December 2017
Resolved
The machinery, boilers and other pressure vessels, associated piping systems and fittings shall be of a design and construction adequate for the service for which they are intended and shall be so installed and protected as to reduce minimum danger to persons on board. The Fuel Oil gauges installed on the Ships Service Diesel Generators are not reading accurately. 74SOLAS(2004) II-1/26.1
Action required: 705 - Other - as specified
Due 19 January 2018
Resolved 18 December 2017
Resolution: The four Fuel Oil ship service diesel generators were repaired/replaced and operation proven during CG attendance on 18DEC2017.
Electrical › Electrical Distribution System (service) › Ground Detection
Issued 8 December 2017
Resolved
When a distribution system, whether primary or secondary, for power, heating or lighting, with no connection to earth is used, a device capable of continuously monitoring the insulation level to earth and of giving an audible or visual indication of abnormally low insulation values shall be provided. The 1SA 4,160V ground detection indicator lights on main switchboard are not operational. 74SOLAS(2004)II-1/45.4.2
Action required: 705 - Other - as specified
Due 19 January 2018
Resolved 3 January 2018
Resolution: See Classification report in activity documents.
Electrical › Electric Generation Source (emergency) › Generator
Issued 8 December 2017
Resolved
The machinery, boilers and other pressure vessels, associated piping systems and fittings shall be of a design and construction adequate for the service for which they are intended and shall be so installed and protected as to reduce minimum danger to persons on board. The Emergency Diesel Generator main exhaust trunk has excessive carbon blow by that has left obvious staining on the exhaust shielding and is visible up to five seconds after engine start up. 74SOLAS(2004) II-1/26.1.
Action required: 705 - Other - as specified
Due 19 January 2018
Resolved 3 January 2018
Resolution: See Classification report in activity documents.
Engineering › Steam Boiler (auxiliary/waste heat) › Automation Equipment
Issued 8 December 2017
Resolved
The machinery, boilers and other pressure vessels, associated piping systems and The machinery, boilers and other pressure vessels, associated piping systems and intended and shall be so installed and protected as to reduce minimum danger to persons on board. The #1 auxiliary boiler was not operational at time of inspection. Prove operation of boiler and required safety arrangements required for unattended boilers IAW 74SOLAS(2004) II-1/26.1 and 74SOLAS(2004) II-1/32.2.
Action required: 705 - Other - as specified
Due 19 January 2018
Resolved 3 January 2018
Resolution: See Classification report in activity documents.
Navigation › Collision/Grounding Avoidance › Echo-sounding Device Recorder
Issued 8 December 2017
Resolved
The echo depth sounder must have a device that can continuously record the depth readings of the vessel's echo depth sounding device. The vessel does not have an echo depth sounding recording device.
Action required: 17 - Rectify deficiencies prior to departure
Due 20 January 2018
Resolved 18 January 2019
Fire Fighting › Portable CO2 Fire Extinguisher › Location
Issued 8 December 2017
Resolved
Fire-fighting systems shall be kept in good working order and readily available for use. 5 fire extinguishers were improperly stowed in coaming aft of machinery space emergency escape in hold C.
Action required: 705 - Other - as specified
Resolved 18 December 2017
Resolution: The fire extinguishers were removed from the coaming.
Lifesaving › Lifebuoys › Stowage
Issued 8 December 2017
Resolved
Containers, brackets, racks, and other similar stowage locations for life-saving equipment shall be marked with symbos in accordance with the recommandtions of the Organization (resolution A.760(18)). Replace wasted bridge wings IMO markins for life rings, rocket parachute flares, and line-throwing appliances. Place IMO makrings at each lifering stoage location on the main deck. Marking must indicated wheither its a lifebuoy, lifebuoy with line, lifebuoy with light, or lifebuoy with light and smoke.
Action required: 705 - Other - as specified
Resolved 18 December 2017
Resolution: Provided to the ABS Surveyor to clear iaw ACP.
Fire Fighting › Miscellaneous Items › Insulation (Penetration of Oil/Oil Vapors)
Issued 8 December 2017
Resolved
Ro-ro cargo spaces, spaces as defined in regulation3.49, Cargo spaces intended for the carriage of motor vehicles with fuel in their tanks for their own propulsionshall maintain the appropriate fire integrity standards. A 1 ft by 2 ft section of structural fire protection insulation has been damged and is missing from bulkhead in the foward part of cargo space C-3. Repair section of missing insulation.
Action required: 705 - Other - as specified
Resolved 18 December 2017
Resolution: Provided to ABS Surveyor iaw ACP.
Construction/Loadline › Structures › Deck Plating
Issued 8 December 2017
Resolved
Substantial steel wastage found in hold F in the deck, near ventilation fans, and watertight bulkheads. Conduct UT gauging throught the hold to determine extent of steel wastage and compare results with original plans. Provide CG with analysis.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 18 January 2019
Lifesaving › Lifeboat › Propulsion Engine
Issued 28 February 2017
Resolved
Lifeboat #3 start solenoid is stuck in open position preventing immediate use. Each lifesaving appliance must be in working order and available for immediate use. Repair lifeboat to full operational status.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 1 March 2017
Resolution: ABS verified Life Boat No. 3 fully operational with both primary and secondary means of starting. It was determined a loose connection on the fuel solenoid prevented earlier start attempts.
Documentation › Certificates/Documents › IOPP Certificate
Issued 22 November 2016
Resolved
Retention capacity for F/O purifier sludge tank 4.16 differs from IOPP capacity of 3.6. Clarify with ABS surveyor.
Action required: 705 - Other - as specified
Due 22 December 2016
Resolved 2 December 2016
Resolution: Vessel made log entry and sent copy, uploaded to system. Copy is named IOPP Log Entry 30 nov 2016
Construction/Loadline › Structures › Door
Issued 22 November 2016
Resolved
ECR door rated A60 in Fire control plan, has inoperable latch. Door must be equivilant to the division in which they are fitted and must be reasonably gas tight and self closing.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 22 January 2017
Resolved 20 January 2017
Resolution: Latch assembly was replaced. Door is reasonably gas tight and self closing. Photograph provided
Operations/Management › Pollution › Shipboard Incineration
Issued 22 November 2016
Resolved
Supplemental shipboard incinerator approved means of disposal of oil residues is not operable.
Due 22 February 2017
Resolved 28 February 2017
Resolution: Verified operational incinerator and means or oil residue disposal.
Operations/Management › Drills/Instruction › Not Conducted
Issued 22 November 2016
Resolved
Vessel must demonstrate Fire and abandon ship drills in the presence of attending Coast Guard marine inspector prior to activation of vessel.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 18 January 2017
Resolution: Re-issued new 835 to reflect requirement prior to underway or activation.