Records from 1984 to 2026. Most recent: inspection, 19 May 2026.
Inspection history · 127
19 May 2026
Administrative Inspection
Administrative · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 8376352
31 October 2025
Deficiency Check · Administrative Inspection
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 8276135
24 March 2025
Re-Inspection · ACP Drydock Oversight · ACP COI Oversight
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 8111993
12 March 2025
Type not recorded
No type recorded · Sector North Carolina · USCG East District (CGD-E) · Activity 8095182
7 March 2025
Permit to Proceed
Administrative · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 8090099
13 February 2025
Deficiency Check
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 8079431
23 January 2025
MTSA/ISPS Verification
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 8070236
4 December 2024
Administrative Inspection
Administrative · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 8043194
26 June 2024
Deficiency Check
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 7943177
26 June 2024
Type not recorded
No type recorded · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 7946482
2 November 2023
Deficiency Check · MTSA/ISPS Verification · ACP Annual Oversight · Annual Inspection
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 7806552
15 September 2023
Damage Survey · Administrative Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7792392
15 September 2023
Type not recorded
No type recorded · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7800761
11 September 2023
MTSA/ISPS Verification · Administrative Inspection
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 7789472
27 June 2023
Administrative Inspection · In-Service Inspection
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 7725136
16 November 2022
Deficiency Check · Periodic Inspection · Administrative Inspection · ACP Periodic Oversight
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 7590617
9 August 2022
Deficiency Check · ACP Additional Oversight – Risk Assessment
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 7524643
16 May 2022
Deficiency Check
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 7450143
30 November 2021
Annual Inspection · ACP Annual Oversight · Deficiency Check
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 7356099
11 October 2021
Type not recorded
No type recorded · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 7346176
27 August 2021
Deficiency Check · Damage Survey
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 7300623
22 June 2021
Type not recorded
No type recorded · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 7238530
5 April 2021
Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7169148
24 November 2020
Deficiency Check · MTSA/ISPS Verification · ACP Annual Oversight · Annual Inspection
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 7101194
27 July 2020
Administrative Inspection · Deficiency Check
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 7017745
24 June 2020
Administrative Inspection · In-Service Inspection
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 6985779
19 June 2020
Type not recorded
No type recorded · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 6991824
5 December 2019
ACP Additional Oversight – Risk Assessment · MTSA/ISPS Verification · Administrative Inspection
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 6846304
5 December 2019
Administrative Inspection
Administrative · Commandant (CG-5P-TI) · Activity 6883453
1 November 2019
Deficiency Check
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 6847186
27 August 2019
ACP Additional Oversight – Risk Assessment · In-Service Inspection · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6815787
9 July 2019
Administrative Inspection · ACP Annual Oversight · Deficiency Check · MTSA/ISPS Verification · Examination of Repairs · Annual Inspection
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 6742430
17 June 2019
Administrative Inspection
Administrative · Commandant (CG-5P-TI) · Activity 6716986
23 March 2019
Deficiency Check · In-Service Inspection
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 6647771
1 February 2019
Administrative Inspection · Deficiency Check
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 6618875
6 December 2018
In-Service Inspection · MTSA/ISPS Verification · Administrative Inspection · ACP Additional Oversight – Risk Assessment
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 6585014
4 December 2018
ACP Additional Oversight – Risk Assessment
Administrative · Commandant (CG-5P-TI) · Activity 6591855
28 September 2018
Deficiency Check
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 6551272
26 July 2018
Deficiency Check
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 6519592
19 June 2018
COI Inspection · Re-Inspection · ACP COI Oversight
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 6443621
18 June 2018
Administrative Inspection
Administrative · Commandant (CG-5P-TI) · Activity 6447771
19 March 2018
Administrative Inspection · MTSA/ISPS Verification · Annual Inspection · In-Service Inspection · Deficiency Check · ACP Annual Oversight
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 6375045
19 March 2018
Administrative Inspection
Administrative · Commandant (CG-5P-TI) · Activity 6381098
5 March 2018
Type not recorded
No type recorded · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 6380789
20 February 2018
Administrative Inspection
Administrative · Navigation Center · Activity 6357800
12 April 2017
MTSA Verification · Annual Inspection · ACP Annual Oversight
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 6117148
23 December 2016
Administrative Inspection
Administrative · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 6061874
27 April 2016
ACP Annual Oversight · MTSA/ISPS Verification
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 5856771
27 August 2015
Deficiency Check
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 5228194
11 March 2014
Examination of Repairs
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 4814197
7 March 2014
Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 4979698
13 September 2011
Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 4144235
13 July 2011
ACP Annual Oversight
Administrative · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 4080085
25 January 2010
Damage Survey
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3669656
24 January 2010
Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3669211
9 December 2009
Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3647386
18 February 2009
ACP Annual Oversight
Administrative · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3419788
30 January 2009
Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3402833
23 December 2008
Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3384503
28 September 2007
ACP Annual Oversight
Administrative · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3071565
13 September 2006
Administrative Inspection
Administrative · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 2777373
23 August 2006
Deficiency Check
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 2757199
18 August 2006
In-Service Inspection
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 2752435
4 November 2005
Security Plan Amendment Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2528362
5 May 2005
MTSA/ISPS Verification · COI Inspection
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 2349710
13 October 2004
Deficiency Check
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 2220037
26 July 2004
Security Plan Amendment Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2145434
6 July 2004
COI Inspection · Hull Examination · Internal Structural Exam
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 2123202
3 June 2004
MTSA/ISPS Verification
Physical examination · Commandant (CG-CVC) · Activity 2087516
28 January 2004
Security Plan Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 1995717
21 October 2003
Re-Inspection
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1932829
28 May 2003
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1923994
24 January 2003
Security Inspection · Administrative Inspection
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1742949
23 January 2003
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1742499
30 May 2002
Re-Inspection
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1623368
8 March 2002
Examination of Repairs · In-Service Inspection
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1492551
25 July 2001
Re-Inspection
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1412289
8 January 2001
Administrative
Administrative · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 825317
9 May 2000
COI Inspection
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1410330
17 March 2000
Damage Survey
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1376080
24 September 1999
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1033820
10 August 1999
Examination of Repairs · Hull Examination
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1454704
15 June 1999
Re-Inspection
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1415172
3 September 1998
Deficiency Check
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1132147
5 May 1998
MARPOL Annex V Examination · COI Inspection
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1462651
30 May 1997
MARPOL Annex V Examination · Re-Inspection
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1364168
19 March 1997
Deficiency Check
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1456459
9 December 1996
Deficiency Check
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1089210
9 September 1996
Administrative
Administrative · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1261541
17 May 1996
COI Inspection · Deficiency Check
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1411309
18 July 1995
Re-Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1457289
6 February 1995
Deficiency Check
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1145162
25 September 1994
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 229412
10 August 1994
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 674149
27 July 1994
COI Inspection · Reflagging & Initial Certification · Hull Examination
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 870571
25 July 1994
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 184905
2 February 1993
Type not recorded
No type recorded · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 448743
26 January 1993
Uninspected Other
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 831563
20 January 1993
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 181886
13 January 1993
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 26774
24 June 1992
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 351594
19 October 1990
Type not recorded
No type recorded · COTP NEW YORK · USCG Northeast District (CGD-NE) · Activity 493848
25 August 1990
Type not recorded
No type recorded · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 339022
25 August 1990
Type not recorded
No type recorded · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 1224516
6 July 1989
Administrative
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1039144
24 March 1989
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1045063
10 January 1989
Deficiency Check
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1352672
5 December 1988
Type not recorded
No type recorded · MSO WILMINGTON · USCG East District (CGD-E) · Activity 1207591
2 December 1988
Type not recorded
No type recorded · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 902091
10 October 1988
Type not recorded
No type recorded · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 894397
12 September 1988
Re-Inspection
Physical examination · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 1351919
6 September 1988
Type not recorded
No type recorded · COTP NEW YORK · USCG Northeast District (CGD-NE) · Activity 467899
17 March 1988
Hull Examination
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1347266
18 January 1988
Type not recorded
No type recorded · MSO WILMINGTON · USCG East District (CGD-E) · Activity 540698
17 January 1988
Deficiency Check
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 1011997
13 January 1988
Damage Survey
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1323124
21 August 1987
Type not recorded
No type recorded · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 459783
19 August 1987
Deficiency Check
Physical examination · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 1313056
15 August 1987
COI Inspection · Drydock Extension
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1002228
7 November 1985
Damage Survey
Physical examination · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 994255
29 October 1985
Type not recorded
No type recorded · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 1302629
12 September 1985
Type not recorded
No type recorded · MSO WILMINGTON · USCG East District (CGD-E) · Activity 519640
11 May 1985
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1288227
17 March 1985
Type not recorded
No type recorded · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 981990
17 March 1985
Type not recorded
No type recorded · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 1289030
16 October 1984
Type not recorded
No type recorded · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 975065
14 May 1984
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1281746
09 - Working and Living Conditions › 091 - Living Conditions › Other (crew and accommodation)
Issued 7 August 2025
Resolved
A vessel engaged in commercial service that does not carry passengers shall maintain a video surveillance system. Sureveillance and recording system required by the 2023 NDAA was not installed by the published deadline. 46 USC 4901(a)
Action required: 705 - Other - as specified
Due 31 October 2025
Resolved 31 October 2025
Resolution: Verified cameras were installed and working properly.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 26 June 2024
Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or persons on board. While transiting outbound Port of Beaumont, vessel lost both generators and was unable to keep cooling temps down to an acceptable level. Vessel anchored at the anchorage to determine cause. Vessel to determine cause of failure and corrective action to the satisfaction of the attending marine inspector.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 29 July 2024
11 - Life Saving Appliances › N/A - No Subsystem › Lifeboats
Issued 26 June 2024
Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or persons on board. While lowering the lifeboats noted the remote control wire had excessive slack, during recover of lifeboats noted the remote control wire was not laying on the drum uniformly. Vessel to submit a technician report to the satisfaction of the attending marine inspector.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 13 February 2025
Resolution: Received Statement of Conformity from Breakwater International.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 2 November 2023
Resolved
Where the cables are neither sheathed nor armoured and there might be a risk of fire in the event of an electrical fault, precautions shall be required by the Administration.
Loose exposed wires were hanging from the bridge overhead STBD side over the radar.
74 SOLAS Chp.II-1/Reg.27.a.iv.2
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 17 November 2023
Resolution: Cleared with class, vessel sent CG supporting documents.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 2 November 2023
Resolved
Where the cables are neither sheathed nor armoured and there might be a risk of fire in the event of an electrical fault, precautions shall be required by the Administration.
Forward main hold center line overhead, appears a wire reel has been wired into a junction box providing power. The end of the wire reel does not have an connection.
74 SOLAS Chp.II-1/Reg.27.a.iv.2
Condition: Placed in Improper Service
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 17 November 2023
Resolution: Cleared with class, vessel sent CG supporting documents.
09 - Working and Living Conditions › 091 - Living Conditions › Water, pipes, tanks
Issued 2 November 2023
Resolved
The hull, machinery and equipment ...of a cargo ship shall be surveyed on completion and thereafter in such manner to ensure that their condition is in all respects satisfactory.
Hot water line in the port side fidley leaking at the flange on to equipment below.
74 SOLAS Chp.I/Reg.11
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 17 November 2023
Resolution: Cleared with class, vessel sent CG supporting documents.
04 - Emergency Systems › N/A - No Subsystem › Muster list
Issued 2 November 2023
Resolved
In cargo ships a muster of the crew for boat drills and fire drills shall take place at intervals of not more than one month, provided that a muster of the crew for boat drill and fire drill shall take place within 24 hours of leaving port if more than 25 percent of the crew have been replaced.
Crew must demonstrate satisfactory fire and abandon ship/muster prior to departure.
74 SOLAS Chp.III/Reg.26.a.ii
Condition: Invalid
Action required: 17 - Rectify deficiencies prior to departure
Resolved 26 June 2024
14 - Pollution Prevention › 141 - MARPOL Annex I › Segregation of oil and water ballast
Issued 30 November 2022
Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present Convention to ensure that the ship in all respects will remain fit to proceed to sea without presenting an unreasonable threat of harm to the marine environment. Vessel could not demonstrate proper operation of system.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 December 2022
Resolved 13 February 2023
05 - Radio Communications › N/A - No Subsystem › Operation/maintenance
Issued 30 November 2022
Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or persons on board. Vessel's display radar screens FAR
2827 and 2837 are leaking fluid. Though functionality of radars do not appear affected, technician on board recommends replacing both monitors. Due to shortages, monitors are on back order. Vessel to submit repair proposal and timeline to the satisfaction of Class.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 December 2022
Resolved 13 February 2023
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 30 November 2022
Resolved
All principles relating to the arrangement of navigation
equipment shall be taken with the aim of minimizing the
risk of human error. Vessel's navigational light panel shows lights on when switch is in the off position and lights off when switch is in the on position.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 13 February 2023
11 - Life Saving Appliances › N/A - No Subsystem › Lifeboat inventory
Issued 30 November 2022
Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or persons on board. The aspirin in both the port and starboard side lifeboats are expired.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 13 February 2023
07 - Fire Safety › N/A - No Subsystem › Fire prevention structural integrity
Issued 30 November 2022
Resolved
Structural fire protection, including fire-resisting divisions, and protection of openings and penetrations in these divisions shall be kept in good order so as to ensure their required performance if a fire occurs. Vessel's EZ Path electrical penetration on the bridge is stuffed with putty. Vessel to remove putty or provide specs/type approval of putty to the satisfaction of Class.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 December 2022
Resolved 13 February 2023
09 - Working and Living Conditions › 092 - Working Conditions › Machinery
Issued 9 August 2022
Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or persons on board. A satisfactory pumping plant is to be provided. Bilge/ballast pump in fire main was leaking generously while primary fire pump was running.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 9 September 2022
Resolved 29 August 2022
09 - Working and Living Conditions › 092 - Working Conditions › Safe means of access
Issued 9 August 2022
Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or persons on board. Safety rail outside of ECR in the engine room is deteriorated.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 9 September 2022
Resolved 29 August 2022
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 9 August 2022
Resolved
Emergency lighting shall be in the main machinery space and the power shall be adequate for a period of 6 hours. Vessel has two emergency lights out in the aft engine room.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 9 September 2022
Resolved 29 August 2022
11 - Life Saving Appliances › N/A - No Subsystem › Lifeboats
Issued 9 August 2022
Resolved
Before the ship leaves port and at all times during the voyage, all life-saving appliances shall be in working order and ready for immediate use. Vessel's open lifeboat is showing signs of deterioration. The backing plate by the lifeboats releasing gear is pulling away from the fiberglass.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 9 September 2022
Resolved 29 August 2022
02 - Structural Conditions › N/A - No Subsystem › Hull - corrosion
Issued 30 November 2021
Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or persons on board. Vessel's starboard stack is wasted with a 1.5 inch hole on the exterior.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 13 May 2022
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 30 November 2021
Resolved
All the life-saving appliances shall be kept in working order and available for immediate use before the ship leaves port and at all times during the voyage. Various ring buoy battery lights were expired. Vessel to check all batteries and replace as necessary.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 1 December 2021
05 - Radio Communications › N/A - No Subsystem › Other (radio communication)
Issued 30 November 2021
Resolved
Each vessel must carry a certificate with a valid endorsement while subject to the Bridge-to-Bridge Act. Vessel could not produce a valid Bridge-to-Bridge Certificate.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 1 December 2021
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 30 November 2021
Resolved
Doors other than watertight doors, in stairway enclosures, shall be of the self-closing type, as required for the main vertical zone bulkheads, in accordance with Regulations 38 of this Chapter. Door at the top of the stair tower leading to Bridge, has a hold back and is not self closing.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 3 December 2021
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 30 November 2021
Resolved
Before the ship leaves port and at all times during the voyage, all life-saving appliances shall be in working order and ready for immediate use. When in ROS status, vessel has minimum crew and maneuverability. Prior to activation, vessel must conduct fire and abandon ship drills, lower both lifeboats to the water, and put all safety gear at location to the satisfaction of the attending Marine Inspector.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 16 May 2022
11 - Life Saving Appliances › N/A - No Subsystem › Lifeboats
Issued 24 November 2020
Resolved
A mechanically propelled lifeboat, other than a motor lifeboat, shall comply with the following conditions: The propelling gear shall be of an approved type and shall have sufficient power to enable the lifeboat to be readily cleared from the ships side when launched. Vessel's STBD lifeboat Flemming gear binds in the ahead position, severely restricting the ahead propulsion of the lifeboat. 60SOLAS III/10(a)
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 24 November 2020
Resolved 4 February 2021
Resolution: Vessel effected repairs to the flemming gear to the satisfaction of the attending class surveyor [name withheld] work order 4464670.
11 - Life Saving Appliances › N/A - No Subsystem › Inflatable liferafts
Issued 24 November 2020
Resolved
Each liferaft or group of liferafts shall be stowed with a float free arrangement complying with the requirements of paragraph 4.1.6 of the Code so that each floats free and, if inflatable, inflates automatically when the ship sinks. All three of the vessel's 12 person liferafts' painter lines were found tied to the liferaft cradle instead of the hydrostatic release unit's weak link. As a result the liferafts would not float free of the ship as required. 74SOLAS(2014 cons ed)
III/13.4.2
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Due 24 November 2020
Resolved 4 February 2021
Resolution: Liferaft painters were reattached as designed to the weak link to the satisfaction of the attending class surveyor [name withheld] work order 4464670.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 24 November 2020
Resolved
Lifebuoys shall always be capable of being rapidly cast loose and shall not be permanently secured in any way. Port bridge wing lifebuoy found tied off to the bridge, rendering it not capable of rapid deployment.60SOLAS III/21(h)
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Due 24 November 2020
Resolved 4 February 2021
Resolution: Vessel secured port bridge lifebuoy properly, to the satisfaction of the attending class surveyor [name withheld] work order 4464670.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 24 November 2020
Resolved
At least two lifebuoys provided with self-igniting lights in accordance with paragraph (e) of this regulation shall also be provided with an efficient self-activating smoke signal capable of producing smoke of a highly visible color for at least 15 minutes and shall be capable of quick release from the navigating bridge. Port bridge wing lifering found missing it's self-igniting light. 60SOLAS III/21(g)
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Due 24 November 2020
Resolved 4 February 2021
Resolution: Vessel purchased the required self igniting light and installed to the satisfaction of the attending class surveyor [name withheld] work order 4464670.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 24 November 2020
Resolved
At least two lifebuoys provided with self-igniting lights in accordance with paragraph (e) of this regulation shall also be provided with an efficient self-activating smoke signal capable of producing smoke of a highly visible color for at least 15 minutes and shall be capable of quick release from the navigating bridge. Bridge wing liferings found without their smoke cannisters tied to the rings, rendering them unable to be capable of quick release as required. 60SOLAS III/21(g)
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Due 24 November 2020
Resolved 4 February 2021
Resolution: Vessel properly secured the smoke canisters to the lifebuoys to the satisfaction of the attending class surveyor [name withheld] work order 4464670.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 24 November 2020
Resolved
Lifebuoys shall be marked in block letters with the name and port of registry of the ship in which it is carried. Vessels port aft lifering's markings have worn off, rendering the vessel name and port of registry unreadable. 60SOLAS III/21(a)(v)
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 4 February 2021
Resolution: Vessel's crew re-stenciled the vessel's name and port of registry on all lifebuoys to the satisfaction of the attending class surveyor [name withheld] work order 4464670.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 24 November 2020
Resolved
Vessels of 50 meters or more in length must be visible at the following minimum ranges: A masthead light, 6 miles, A sternlight, 3 miles, A towing light, 3 miles, A white, red, green or yellow all around light, 3 miles. Vessel's masthead and anchor lights did not light when energized. 33CFR83.22(a)
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 24 November 2020
Resolved 4 February 2021
Resolution: Vessel installed new labels on Navigation Light Panel, tested to the satisfaction of the attending class surveyor [name withheld] work order 4464670.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 24 November 2020
Resolved
Devices liable to arc shall not be installed in any compartment assigned principally to accumulator batteries unless the devices are flameproof (explosion proof). Wiring to batteries in the emergency battery room has been spliced. The splice is not enclosed in an explosion proof container, creating a risk of explosion. 60SOLAS II/27(c)
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 4 February 2021
Resolution: Vessels electrician removed incorrectly spliced cable to the satisfaction of the attending class surveyor [name withheld] work order 4464670.
11 - Life Saving Appliances › N/A - No Subsystem › On board training and instructions
Issued 24 November 2020
Resolved
On board training in the use of the ship's life-saving appliances, including survival craft equipment, and in the use of the ship's fire-extinguishing appliances shall be given as soon as possible but not later than two weeks after a crew member joins the ship. Vessels crew members were observed to be unfamiliar with the operation of critical lifesaving appliances including lifeboat propulsion, launching and liferaft stowage arrangement. Additionally, vessel was unable to produce training records for newly arrived crew members. 74 SOLAS (2014 cons)
III/19.4.1
Action required: 17 - Rectify deficiencies prior to departure
Due 24 November 2020
Resolved 4 February 2021
Resolution: Drill frequency and training spot checked by attending class surveyor, Drills and additional training to be conducted prior to the vessel's next activation. See ABS work order 4464670.
07 - Fire Safety › N/A - No Subsystem › Fire prevention structural integrity
Issued 24 November 2020
Resolved
Fire doors in main vertical zone bulkheads other than watertight doors shall be of the self-closing type with simple and easy means of release from the open position. Engine Control Room door into the machinery space does not latch in the closed position. 60SOLAS II/38(e)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 10 February 2021
Resolution: Vessel's engineering department repaired the existing Engine Control Room door latch and striker plate to the satisfaction of the attending class surveyor [name withheld] work order 4464670.
04 - Emergency Systems › N/A - No Subsystem › Emergency source of power - Emergency generator
Issued 24 June 2020
Resolved
While performing a high jacket water shut down of EDG and with the aux. automation panel in manual control, the emergency bus panel breaker closed by itself, and in the process the engine had over-sped becoming unresponsive to the normal commands of shut down.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 27 July 2020
Resolution: Deficiency rectified to the satisfaction of the attending Class Surveyor.
04 - Emergency Systems › N/A - No Subsystem › Emergency source of power - Emergency generator
Issued 5 December 2019
Resolved
The emergency power available shall be sufficient to supply all those services which are necessary for the safety of all on board in an emergency. Emergency generator ran for two minutes and never provided the required load for the vessel. Provide class report attesting to emergency generator working as required.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 19 December 2019
Resolved 10 December 2019
11 - Life Saving Appliances › N/A - No Subsystem › Stowage and provision of liferafts
Issued 5 December 2019
Resolved
Liferafts should be stowed as to be readily available in case of emergency. Forward remote 6 man liferaft is stowed on raised deck that prevents it from being readily available for manual deployment. Provide class report attesting the liferaft was moved to an area where it is readily available
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Due 19 December 2019
Resolved 10 December 2019
11 - Life Saving Appliances › N/A - No Subsystem › Embarkation arrangement survival craft
Issued 5 December 2019
Resolved
Suitable arrangements shall be made for embarkation into liferafts. Crew unfamiliar with the forward embarkation area(s). Provide class report attesting the forward embarkation area exists with adequate ladder/securing points and lighting.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 19 December 2019
Resolved 10 December 2019
04 - Emergency Systems › N/A - No Subsystem › Fire drills
Issued 5 December 2019
Resolved
Vessel in ROS-5 status with minimum crew on board. Full crew complement to conduct fire and abandon ship drills before getting underway to the satisfaction of the attending CG inspector or ABS surveyor.
Condition: Invalid
Action required: 17 - Rectify deficiencies prior to departure
Due 31 May 2020
Resolved 27 August 2021
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 5 December 2019
Resolved
All required fire detection systems shall be capable of automatically indicating the presence of fire and its location. Existing fire detector at the top of the stair
well adjacent to safety gear locker is hanging from its wires. Provide class report attesting said detector is properly installed and tested sat.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 5 January 2020
Resolved 10 December 2019
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 5 December 2019
Resolved
Openings shall be provided with permanently attached means of closing which shall be at least effective for resisting fires as divisions in which they are fitted. Multiple doors in Engine Control did not close and latch properly. Provide class report that fire doors are closing and latching as designed.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 5 January 2020
Resolved 10 December 2019
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 5 December 2019
Resolved
Cables and wiring shall be installed and supported in such a manner as to avoid chafing or other damage. Wiring entering the "Sea Suction and Cooling Water" breaker box was missing the lock nut on the stuffing tube. Provide class report attesting to proper installation of the stuffing tube.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 5 January 2020
Resolved 10 December 2019
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 5 December 2019
Resolved
All exposed electrical equipment which are liable to become live shall be installed that danger shall not exist. Dead end cables exist for an existing fan in the dry store room and at an extension cord on the forward area of cargo deck #2. Provide class report attesting to removal of dead-end cables.
Condition: Damaged By Earlier Event
Action required: 50 - Rectify deficiencies w/in 30 days
Due 5 January 2020
Resolved 10 December 2019
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 5 December 2019
Resolved
Cables and wiring shall be installed and supported in such a manner as to avoid chafing or other damage. Wiring to the Sea Suction motor for the evaporator was supported. Provide class report attesting to proper installation of support of the power cable.
Condition: Damaged By Earlier Event
Action required: 50 - Rectify deficiencies w/in 30 days
Due 5 January 2020
Resolved 10 December 2019
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Maintenance of the ship and equipment
Issued 5 December 2019
Resolved
Where necessary, nonconducting mats shall be provided at the front and rear of the switchboard. No nonconducting matting at the AUX generator switchboard. Provide class report attesting to proper install of nonconductive mat.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 5 January 2020
Resolved 10 December 2019
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Shipboard operations
Issued 5 December 2019
Resolved
The company should establish procedures to ensure that the ship is maintained in conformity with the provisions of the relevant rules and regulations. Stbd generator reverse power relay does not trip until -120Hz while test procedures state the generator should trip at 70Hz. Provide class report that ship service generators trip off-line at manufacture recommended parameters and test procedures reflect.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 5 January 2020
Resolved 10 December 2019
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Shipboard operations
Issued 5 December 2019
Resolved
The company should establish procedures to ensure that the ship is maintained in conformity with the provisions of the relevant rules and regulations. Multiple test procedures are on entered correctly (reverse power relay, oil mist detectors, MDE leak alarm). Provide class report attesting to changes to Test Procedures to reflect proper testing procedures.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 5 January 2020
Resolved 10 December 2019
02 - Structural Conditions › N/A - No Subsystem › Closing devices/watertight doors
Issued 5 December 2019
Resolved
Ventilation openings shall be provided with watertight closing appliances. The 04 deck #6 fan sliding watertight closure's gasket is separating from the closure. Provide class report attesting to gasket being affixed to watertight closure.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 5 January 2020
Resolved 10 December 2019
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 5 December 2019
Resolved
The means of control of any fixed gas fire-extinguishing system shall be simple to operate. The instructions to use the E-gen space CO2 fixed system are inconspicuously located inside the time delay box. Provide class report attesting to instructions are easily found.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 5 January 2020
Resolved 10 December 2019
99 - Other › N/A - No Subsystem › Other (SOLAS operational)
Issued 5 December 2019
Resolved
After any survey of the ship has been completed, no change shall be made to the machinery, equipment. Identified non-working phones inside cargo area. Provide class report attesting to removal of non-working phones.
Condition: Damaged By Earlier Event
Action required: 50 - Rectify deficiencies w/in 30 days
Due 5 January 2020
Resolved 10 December 2019
04 - Emergency Systems › N/A - No Subsystem › Fire drills
Issued 9 July 2019
Resolved
Vessel is in ROS-5 status with minimum crew on board. Full crew complement to conduct fire and abandon ship drills before getting underway to satisfaction of attending CG inspector or ABS surveyor. 60 SOLAS III/26
Condition: Invalid
Action required: 17 - Rectify deficiencies prior to departure
Due 9 July 2019
Resolved 23 August 2019
Resolution: Fire and abandon ship drills completed to satisfaction of attending CG Marine Inspectors.
07 - Fire Safety › N/A - No Subsystem › Fire-dampers
Issued 9 July 2019
Resolved
The main inlets and outlets of all ventilation systems shall be capable of being closed from outside the space.
The crew was unable to demonstrate securing ventilation to galley and actuating fire dampers located outside the galley. Locate, label and demonstrate proper operation of all galley fire dampers w/in 30 days. 60 SOLAS II/47
Condition: Placed in Improper Service
Action required: 50 - Rectify deficiencies w/in 30 days
Due 9 August 2019
Resolved 21 August 2019
Resolution: Cleared by ABS report of 21 Aug 2019. #1205.
18 - Maritime Labour Convention (Not Applicable to PSC Exams conducted in the U.S.) › N/A - No Subsystem › Hospital accommodation (Sickbay)
Issued 9 July 2019
Resolved
The hospital accommodation should ensure the comfort and facilitate the treatment of the occupants. The hospital hot water lines provide highly rusty water, Shower thermostat not working, curtain missing. Sanitize & recondition space w/in 30 days.46 CFR 91.35-1 ILO 147 60 SOLAS I-11
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 9 August 2019
Resolved 21 August 2019
Resolution: Repaired & cleared by ABS.
09 - Working and Living Conditions › 092 - Working Conditions › Other (working space ILO)
Issued 9 July 2019
Resolved
Sanitary facilities shall be provided for all members of the crew. Crew/Port Eng id'd several water closets have wasted "p traps" drain piping and no longer protect crew from sewage vapors. Repair id'd room drains, survey addl spaces for repair to retore habitability w/in 30 days. 46 CFR 91.35-1
ILO 147
60 SOLAS I-11
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 9 August 2019
Resolved 21 August 2019
Resolution: To be repaired during drydock. Class issued finding 1211. Cleared.
01 - Certificates & Documentation › 013 - Documents › Fire control plan - all
Issued 9 July 2019
Resolved
Ship shall exhibit for the guidance of the ship's officer's plans clearly showing fire detection systems and life saving equipment. New installation fire control panel not on the fire control plan. New EPIRB/VDR on flying bridge not indicated on plan. Update plan to reflect new installations w/in 30 days. 60 SOLAS II/70
Condition: Placed in Improper Service
Action required: 50 - Rectify deficiencies w/in 30 days
Due 9 August 2019
Resolved 21 August 2019
Resolution: Accepted ABS report. Cleared.
10 - Safety of Navigation › N/A - No Subsystem › Echo sounder
Issued 9 July 2019
Resolved
No change shall be made to equipment after survey. Bridge depth sounder's screen is not readable due to dimmer not functioning. Conduct repairs w/in 30 days to satisfaction of attending ABS Surveyor.60 SOLAS I/11
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 9 August 2019
Resolved 21 August 2019
Resolution: CLass has open item, vessel has working depth indicator repeater, monitor to be fixed in drydock. Cleared.
11 - Life Saving Appliances › N/A - No Subsystem › Lifeboats
Issued 9 July 2019
Resolved
No change shall be made to equipment after survey.
Starboard lifeboat retro-reflective tape is faded out and needs to be replaced. Conduct repairs to satisfaction of attending ABS Surveyor. 60 SOLAS I/11
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 9 August 2019
Resolved 21 August 2019
Resolution: Corrected to ABS satisfaction.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 9 July 2019
Resolved
Life jackets shall be so placed as to be readily accessible. One of the required PFDs on the bridge was missing. The one on the bridge had expired light.
Replace life jackets to satisfaction of Attending CG inspector. 60 SOLAS III/22
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 9 July 2019
Resolved 1 November 2019
Resolution: cleared onboard
11 - Life Saving Appliances › N/A - No Subsystem › Lifeboats
Issued 6 December 2018
Resolved
Vessel port side motor lifeboat missing retro reflective tape. Replace Type III retro-reflective tape on underside of port lifeboat, to meet IMO Res A.658(16)
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 20 December 2018
Resolved 28 February 2019
Resolution: Cleared by ABS report on 20 DEC 2019, item 1157.
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 6 December 2018
Resolved
Fire doors in main vertical zone bulkheads other than watertight doors shall be of self closing type with simple and easy means of release. Galley door was secured in the open position. Remove all hold-backs that are not subject to control station release.
60SOLAS II-D/38.e
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 20 December 2018
Resolved 28 February 2019
Resolution: Cleared by ABS report on 20 DEC 2019, item 1157.
07 - Fire Safety › N/A - No Subsystem › Division - decks, bulkheads and penetrations
Issued 6 December 2018
Resolved
Lift trunks shall be fitted as to prevent the passage of smoke and flame from one between deck to another and shall be provided with means of closing so as to permit of draught and smoke control. Dumbwaiter in galley was used as storage and secured open. Secure dumbwaiter door when not in use.
60SOLAS II-D/43.h
Condition: Placed in Improper Service
Action required: 16 - Rectify deficiencies w/in 14 days
Due 20 December 2018
Resolved 28 February 2019
Resolution: Cleared by ABS report on 20 DEC 2019, item 1157.
14 - Pollution Prevention › 145 - MARPOL Annex V › Garbage management plan
Issued 6 December 2018
Resolved
Every ship of 400 gross tonnage and above, and every ship which is certificated to carry 15 passengers or more, shall carry a garbage management plan which the crew shall follow. Separate bins were of mixed waste and garbage was found in clean rags bin. Follow garbage management plan.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 6 January 2019
Resolved 28 February 2019
Resolution: ABS class report dated 20 DEC 2019, reimplimented garbage mgt program, ABS report item 1157.
09 - Working and Living Conditions › 091 - Living Conditions › Electrical devices
Issued 6 December 2018
Resolved
Wiring shall be supported in such a manner as to avoid chafing or other injury. Receptacle cable in ECR runs verticallyh, drapes over a cabinet at runs down the side over a desk, then plugs into a power strip. Support cable run and terminate cable into a juction box or circuit breaker, or remove receptable/cable.
74SOLAS(60)II/C/27.a.vi
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 6 January 2019
Resolved 28 February 2019
Resolution: Cleared by ABS report on 20 DEC 2019, item 1157.
09 - Working and Living Conditions › 092 - Working Conditions › Cleanliness of engine room
Issued 6 December 2018
Resolved
Survey shall be such as to ensure that the arrangements, material, and scantlings of the structure, boilers and other pressure vessels and their appurtenances, main and auxiliary machinery, electrical installations and other equipments are in all respects staisfactory for the service for which the ship is intended. Engine room bilge contains oil rags, cans, respirator and face shield. Remove items from bilge area.
74SOLAS(60)I/B/10
Action required: 50 - Rectify deficiencies w/in 30 days
Due 6 January 2019
Resolved 28 February 2019
Resolution: Cleared by ABS report on 20 DEC 2019, item 1157.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 6 December 2018
Resolved
The safety of passengers, crew and ship from electrical hazards will be assured. Light fixture in lowest level engine room has missing lens cover and exposed circuit parts within head level of personnel. Repair light fixture to proper operation with cover installed.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 6 January 2019
Resolved 28 February 2019
Resolution: Cleared by ABS report on 20 DEC 2019, item 1157.
09 - Working and Living Conditions › 092 - Working Conditions › Pipes, wires (insulation)
Issued 6 December 2018
Resolved
Survey shall be such as to ensure that the arrangements, material, and scantlings of the structure, boilers and other pressure vessels and their appurtenances, main and auxiliary machinery, electrical installations and other equipments are in all respects satisfactory for the service for which the ship is intended. Unidentified pipe system in lowest part of engine room on starboard aft end has a hole in it and is leaking down the side of vessel. Identify piping system with hole and repair to satisfaction of attending Marine Inspector.
74SOLAS(60)I/B/10
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 6 January 2019
Resolved 28 February 2019
Resolution: Cleared by ABS report on 20 DEC 2019, item 1157.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 6 December 2018
Resolved
The safety of passengers, crew and ship from electrical hazards will be assured. There is a deadended cable located at lowest engine room level on starboard side back where the shaft exits the vessel. Remove dead ended cable or repair the previous circuit/load.
74SOLAS(60)II/C/23.a.ii
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 6 January 2019
Resolved 28 February 2019
Resolution: Cleared by ABS report on 20 DEC 2019, item 1157.
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 6 December 2018
Resolved
Power shall be sufficient to supply emergency lighting in the main machinery space and main generating set space. Emergency lighting fixture above the shaft in lowest engine room level was not operational. Restore emergency lighting to proper operation.
74SOLAS(60)II/C/26.a(ii)(1)
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 6 January 2019
Resolved 28 February 2019
Resolution: Cleared by ABS report on 20 DEC 2019, item 1157.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 6 December 2018
Resolved
The safety of passengers, crew and ship from electrical hazards will be assured. Push button switch box in F/O purifier room for exhaust fan has cable conductors exposed pulling out of bottom stuffing tube. Secure cable/conductors into stuffing tube properly.
74SOLAS(60)II/C/23.a.ii
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 6 January 2019
Resolved 28 February 2019
Resolution: Cleared by ABS report on 20 DEC 2019, item 1157.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 6 December 2018
Resolved
Survey shall be such as to ensure that the arrangements, material, and scantlings of the structure, boilers and other pressure vessels and their appurtenances, main and auxiliary machinery, electrical installations and other equipments are in all respects satisfactory for the service for which the ship is intended. F/O separators in the purifier room have missing hardware from bottom piping strainer contraption devices or their covers. Install missing hardware/secure covers.
74SOLAS(60)I/B/10
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 6 January 2019
Resolved 28 February 2019
Resolution: Cleared by ABS report on 20 DEC 2019, item 1157.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 6 December 2018
Resolved
Survey shall be such as to ensure that the arrangements, material, and scantlings of the structure, boilers and other pressure vessels and their appurtenances, main and auxiliary machinery, electrical installations and other equipments are in all respects satisfactory for the service for which the ship is intended. Starboard SSDG has an exhaust leak coming from the turbo area. Repair exhaust leak to the satisfaction of the attending Marine Inspector.
74SOLAS(60)I/B/10
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 6 January 2019
Resolved 28 February 2019
Resolution: Cleared by ABS report on 20 DEC 2019, item 1157.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 6 December 2018
Resolved
Survey shall be such as to ensure that the arrangements, material, and scantlings of the structure, boilers and other pressure vessels and their appurtenances, main and auxiliary machinery, electrical installations and other equipments are in all respects satisfactory for the service for which the ship is intended. Main engine has J/W leaks throughout its piping system. Conduct a J/W system inspection and repair all leaks to the satisfaction of the attending Marine Inspector.
74SOLAS(60)I/B/10
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 6 January 2019
Resolved 28 February 2019
Resolution: Cleared by ABS report on 20 DEC 2019, item 1157.
Documentation › Safety/Response Plans/Programs › Fire Control Plans
Issued 19 June 2018
Resolved
Fire control Plan shall be kept up to date, plan found not up to date.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 20 July 2018
Resolved 20 July 2018
Resolution: Cleared over the summer but not updated in database until 12-07-18. verified cleared during add'l oversight inspn.
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 19 June 2018
Resolved
Moving machinery parts shall be guarded to protect from personnel hazards. Found ballast pumps #1, #2 and a general service pump without guards.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 July 2018
Resolved 20 July 2018
Resolution: cleared.
Documentation › Manuals/Policy Documentation › Vessel Specific Watch Policy/Procedures
Issued 19 June 2018
Resolved
PSTps are not being followed for emergency generator high jacket water alarm testing. Update PSTP.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 19 July 2018
Resolved 1 November 2019
Resolution: PTSP updated 07/01/2019
Operations/Management › Drills/Instruction › Not Conducted
Issued 19 June 2018
Resolved
Vessel shall conduct life boat operational test prior to getting underway.
Condition: Invalid
Action required: 60 - Rectify deficiencies prior to movement
Resolved 28 September 2018
Resolution: Vessel conducted life boat operational tests to satisfaction of Attending Marine Inspector.
Operations/Management › Drills/Instruction › Not Conducted
Issued 19 June 2018
Resolved
Vessel shall conduct fire drill prior to getting underway.
Action required: 60 - Rectify deficiencies prior to movement
Resolved 28 September 2018
Resolution: Vessel conducted fire drill to satisfaction of Attending Marine Inspector.
Operations/Management › Drills/Instruction › Abandon Ship
Issued 19 June 2018
Resolved
Vessel shall conduct abandon ship drills prior to getting underway.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 28 September 2018
Resolution: Vessel conducted abandon ship drill to satisfaction of Attending Marine Inspector.
Fire Fighting › Emergency Fire Pumps › Pressure
Issued 19 June 2018
Resolved
The emergency fire pump shall be capable of supplying two jets of water, witnessed low pressure during test.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 July 2018
Resolved 26 July 2018
Resolution: Witnessed satisfactory test. Details in narrative.
Personnel › Training › Watchkeeping
Issued 20 March 2018
Resolved
A ship when in port or an offshore terminal of another Party is subject to inspection by officers duly authorized by such Party concerning operational requirements under this Annex, where there are clear grounds for believing that the master or crew are not familiar with essential shipboard procedures relating to the prevention of pollution by oil. Crew was unfamiliar with testing procedures for the OWS. Prove to attending Marine Inspectors crew knowledge for performing OWS test procedures. MARPOL I/11.1
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Resolved 19 June 2018
Resolution: All sat.
Electrical › Electrical Distribution System (service) › Metallic Enclosure/Frame
Issued 20 March 2018
Resolved
The sides and backs and, where necessary, the fronts of the switchboards shall be suitably guarded. Motor control centers had missing hardware, openings that were meant for meters or push buttons, and doors left open. Replace hardware, ensure motor control enclosure doors can secure, and cover openings to the satisfaction of Marine Inspectors. 74SOLAS(60)II/27(a)(ii)
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Resolved 19 June 2018
Resolution: //s// [name withheld], LT, Marine Inspector, USCG
Electrical › Lighting (emergency) › Lighting Fixture
Issued 20 March 2018
Resolved
Emergency lighting shall be sufficient for the safety of all on board in an emergency with special consideration for the main machinery space and main generating set space. Multiple emergency light fixtures throughout the machinery spaces were found inoperative when tested. Prove satisfactory operation of emergency light fixture tests to the satisfaction of Marine Inspectors. 74SOLAS(60)II/26(a)(ii)(1)
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Resolved 19 June 2018
Resolution: Cleared, see ABS report.
Operations/Management › Bilge/Bilge System Management › Control of Oil Mixtures
Issued 20 March 2018
Resolved
After any survey of the ship, no change shall be made in the structural arrangements, machinery, equipments, covered by the survey, without the sanction of the Administration. Numerous instances of oil soaked rags, oil soaked diapers, and drip buckets to collect leakage is present in the purifier space bilges presenting a high risk of fire. Repair leaks and remove oil soaked rags/diapers from bilge to the satisfaction of Marine Inspector. 74SOLAS(60)I/11
Action required: 60 - Rectify deficiencies prior to movement
Resolved 19 June 2018
Resolution: Cleared, see ABS report.
Construction/Loadline › Structures › Ventilators
Issued 20 March 2018
Resolved
Ventilator openings shall be provided w/watertight closing appliances.Supply/exhaust ventilators were missing/couldn't prove proper operation of closing appliances. Repair to satisfaction of class/CG. Prior to movement. ICLL 66 I/19.4
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Resolved 19 June 2018
Resolution: Cleared, see ABS report.
Construction/Loadline › Structures › Air Pipe
Issued 20 March 2018
Resolved
Exposed parts of air pipes to ballast & other tanks shall be of substantial construction. Air pipes did not have appropriate securing pin. Gooseneck vents had inoperable covers. Correct to satisfaction of CG/Class. Prior to movement. ICLL 66 II/20
Action required: 60 - Rectify deficiencies prior to movement
Resolved 19 June 2018
Resolution: Cleared, see ABS report.
Lifesaving › Lifejacket/PFD (General) › Lights
Issued 20 March 2018
Resolved
All lifesaving appliances shall be kept in working order. Lifejackets on board had expired lights installed. Lifejackets not located in designated area/found in unmarked container. Correct to satisfaction of class/CG prior to sailing. SOLAS (60)III/4.c
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Resolved 19 June 2018
Resolution: Cleared, see ABS report.
Fire Fighting › Fire Main › Condition
Issued 20 March 2018
Resolved
Fire extinguishing appliances in new and existing passenger ships and cargo ships shall be kept in good order and available for immediate use at all times during the voyage. Fire station supply valve in the engine room is severely corroded around valve stem and is leaking onto piping elbow below. Pipe elbow has wastage due to the constant leak. Repair leaking valve stem and repair/replace or provide testing of pipe elbow structural tolerance to the satisfaction of the Marine Inspectors. 74SOLAS(60)II/66
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Resolved 19 June 2018
Resolution: Cleared, see ABS report.
Fire Fighting › Structural - A Class Divisions › Main Galleys
Issued 20 March 2018
Resolved
Bulkheads of galley when adjacent to accomodation space shall be or equivalent material. Doors into galley from stairwell don't provide positive means of closure. Cable penetrations through galley bulkhead aren't sealed. Serving window in galley unable to close. Fire damper in galley zip-tied in open position. Space between galley/pantry has cut out bulkhead forming door not depicted on fire control plan. Correct to satisfaction of class/CG. Prior to movement. SOLAS(60) II/54.e.
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Resolved 19 June 2018
Resolution: Cleared, see ABS report.
Electrical › Lighting (emergency) › Lighting Fixture
Issued 20 March 2018
Resolved
Administration shall ensure that lighting of alleyways/stairways/exits is such that access to lifeboats/rafts is not impeded. Several emergency lights were non-operational when tested from boat deck to bridge. Correct to satisfaction of CG/class. Prior to movement. SOLAS (60)III/38
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Resolved 19 June 2018
Resolution: Cleared, see ABS report.
Engineering › Steering Gear System › Pump
Issued 20 March 2018
Resolved
Ships shall be provided w/main & aux steering gear to satisfaction of Administration. Vsl could not prove proper operation of main or aux steering gear. Correct to satisfaction of CG/Class. Prior to movement. SOLAS (60)II/29.A
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Resolved 19 June 2018
Resolution: Cleared, see ABS report.
Navigation › Collision/Grounding Avoidance › Echo-sounding Device
Issued 20 March 2018
Resolved
Vsl must have an echo depth sounding device. Display of of depth sounding device is unlit and not readable. Correct to satisfaction of CG/Class. Prior to movement. 33CFR164.35(H)
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Resolved 19 June 2018
Resolution: Cleared, see ABS report.
Navigation › Piloting/Steering › Marine Charts
Issued 20 March 2018
Resolved
Vsl must have marine charts of area to be transited that are currently corrected, large enough & detailed enough to make safe navigation of area possible. No current charts onboard. Correct to satisfaction of CG/Class. Prior to movement. 33CFR164.33
Condition: Placed in Improper Service
Action required: 60 - Rectify deficiencies prior to movement
Resolved 19 June 2018
Resolution: Cleared, see ABS report.
Communications › Radio Communications › Satellite Communications Capability
Issued 20 March 2018
Resolved
Every ship shall be provided w/radio installations capable of complying w/functional requirements throughout its intended voyage. INMARSAT C is non-operable. Prove proper operation to Class/CG. SOLAS (14)IV/6.1
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Resolved 19 June 2018
Resolution: Cleared, see ABS report.
Construction/Loadline › Structures › Superstructure
Issued 20 March 2018
Resolved
Superstructure shall be constructed of steel, except where Administration may sanction use of other suitable materials. Significant corrosion noted where bulkhead meets deck on stbd side boat deck. Correct to satisfaction of CG/Class. 30 Days. SOLAS (60) II/54.A
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Resolved 19 June 2018
Resolution: Cleared, see ABS report.
Fire Fighting › Structural - A Class Divisions › Aux Spaces (moderate fire risk)
Issued 20 March 2018
Resolved
Decks shall be constructed of steel or other suitable material approved by Administration. ON e-deck through-bulkhead & through-deck cable runs are unsatisfactory (cable rm). 02 metallic cable through-bulkhead penetration unsatisfactory (pipe passage). A-deck cable trunk, through-deck cable penetrations unsat. On bridge, aft bulkhead, amidships through deck penetration unsat. Correct to satisfaction of CG/CLass. SOLAS (60)II/54.A
Condition: Improper Installation
Action required: 60 - Rectify deficiencies prior to movement
Resolved 19 June 2018
Resolution: Cleared, see ABS report.
Lifesaving › Lifeboat Equipment › Pump (manual)
Issued 20 March 2018
Resolved
Normal equipment of every lifeboat shall consist of manual pump of an approved type. Bilge pumps on both lifeboats are inoperable. Prove proper operation to satisfaction of CG/Class. Prior to movement. SOLAS (60) III/11.a.xxii
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Resolved 19 June 2018
Resolution: Cleared, see ABS report.
Construction/Loadline › Markings › Summer Load Line
Issued 20 March 2018
Resolved
Rings, lines and letters shall be permanently marked on sides of the ships to satisfaction of Administration. Summer loadline not permanently marked on stbd side of ship. Correct to satisfaction of CG/Class. Prior to movement. ICLL (66)I/8
Condition: Improper Installation
Action required: 60 - Rectify deficiencies prior to movement
Resolved 19 June 2018
Resolution: Cleared, see ABS report.
Fire Fighting › Structural - A Class Divisions › Aux Spaces (moderate fire risk)
Issued 20 March 2018
Resolved
"A" class divisions are formed by bulkheads and decks shall be constructed of steel or equivalent material. Radio room rated A60 as per fire control plan. A60 door not closing. Corrected on spot. SOLAS (60) II/35.c.i
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 20 March 2018
Lifesaving › Lifebuoys › Buoyant Lifeline
Issued 20 March 2018
Resolved
Life saving appliances shall be kept in working order. Bridge wing port lifebuoy lifeline dry rotted beyond use. Correct to satisfaction of CG/class. 30 days.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 20 April 2018
Resolved 19 June 2018
Resolution: Cleared, see ABS report.
Fire Fighting › Ventilation Systems › Fans
Issued 20 March 2018
Resolved
Power ventilation of machinery spaces shall be capable of being stopped from an easily accessible position outside machinery spaces. Supply ventilation fans tagged out, not available for inspection, unable to test shutdown of ventilation to cargo spaces. 30 days. SOLAS (60)II/54.J
Condition: Invalid
Action required: 705 - Other - as specified
Due 20 April 2018
Resolved 19 June 2018
Resolution: Cleared, see ABS report.
Construction/Loadline › Structures › Door
Issued 20 March 2018
Resolved
All access openings in bulkheads at ends of enclosed superstructures shall be fitted w/steel, permanently & strongly attached to bulkhead & weathertight when closed. Means for securing doors weathertight shall consist of gasket & clamping device. Doors on e/r stack entrance from boat deck on port and stbd side missing gaskets & have broken dogs. Correct to satisfaction of CG/class. 30 days. ILCC 66 II/12
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 20 April 2018
Resolved 19 June 2018
Resolution: Cleared, see ABS report.
Lifesaving › Lifeboat › Embarkation/Disembarkation Capabilities
Issued 20 March 2018
Resolved
All lifesaving appliances shall be kept in working order & available for immediate use. Chafing gear on port side lifeboat gripes is worn beyond useful life. Correct to satisfaction of CG/class. 30 days. SOLAS (60)III/4.c.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 20 April 2018
Resolved 19 June 2018
Resolution: Cleared, see ABS report.
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 20 March 2018
Resolved
Efficient guard rails or bulwarks shall be fitted to all exposed parts of freeboard & superstructure decks. Cargo deck railing was found in poor condition w/several loose railings. Correct to satisfaction of CG/class. 30 days. ICLL 66 II/25.2
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 20 April 2018
Resolved 19 June 2018
Resolution: Cleared, see ABS report.
Accommodation/Occupational Safety › Washroom/Toilet › Toilet
Issued 20 March 2018
Resolved
Water closets shall be provided w/ample flush of water at all times & independently controlled. Several toilets seen in accomodation spaces on E-deck did not flush. Correct to satisfaction of CG/class. Prior to movement. ILO 147 Crew Accomodations 21.F.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 19 June 2018
Resolution: Cleared, see ABS report.
Accommodation/Occupational Safety › Sleeping Accommodations › Berth
Issued 20 March 2018
Resolved
Crew accomodation shall be adequately lighted. Several light fixtures in accomodation spaces on E-deck were either broken or non-operational.Correct to satisfaction of CG/class. 30 days. ILO 147 Crew Acommodation #6.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 20 April 2018
Resolved 19 June 2018
Resolution: Cleared, see ABS report.
Fire Fighting › Structural - A Class Divisions › Machinery Spaces
Issued 20 March 2018
Resolved
Fire resisting divisions which are formed by bulkheads and decks shall have an insulating valve to satisfaction of Administration. EDG/E-switchboard room have fire protection insulation worn beyond useful life. Correct to satisfaction of CG/class. Prior to movement. SOLAS (60) II/35.c.iv
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Resolved 19 June 2018
Resolution: Cleared, see ABS report.
Operations/Management › Vessel Safety Management › Maintenance of Ship/Equipment
Issued 20 March 2018
Resolved
Based on findings of CG/Class, Coast Guard requires SMS audit of Company and Vessel by authorized classification society IAW NVIC 2-95 prior to re-issuance of COI.
Action required: 705 - Other - as specified
Resolved 19 June 2018
Resolution: Cleared.
Documentation › Certificates/Documents › Certificate of Inspection
Issued 20 March 2018
Resolved
Inspection to satisfaction of OCMI based on all applicable rules and regulations prior to re-issuance of COI.
Action required: 705 - Other - as specified
Resolved 19 June 2018
Resolution: Cleared, COI issued.
Operations/Management › Navigation Safety › Navigation Underway, General
Issued 8 May 2017
Resolved
It shall be possible to initiate transmission of distress alerts by radio installations from the position from which the ship is normally navigated. MF and HF radio installations on the nav bridge were inoperable. Prove proper operation of MF and HF radios on the nav bridge. Until such time that the MF and HF radios are repaired, a radio watch must be provided in the radio room while underway.
Action required: 705 - Other - as specified
Due 8 June 2017
Resolved 20 March 2018
Operations/Management › Drills/Instruction › Not Conducted
Issued 19 April 2017
Resolved
Conduct all drills prior to getting underway.
Action required: 17 - Rectify deficiencies prior to departure
Due 19 May 2017
Resolved 8 May 2017
Resolution: Drills conducted.
Fire Fighting › Fire Hydrants › Condition
Issued 19 April 2017
Resolved
A valve shall be fitted to serve each fire hydrant so that any fire hose may be removed. Mutliple valves were leaking substantially. Repair/replace.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 19 May 2017
Resolved 8 May 2017
Resolution: Leaking valves were repaired/replaced.
Operations/Management › Navigation Safety › Navigation Underway, General
Issued 19 April 2017
Resolved
Prove proper operation of AIS and GMDSS prior to getting underway.
Action required: 17 - Rectify deficiencies prior to departure
Due 19 May 2017
Resolved 8 May 2017
Resolution: GMDSS and AIS were proven to be operational.
Fire Fighting › Fixed Fire Detection System › Arrangement
Issued 19 April 2017
Resolved
Remove inoperable redundant fire system or prove proper operation.
Action required: 705 - Other - as specified
Due 19 May 2017
Resolved 8 May 2017
Resolution: Redundant fire detection system was blanked off and taken out of service.
Electrical › Electric Supply System (service) › Cable
Issued 19 April 2017
Resolved
All electrical apparatus shall be so constructed as to not cause injury. Electrical components on GMDSS were exposed due to missing cover. Replace cover.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 19 May 2017
Resolved 8 May 2017
Resolution: Electrical cover was put in place.
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 19 April 2017
Resolved
All vessels shall have efficient guard rails. STBD stern and midship rails were found wasted. Repair all wasted areas.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 19 May 2017
Resolved 8 May 2017
Resolution: Rails were repaired.
Electrical › Lighting (service) › Lighting Fixture
Issued 19 April 2017
Resolved
Each space used by crew must be fitted with lighting that provides a safe working environment. Lighting was not adequate.
Action required: 705 - Other - as specified
Due 19 May 2017
Resolved 8 May 2017
Resolution: Additional lighting was provided.
Fire Fighting › Fixed Pressure Water-Spraying Fire Extinguishing System › Valves
Issued 19 April 2017
Resolved
valve reach rods must be adequately protected. Emergency fire pump iso valve reach rod handle on STBD, FWD main deck was found wasted. Repair/replace.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 19 May 2017
Resolved 8 May 2017
Resolution: Valve reach rod was repaired.
Deck/Cargo › Cargo Stowage › General
Issued 19 April 2017
Resolved
Port and STBD hydrolic pumps on #3 cargo hold is excessively leaking. Repair and clean area.
Action required: 705 - Other - as specified
Due 19 May 2017
Resolved 8 May 2017
Resolution: Hydraulic pumps were repaired and hydraulic oil was cleaned.
Engineering › Feedwater/Condensate Water System › Pump
Issued 19 April 2017
Resolved
Vessel's raw water motors do not have safeguards on rotating machinery. Adequate guards must be installed.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 8 June 2017
Resolved 20 March 2018
Engineering › Diesel Engine (propulsion-direct drive) › Piping (air intake)
Issued 19 April 2017
Resolved
Piping on vessel's STBD MDE cylinder heads #5 and #6 are bent/pinched. Repair/replace to prevent further mechanical damage.
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Due 19 May 2017
Resolved 8 May 2017
Resolution: Piping was repaired.
Lifesaving › Line-Throwing Appliances › Projectiles
Issued 27 April 2016
Resolved
Line-Throwing rockets were expired on all guns.
Condition: Invalid
Action required: 17 - Rectify deficiencies prior to departure
Resolved 20 March 2018
Resolution: Replace expired Line-Throwing gun and place on station for use prior to departure to the satisfaction of a USCG Marine Inspector
Lifesaving › Lifeboat Equipment › Anti-seasickness Medicine
Issued 27 April 2016
Resolved
All lifeboat Seasickness pills were expired
Condition: Invalid
Action required: 17 - Rectify deficiencies prior to departure
Resolved 20 March 2018
Resolution: Replace expired sea sickness pills.
Lifesaving › Lifeboat Equipment › Food Ration
Issued 27 April 2016
Resolved
All lifeboat food rations are expired
Condition: Invalid
Action required: 17 - Rectify deficiencies prior to departure
Resolved 20 March 2018
Resolution: Replace all expired food rations.
Lifesaving › Rocket Parachute Flares › General
Issued 27 April 2016
Resolved
ALl Rocket flares on board were expired
Condition: Invalid
Action required: 17 - Rectify deficiencies prior to departure
Resolved 21 March 2018
Resolution: Replace all Rocket flares prior to departure
Lifesaving › Hand Flares › Expired
Issued 27 April 2016
Resolved
All hand flares were expired
Condition: Invalid
Action required: 17 - Rectify deficiencies prior to departure
Resolved 20 March 2018
Resolution: Replace all hand flares on board
Accommodation/Occupational Safety › Refrigeration (air conditioning) › General
Issued 11 March 2014
Resolved
Repair/renew all damaged/burnt items in the a/c compressor space to the satisfaction of the ACP class society.
Condition: Invalid
Action required: 705 - Other - as specified
Due 7 April 2014
Resolved 31 March 2014
Resolution: All marchinery in the space serviced/repaired and tested satifactory.
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 13 July 2011
Resolved
Navigation light mounting brackets more than 50% wasted. Renew mounting brackets as original, screens to be matte black. To the satisfaction of the attending marine inspector.
Action required: 705 - Other - as specified
Due 13 September 2011
Resolved 13 September 2011
Resolution: Brackets and nav. lights renewed.
Navigation › Collision/Grounding Avoidance › Radar
Issued 13 July 2011
Resolved
Provide documentation of satisfactory operation of the ships 10cm radar. Display on screen flickering.
Action required: 705 - Other - as specified
Due 13 September 2011
Resolved 13 September 2011
Resolution: Witnessed proper operation of radar.
Construction/Loadline › Hull › Hull Plating
Issued 25 January 2010
Resolved
There was a 12' x 8' inset with internal member damage to the port hull below the lifeboat.
Action required: 705 - Other - as specified
Due 31 May 2010
Resolved 7 June 2010
Resolution: 07 June 2010 CG Sector Houston recieved ABS Class Damage Survey report attesting satisfactory compliance of repairs to port side shell plating, Main deck, Frames 35-43. on 04Jun2010.
Lifesaving › Launching Appliances › Falls
Issued 17 August 2006
Resolved
Renew starboard lifeboat falls and conduct suitable weight test in the presence and to the satisfaction of the attending Coast Guard marine Inspector.
Action required: 705 - Other - as specified
Due 23 August 2006
Resolved 21 August 2006
Resolution: Observed satisfactory weight test of new starboard lifeboat falls.
Electrical › Electrical Distribution System (emergency) › Distribution Panel Bus
Issued 5 May 2005
Resolved
The Emergency generator automatic bus transfer circuitry must be tested to the satisfaction of a Coast Guard Marine Inspector.
Condition: Unknown
Action required: 705 - Other - as specified
Due 19 July 2005
Resolved 19 July 2005
Resolution: Complete
Fire Fighting › Fixed Fire Detection System › Smoke Detectors
Issued 5 May 2005
Resolved
Prove proper operation of the fire detection system to the satisfaction of a Coast Guard Marine Inspector.
Condition: Unknown
Action required: 705 - Other - as specified
Due 6 June 2005
Resolved 19 July 2005
Resolution: Complete.
Construction/Loadline › Structures › Ventilators
Issued 5 May 2005
Resolved
Crop and renew to good metal the wasted vent for the engine room ladder trunk, port side A-deck.
Condition: Unknown
Action required: 705 - Other - as specified
Due 6 June 2005
Resolved 19 July 2005
Resolution: Complete.
Construction/Loadline › Structures › Ventilators
Issued 5 May 2005
Resolved
Crop and renew to good metal the wasted vent in dry stores, 1st deck stbd side in way of Bosun's locker.
Condition: Unknown
Action required: 705 - Other - as specified
Due 6 June 2005
Resolved 19 July 2005
Resolution: Complete
Lifesaving › Launching Appliances › Falls
Issued 5 May 2005
Resolved
Conduct lifeboat davit weight test.
Condition: Unknown
Due 1 November 2005
Resolved 30 June 2006
Resolution: Reviewed supporting documentation; All Sat
Fire Fighting › Grease Extraction Hood › General
Issued 6 July 2004
Resolved
A new fire extinguishing system was installed with no provision or instruction for securing the power to the protected equipment. Provide a means by which to secure the power to the deep fat fryer and the stove upon activation of the fire extinguishing system.
Due 20 September 2004
Resolved 13 October 2004
Resolution: Unitor installed a set of contacts to de-energize the galley equipment upon activation of the fire extinguishing system. Proper operation was documented by Unitor and the installation was viewed the inspector.
Fire Fighting › Fixed Fire Detection System › Smoke Detectors
Issued 6 July 2004
Resolved
Test the smoke detection system for all cargo holds.
Action required: 705 - Other - as specified
Due 20 September 2004
Resolved 13 October 2004
Resolution: Witnessed satisfactory test of smoke detection system in all cargo holds.
Stability › Watertight Integrity › General
Issued 6 July 2004
Resolved
Replace both escape hatches on the main deck for the lower holds.
Action required: 705 - Other - as specified
Due 20 September 2004
Resolved 13 October 2004
Resolution: Contractors installed new hatches. Viewed installation and cleared deficiency.
Lifesaving › Launching Appliances
Issued 21 October 2003
Resolved
Gravity brake on port and starboard life boat inoperative LEGACY COMPONENT DESC: Winch Brake
Action required: 705 - Other - as specified
Due 20 November 2003
Resolved 29 January 2004
Resolution: CG tested. Satisfactory.
Lifesaving › Launching Appliances
Issued 21 October 2003
Resolved
Port and starboard lifeboat davit limit switches inoperative LEGACY COMPONENT DESC: Davit
Action required: 705 - Other - as specified
Due 20 November 2003
Resolved 29 January 2004
Resolution: CG tested. All sat.
Fire Fighting › Fixed CO2 Fire Extinguishing System
Issued 21 October 2003
Resolved
Provide inspection certificates documenting satisfactory inspection and testing of fixed and portable fire fighting systems
Action required: 705 - Other - as specified
Due 20 November 2003
Resolved 29 January 2004
Resolution: CG viewed servicing certificates. All sat.
Engineering › Steering Gear System
Issued 21 October 2003
Resolved
Low hydraulic oil alarm light on bridge panel inoperative
Action required: 705 - Other - as specified
Due 20 November 2003
Resolved 29 January 2004
Resolution: CG tested. All sat.
Engineering › Diesel Engine (propulsion-reduction gear)
Issued 21 October 2003
Resolved
Reconnect lube oil line on starboard MDE and repair air leak on fuel rack control
Action required: 705 - Other - as specified
Due 20 November 2003
Resolved 29 January 2004
Resolution: CG inspected. All sat.
Engineering › Generator (propulsion/auxiliary-electric)
Issued 21 October 2003
Resolved
Repair reverse power relay for #1 generator
Action required: 705 - Other - as specified
Due 20 November 2003
Resolved 29 January 2004
Resolution: CG inspected. All sat.
Engineering › Fuel Oil Service System › Heater
Issued 21 October 2003
Resolved
Modify automation test procedures for new thermal fluid heater control system
Action required: 705 - Other - as specified
Due 20 November 2003
Resolved 9 August 2004
Navigation › Piloting/Steering
Issued 8 March 2002
Resolved
Inoperable gyro compass; 33 CFR 164.35; Provide tech report attesting to repair and operation of gyro. LEGACY COMPONENT DESC: Gyro Compass
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Due 8 March 2002
Resolved 9 March 2002
Resolution: Received sat repair tech report- gyro repaired and operating properly.
Electrical
Issued 9 May 2000
Resolved
CONDUCT TESTS OF #2 PORT S/S GENERATOR TO SATISFACTION OF ATTENDING CG MARINE INSPECTOR.
Condition: Unknown
Due 1 August 2000
Resolved 1 August 2000
Lifesaving
Issued 9 May 2000
Resolved
REPAIR INFLATION TUBES ON 30 BAYLEY IMMERSION SUITS.
Condition: Unknown
Due 1 August 2000
Resolved 1 August 2000
Engineering
Issued 17 March 2000
Resolved
MAKE PERMANENT REPAIRS TO HEAVY FUEL/LIGHT FUEL BLENDING/REGULATING SYSTEM OR REMOVE SYSTEM ALTOGETHER AND RUN ON ONE TYPE OF FUEL. BLENDING/ REGULATING VALVE TO REMAIN IN JACKED-OPEN POSITION AND MONITORED UNTIL REPAIRS OR REMOVAL ACCOMPLISHED.
Condition: Unknown
Due 27 March 2000
Resolved 27 March 2000
Fire Fighting
Issued 15 June 1999
Resolved
Make permanent repairs to slow leaks in low pressure CO2 fixed system. 46 CFR 50.20-35
Condition: Unknown
Due 15 June 1999
Resolved 15 June 1999
Engineering
Issued 5 May 1998
Resolved
Fuel oil supply lines on main diesel engines are deteriorated. Replace NLT24JUL98 to the satisfaction of attending USCG marine inspector.
Condition: Unknown
Due 5 May 1998
Resolved 5 May 1998
Unknown
Issued 17 May 1996
Resolved
REPAIR AND DEMONSTRATE OPERATION OF ECHO DEPTH SOUNDING EQUIPMENT IN ACCORDANCE WITH 46 C.F.R. 96.27-1.
Condition: Unknown
Due 17 May 1996
Resolved 17 May 1996
Lifesaving
Issued 17 May 1996
Resolved
CONDUCT LIFEBOAT WEIGHT TEST ON PORT L/B IN THE PRESENCE OF CG INSPECTOR INACCORDANCE WITH 46 C.F.R. 91.25-15(a)(2)(2).
Condition: Unknown
Due 17 May 1996
Resolved 17 May 1996
Unknown
Issued 17 May 1996
Resolved
CONDUCT FIRE/BOAT DRILL PROIR TO DEPARTURE FROM THE PORT OF MOBILE, IN THE PRESENCE OF CG INSPECTOR IN ACCORDANCE WITH MSM VOL II CH 8, 6.R.3.v.
Condition: Unknown
Due 17 May 1996
Resolved 17 May 1996
Fire Fighting
Issued 18 July 1995
Resolved
REPAIR LEAK IN DECK LEVEL PIPE AT FIRE STATION 20.
Condition: Unknown
Due 18 July 1995
Resolved 18 July 1995
Fire Fighting
Issued 18 July 1995
Resolved
REPLACE AND PROPERLY INSTALL CO2 BOTTLE FOR PAINT LOCKER.
Condition: Unknown
Due 18 July 1995
Resolved 18 July 1995
Accommodation/Occupational Safety
Issued 18 July 1995
Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Unknown
Due 18 July 1995
Resolved 18 July 1995
Electrical
Issued 18 July 1995
Resolved
REPAIR EMERGENCY LIGHTS AS REQUIRED THROUGHOUT INTERIOR OF PILOTHOUSE.
Condition: Unknown
Due 18 July 1995
Resolved 18 July 1995
Unknown
Issued 18 July 1995
Resolved
PROVE PROPER OPERATION OF BOTH INDUSTRIAL FORK LIFTS AS PER 46 CFR 97.70.
Condition: Unknown
Due 18 July 1995
Resolved 18 July 1995
Fire Fighting
Issued 18 July 1995
Resolved
REPAIR OR RENEW PSI GAUGE FOR EMERGENCY FIRE PUMP.
Condition: Unknown
Due 18 July 1995
Resolved 18 July 1995
Unknown
Issued 18 July 1995
Resolved
REPAIR REAR LIGHT ON LARGE FORK LIFT.
Condition: Unknown
Due 18 July 1995
Resolved 18 July 1995
Fire Fighting
Issued 18 July 1995
Resolved
REPAIR LEAKING PACKING AT FIRE STATION 22.
Condition: Unknown
Due 18 July 1995
Resolved 18 July 1995
Lifesaving
Issued 18 July 1995
Resolved
STENCIL CAPACITY AND LIFERAFT NUMBER ON FORWARD LIFERAFT.
Condition: Unknown
Due 18 July 1995
Resolved 18 July 1995
Electrical
Issued 18 July 1995
Resolved
INSTALL AND PROVE PROPER OPERATION OF ADDITIONAL 24V BATTERY OPERATED BACK-UP LIGHTS FOR EMERGENCY LIGHTING SYSTEM IN ENGINE ROOM.
Condition: Unknown
Due 18 July 1995
Resolved 18 July 1995
Electrical
Issued 27 July 1994
Resolved
SUBMIT TO COMMANDER, MARINE SAFETY CENTER VIA [name withheld].,FOR REVIEW AND APPROVAL ADDITIONAL GENERAL ALARM PLANS (FOR CARGO HOLDS AND FWD BOS'N HOLD) PRIOR TO INSTALLATION AS PER 46 CFR 113.25 BY 27 OCT 1994.
Condition: Unknown
Due 27 December 1994
Resolved 6 February 1995
Engineering
Issued 27 July 1994
Resolved
SUBMIT FOR REVIEW AND APPROVAL TO [name withheld]., MAIN AND AUXILIARY MACHINERY AUTOMATION TEST PROCEDURES THAT COMPLY WITH THE REQUIREMENTS OF NAVIC 1-69.
Condition: Unknown
Due 27 March 1995
Resolved 6 September 1995
Documentation
Issued 27 July 1994
Resolved
SUBMIT TO [name withheld]., A COMPLETE SET OF UNSTAMPED PLANS FROM THE 1981REFLAGGING, THESE PLANS TO INCLUDE THE REQUIREMENTS OF 46 CFR 91.55-5(a)all(b)all, (e) AND (F) PRIOR TO 27JAN1995.
Condition: Unknown
Due 27 January 1995
Resolved 6 September 1995
Construction/Loadline
Issued 27 July 1994
Resolved
INSTALL AND DEMONSTRATE OPERATION OF AUTOMATIC DOOR CLOSURE DEVICES FOR THETHREE CARGO AREA VERTICAL STAIRTOWERS PRIOR TO LOADING VEHICLES OR BY 27 AUG 94.
Condition: Unknown
Due 27 August 1994
Resolved 9 September 1994
Construction/Loadline
Issued 27 July 1994
Resolved
REMOVE AND PROPERLY DISPOSE OF HYDRAULIC OIL FROM THE BOW THRUSTER ROOM BILGES BY 27AUG94. BILGES NOT TO BE PUMPED UNTIL SPACE IS CLEANED.
Condition: Unknown
Due 27 August 1994
Resolved 9 September 1994
Engineering
Issued 27 July 1994
Resolved
COMPLETE REPAIRS TO PITCH CONTROL SYSTEMS TO PREVENT FUTURE BILGE CONTAMINATION DUE TO EXCESSIVE LEAKAGE OF HYDRAULIC SYSTEM OIL. UNTIL SYSTEM HAS BEEN SATISFACTORILY REPAIRED, USE OF BILGE EDUCTOR IS RESTRICTEDTO EMERGENCIES ONLY.
Condition: Unknown
Due 27 August 1994
Resolved 9 September 1994
Fire Fighting
Issued 27 July 1994
Resolved
SUBMIT FOR REVIEW AND APPROVAL TO [name withheld]., THE FOLLOWING ITEMS PERTAINING TO THE PYROTRONICS FIRE/SMOKE DETECTION SYSTEM; OPERATIONS MANUAL, MAINTENANCE AND TESTING INSTRUCTIONS, DETAILED PLANS AS REQUIRED BY46 CFR 76.27-15.
Condition: Unknown
Due 27 August 1994
Resolved 29 July 1994
Navigation
Issued 27 July 1994
Resolved
FABRICATE AND INSTALL A STEERING GEAR REPLENISHMENT RESERVOIR THAT MEETS THE REQUIREMENTS OF SOLAS CHAP. II, REG 29.12 BY 27 AUG 94 OR PRIOR TO SAILING FOREIGN.
Condition: Unknown
Due 27 August 1994
Resolved 9 September 1994
Lifesaving
Issued 27 July 1994
Resolved
PROVIDE FOR ALL CARGO HOLDS A GENERAL ALARM SYSTEM AS REQUIRED BY 46 CFR 113.25-9. UNTIL INSTALLED, WATCHSTANDERS TO BE PROVIDED WITH PORTABLE COMMUNICATIONS DURING ROUNDS AND GENERAL CARGO OPERATIONS UNTIL INSTALLED TO THE SATISFACTION OF THE ATTENDING CG MARINE INSPECTOR IAW APPV'D PLANS.
Condition: Unknown
Due 27 December 1994
Resolved 6 February 1995
Documentation
Issued 27 July 1994
Resolved
FORWARD COPIES TO [name withheld]., COPIES OF VESSELS ABS ISSUED SAFETY CONSTRUCTIONCERTIFCATE AND SAFETY CARGO GEAR CERTIFICATE.
Condition: Unknown
Due 27 August 1994
Resolved 9 September 1994
Documentation
Issued 25 August 1990
Resolved
Vessel with the capacity of 250 or more barrels of oil entered US port without a proper oil transfer procedures as required by 33 CFR 155.720_x001C_ _x001C_ _x001C_
Condition: Unknown
Due 17 September 1992
Resolved 17 September 1992
Navigation
Issued 25 August 1990
Resolved
Vessel over 1600 gross tons failed to have on board simple operating instructions with block diagrams showing change over procedures for remote steering gear systems._x001C_ _x001C_
Condition: Unknown
Due 17 September 1992
Resolved 17 September 1992
Navigation
Issued 25 August 1990
Resolved
Vessel over 1600 gross tons failed to conduct and log pre-arrival test prior to entering US Navigable waters as required by 33 CFR 164.11 _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 25 August 1990
Resolved 25 August 1990
Navigation
Issued 25 August 1990
Resolved
Vessel over 1600 gross tons entered US port Savannah, GA without a current corrected copy of the Tidal Current Tables for this area. A violation of 33CFR 164.33_x001C_ _x001C_
Condition: Unknown
Due 25 August 1990
Resolved 25 August 1990
Electrical
Issued 5 December 1988
Resolved
INVESTIGATE THE CAUSE OF THE DEAD GROUND IN THE 24 VOLT SYSTEM AND MAKE REPAIRS AS NECESSARY.
Condition: Unknown
Due 5 December 1988
Resolved 5 December 1988
Electrical
Issued 5 December 1988
Resolved
REPLACE THE BATTERIES FOR THE 24 VOLT SYSTEM AS ORIGINAL.
Condition: Unknown
Due 5 December 1988
Resolved 5 December 1988
Electrical
Issued 10 October 1988
Resolved
MAKE PERMANENT REPAIRS TO EMERGENCY GENERATOR CONTROL BOARD RELAY TR4 (AUTO ELECTRIC START SYSTEM)
Condition: Unknown
Due 10 October 1988
Resolved 10 October 1988
Navigation
Issued 13 January 1988
Resolved
UPON ARRIVAL SAVANNAH, GA AND PRIOR TO DEPARTURE, MAKE PERMANENT REPAIRS TOTHE RADAR SCANNER FOR THE 10CM RADAR UNIT. UPON COMPLETION/PROVE SATISFAC- TORY OPERATION TO A USCG MARINE INSPECTOR.
Condition: Unknown
Due 13 January 1988
Resolved 13 January 1988
Lifesaving
Issued 15 August 1987
Resolved
CONDUCT A WEIGHT TEST OF THE PORT LIFEBOAT.
Condition: Unknown
Due 15 August 1987
Resolved 15 August 1987
Fire Fighting
Issued 17 March 1985
Resolved
STENCIL PORT AND STARBOARD SIDE MAIN DECK ENGINE ROOM ESCAPE HATCHES, "ENGINE ROOM ESCAPE HATCH."
Condition: Unknown
Due 17 March 1985
Resolved 17 March 1985
Accommodation/Occupational Safety
Issued 17 March 1985
Resolved
REPAIR BELT GUARD ON #2 AIR CONDITIONING REEFER COMPRESSOR.
Condition: Unknown
Due 17 March 1985
Resolved 17 March 1985
Fire Fighting
Issued 17 March 1985
Resolved
PROVE SATISFACTORY OPERATION OF FORWARD STARBOARD FIRE DAMPNER ON 01 DECK.
Condition: Unknown
Due 17 March 1985
Resolved 17 March 1985
Construction/Loadline
Issued 17 March 1985
Resolved
MAKE PERMANENT REPAIRS TO BALLAST LINE IN WAY OF 101 BALLAST VALVE. THIS LINE IS NOT TO BE USED UNTIL PERMANENT REPAIRS ARE COMPLETED EXCEPT IN EMERGENCY.
Condition: Unknown
Due 17 March 1985
Resolved 17 March 1985
Fire Fighting
Issued 17 March 1985
Resolved
REPOSITION HYDRANT OR HOSE RACK AT FIRE STATION #50 SO FIRE HOSE CAN BE ATTACHED TO HYDRANT AT ALL TIMES.
Condition: Unknown
Due 17 March 1985
Resolved 17 March 1985
Fire Fighting
Issued 16 October 1984
Resolved
PROVE OPERATION OF ITEM F1(B) ON AUTOMATION CHECK-OFF LIST.
Condition: Unknown
Due 16 October 1984
Resolved 16 October 1984
Unknown
Issued 16 October 1984
Resolved
PROVIDE UPDATED INSTRUCTION MANUAL FOR OILY WATER SEPARATOR.
Condition: Unknown
Due 16 October 1984
Resolved 16 October 1984