LADY CAROLINE

LADY CAROLINE is a 2002 passenger vessel (inspected). The Coast Guard has recorded 84 inspections since 2001, most recently in August 2026, along with 142 deficiencies — 1 with no resolution recorded —, 2 operational controls and 4 casualty investigations between 2007 and 2025.

Records from 2001 to 2026. Most recent: inspection, 6 August 2026.

Built
2002
Last inspected
6 August 2026
Documentation
Valid · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WDN4892
513639
Flag
UNITED STATES
368285150
Maury page id
psix-513639

Inspections, by type

…with no type recorded9
…past their stated due date1
Years with a record 25 calendar years (2001–2026)
The 84 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Registered dimensions (L × B × D)94.8 ft × 33.0 ft × 9.8 ft
Registered tonnagegross 97 / net 87
ITC dimensions (L × B × D)94.8 ft × 33.0 ft × 9.8 ft
ITC tonnagegross 682 / net 223
BuilderKEITH MARINE INC · PALATKA, FL, UNITED STATES · built 2002
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portCLEVELAND, OH
Trade endorsementsCoastwise, unrestricted, Recreational
DocumentationValid · issued 23 April 2026 · expires 30 April 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it97 - Regulatory (Subpart C or D), Gross Ton
682 - Convention (Subpart B), Gross Ton
87 - Regulatory (Subpart C or D), Net Ton
223 - Convention (Subpart B), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

WDN4892MMSI 368285150 · active · compulsorily equipped · granted 15 November 2022, expires 15 November 2032
WDG7860MMSI 367571560 · expired · compulsorily equipped · granted 24 April 2013, cancelled 15 July 2023
WDC5320MMSI 367039370 · expired · compulsorily equipped · granted 5 May 2005, cancelled 11 July 2015
WDA8646MMSI 366856550 · expired · compulsorily equipped · granted 7 June 2002, cancelled 11 August 2012 · licensed under a name not among this hull’s recorded names (not shown)
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspected as a tow unit · 1

The Coast Guard recorded this vessel and the following in the same inspection activity — normally a tug and the barges in its tow. A recreational or unclassed hull in the same activity is held and not published, so it does not appear here: these lists are a floor, not a complete manifest.

CELESTIAL Passenger (Inspected) · MISLE 486609 · 2 March 2016 · activity 5839060

Inspection history · 84

6 August 2026 Administrative Inspection · Damage Survey · Deficiency Check
Physical examination · Marine Safety Unit Cleveland · USCG Great Lakes District (CGD-GL) · Activity 8456567
13 March 2026 Administrative Inspection · Deficiency Check · Vessel Attendance
Physical examination · Marine Safety Unit Cleveland · USCG Great Lakes District (CGD-GL) · Activity 8338813
5 December 2025 In-Service Inspection
Physical examination · Marine Safety Unit Cleveland · USCG Great Lakes District (CGD-GL) · Activity 8277322
19 November 2025 Inclining Experiment
Physical examination · Marine Safety Unit Cleveland · USCG Great Lakes District (CGD-GL) · Activity 8279044
21 October 2025 In-Service Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Cleveland · USCG Great Lakes District (CGD-GL) · Activity 8256481
14 October 2025 Deficiency Check · Administrative Inspection
Physical examination · Marine Safety Unit Cleveland · USCG Great Lakes District (CGD-GL) · Activity 8251498
4 October 2025 Type not recorded
No type recorded · Marine Safety Unit Cleveland · USCG Great Lakes District (CGD-GL) · Activity 8308575
3 October 2025 In-Service Inspection · Damage Survey · Deficiency Check · Administrative Inspection
Physical examination · Marine Safety Unit Cleveland · USCG Great Lakes District (CGD-GL) · Activity 8246168
25 September 2025 DAPI Audit
Administrative · Sector Eastern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 8243087
24 September 2025 In-Service Inspection
Physical examination · Marine Safety Unit Cleveland · USCG Great Lakes District (CGD-GL) · Activity 8240478
31 August 2025 Deficiency Check · Annual Inspection · Damage Survey
Physical examination · Marine Safety Unit Cleveland · USCG Great Lakes District (CGD-GL) · Activity 8221945
31 August 2025 Type not recorded
No type recorded · Marine Safety Unit Cleveland · USCG Great Lakes District (CGD-GL) · Activity 8259179
31 August 2025 Type not recorded
No type recorded · Marine Safety Unit Cleveland · USCG Great Lakes District (CGD-GL) · Activity 8307103
20 November 2024 Hull Examination · In-Service Inspection · Internal Structural Exam
Physical examination · Marine Safety Unit Cleveland · USCG Great Lakes District (CGD-GL) · Activity 8037420
20 June 2024 Annual Inspection · Deficiency Check · MTSA Verification
Physical examination · Marine Safety Unit Cleveland · USCG Great Lakes District (CGD-GL) · Activity 7938799
21 February 2024 Administrative Inspection
Administrative · Marine Safety Unit Cleveland · USCG Great Lakes District (CGD-GL) · Activity 7868269
17 October 2023 Deficiency Check · Administrative Inspection
Physical examination · Marine Safety Unit Cleveland · USCG Great Lakes District (CGD-GL) · Activity 7810297
12 October 2023 Administrative Inspection · Deficiency Check
Physical examination · Marine Safety Unit Cleveland · USCG Great Lakes District (CGD-GL) · Activity 7807796
10 October 2023 DAPI Audit
Administrative · Sector Eastern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 7807436
12 September 2023 Type not recorded
No type recorded · Sector Eastern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 7833655
5 September 2023 Deficiency Check · In-Service Inspection
Physical examination · Marine Safety Unit Cleveland · USCG Great Lakes District (CGD-GL) · Activity 7785858
25 August 2023 Deficiency Check
Physical examination · Marine Safety Unit Cleveland · USCG Great Lakes District (CGD-GL) · Activity 7781714
24 August 2023 Deficiency Check
Physical examination · Marine Safety Unit Cleveland · USCG Great Lakes District (CGD-GL) · Activity 7775642
17 August 2023 Damage Survey · Deficiency Check
Physical examination · Marine Safety Unit Cleveland · USCG Great Lakes District (CGD-GL) · Activity 7771119
7 July 2023 DAPI Audit · COI Inspection
Physical examination · Marine Safety Unit Cleveland · USCG Great Lakes District (CGD-GL) · Activity 7738395
8 May 2023 COI Inspection
Physical examination · Marine Safety Unit Cleveland · USCG Great Lakes District (CGD-GL) · Activity 7683787
13 March 2023 In-Service Inspection · Examination of Repairs
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7659789
1 November 2022 Drydock Exam · Internal Structural Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7577494
11 April 2022 Deficiency Check · Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7428855
20 April 2021 Deficiency Check · Examination of Repairs · Annual Inspection · Administrative Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7178816
6 November 2020 Hull Examination · Internal Structural Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7091012
20 May 2020 Annual Inspection · MTSA Verification · Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6956551
16 April 2019 Annual Inspection · MTSA Verification
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6661413
20 November 2018 Drydock Exam · Internal Structural Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6584958
10 April 2018 COI Inspection · MTSA Verification · Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6388534
30 October 2017 Deficiency Check · Administrative Inspection
Physical examination · Navigation Center · Activity 6297552
22 August 2017 Annual Inspection · Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6248050
18 November 2016 Hull Examination · Internal Structural Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6043865
30 August 2016 Deficiency Check · Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 5986830
3 March 2016 Damage Survey · Examination of Repairs
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 5832549
2 March 2016 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 5839060
21 October 2015 Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 5747636
23 September 2015 Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 5727070
5 June 2014 Drydock Extension
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 4890102
23 May 2012 Administrative Inspection
Administrative · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 4319893
7 September 2011 Deficiency Check
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 4183795
6 September 2011 MTSA Verification · DAPI Audit · Annual Inspection
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 4138588
19 August 2011 In-Service Inspection
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 4120851
20 December 2010 Damage Survey
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 3916936
16 September 2010 Deficiency Check
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 3851353
8 March 2010 Administrative Inspection · Deficiency Check
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 3691646
16 July 2009 Deficiency Check
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 3536704
13 July 2009 Administrative Inspection
Administrative · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 3534045
10 September 2008 Deficiency Check
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 3321873
6 June 2008 Administrative Inspection
Administrative · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 3234757
12 May 2008 Annual Inspection · MTSA Verification
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 3144082
27 July 2007 Deficiency Check
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 3033585
6 July 2007 Administrative Inspection
Administrative · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 2985595
8 June 2007 Annual Inspection
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 2906102
12 March 2007 In-Service Inspection
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 2886571
22 January 2007 Deficiency Check
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 2859882
4 January 2007 Administrative Inspection · In-Service Inspection
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 2850023
3 January 2007 Type not recorded
No type recorded · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 2852375
27 April 2006 Deficiency Check
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 2634539
25 April 2006 Annual Inspection
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 2633370
29 March 2006 Hull Examination
Physical examination · Marine Safety Unit Sturgeon Bay · USCG Great Lakes District (CGD-GL) · Activity 2611469
28 March 2006 Administrative Inspection · Deficiency Check
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 2611089
14 March 2006 Deficiency Check
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 2602398
18 January 2006 Administrative Inspection
Administrative · Marine Safety Center (MSC) · Activity 2568875
1 July 2005 Security Plan Review - ASP
Administrative · Marine Safety Center (MSC) · Activity 2410428
3 June 2005 Administrative Inspection · COI Inspection · MTSA Verification · Deficiency Check
Physical examination · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 2374350
23 May 2005 Deficiency Check
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 2366113
28 April 2005 In-Service Inspection
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 2344640
9 March 2005 Administrative Inspection
Administrative · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2305743
22 June 2004 Annual Inspection · Deficiency Check
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 2107281
25 May 2004 Hull Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 2078159
3 May 2004 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 2058054
1 May 2004 Type not recorded
No type recorded · Station Fort Lauderdale · USCG Southeast District (CGD-SE) · Activity 2092291
17 December 2003 Security Plan Review - ASP
Administrative · Marine Safety Center (MSC) · Activity 1968521
3 November 2003 Administrative Inspection
Administrative · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1940990
21 July 2003 Re-Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1852545
9 November 2002 Type not recorded
No type recorded · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1703230
11 June 2002 Initial Certification
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1628997
18 September 2001 Hull Examination · Deadweight Survey · Initial Construction-Excluding Oversight
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1615492

Deficiency record · 142

07 - Fire Safety › N/A - No Subsystem › Operation of Fire protection systems
Issued 21 October 2025 Resolved
A fixed gas fire extinguishing system may be used that automatically discharges upon activation of a heat sensor. Heat sensor did not activate system. System must be repaired to properly function. Function test to be conducted in the presence of a marine inspector within 30 days. Operations prior to repair are authorized because system can still be manually operated. Captain must discuss alternative procedures with crew to ensure fire safety while operating.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 23 November 2025
Resolved 8 June 2026
Resolution: Verified automatic operation of system via test of 02 heat sensors, in presence of fire servicing company.
07 - Fire Safety › N/A - No Subsystem › Operation of Fire protection systems
Issued 21 October 2025 Resolved
A device must be provided to automatically shutdown power ventilation and machinery that draws intake air from within the protected space. Pressure switch did not shut down machinery or ventilation. Demonstrate proper shutdowns during function test in the presence of a marine inspector.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 23 November 2025
Resolved 3 August 2026
Resolution: Verified proper operation of installed shutdowns for M/Es, generators and ventilation.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 3 October 2025 Resolved
The OCMI may require an inspection and testing whenever a repair is made. Vessel captain reported an alarm when trying to clutch their starboard main engine into the forward position. Vessel recently experienced an issue with the same control box and it was replaced. Vessel must return to the dock and troubleshoot the controls and make permanent repairs prior to departure.
Action required: 17 - Rectify deficiencies prior to departure
Due 3 October 2025
Resolved 9 October 2025
Resolution: Control box and cables were replaced, conducted sea trials in the presence of attending marine inspector.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 25 September 2025 Resolved
Lady Caroline LLC did not produce documentation supporting compliance with record keeping regulations. Custody and control forms, signed by the Medical Review Officer, indicating the test was either positive or negative, or a lab report indicating the test was either positive or negative, were not maintained and available during the audit. Two positive pre-employment tests were documented on Lady Caroline LLC’s 2023 MIS report, but test results were not available. Additionally, drug test results were not provided for four random and four pre-employment drug tests conducted in 2024.
Action required: 10 - Deficiency Rectified
Due 30 September 2025
Resolved 30 September 2025
Resolution: On September 30, 2025, Lady Caroline LLC provided U.S. Coast Guard Sector Eastern Great Lakes with documentation that supported the company’s compliance with record keeping regulations.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 25 September 2025 Resolved
Lady Caroline LLC employed crewmembers onboard the U.S. Coast Guard inspected passenger vessel Lady Caroline (O.N. 1124961) in 2025 without having conducted pre-employment drug tests and having negative results on file.
Action required: 10 - Deficiency Rectified
Due 31 October 2025
Resolved 30 September 2025
Resolution: Lady Caroline LLC conducted pre-employment drug tests for all crewmembers serving onboard Lady Caroline on September 10, 2025, and negative test results are now on file.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 25 September 2025 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Action required: 10 - Deficiency Rectified
Due 31 October 2025
Resolved 25 September 2025
Resolution: Lady Caroline LLC contracted with USA Mobile Drug Testing of Northeast Ohio on September 10, 2025, to manage Lady Caroline LLC’s random drug testing program.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 25 September 2025 Resolved
Lady Caroline LLC did not produce documentation that supported pre-employment background checks were conducted for employees in safety-sensitive positions who were previously employed by DOT employers.
Action required: 10 - Deficiency Rectified
Due 31 October 2025
Resolved 29 October 2025
Resolution: Pre-employment background checks were conducted for all relevant employees in safety-sensitive positions.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 25 September 2025 Resolved
Lady Caroline LLC did not produce proof that random drug testing was conducted at 50 percent of covered crewmembers for calendar year 2024. Lady Caroline LLC reported having eleven covered crewmembers, and only four random drug tests were conducted.
Due 31 October 2025
Resolved 29 October 2025
Resolution: Lady Caroline LLC is conducting their random drug testing at 50 percent of covered crewmembers for calendar year 2025.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 25 September 2025 Resolved
Lady Caroline LLC’s passenger vessel Lady Caroline had onboard One Step Saliva Alcohol Test Strips that had expired on November 24, 2024.
Due 31 October 2025
Resolved 29 October 2025
Resolution: Lady Caroline LLC purchased new One Step Saliva Alcohol Test Strips for their passenger vessel LADY CAROLINE. However, the One Step Saliva Alcohol Test Strips were not DOT approved and the company was directed to remove these strips from the vessel.
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 11 September 2025 Resolved
Each vessel inspected and certificated under Sub chapter K must, when passengers are on board, be in full compliance with the terms of the Certificate of Inspection. Vessel has routinely been operating without the required manning (Deckhands) as indicated on the Certificate of Inspection.
Action required: 30 - Ship detained
Due 11 September 2025
Resolved 17 September 2025
Resolution: Attended vessel for drills, full crew was on board.
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 11 September 2025 Resolved
Vessels on a Great Lakes route must carry 6 day and 6 night flares of an approved type. Multiple flares on the bridge were expired. Replace expired flares prior to carrying passengers. .
Action required: 701 - Prior to carriage of passengers/cargo
Due 11 September 2025
Resolved 17 September 2025
Resolution: Correct number of flares provided on board.
18 - Maritime Labour Convention (Not Applicable to PSC Exams conducted in the U.S.) › N/A - No Subsystem › Other (Conditions of employment)
Issued 11 September 2025 Resolved
Chemical testing of personnel must be conducted as required by this subpart and in accordance with the procedures detailed in 49 CFR part 40. The company failed to comply with required chemical testing. Crew members have not been enrolled in a random drug testing program since October of 2024. All crew members that perform safety sensitive positions shall receive a preemployment drug test in accordance with 46 CFR 16.210 , receive negative results, and be enrolled in random testing in accordance with 46 CFR 16.230, prior to departure of the vessel. Additionally, the company shall undergo a full Drug and Alcohol inspection audit and come into compliance within 30 days.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 11 September 2025
Resolved 25 September 2025
Resolution: Full DAPI audit conducted by MSU [name withheld] and SEGL SIO.
18 - Maritime Labour Convention (Not Applicable to PSC Exams conducted in the U.S.) › N/A - No Subsystem › Other (Conditions of employment)
Issued 11 September 2025 Resolved
A mariner may not serve under the authority of an MMC past its expiration date. All Masters of the vessel are required to have a valid MMC. Vessel logs indicate that on multiple occasions the vessel was under the control of a mariner without a valid credential. The vessel shall not operate without a valid credentialed mariner.
Action required: 30 - Ship detained
Due 11 September 2025
Resolved 17 September 2025
Resolution: Captain of the vessel had an active MMC.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 31 August 2025 Resolved
Adult and Child size lifejackets must be stowed in a location that is appropriately marked so they cannot be mistaken for the wrong size. Lifejacket containers need to be adequately marked for the size and number of lifejackets contained.
Action required: 701 - Prior to carriage of passengers/cargo
Due 11 September 2025
Resolved 17 September 2025
Resolution: Life jacket boxes were appropriately marked.
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 21 June 2024 Resolved
All escape hatches and other emergency exits used as means of escape must be marked on both sides in clearly legible letters at least 50 millimeters (2 inches) high: "EMERGENCY EXIT, KEEP CLEAR", unless such markings are deemed unnecessary by the cognizant OCMI. Vessel is missing sufficient emergency exit markings in the crew/employee state room. Vessel is to post appropriate markings in employee state room as soon as possible but no later than 7 days.
Action required: 705 - Other - as specified
Due 28 June 2024
Resolved 22 June 2024
Resolution: Vessel posted appropriate markings.
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 21 June 2024 Resolved
All escape hatches and other emergency exits used as means of escape must be marked on both sides in clearly legible letters at least 50 millimeters (2 inches) high: "EMERGENCY EXIT, KEEP CLEAR", unless such markings are deemed unnecessary by the cognizant OCMI. Vessel is missing markings for each of its escape hatches. Vessel is to ensure each escape hatch is clearly marked as soon as possible but no later than 7 days.
Action required: 705 - Other - as specified
Due 28 June 2024
Resolved 22 June 2024
Resolution: All escape hatches properly labeled and clear.
11 - Life Saving Appliances › N/A - No Subsystem › Rescue boats
Issued 20 June 2024 Resolved
In accordance with the Certificate of Inspection, the vessel is required to carry a suitable rescue boat to safely and efficiently retrieve a person in the water. The crew is to prove proper operation of this boat prior to carrying passengers.
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Due 20 June 2024
Resolved 21 June 2024
Resolution: Witnessed satisfactory MOB drill w/launch & recovery of the rescue boat.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 20 June 2024 Resolved
IAW the 72 COLREGS, Rule 34, a power driven vessel must have the ability to make required sound signals, while underway. The vessel is temporarily using freon activated horns until their replacement air compressor arrives. Must prove proper operation of air compressor system by 20JUL2024.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 20 June 2024
Resolved 21 June 2024
Resolution: Small air compressor was installed on the bridge, and the ship's air horn tested satisfactorily.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 20 June 2024 Resolved
There are exposed wires in the vicinity of the STBD Side control station. These must be appropriately secured and/or de-energized prior to carrying passengers.
Action required: 701 - Prior to carriage of passengers/cargo
Due 20 June 2024
Resolved 21 June 2024
Resolution: Exposed wires were properly encased into an electrical box. Deficiency is cleared.
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 20 June 2024 Resolved
The high water alarm did not function when tested. Prove proper operation of the high water level alarm prior to carrying passengers.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 20 June 2024
Resolved 21 June 2024
Resolution: High water alarm functions as intended and sounds at the operating station as required. Deficiency is cleared.
09 - Working and Living Conditions › 092 - Working Conditions › Holds and tanks safety
Issued 20 June 2024 Resolved
Excess gear, lube oil, and cleaning solvents must be removed or securely stowed to prevent blocking escape routes or creating a hazard. Clean spaces to the satisfaction of the marine inspector prior to carrying passengers.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 20 June 2024
Resolved 22 June 2024
Resolution: All spaces were found to be in order and the deficiency is cleared.
09 - Working and Living Conditions › 092 - Working Conditions › Obstruction/slipping, etc.
Issued 20 June 2024 Resolved
Shelving used for storage is not secured and in danger of collapsing and or dumping its contents. Secure the shelves to the satisfaction of the attending Marine Inspector, prior to carrying passengers.
Condition: Design Flaw
Action required: 701 - Prior to carriage of passengers/cargo
Due 20 June 2024
Resolved 22 June 2024
Resolution: All items were secured and appropriate tie-downs in place. The deficiency is cleared.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 30 May 2024 Resolved
THE VESSEL IS IN THE PROCESS OF REPLACING THE GENERATORS, ELECTRICAL PANELS, GALLEY EQUIPMENT, FLOORING ETC. DUE TO THIS ONGOING WORK, THE VESSEL MAY NOT LEAVE THE DOCK WITH PASSENGERS UNTIL THE [name withheld] OF PENDING WORK.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 21 June 2024
Resolution: OCMI approved vessel to operate with 263 passengers on board until new stability letter is issued.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 21 March 2024 No resolution recorded
The construction and arrangement of a vessel must allow the safe operation of the vessel in accordance with the terms of its Certificate of Inspection giving consideration to provisions for a seaworthy hull, protection against fire, means of escape in case of sudden expected , and necessary facilities for passengers and crew. The vessel is in the process of replacing the generators, electrical panels, galley equipment, flooring, etc. Vessel is awaiting final approval from MSC for an updated stability letter. Until the new stability letter is issued, vessel is only permitted to carry 263 persons onboard. No more than 173 passengers are permitted on the top deck at any time. All other conditions of the COI are to be met at all times while passengers are onboard.
Action required: 705 - Other - as specified
Due 15 July 2024 — due date passed with no resolution recorded
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 17 October 2023 Resolved
Vessel control systems must be suitable for the purpose intended. Vessel's propulsion controls from the starboard operating station is inoperable. Vessel is to prove operation of propulsion controls from the starboard operation station with a technician's report and to the satisfaction of the Coast Guard prior to the carrying passengers.
Action required: 701 - Prior to carriage of passengers/cargo
Due 19 October 2023
Resolved 18 October 2023
Resolution: CG marine inspector witnessed the operation of each control station.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 10 October 2023 Resolved
Lady Caroline LLC did not produce proof that they were complying with record keeping regulations. Custody and control forms, signed by the Medical Review Officer, indicating that the test was either positive or negative, or a lab report indicating the tests are either positive or negative, were not maintained and available during the audit.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 November 2023
Resolved 10 November 2023
Resolution: Obtained documentation to demonstrate compliance with requirements outlined in 46 CFR § 16.260 and 49 CFR § 40.333.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 10 October 2023 Resolved
Lady Caroline LLC did not produce proof that MIS reports were submitted to U.S. Coast Guard Headquarters.
Action required: 705 - Other - as specified
Due 30 November 2023
Resolved 10 November 2023
Resolution: Lady Caroline LLC submited a MIS report for calendar year 2022 to U.S. Coast Guard Headquarters.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 10 October 2023 Resolved
Lady Caroline LLC employed an individual on September 12, 2023, as a deckhand aboard Lady Caroline, a position required by the vessel’s Certificate of Inspection, without conducting a pre-employment drug test.
Action required: 17 - Rectify deficiencies prior to departure
Due 30 November 2023
Resolved 10 November 2023
Resolution: Lady Caroline LLC removed the individual from engaging or being employed as a crewmember until pre-employment testing requirements outlined in 46 CFR § 16.210 are complied with.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 10 October 2023 Resolved
Lady Caroline LLC did not produce proof that pre-employment background checks for employees in safety-sensitive positions who were previously employed by DOT employers were conducted.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 November 2023
Resolved 10 November 2023
Resolution: Individuals hired and employed during calendar year 2023 and meeting requirements of 49 CFR § 40.25 underwent a pre-employment background check.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 10 October 2023 Resolved
Lady Caroline LLC did not produce proof that random drug testing was conducted at 50 percent of covered crewmembers. In addition, two (2) employees acknowledged Lady Caroline LLC’ Drug and Alcohol Policy but were not included on the list of crewmembers enrolled in the company’s random drug testing program.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 November 2023
Resolved 10 November 2023
Resolution: Lady Caroline provided documentation that demonstrated random drug testing was conducted at 50 percent for covered crewmembers in 2023. Additionally, an accurate list of crewmembers enrolled in the company’s random drug testing program was provided.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 10 October 2023 Resolved
Lady Caroline LLC employed an individual on September 12, 2023, as a deckhand aboard Lady Caroline, a position required by the vessel’s Certificate of Inspection, without enrolling the individual in a random drug testing program.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 November 2023
Resolved 10 November 2023
Resolution: Lady Caroline LLC removed the individual from engaging or being employed as a crewmember until random testing requirements outlined in 46 CFR § 16.230 are complied with.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 10 October 2023 Resolved
Although no SMIs reportedly occurred onboard Lady Caroline LLC’s vessels, Lady Caroline LLC was not familiar with alcohol and drug testing requirements following a SMI and the company’s written policy did not identify these requirements. Furthermore, alcohol testing strips onboard Lady Caroline had expired on March 31, 2020. Lady Caroline LLC did not have a third-party contract for alcohol testing or a plan in place for conducting SMI drug and alcohol testing.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 November 2023
Resolved 10 November 2023
Resolution: Lady Caroline LLC familiarized itself with requirements outlined in 46 CFR § 16.240 and 46 CFR § 4.06-03 and implemented internal procedures for conducting post-SMI drug and alcohol testing.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 10 October 2023 Resolved
Lady Caroline LLC’s written drug and alcohol policy did not provide the name(s) and contact information for the SAP(s) that may be used by Lady Caroline LLC for drug test violations.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 November 2023
Resolved 10 November 2023
Resolution: Lady Caroline LLC identified and documented SAP(s) along with their contact information.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 10 October 2023 Resolved
Lady Caroline LLC maintained documentation attesting that each crewmember acknowledged they read and understood Lady Caroline LLC’s Drug and Alcohol Policy, with the exception of one (1) crewmember who was listed on their random drug testing list. However, Lady Caroline LLC’s Drug and Alcohol Policy did not address: (1) an explanation of what constitutes a refusal to test; (2) the signs and symptoms of drug use and alcohol misuse; (3) information on the effects of drugs and alcohol on a person’s health, work, and personal life; (4) and training requirements for supervisors and other officials about reasonable suspicion and reasonable cause testing (i.e. indicators of probable drug use (1 hour) and indicators of probable alcohol use (1 hour)).
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 November 2023
Resolved 10 November 2023
Resolution: Lady Caroline LLC obtained documentation attesting that each crewmember acknowledged they read and understood Lady Caroline LLC’s Drug and Alcohol Policy.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 5 September 2023 Resolved
Initial requirement written to make the port bridge wing engine control station operational. Upon further inspection, the installation of the engine controls at the three stations (port, center, starboard) is not in compliance with the manufacturer's user manual, covering installation, operation and troubleshooting. Owner must prove proper operation of the engine control system in accordance with published Design Verification Test Procedures and installation of the engine control system as designed.
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Due 3 October 2023
Resolved 4 October 2023
Resolution: Successful DVTP witnessed and installation is IAW manufacturer's User Manual. Deficiency is cleared.
04 - Emergency Systems › N/A - No Subsystem › Emergency source of power - Emergency generator
Issued 17 August 2023 Resolved
Each vessel that relies on electricity to power the listed loads, must be arranged so that the loads can be energized from two sources of electricity. The port SSDG overheated and shut-down. Prove proper operation of the generator prior to carriage of passengers.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 17 August 2023
Resolved 17 August 2023
Resolution: SSDG was repaired and tested in the presence of the CG MI, operating as designed. The deficiency is cleared.
05 - Radio Communications › N/A - No Subsystem › Other (radio communication)
Issued 18 July 2023 Resolved
Stations in the maritime service must be licensed by the FCC either individually or by fleet. Vessel owner must secure FCC Station License within 30 days. 47 CFR 80.13
Action required: 50 - Rectify deficiencies w/in 30 days
Due 16 August 2023
Resolved 25 July 2023
Resolution: Master provided all FCC documents.
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 18 July 2023 Resolved
A means of escape must be adequately marked with clearly legible letters: EMERGENCY EXIT KEEP CLEAR. Spaces must be marked to the satisfaction of the attending Marine Inspector.
Action required: 701 - Prior to carriage of passengers/cargo
Due 21 July 2023
Resolved 25 July 2023
Resolution: All exits are properly marked.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 18 July 2023 Resolved
Vessel control systems must be suitable for the purpose intended. The port wing engine control station is not operational. The deficiency must be rectified within 14 days.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 August 2023
Resolved 4 October 2023
Resolution: Witnessed successful DVTP on the engine control system. Deficiency cleared.
09 - Working and Living Conditions › 092 - Working Conditions › Safe means of access
Issued 11 April 2022 Resolved
46 CFR 116.438(e) A stairway or stair tower must be clear of all obstructions other than handrails. Stairwell on aft of vessel needs to be clear of mooring lines prior to carrying passengers.
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Due 16 April 2022
Resolved 26 April 2022
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 11 April 2022 Resolved
The CO2 system must be capable of automatic operation by a heat actuator within the space. The installed heat actuated disk that allows for automatic discharged of the CO2 system has been disconnected and the internal gas escaped. Provide servicing report by technician that system has been service and tested. In the meantime, fire watch rounds shall be increased to every 15 minutes and logging each round in logbook.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 3 May 2022
Resolved 16 May 2022
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 11 April 2022 Resolved
Electrical equipment on a vessel must be installed and maintained to prevent electrical hazards, including fire, caused by or originating in electrical equipment. Replace one electrical outlet under the bar top on the 4th deck bar and two outlets on the port and starboard forward bulkhead of the 3rd deck that showed signs of charring and melted electrical sockets.
Condition: Damaged By Earlier Event
Action required: 50 - Rectify deficiencies w/in 30 days
Due 3 May 2022
Resolved 26 April 2022
07 - Fire Safety › N/A - No Subsystem › Fire prevention structural integrity
Issued 11 April 2022 Resolved
Penetrations in A-Class fire control boundaries for electrical cables, pipes, trunks, ducts, etc. must be constructed to prevent the passage of flame and smoke for one hour. In addition, the penetration must be designed or insulated so that it will withstand the same temperature rise limits as the boundary penetrated. Structural fire protection in AC/heater closet on navigation Bridge and in the engine room bulkhead starboard side aft require re-packing of insulation in the penetrations.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 3 May 2022
Resolved 26 April 2022
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 11 April 2022 Resolved
46 CFR 120.340 (b) (4) All cables and wire must be installed with metal supports spaced not more than 24 inches apart, and in such a manner as to avoid chafing and other damage. The use of plastic tie wraps must be limited to bundling or retention of multiple cable installations, and not used as a means of support. Wires underneath navigation bridge counsel must be supported with metal holds.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 3 May 2022
Resolved 26 April 2022
07 - Fire Safety › N/A - No Subsystem › Fire prevention structural integrity
Issued 11 April 2022 Resolved
A door in a stairtower, stairway, and main vertical zone bulkhead must be of the self-closing type capable and holdback hooks are not allowed. If installed, a hold back mechanism for a door must allow the door to be released. Fire door on stairwell top deck must be adjusted to close completely unassisted and hinged foot hold back removed.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 3 May 2022
Resolved 26 April 2022
09 - Working and Living Conditions › 092 - Working Conditions › Structural features (ship)
Issued 11 April 2022 Resolved
Door frames must be of rigid construction and provide at least a 0.5 inch overlap at the sides and top. Aft starboard side door leading towards the engine room has a loose frame and needs to be secured with in its position in the bulkhead.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 3 May 2022
Resolved 26 April 2022
11 - Life Saving Appliances › N/A - No Subsystem › Operation of Life Saving Appliances
Issued 11 April 2022 Resolved
Each item of lifesaving equipment determined by the marine inspector to not be in serviceable condition must be repaired or replaced. Multiple life floats are waterlogged and have increased significantly in weight. Provide proof that all ten of the life floats are in serviceable condition.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 3 May 2022
Resolved 16 May 2022
Resolution: Issued new deficiency with more information
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 11 April 2022 Resolved
All life buoys must be approved and in serviceable working condition. At least one ring life buoy must be fitted with a lifeline. If more than one ring life buoy is carried, at least one must not have a lifeline attached. At least one ring buoy must be fitted with a floating water light, unless the vessel is limited to daytime operation, in that case no floating water light is required. Replace the life lines around the two white life buoys with a UV resistant line. Completely replace the orange life ring located on the aft of the vessel. Provide the additional accessories of the required life line and floating water light.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 3 May 2022
Resolved 16 May 2022
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 11 April 2022 Resolved
A lighting fixture on a vessel must be installed and maintained to provide services necessary for safety under normal and emergency conditions. Light in engine room on port side is out.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 3 May 2022
Resolved 26 April 2022
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 11 April 2022 Resolved
The exhaust piping of the propulsion machinery must be of a corrosion resistant material and capable of operating at constant marine load. The raw water line on the port side wet exhaust has a leak. Address this during the upcoming Dry Dock in November 2022.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 12 April 2022
Resolved 26 April 2022
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 11 April 2022 Resolved
Each item of lifesaving equipment determined by the marine inspector to not be in serviceable condition must be repaired or replaced. Multiple life floats are waterlogged and have increased significantly in weight. Provide proof that all ten of the life floats are in serviceable condition. Vessel is restricted to operation within 1 NM on a Lakes/Bays/Sound and Rivers route until rectified.
Action required: 705 - Other - as specified
Due 16 August 2022
Resolved 27 July 2022
Resolution: Vessel is restricted to 1 NM till def is cleared.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 20 April 2021 Resolved
The following spaces must be equipped with a fire detection and alarm system on vessels with no overnight accommodations; public spaces that may be assumed to be occupied by large number of persons when passengers are on board. Vessels fire detection and fire alarm panel was inoperative. Provide proper operation of fire detection and fire alarm panel to satisfactory of attending Coast Guard Marine Inspector. 46 CFR 118.400 (c)
Action required: 701 - Prior to carriage of passengers/cargo
Due 20 April 2021
Resolved 13 May 2021
Resolution: Rectified.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 20 April 2021 Resolved
Electrical equipment on a vessel must be installed to protect passengers, crew, other persons from electrical hazards. Vessels electrical cabinet on main deck had numerous wires, power strip cords, and unnecessary equipment in electrical cabinet. Remove all necessary equipment, power strips and re-organize all wiring to satisfaction of Coast Guard Marine Inspector. 46 CFR 120.200(b)
Action required: 701 - Prior to carriage of passengers/cargo
Due 20 April 2021
Resolved 13 May 2021
Resolution: Rectified.
01 - Certificates & Documentation › 013 - Documents › Survey report file
Issued 20 April 2021 Resolved
Security exercises must be conducted once each calendar year, with no more than 18 months between exercise. Vessel is missing annual security exercise.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 20 May 2021
Resolved 13 May 2021
Resolution: Rectified.
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 20 May 2020 Resolved
The grablines on all life floats need to be replaced.
Action required: 705 - Other - as specified
Due 1 September 2020
Resolved 17 July 2020
Resolution: Received photographs of the installation.
Operations/Management › Vessel Safety Management › Company Responsibilities/Authority
Issued 10 April 2018 Resolved
Vessel was not ready for inspection as required by regulation. Vessel has numerous electrical hazards, blocked means of escape, improper life saving arrangements, etc. All items discussed w/ owner and will be further documented via 835. Vessel must complete their COI Inspection. 46CFR115.404
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 18 April 2018
Resolution: All hazards removed and fire drill completed.
Operations/Management › Drills/Instruction › Not Conducted
Issued 10 April 2018 Resolved
Vessel must complete a security drill with USCG Marine Inspectors. 46CFR115.404
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 18 April 2018
Resolution: Vessel completed satisfactory security drill.
Fire Fighting › Means of Escape › Blocked
Issued 10 April 2018 Resolved
Vessel has designated passenger staterooms with emergency escape ladders. These ladders are blocked with various different materials such as tools and clothing. Vessel must ensure all means of escape are clear and available for use. 46CFR115.830
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 18 April 2018
Resolution: Means of escape are accessible and hazards removed.
Electrical › Electrical Distribution System (service) › Ground Detection
Issued 10 April 2018 Resolved
Vessel's electrical distribution panel is displaying a 2 amp ground to the hull. Vessel must determine the cause of this ground and correct. 46CFR120.200 (b)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 18 April 2018
Resolved 24 September 2018
Resolution: vessel cleared ground.
Fire Fighting › Combustible Materials › Stowage
Issued 10 April 2018 Resolved
Vessel has flammable material and liquid stored in unauthorized spaces changing the space designation for fire load. Vessel must remove all unauthorized materials and use the space in accordance with the space designation as outlined on the Structural Fire Plan. 46CFR115.840
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 18 April 2018
Resolution: All hazardous liquids/material removed.
Lifesaving › Lifefloat › Float Free
Issued 10 April 2018 Resolved
Vessel must properly arrange all life floats and replace reflective material. 46CFR117.130
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 18 April 2018
Resolution: Life floats properly arranged and retro tape replaced.
Documentation › Safety/Response Plans/Programs › Fire Control Plans
Issued 10 April 2018 Resolved
Vessel must provide a correct fire control plan with all required information. 46CFR116.530
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 April 2018
Resolved 5 June 2018
Resolution: Received file of vessel's corrected fire control plan, submitted by naval architect ([name withheld] of Dejong and Lebet N.A. Inc).
Accommodation/Occupational Safety › Occupational Safety › Portable Electric Equipment/Appliances
Issued 10 April 2018 Resolved
All portable electrical equipment require a ground plug, remove all electrical equipment without a grounding plug. 46CFR120.370
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 April 2018
Resolved 18 April 2018
Resolution: All electrical equipment without grounding plugs were removed.
Electrical › Electrical Distribution System (service) › Junction Box
Issued 10 April 2018 Resolved
All outlets exposed to the weather must be waterproof. Replace all non-waterproof outlet covers. 46CFR120.210 (b)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 April 2018
Resolved 18 April 2018
Resolution: Outlets confirmed to be weatherproof.
Electrical › Lighting (service) › Conductor
Issued 10 April 2018 Resolved
External LED lights must have proper electrical cable. Replace with marine grade. 46CFR120.340 (d)(2)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 April 2018
Resolved 18 April 2018
Resolution: Confirmed LED lights were wired with marine grade cable.
Engineering › Pressure Vessel › Marking and Stamping
Issued 10 April 2018 Resolved
Vessel's air compressor is required to be ASME approved. Vessel must provide documentation proving this vessel to be ASME approved or remove/replace with an approved type. 46CFR54.01-5
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 April 2018
Resolved 7 May 2018
Resolution: Received photo documentation of air receiver placard with matching CRN and S/N.
Electrical › Electric Supply System (service) › Cable
Issued 10 April 2018 Resolved
The air compressor is wired with an extension cord. Vessel must properly wire with marine grade wire. 46CFR120.340 (d)(2)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 April 2018
Resolved 18 April 2018
Resolution: Air compressor properly wired with marine grade cable.
Electrical › Electrical Distribution System (service) › Junction Box
Issued 10 April 2018 Resolved
All electrical connections must be made in an enclosure. Vessel must end all bilge alarm connections in a proper enclosure. 46CFR120.340(g)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 April 2018
Resolved 18 April 2018
Resolution: Junction boxes properly installed.
Operations/Management › Vessel Safety Management › Reports and Analysis
Issued 10 April 2018 Resolved
Vessel's galley is not in serviceable condition. Vessel must have a sanitary inspection by the NY City Department of Health. Provide documentation to the USCG. 46CFR115.818
Action required: 16 - Rectify deficiencies w/in 14 days
Due 13 April 2018
Resolved 18 April 2018
Resolution: Galley cleaned and is in serviceable condition.
Operations/Management › Drug and Alcohol Testing › Testing, Pre-employment
Issued 22 August 2017 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Due 22 September 2017
Resolved 5 September 2017
Resolution: Received satisfactory documentation of negative pre-employment drug test results for mbr.
Operations/Management › Drug and Alcohol Testing › EAP Display Requirements
Issued 22 August 2017 Resolved
Provide EAP information and hotline numbers; make accessible to crew.
Due 22 September 2017
Resolved 5 September 2017
Resolution: EAP/hotline numbers posted onboard.
Communications › Radio Communications › VHF Radiotelephone
Issued 22 August 2017 Resolved
Program MMSI number in VHF radio.
Due 22 September 2017
Resolved 11 September 2017
Resolution: Received satisfactory photo documentation of required VHF-DSC capability w/programmed MMSI number.
Navigation › Piloting/Steering › Marine Charts
Issued 22 August 2017 Resolved
Provide updated marine charts, coast pilot, and light list publications.
Due 22 September 2017
Resolved 11 September 2017
Resolution: Received email confirmation that vessel downloaded/printed most recent Light List for vessel, w/satisfactory Coast Pilot and charts.
Lifesaving › Lifebuoys › Markings (ship name/port)
Issued 22 August 2017 Resolved
Stencil vessel name on ring buoy located near bridge.
Due 22 September 2017
Resolved 11 September 2017
Resolution: Received satisfactory photo documentation of stenciled vessel name on ring life buoys.
Lifesaving › Lifefloat › Paddle
Issued 30 August 2016 Resolved
Paddles must be lashed to life floats. 46 CFR 117.175(f)(2).
Action required: 705 - Other - as specified
Due 15 September 2016
Resolved 20 September 2016
Resolution: Received email documentation from owner attesting to correct lashing of paddles.
Lifesaving › Lifebuoys › Buoyant Lifeline
Issued 30 August 2016 Resolved
Renew grab lines on (02) life ring buoys. 46 CFR 117.70(c)(5)
Action required: 705 - Other - as specified
Due 15 September 2016
Resolved 20 September 2016
Resolution: Received email documentation from owner attesting to renewed grab lines on life ring buoys.
Electrical › Electrical Distribution System (service) › Non-conducting Deck Covering
Issued 30 August 2016 Resolved
Install non-conducting mat in front of switchboard. 46 CFR 120.330.
Action required: 705 - Other - as specified
Due 15 September 2016
Resolved 20 September 2016
Resolution: Received email documentation from owner attesting to correct installation of non-conducting mat.
Operations/Management › Lifesaving › Op Readiness/Maintenance/Inspection
Issued 30 August 2016 Resolved
Conduct and log maintenance and inspections as required by 46 CFR 122.720 & 722.
Action required: 705 - Other - as specified
Due 15 September 2016
Resolved 20 September 2016
Resolution: Received email documentation from owner attesting to correct logged maintenance.
Construction/Loadline › Hull › Side Shell
Issued 3 March 2016 Resolved
Port-Stern side shell was crumpled IWO of the main deck egress station.
Action required: 701 - Prior to carriage of passengers/cargo
Due 14 March 2016
Resolved 28 March 2016
Resolution: Final Repairs and weld process All SAT. 835 rescinded.
Construction/Loadline › Structures › Deck Plating
Issued 3 March 2016 Resolved
Port-Stern deck plating was bent IWO 2nd deck egress station, to an extent that warranted a unsafe condition.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 28 May 2016
Resolution: Final Repairs and weld process All SAT. 835 rescinded.
Lifesaving › Lifefloat › Serviceable
Issued 24 September 2015 Resolved
01. Repair/replace identified light fixture on lifefloat.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 24 October 2015
Resolved 21 October 2015
Resolution: Vessel owner replaced light fixture for lifefloat.
Communications › Radio Communications › EPIRB
Issued 24 September 2015 Resolved
02. Replace expired hydrostatic release on EPIRB.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 24 October 2015
Resolved 21 October 2015
Resolution: Vessel owner replaced expired hydro release on EPIRB.
Electrical › Electric Supply System (service) › Battery Installation
Issued 6 September 2011 Resolved
Battery terminals for battery banks in engine were corroded. Corrosion needs to be removed from terminals and connections need to be cleaned. 46CFR115.806(f)
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 6 October 2011
Resolved 6 October 2011
Resolution: Company cleaned off corrosion from battery terminals as required.
Electrical › Electric Supply System (service) › Battery Installation Ventilation
Issued 6 September 2011 Resolved
Battery Boxes in engine room had vent holes that were painted over. Paint needs to be removed from the vent holes to allow the gases produced during recharging to dissipate properly. 46CFR115.806(f)
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 6 October 2011
Resolved 6 October 2011
Resolution: Company removed paint from the battery box vent holes.
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 6 September 2011 Resolved
Protective guard for drive pulley on the outboard side of the Port Generator is missing. Cover must be re-installed or a new cover fabricated and installed to protect personnel from contact with rotating parts. 46CFR116.960
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 6 October 2011
Resolved 6 October 2011
Resolution: Company re-installed missing protective guard for the drive pulley on the outboard side of the Port Generator.
Electrical › Lighting (emergency) › Lighting Fixture
Issued 6 September 2011 Resolved
Add one (1) emergency light fixture in engine room to illuminate the area for the emergency escape hatch so that it can be located by a crewmember if the ship loses power. 46CFR 120.432 & 46CFR116.500(i)
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 6 October 2011
Resolved 6 October 2011
Resolution: Company added one (1) emergency light fixture in the engine room to illuminate area around the emergency escape hatch.
Electrical › Electrical Distribution System (service) › Outlet Box
Issued 6 September 2011 Resolved
Install cover for 120 volt receptacle on outboard wall on STBD side of Galley. 46CFR120.200(b) & (c)
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 6 October 2011
Resolved 6 October 2011
Resolution: Company installed new cover on 120 volt receptacle on the STBD side of galley.
Engineering › Diesel Engine (propulsion-reduction gear) › Piping (exhaust)
Issued 6 September 2011 Resolved
Repair 2" crack on exhaust piping for STBD main diesel engine. Crack is located along upper support bracket weld on the exhaust muffler. After repair, engine must be test ran in presence of Coast Guard Marine Inspector to verify that exhaust is no longer leaking from the piping. 46CFR119.430(b)
Condition: Damaged By Earlier Event
Action required: 701 - Prior to carriage of passengers/cargo
Due 6 October 2011
Resolved 7 September 2011
Resolution: Company hired welder to repair exhaust cracks. [name withheld] attended vessel to witness/inspect repairs on the 7th of September. All sat.
Documentation › Markings/Placards › Warning Signs
Issued 6 September 2011 Resolved
Mark/post placards to identify all escape hatches onboard, IAW 46CFR122.606
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 6 October 2011
Resolved 6 October 2011
Resolution: Company posted placards to identify engine room escape hatches that open into the passenger area.
Engineering › Bilge Water Management System › Interface Detector
Issued 6 September 2011 Resolved
High level bilge alarm panel is not functioning properly. Visual indicators for several zones illuminate after testing several of the floats in different zones. Outstanding CG-835 issued by [name withheld] is still active. 46CFR119.530
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 6 October 2011
Resolved 6 October 2011
Resolution: Company demonstrated working knowledge of bilge alarm system. Because bilge alarm system is integrated into the intrusion alarm system, when a bilge alarm is activated the alarm zone is stored into the systems memory until the system memory is cleared.
Lifesaving › Hand Flares › Quantity
Issued 6 September 2011 Resolved
Ensure required amount of flares are on board prior to sailing
Action required: 705 - Other - as specified
Due 8 September 2011
Resolved 8 September 2011
Resolution: Vessell Rep purchased new Flares that day.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 6 September 2011 Resolved
Provide up to date first aid kit and show equipment list
Action required: 705 - Other - as specified
Due 10 October 2011
Resolved 6 October 2011
Resolution: Company updated expired items in first aid kit and provided first aid equipment listed as requested.
Electrical › Lighting (emergency) › Battery Operated Lantern
Issued 6 September 2011 Resolved
Install new light bulbs and ensure all E lighting is functioning properly
Action required: 705 - Other - as specified
Due 6 October 2011
Resolved 6 October 2011
Resolution: Tested all emergency lighting throughout the vessel. All sat.
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 6 September 2011 Resolved
ensure all lights function properly.
Action required: 705 - Other - as specified
Due 6 October 2011
Resolved 6 October 2011
Resolution: Tested operation of float lights for all life-floats. All sat.
Accommodation/Occupational Safety › Other Accommodation Spaces › Recreation Space
Issued 6 September 2011 Resolved
Start and maintain an elevator maintenance program IAW manufacturers guidance
Action required: 705 - Other - as specified
Due 6 October 2011
Resolved 6 October 2011
Resolution: Company provided proof of elevator maintenance program as required.
Navigation › Piloting/Steering › Inland Navigation Rules
Issued 6 September 2011 Resolved
Provide new navigation books and charts for AOR
Action required: 705 - Other - as specified
Due 6 October 2011
Resolved 6 October 2011
Resolution: Company placed new navigation books and charts for their AOR in the pilot house.
Construction/Loadline › Hull › Side Shell
Issued 20 December 2010 Resolved
Starboard bow damaged by storm after contacting dock. Required repair at dry dock prior to 2011 boating season.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 31 May 2011
Resolved 8 April 2011
Resolution: Repair complete.
Fire Fighting › Fire Pumps › Pressure
Issued 12 May 2008 Resolved
Install pressure guage on discharge side of firepump.
Action required: 705 - Other - as specified
Due 12 June 2008
Resolved 28 August 2008
Resolution: Fire pump pressure gauge installed and properly operated.
Fire Fighting › Structural - A Class Divisions › Fire Doors
Issued 12 May 2008 Resolved
Provide proposal to account for closure of 3rd deck stairtower door (#12) and remove locking handle iaw evacuation plan.
Action required: 705 - Other - as specified
Due 12 June 2008
Resolved 6 June 2008
Fire Fighting › Means of Escape › Escape Route Signs
Issued 12 May 2008 Resolved
Correct evacuation plan to be iaw vessel stability letter- NMT 200 persons on 4th deck.
Action required: 705 - Other - as specified
Due 12 June 2008
Resolved 6 June 2008
Fire Fighting › Structural - A Class Divisions › Control Stations
Issued 8 June 2007 Resolved
Properly seal electrical wire run in the pilothouse deck to comply with A-60 per 46 CFR 116.415
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 23 July 2007
Resolved 27 July 2007
Engineering › Reduction Gearing/Clutches › Shrink-Fit Rings
Issued 8 June 2007 Resolved
Install Nylock nuts on Morse control cable anchors at the Marine Gear Per 46 CFR 119.200
Condition: Design Flaw
Action required: 705 - Other - as specified
Due 23 July 2007
Resolved 27 July 2007
Electrical › Electrical Distribution System (service) › Outlet Box
Issued 8 June 2007 Resolved
Renew GFI recepticle at the swim plateform per 46 CFR 120.370
Action required: 705 - Other - as specified
Due 23 July 2007
Resolved 27 July 2007
Communications › Public Address System › Loudspeaker
Issued 8 June 2007 Resolved
Install additional PA speakers throughout the vessel to comply with 46 CFR 121.610,
Condition: Design Flaw
Action required: 705 - Other - as specified
Due 23 July 2007
Resolved 27 July 2007
Lifesaving › Buoyant Apparatus › Lifeline
Issued 8 June 2007 Resolved
Provide new waterlight lines for al 10 Bouyant Apparatusper 46 CFR 117.70
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 23 July 2007
Resolved 27 July 2007
Operations/Management › Drills/Instruction › Flooding Mitigation
Issued 8 June 2007 Resolved
Post bilge system line diagram at the bilge manifold IAW 46 CFR 115.830
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 23 July 2007
Resolved 27 July 2007
Lifesaving › Lifejacket/PFD (General) › Condition
Issued 8 June 2007 Resolved
Provide safe means to attach man overboard rescue personnel IAW46 CFR 115.830
Action required: 705 - Other - as specified
Due 23 July 2007
Resolved 27 July 2007
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 8 June 2007 Resolved
Update all expired First Aid gear Per 46 CFR 121.710.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 23 July 2007
Resolved 27 July 2007
Electrical › Electric Supply System (service) › Battery Charger
Issued 4 January 2007 Resolved
Battery to the bow thruster died causing the bow thruster to become inoperable.
Condition: Unknown
Action required: 705 - Other - as specified
Due 4 February 2007
Resolved 22 January 2007
Resolution: Bow thruster battery replaced. Witnessed proper operation of bow thruster.
Engineering › Diesel Engine (propulsion-reduction gear) › Gear/Clutch Starter (electric)
Issued 4 January 2007 Resolved
While attempting to scavenge a battery from the stbd generator, power was lost to the bridge propulsion controls. Battery was reconnected and control was restored. Vessel must prove proper operation of emergency power to the propulsion system controls as per 46 CFR 120.310. In addition, sea trials are to be conducted to the satisfaction of the attending Marine Inspector.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 4 February 2007
Resolved 22 January 2007
Resolution: Witnessed proper operation of steering system with primary and emergency power.
Fire Fighting › Structural - A Class Divisions › Fire Doors
Issued 24 April 2006 Resolved
Properly repair fire screen doors to be self closing, found four fire doors that remained open, in accordance with 46 CFR 116.435.
Action required: 705 - Other - as specified
Due 1 May 2006
Resolved 26 April 2006
Resolution: Fire Screen Door Hinges were tightend and all close properly.
Fire Fighting › Means of Escape › Blocked
Issued 24 April 2006 Resolved
Properly label and ensure operation of emergency escape hatch from crews lounge in accordance with 46 CFR 116.500.
Action required: 705 - Other - as specified
Due 24 May 2006
Resolved 26 April 2006
Resolution: New Label has been placed on the escape hatch.
Electrical › Electrical Distribution System (service) › Wiring
Issued 24 April 2006 Resolved
Properly terminate dead end wire in a junction box or remove dead end wire from main deck aft compartment in accordance with 46 CFR 120.340.
Action required: 705 - Other - as specified
Due 24 May 2006
Resolved 26 April 2006
Resolution: Junction boxes have been installed, all wires are now terminated in Junction boxes.
Operations/Management › Drills/Instruction › Safety Orientation
Issued 24 April 2006 Resolved
Properly implement passenger count method to have a record of passengers on board on the shore side in accordance with 46 CFR 122.504.
Action required: 705 - Other - as specified
Due 24 May 2006
Resolved 26 April 2006
Resolution: crew and passenger list is now faxed to company head quarters each time before vessel leaves the dock.
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 24 April 2006 Resolved
Properly repair water light on lifebuoy in accordance with 46 CFR 117.175 (d).
Action required: 705 - Other - as specified
Due 1 May 2006
Resolved 26 April 2006
Resolution: New battery was installed in light. Light is properly working.
Fire Fighting › Fixed CO2 Fire Extinguishing System › Automatic Heat Detectors
Issued 14 March 2006 Resolved
Ensure proper operation of the heat risers on the fixed CO2 System in the Engineroom.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 20 March 2006
Resolution: Vessel proved proper operation of both heat risers on the fixed CO2 system.
Stability › Incline Test › General
Issued 3 June 2005 Resolved
Vessel limited to 3nm until tonnage and SFP issues are resolved.
Action required: 705 - Other - as specified
Resolved 28 March 2006
Resolution: Recieved letter from MSC ref. Ser. H2-0504587 stating that because there was only a aggregate weight change of 1.7% that neither a deadweight survey of the vessel, nor revised loading conditions/stability calculations, are necessary at time.
Lifesaving › Inflatable Liferafts › Not on Board
Issued 28 April 2005 Resolved
Provide on board a SOLAS "A" or "B" pack liferaft for 100% persons onboard. Prior to departure of the vessel from Boston, MA.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Resolved 15 December 2005
Resolution: Vessel is operating in CHIMS Zone
Lifesaving › Immersion Suits › Serviceable
Issued 28 April 2005 Resolved
Prior to departure from the port of Boston, MA, provide onboard a USCG approved Personal Floatation Device light for each exposure suit onboard.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 15 December 2005
Resolution: Vessel is operating in CHIMS zone
Stability › Intact Righting Energy › General
Issued 28 April 2005 Resolved
Provide calculations to the Coast Guard Marine Safety Center on the weights added / removed / relocated and their effect on the vessel's lightship data.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 18 May 2005
Resolution: No deadweight survey or incline test required per MSC comment letter 16710/P011031, Ser H2-0504587 dtd 05/18/2005.
Construction/Loadline › Hull › Hull Plating
Issued 28 April 2005 Resolved
Provide approved drawings reviewed by the USCG Marine Safety Center for the modifications to the vessel.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 15 December 2005
Resolution: Verified that Approved plans are in Vessel file.
Fire Fighting › Fire Pumps › Bearings
Issued 22 June 2004 Resolved
Prove proper operation of the main fire pump prior to carrying passenger but NLT 30JUN04 to the satisfaction of the attending Marine Inspector.
Condition: Improper Installation
Due 30 June 2004
Resolved 29 June 2004
Resolution: Cleared on board by [name withheld].
Lifesaving › Hand Flares › Expired
Issued 22 June 2004 Resolved
Provide 3 red hand held flares prior to carrying passenger but NLT 30JUN04 to the satisfaction of the attending Marine Inspector.
Condition: Improper/Lack of Maintenance
Due 30 June 2004
Resolved 29 June 2004
Resolution: Cleared on board by [name withheld] 6/29/04.
Communications › Radio Communications › EPIRB
Issued 22 June 2004 Resolved
Provide new hydrostatic release for the EPRIB prior to carrying passenger but NLT 30JUN04 to the satisfaction of the attending Marine Inspector.
Condition: Improper/Lack of Maintenance
Due 30 June 2004
Resolved 29 June 2004
Resolution: Cleared on board by [name withheld] 6/29/04.
Operations/Management › Passenger Operations › Safety Orientation
Issued 22 June 2004 Resolved
Provide means to leave passenger count ashore NLT 30JUN04
Condition: Unknown
Due 30 June 2004
Resolved 29 June 2004
Resolution: Cleared on board by [name withheld] 6/29/04.
Documentation › Logs/Records › Logbook (official)
Issued 22 June 2004 Resolved
Provide up-to-date training log to include training and drills conducted and members attending NLT 30JUN04
Due 30 June 2004
Resolved 29 June 2004
Resolution: Cleared on board by [name withheld]
Engineering › Steering Gear System › Fastener
Issued 22 June 2004 Resolved
Rudder bolts and nuts not properly installed, make permanent and proper repairs to the satisfaction of the attending Marine Inspector NLT 30JUN04
Due 30 June 2004
Resolved 29 June 2004
Resolution: Cleared on board by [name withheld]
Documentation › Logs/Records › Drug Test Records
Issued 22 June 2004 Resolved
Provide copy of the Drug and Alcohol Testing Date MIS Form, once proper filled out and faxed to CG Headquarters .NLT 30JUN04
Due 30 June 2004
Resolved 29 June 2004
Resolution: Cleared on board by [name withheld]
Documentation › Logs/Records › Drug Test Records
Issued 22 June 2004 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Due 30 June 2004
Resolved 30 June 2004
Resolution: Cleared on board by CWOMonyhan
Engineering › Bilge Water Management System › Piping
Issued 25 May 2004 Resolved
Prove bilge de-watering system in all spaces served.
Action required: 705 - Other - as specified
Due 26 June 2004
Resolved 24 June 2004
Engineering › Diesel Engine (auxiliary) › Waste Heat Recovery
Issued 25 May 2004 Resolved
Renew the seawater intake hose on the generators and bow thruster.
Action required: 705 - Other - as specified
Due 26 June 2004
Resolved 24 June 2004
Fire Fighting › Combustible Materials
Issued 21 July 2003 Resolved
Remove all carpet from behind bar areas on decks 3 and 4. LEGACY COMPONENT DESC: Primary Deck Coverings
Condition: Improper Installation
Due 3 August 2003
Resolved 8 August 2003
Resolution: Carpet allowed, high risk space.
Lifesaving › Lifejacket/PFD (General) › Storage
Issued 21 July 2003 Resolved
Mount life jacket donning placards immediately adjacent to life jackets. LEGACY COMPONENT DESC: Life Jacket Placards
Condition: Improper Installation
Due 3 August 2003
Resolved 23 June 2004
Resolution: Cleared at Annual, CHK
Navigation › Piloting/Steering › Marine Charts
Issued 21 July 2003 Resolved
Provide updated navigation pubs and charts. LEGACY COMPONENT DESC: Navigation charts and Publications
Condition: Placed in Improper Service
Due 3 August 2003
Resolved 23 June 2004
Resolution: Cleared at Annual, CHK
Fire Fighting › Combustible Materials › Paints/Varnishes/Other Finishes
Issued 21 July 2003 Resolved
Remove and properly store all flammable liquids on bridge. LEGACY COMPONENT DESC: Storage
Condition: Improper Installation
Due 22 July 2003
Resolved 23 June 2004
Resolution: Cleared at Annual, CHK
Accommodation/Occupational Safety › Cooking Systems › LPG System Requirements
Issued 21 July 2003 Resolved
Remove portable grills or make grills meet ABYC, A-1 regulations or NFPA 302, Chp 6, when passengers embarked.
Condition: Improper Installation
Due 3 August 2003
Resolved 23 June 2004
Resolution: Cleared at Annual, CHK
Engineering › Steering Gear System › Hydraulic Hose
Issued 21 July 2003 Resolved
Renew hydraulic hode on steering ram starboard side.
Condition: Improper/Lack of Maintenance
Due 3 August 2003
Resolved 23 June 2004
Resolution: Cleared at Annual, CHK
Engineering › Fuel Oil Service System › Vent Pipe
Issued 21 July 2003 Resolved
Renew flame screen on port side fuel vent.
Due 3 August 2003
Resolved 23 June 2004
Resolution: Cleared at Annual, CHK
Fire Fighting › Structural - A Class Divisions › Doors
Issued 21 July 2003 Resolved
Remove door stops on all lower cabin doors.
Due 3 August 2003
Resolved 23 June 2004
Resolution: Cleared at Annual, CHK
Fire Fighting › Emergency Fire Pumps › Power Source
Issued 21 July 2003 Resolved
Prove proper operation of remote start for fire pump.
Action required: 701 - Prior to carriage of passengers/cargo
Due 22 July 2003
Resolved 21 October 2015
Resolution: Cleared at Annual, CHK
Electrical › Electrical Distribution System (service) › Ground Detection
Issued 21 July 2003 Resolved
Locate and correct or repair ground fault on electrical panel.
Due 3 August 2003
Resolved 23 June 2004
Resolution: Cleared at Annual, CHK
Communications › Alarms/Indicators › Steering Failure Alarm System
Issued 21 July 2003 Resolved
Provide alarm for steering motor failure.
Condition: Placed in Improper Service
Due 3 August 2003
Resolved 23 June 2004
Resolution: Cleared at Annual, CHK

Casualty record · 4

3 January 2007Routine · role: Involved in a Marine Casualty · activity 2852375
2 March 2016Routine · role: Involved in a Marine Casualty · activity 5839060
31 August 2025Routine · role: Involved in a Marine Casualty · activity 8307103
4 October 2025Routine · role: Involved in a Marine Casualty · activity 8308575
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Recorded names · 2

KANAN (2007), AQUA AZUL (2016). Names as the Coast Guard recorded them in incident records, with the years they appear; some are renames and some are spelling variants.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.