Inspection history · 142
2 February 2018
Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6349911
1 February 2018
PII Safety Exam · Reflagging & Initial Certification
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6346430
20 January 2017
Deficiency Check · Examination of Repairs
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6074459
24 October 2016
Annual Inspection · MARPOL Annex I Examination
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6022438
18 March 2016
Administrative Inspection · Damage Survey
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 5836189
28 November 2015
Deficiency Check · Damage Survey · Examination of Repairs
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 5772691
13 November 2015
Deficiency Check · Damage Survey
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 5763088
10 June 2015
Administrative Inspection · Internal Structural Exam · Cargo Tank Internal · COI Inspection · Examination of Repairs · In-Service Inspection · MARPOL Annex I Examination
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 5149711
17 November 2014
Type not recorded
No type recorded · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 5025293
29 July 2014
MARPOL Annex I Examination · Annual Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 4932212
5 October 2013
Type not recorded
No type recorded · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 4730386
9 August 2012
Annual Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 4403110
20 December 2011
Damage Survey
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 4211556
15 July 2011
Examination of Repairs · Deficiency Check
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 4082423
12 July 2011
Damage Survey · Permit to Proceed
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 4078902
20 June 2011
Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 4055110
19 April 2010
Drydock Exam · Internal Structural Exam · Administrative Inspection · Hull Examination · MARPOL Annex I Examination · Examination of Repairs · COI Inspection · Cargo Tank Internal
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 3720518
5 April 2010
MARPOL Annex VI Survey
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3707844
25 March 2010
Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3702824
19 March 2010
Examination of Repairs · Annual Inspection
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3700226
2 March 2009
Deficiency Check
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3426758
15 February 2009
Administrative Inspection · Damage Survey
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 3427361
14 February 2009
Type not recorded
No type recorded · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 3418773
26 January 2009
Type not recorded
No type recorded · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 3434960
12 December 2008
Administrative Inspection · DAPI Audit · MARPOL Annex II Examination · Internal Structural Exam · Periodic Inspection · MTSA/ISPS Verification
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 3378729
12 March 2008
Annual Inspection · MTSA Verification
Physical examination · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 3164454
30 July 2007
Type not recorded
No type recorded · Marine Safety Unit Galveston · USCG Heartland District (CGD-H) · Activity 3013533
27 February 2007
Annual Inspection · MTSA Verification
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 2878387
12 December 2006
Type not recorded
No type recorded · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 2840290
11 April 2006
Type not recorded
No type recorded · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 2622503
1 November 2005
Cargo Tank Internal · Administrative Inspection · MARPOL Annex I Examination · COI Inspection · Internal Structural Exam · Hull Examination
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 2526549
15 May 2005
Annual Inspection · MTSA Verification
Physical examination · MIDET EAST BANK DETAIL · USCG Heartland District (CGD-H) · Activity 2358111
26 October 2004
Security Plan Amendment Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2228563
28 July 2004
Type not recorded
No type recorded · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 2148386
27 July 2004
Administrative Inspection
Administrative · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 2146815
27 July 2004
In-Service Inspection
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 2147201
10 May 2004
Examination of Repairs
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 2063680
17 February 2004
Security Plan Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2016380
19 December 2003
Examination of Repairs
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1967318
12 December 2003
Security Plan Review - ASP
Administrative · Marine Safety Center (MSC) · Activity 1980838
14 November 2003
Internal Structural Exam · Annual Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1947891
29 July 2003
Administrative Inspection
Administrative · MIDET EAST BANK DETAIL · USCG Heartland District (CGD-H) · Activity 1860539
20 March 2003
Deficiency Check
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1759410
27 January 2003
MARPOL Annex I Examination · Annual Inspection
Physical examination · MIDET WEST DETAIL · USCG Heartland District (CGD-H) · Activity 1736084
24 September 2002
Deficiency Check
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1680067
20 February 2002
Annual Inspection
Physical examination · MSU LAKE CHARLES · USCG Heartland District (CGD-H) · Activity 1487691
14 November 2001
Examination of Repairs
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1076408
26 July 2001
Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 30668
27 January 2001
Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 189586
27 January 2001
Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 769466
22 December 2000
COI Inspection · Hull Examination
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1415284
27 August 1999
Deficiency Check
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 781840
26 July 1999
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 770669
5 June 1999
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 199211
4 September 1998
Hull Examination · COI Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1455628
23 June 1998
Administrative
Administrative · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1128971
12 May 1998
Examination of Repairs
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1125216
10 December 1997
Deficiency Check
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 780416
6 December 1997
Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 410735
3 December 1997
Re-Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1388416
8 October 1997
Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 436339
6 June 1997
Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 469711
30 January 1997
Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 499299
19 October 1996
Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 493912
8 October 1996
Deficiency Check
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1153630
7 October 1996
COI Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 840724
30 September 1996
Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 57256
6 August 1996
Administrative
Administrative · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1092174
15 April 1996
Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 451132
2 January 1996
Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 451492
23 December 1995
Deficiency Check · Hull Examination
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1422619
6 October 1995
Re-Inspection
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1459958
4 September 1995
Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 6437
16 August 1995
Type not recorded
No type recorded · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 453808
24 April 1995
Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 378022
8 April 1995
Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 60097
13 March 1995
Administrative
Administrative · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 865229
24 February 1995
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 642978
20 February 1995
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 68258
14 December 1994
Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1146218
14 December 1994
Deficiency Check
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1150107
4 December 1994
Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 461754
6 October 1994
COI Inspection
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1411036
3 August 1994
Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 54352
6 June 1994
Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 482382
8 December 1993
Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 525029
18 October 1993
Re-Inspection
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 839889
9 August 1993
Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 642975
4 August 1993
Hull Examination
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1379836
23 July 1993
Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 158755
13 June 1993
Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 532439
14 May 1993
Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 47563
26 April 1993
Damage Survey
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1142497
25 April 1993
Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 82455
12 March 1993
Deficiency Check
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 842059
15 November 1992
Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 354468
9 November 1992
Deficiency Check
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 963176
4 November 1992
Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 458374
4 November 1992
Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 465809
20 October 1992
COI Inspection
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 961842
27 June 1992
Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 351804
22 April 1992
Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 453992
27 December 1991
Deficiency Check
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 961118
23 December 1991
Type not recorded
No type recorded · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 503084
20 December 1991
Deficiency Check
Physical examination · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 1265194
13 December 1991
Administrative
Administrative · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1258933
22 November 1991
Re-Inspection
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1436675
1 October 1991
Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 474425
14 March 1991
Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 503321
8 February 1991
Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 507327
8 November 1990
COI Inspection · Hull Examination
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 907806
3 October 1990
Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 929147
12 June 1990
Re-Inspection
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 929263
16 April 1990
Deficiency Check
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1223982
5 April 1990
Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 525414
31 March 1990
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1211510
4 January 1990
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1236416
20 October 1989
Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 539390
11 October 1989
Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 494586
12 June 1989
COI Inspection
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1202726
9 March 1989
Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 452234
17 August 1988
Administrative
Administrative · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1349290
16 August 1988
Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 485915
15 July 1988
Deficiency Check
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 902148
24 June 1988
Deficiency Check
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1204447
17 June 1988
Hull Examination · Re-Inspection
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 895157
10 September 1987
Drydock Extension
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1311994
19 June 1987
Type not recorded
No type recorded · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 476282
12 June 1987
COI Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1010491
12 June 1987
MARPOL Annex II Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1319471
12 December 1986
Type not recorded
No type recorded · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 494492
30 June 1986
Type not recorded
No type recorded · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 509302
18 June 1986
Re-Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 984901
8 January 1986
Type not recorded
No type recorded · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 459916
4 December 1985
Deficiency Check
Physical examination · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 1295688
20 November 1985
Damage Survey
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 993944
7 November 1985
Credit Drydock
Administrative · MSO Mobile · USCG Heartland District (CGD-H) · Activity 993690
23 September 1985
COI Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1298636
2 July 1985
Deficiency Check
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1287001
27 June 1985
Initial Certification
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 985312
12 March 1985
Type not recorded
No type recorded · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 480946
7 September 1984
Type not recorded
No type recorded · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 540508
Deck/Cargo › Holds/Tanks › Bulkhead
Issued 1 February 2017
Resolved
Vessel authorized to conduct commercial operations NOLA COTP zone until 01MAR2017. At which time directed to proceed to repair facility to complete repairs as per repair proposal dated 27JAN2017.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 18 March 2017
Resolution: All repairs completed as per approved repair plan, USCG & ABS witnessed fitup and testing. All repairs are approved by ABS & local USCG MI.
Operations/Management › Vessel Activity › Other
Issued 1 February 2017
Resolved
Vessel is authorized to operate in the LMR in support of refinery operations.21FEB company shall notify the CG of the intended Repair facility, and on 01mar is directed to transit to that repair facility to conduct permenanet repairs.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 1 March 2017
Resolved 1 March 2017
Resolution: Vessel currently at [name withheld]. Wharf awaiting permanent repairs.
Operations/Management › Vessel Activity › Other
Issued 31 January 2017
Resolved
Operating request till 28FEB17 is authorized. Outlined reporting requirements during operational period. Repairs are outstanding.
Condition: Invalid
Action required: 705 - Other - as specified
Due 28 February 2017
Resolved 1 March 2017
Resolution: Vessel completed authorized local operational period. Vessel currently at [name withheld]. wharf. Boland Marine to conduct repairs.
Deck/Cargo › Holds/Tanks › Bulkhead
Issued 25 January 2017
Resolved
Cargo tk exterior material condition is extremely poor. Required gauging report as indiacted in attachments. See 835 dated 25 Jan 2017.
Action required: 705 - Other - as specified
Resolved 30 January 2017
Resolution: Rcvd Gauging report & repair proposal
Deck/Cargo › Holds/Tanks › Bulkhead
Issued 23 January 2017
Resolved
While conducting company internal inspection, vessel rep found the port #8 cargo tank
cargo sideshell plate severely wasted, rusted and leaking cargo. Wastage is located port
side on the exterior of the cargo tank approx. 20 ft below the main deck at frame 31. The
wastage is along the weldment of the swash bulkhead to the cargo tank. Prior to cargo
operations. Crop and renew to good metal
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 24 January 2017
Resolution: ABS approved repair proposal and repairs, air tested sat.
Deck/Cargo › Holds/Tanks › Bulkhead
Issued 23 January 2017
Resolved
While conducting company internal inspection, vessel rep found the port #6 cargo tank
cargo sideshell plate severely wasted, rusted and leaking cargo. Wastage is located port
side on the exterior of the cargo tank approx. 20 ft below the main deck at frame 24. The
wastage is along the weldment of the swash bulkhead to the cargo tank. Prior to cargo
operations. Crop and renew to good metal
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 24 January 2017
Resolution: ABS approved repair proposal and repairs, air tested sat.
Deck/Cargo › Holds/Tanks › Bulkhead
Issued 23 January 2017
Resolved
Port side, #6 cargo tank exterior has significant blistering and metal degradation.
Provide thickness gauging report to the Coast Guard on the exterior of #6 cargo tank in
the specific areas identified onboard and make available to the Coast Guard for
inspection.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 30 January 2017
Resolution: Rcvd gauging report and repair proposal.
Deck/Cargo › Holds/Tanks › Bulkhead
Issued 18 March 2016
Resolved
The #1 Port Ballast Tank has a fracture within the #2 Cargo tank & frame weldment. Fracture has been permanently repaired with an insert. Air tested, all sat.
Condition: Damaged By Earlier Event
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 18 March 2016
Deck/Cargo › Holds/Tanks › Bulkhead
Issued 18 March 2016
Resolved
While repairing a fracture within the #1 Port Ballast tank & the #1 Cargo tank a pin hole was created between the #1 Cargo & #1 Port Ballast tank. Crop & renew with insert prior to conducting cargo operations within the #1 Cargo tank or utilizing the #1 Ballast Tank.
Condition: Damaged By Earlier Event
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 20 March 2016
Construction/Loadline › Hull › Hull Plating
Issued 28 November 2015
Resolved
Port Stern void was flooded to the waterline
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 9 December 2015
Resolution: Shipyard replaced sections of wasted sideshell and internal framing. Cause appeared to be damage from prior flooding of the space, steel eating bacteria, and an improperable impressed current system.
Construction/Loadline › Hull › Hull Plating
Issued 13 November 2015
Resolved
Unknown location of hole in starboard stern void. Approximately 16 ft of water in the void.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 12 December 2015
Resolved 16 November 2015
Resolution: 18" X 18" insert placed in stern void of the barge renewed plate that had three pinhole leaks. Insert and pressure test oberserved and cleared by ABS inspector.
Construction/Loadline › Hull › Hull Plating
Issued 10 June 2015
Resolved
De-scale ballast tanks/voids to make available for inspection throughout the vessel. Provide
gauge report of steel in ballast tanks/voids and overhead of cargo tanks. 46 CFR 31.10-21
Condition: Damaged By Earlier Event
Action required: 17 - Rectify deficiencies prior to departure
Due 22 October 2015
Resolved 22 October 2015
Resolution: Localized descaling accepted, Q-Sea report attesting to steel thickness provied. Barge approved for NVIC 10-82 under ABS supervision for reduction in scantling with strengthening of rider plates along tank top longitudinals.
Construction/Loadline › Hull › Longitudinal Frame
Issued 10 June 2015
Resolved
Crop and renew all wasted longitudinals in ballast tanks/voids throughout the vessel.
46 CFR 31.10-21
Condition: Damaged By Earlier Event
Action required: 17 - Rectify deficiencies prior to departure
Due 22 October 2015
Resolved 22 October 2015
Resolution: All longitudinals replaced with new.
Construction/Loadline › Hull › Hull Plating
Issued 10 June 2015
Resolved
Crop and renew hull plating on anchor pocket due to severe wastage (holes) in steel. 46 CFR 31.10-21
Condition: Damaged By Earlier Event
Action required: 17 - Rectify deficiencies prior to departure
Due 22 October 2015
Resolved 22 October 2015
Resolution: All hull plating replaced with new.
Deck/Cargo › Ballast › Tank
Issued 10 June 2015
Resolved
Replace ladder rungs and posts in ballast tanks throughout the vessel. 46 CFR 31.10-21
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 22 October 2015
Resolved 22 October 2015
Resolution: All ladder rungs and posts replaced with new.
Deck/Cargo › Ballast › Tank
Issued 10 June 2015
Resolved
Replace deck grating under ladder in # 3 & 4 ballast tank starboard side & all cargo tanks. 46 CFR 31.10-21
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 22 October 2015
Resolved 22 October 2015
Resolution: All grating replaced with new.
Deck/Cargo › Holds/Tanks › Ullage
Issued 10 June 2015
Resolved
Replace all wasted striker plates for sounding tubes in tanks # 3 & 4 on starboard ballast.
Condition: Damaged By Earlier Event
Action required: 17 - Rectify deficiencies prior to departure
Due 22 October 2015
Resolved 22 October 2015
Resolution: Striking plate renewed.
Construction/Loadline › Hull › Hull Plating
Issued 10 June 2015
Resolved
Crop and renew crack in swash bulkhead in tank #3 starboard, in bay 2 of forward bulkhead. 46 CFR 31.10-21
Condition: Damaged By Earlier Event
Action required: 17 - Rectify deficiencies prior to departure
Due 22 October 2015
Resolved 22 October 2015
Resolution: Swash bulkhead replaced with new.
Deck/Cargo › Holds/Tanks › Liquid Level Gaging
Issued 29 July 2014
Resolved
#2S and #7S high level alarms are inoperable. Barge must prove proper operation of inoperable alarms prior to loading of cargo in subject tanks.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 31 July 2014
Resolution: Received tech report confirming the repair and proper functioning of the #2S and #7S high level alarm
Engineering › Diesel Engine (auxiliary) › Overspeed Device
Issued 9 August 2012
Resolved
Overspeed device on the #2, #3 and #4 cargo pumps not operational as required by 46 CFR 111.01-12(b). Prove proper operation of overspeed device function.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 9 September 2012
Resolved 14 September 2012
Resolution: Master provided documentation with his license number attesting to the proper operation of the overspeed trips.
Engineering › Diesel Engine (auxiliary) › Emergency shutdown
Issued 9 August 2012
Resolved
Low lube oil shutdowns on the #1, #2, and #3 generators non-functional as required by 46 CFR 111.12-1(c). Prove proper operation.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 9 September 2012
Resolved 14 September 2012
Resolution: Master provided documentation with his license number attesting to the proper operation of the low lube oil alarms.
Deck/Cargo › Holds/Tanks › Independent Tank
Issued 20 December 2011
Resolved
Vsl has a pinhole leak in the #1 Cargo tank.
Action required: 701 - Prior to carriage of passengers/cargo
Due 20 January 2012
Resolved 29 December 2011
Resolution: Received, reviewed, and approved ABS class report attesting to proper repairs. Cropped and renewed affected area and conducted satisfactory airtest.
Deck/Cargo › Holds/Tanks › Bulkhead
Issued 18 July 2011
Resolved
Crop and renew wasted section of #9 Starboard cargo tank aft envelop IAW ABS condition of class.
Action required: 705 - Other - as specified
Due 18 July 2011
Resolved 18 August 2011
Deck/Cargo › Cargo Stowage › General
Issued 12 July 2011
Resolved
Repair pinhole iwo aft outboard corner of #9 stbd cargo tank
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 18 July 2011
Deck/Cargo › Cargo Stowage › General
Issued 12 July 2011
Resolved
Survey area of aft bulkhead of # 9 stbd cargo tank above the main deck and provide results to the cognizant OCMI.
Due 12 August 2011
Resolved 18 July 2011
Documentation › Certificates/Documents › Certificate of Inspection
Issued 19 March 2010
Resolved
Rcvd call requesting annual inspection. Met with vessel rep and discussed the scope of the exam. This is a 30yr old oceans route ITB tank barge 'D' certified for Grade 'A' and lower cargos. Prior to conducting the inspection verified: MISLE vessel details, COFR, VRP, COI, CAA. Vessel failed to conduct annual inspection within anniversary allotted time and was issued a NOV.
Action required: 705 - Other - as specified
Resolved 19 March 2010
Resolution: Endorsed annual USCG certificates and COI. Inspection complete. On 19Mar10 the vessel was in satisfactory condition for the route and service listed on the COI.
Deck/Cargo › Cargo Heating › General
Issued 15 February 2009
Resolved
Make ALL needed repairs to the stbd. thermal fluid heater by a qualified Volcanic repair technician and provide a repair report to the CG prior to placing back into service.
Action required: 705 - Other - as specified
Resolved 2 March 2009
Accommodation/Occupational Safety › Refrigeration (air conditioning) › General
Issued 29 January 2009
Resolved
A/C unit on barge is not intrinsically safe.
Action required: 17 - Rectify deficiencies prior to departure
Due 1 March 2009
Resolved 6 February 2009
Documentation › Manuals/Policy Documentation › Transfer Procedures
Issued 29 January 2009
Resolved
Transfer procedures must be updated to include the newly installed MARCON overfill protection system.
Due 1 March 2009
Resolved 2 February 2009
Deck/Cargo › Holds/Tanks › Ventilation Exhaust Outlet
Issued 29 January 2009
Resolved
Port and Stbd aft rake goosenecks were missing there internal parts (i.e. check valve and screen).
Action required: 17 - Rectify deficiencies prior to departure
Due 1 March 2009
Resolved 2 February 2009
Engineering › Diesel Engine (auxiliary) › Overspeed Device
Issued 15 May 2005
Resolved
Overspeed device on #1 Ship service generator inop.
Condition: Improper/Lack of Maintenance
Due 15 June 2005
Resolved 15 May 2005
Engineering › Diesel Engine (auxiliary) › Valve
Issued 15 May 2005
Resolved
Cargo pump engine RPM gauge found inoperative.
Condition: Improper Installation
Due 15 June 2005
Resolved 20 June 2005
Documentation › Certificates/Documents › Certificate of Inspection
Issued 15 May 2005
Resolved
Vessel operated outside the annual inspection date for nearly two months before scheduling an inspection.
Condition: Improper/Lack of Maintenance
Due 15 May 2005
Resolved 16 May 2005
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Cargo Pump
Issued 27 July 2004
Resolved
REPAIR LEAKS ON FORWARD PORT PRIME MOVER.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 3 August 2004
Resolved 15 May 2005
Deck/Cargo › Vapor Control Systems › Piping/Hoses
Issued 27 July 2004
Resolved
PROPERLY LABEL VAPOR RECOVERY SYSTEM PIPING.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 3 August 2004
Resolved 15 May 2005
Resolution: Vapor Recovery system Inoperative, until vessel changes designated cargo.
Electrical › Electric Supply System (service) › Battery Installation
Issued 27 July 2004
Resolved
PROPERLY STOW BATTERIES IN STARBOARD AFT GENERATOR SPACE.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 3 August 2004
Resolved 15 May 2005
Documentation › Certificates/Documents › Safety Management Certificate (ISM)
Issued 27 July 2004
Resolved
VESSEL IS PROHIBITED FROM CONDUCTING CARGO OPERATIONS UNTIL VALID ISM DOCUMENTS ARE ISSUED BY AN APPROVED AUHTORITY TO THE SATISFACTION OF THE FLAG ADMINISTRATION.
Condition: Unknown
Action required: 705 - Other - as specified
Due 3 August 2004
Resolved 15 May 2005
Engineering › Diesel Engine (auxiliary)
Issued 27 January 2003
Resolved
Prove proper operation of #1 and #2 cargo pump engine emergency shut down.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 27 April 2003
Resolved 20 March 2003
Electrical › Electrical Distribution System (service)
Issued 27 January 2003
Resolved
Properly replace open circuit spaces with blank out pieces on ENG HTR PWR PNL. LEGACY COMPONENT DESC: Distribution Panel Bus
Condition: Improper/Lack of Maintenance
Due 27 April 2003
Resolved 20 March 2003
Electrical › Electrical Distribution System (service)
Issued 27 January 2003
Resolved
Properly replace all wrong amp breakers with correct size on AFT LTG PNL ALD1. LEGACY COMPONENT DESC: Distribution Panel Bus
Condition: Improper Installation
Due 27 April 2003
Resolved 20 March 2003
Engineering › Diesel Engine (auxiliary)
Issued 27 January 2003
Resolved
Replace and reblanket #4 cargo pump engine exhaust manifold. Prove proper operation of all gauges. Tighten leg mount on shaft guard.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 27 April 2003
Resolved 20 March 2003
Electrical › Electrical Distribution System (service)
Issued 27 January 2003
Resolved
Ensure all breaker panel amps are of the proper size and labeled correctly. LEGACY COMPONENT DESC: Circuit Breaker
Condition: Improper/Lack of Maintenance
Due 27 April 2003
Resolved 20 March 2003
Electrical › Electric Generation Source (service)
Issued 20 February 2002
Resolved
Place electrical matting behind switchboard in generator room. LEGACY COMPONENT DESC: Panelboard
Due 20 February 2002
Resolved 20 February 2002
Resolution: Crew installed electrical matting
Deck/Cargo › Cargo Transfer/Lightering (liquid)
Issued 20 February 2002
Resolved
No record of annual test for cargo system relief valves, gages, hoses, or piping. Issued requirement to test system to 100% MAWP at next cargo transfer.
Due 20 April 2002
Resolved 25 September 2002
Resolution: MSO Tampa Marine Inspections Department received letter dated 05Apr02 from Boland Marine (via Penn Maritime fax) attesting to the above mentioned tests as being conducted satisfactorily IAW 100% MAWP requirement.
Deck/Cargo › Cargo Transfer/Lightering (liquid)
Issued 20 February 2002
Resolved
No record of annual test of cargo system piping, hoses, relief valves, or gages. Issued requirement to test these items to 150% MAWP prior to or in conjunction with their next annual or periodic inspection
Due 20 February 2003
Resolved 25 September 2002
Resolution: MSO Tampa Marine Inspections Department received letter dated 05Apr02 from Boland Marine (via Penn Maritime fax) attesting to the above mentioned tests as being conducted satisfactorily IAW 150% MAWP requirement.
Lifesaving
Issued 14 November 2001
Resolved
MISSING TWO FLAME SCREENS.
Condition: Unknown
Due 30 November 2001
Resolved 20 February 2002
Resolution: Crew renewed flame screens.
Deck/Cargo
Issued 14 November 2001
Resolved
HYDRAULIC LINE AND PLATING LEAKING.
Condition: Unknown
Due 30 November 2001
Resolved 20 February 2002
Resolution: Third party contractor replced slipring coupling.
Construction/Loadline
Issued 4 September 1998
Resolved
COMPLETE ENHANCED SURVEY REQUIREMENTS AS PER NVIC 2-97 & 33 CFR 157.430._x001C_ (NOTE): THIS REQUIREMENT IS WAIVED SHOULD THIS VESSEL COMMENCE A DOUBLE- HULL CONVERSION WITHIN THIS TIME FRAME.
Condition: Unknown
Due 4 September 1998
Resolved 4 September 1998
Deck/Cargo
Issued 3 December 1997
Resolved
MAKE ALL TANK CLOSURES AND P/V VALVES AVAILABLE FOR INSPECTION._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 3 December 1997
Resolved 3 December 1997
Deck/Cargo
Issued 3 December 1997
Resolved
PROVE PROPER OPERATION OF #2 AND #3 CARGO PUMP EMERGENCY SHUTDOWNS PRIOR TOOPERATING THE PUMPS.
Condition: Unknown
Due 3 December 1997
Resolved 3 December 1997
Construction/Loadline
Issued 3 December 1997
Resolved
PROPERLY REPAIR WATERTIGHT DOOR AND HATCH COVER AT BOW VOID._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 3 December 1997
Resolved 3 December 1997
Electrical
Issued 7 October 1996
Resolved
Replace missing covers over batteries in generator space (port aft).
Condition: Unknown
Due 9 October 1996
Resolved 9 October 1996
Engineering
Issued 7 October 1996
Resolved
Prove proper operation of bow thruster engine shutdowns (low lube oil pressure, overspeed).
Condition: Unknown
Due 31 October 1996
Resolved 13 November 1996
Deck/Cargo
Issued 7 October 1996
Resolved
Prove proper operation of number 1, 2, and 3 cargo pump engine emergency shutdowns.
Condition: Unknown
Due 9 October 1996
Resolved 9 October 1996
Deck/Cargo
Issued 7 October 1996
Resolved
Prove proper operation of number 1 cargo pump engine overspeed trip.
Condition: Unknown
Due 9 October 1996
Resolved 9 October 1996
Deck/Cargo
Issued 6 October 1995
Resolved
Prove proper operation of or remove from vessel, Bow thruster engine.
Condition: Unknown
Due 6 October 1995
Resolved 6 October 1995
Documentation
Issued 14 December 1994
Resolved
PLACE ON BAORD VESSEL THE SHIPBOARD OIL POLLUTION EMERGENCY PLAN REQUIRED BY MARPOL 73/78 ANNEX I REGULATION 26, IOPP FORM B ITEM 8 AFTER OBTAINING APPROVAL FROM COMMANDANT (G-MEP)._x001C_ _x001C_
Condition: Unknown
Due 14 December 1994
Resolved 14 December 1994
Engineering
Issued 6 October 1994
Resolved
Test emergency remote shut down for bow thruster engine, insure engine stops completely.
Condition: Unknown
Due 6 October 1994
Resolved 6 October 1994
Deck/Cargo
Issued 20 October 1992
Resolved
REPLACE UNAPPROVED PUSH ON TYPE HOSE FITTINGS ON THE FUEL OIL LINES OF THE BOW THRUSTER ENGINE.
Condition: Unknown
Due 20 October 1992
Resolved 20 October 1992
Deck/Cargo
Issued 20 October 1992
Resolved
CONNECT SUPPORT STRAP ON VENTILATION DUCTING IN BOW THRUSTER ROOM.
Condition: Unknown
Due 20 November 1992
Resolved 16 November 1992
Engineering
Issued 20 October 1992
Resolved
REPLACE TURBO INTAKE HOSE CLAMPS ON BOW THRUSTER ENGINE.
Condition: Unknown
Due 20 October 1992
Resolved 20 October 1992
Engineering
Issued 20 October 1992
Resolved
REPLACE WASTED SUPPORT BRACKET FOR EXHAUST SYSTEM (MUFFLER) ON #1 CARGO PUMP.
Condition: Unknown
Due 20 November 1992
Resolved 16 November 1992
Deck/Cargo
Issued 20 October 1992
Resolved
COVER OVERSPEED TERMINALS ON BOW THRUSTER ENGINE.
Condition: Unknown
Due 20 November 1992
Resolved 16 November 1992
Deck/Cargo
Issued 20 October 1992
Resolved
REPLACE RELIEF VALVE ON BARGE AIR RECIEVER. ENSURE THAT VALVE IS PROPERLY TAGGED.
Condition: Unknown
Due 20 October 1992
Resolved 20 October 1992
Deck/Cargo
Issued 20 October 1992
Resolved
REPLACE TEMPERATURE REGULATING VALVE ON BOW THRUSTER REDUCTION GEAR.
Condition: Unknown
Due 20 October 1992
Resolved 20 October 1992
Construction/Loadline
Issued 20 October 1992
Resolved
AJUST PACKING ON THE WASH DOWN PUMP, LOCATED IN BOW THRUSTER ROOM BILGE, TOSLOW WATER DRIP.
Condition: Unknown
Due 20 November 1992
Resolved 16 November 1992
Deck/Cargo
Issued 20 October 1992
Resolved
REPLACE MISSING ELECTRICAL BOX COVER ON BOW THRUSTER ENGINE. LOCATED ON FORWARD PART OF ENGINE OUTBOARD.
Condition: Unknown
Due 20 November 1992
Resolved 16 November 1992
Deck/Cargo
Issued 20 October 1992
Resolved
AJUST #2 CARGO PUMP OVERSPEED.
Condition: Unknown
Due 20 November 1992
Resolved 16 November 1992
Deck/Cargo
Issued 20 October 1992
Resolved
REPLACE MISSING HEATSHEILD ON AFT RACOR FILTER ON THE #1 CARGO PUMP ENGINE.
Condition: Unknown
Due 20 November 1992
Resolved 16 November 1992
Deck/Cargo
Issued 22 November 1991
Resolved
MAKE PERMANENT REPAIRS TO CHAIN LOCKER EDUCTOR REACH ROD.
Condition: Unknown
Due 13 December 1991
Resolved 13 December 1991
Deck/Cargo
Issued 22 November 1991
Resolved
MAKE PERMANENT REPAIRS TO TURBOCHARGER/ EXHAUST FLANGE LEAKS ON PUMP ENGINE#2 AND #4._x001C_
Condition: Unknown
Due 22 November 1991
Resolved 22 November 1991
Deck/Cargo
Issued 22 November 1991
Resolved
MAKE PERMANENT REPAIRS TO WASTED TANK FLANGE ON FUEL RETURN PIPING.
Condition: Unknown
Due 22 November 1991
Resolved 22 November 1991
Deck/Cargo
Issued 22 November 1991
Resolved
RENEW TURBOCHARGER OIL SUPPLY FLEX LINES ON PUMP ENGINE #2.
Condition: Unknown
Due 22 November 1991
Resolved 22 November 1991
Electrical
Issued 22 November 1991
Resolved
INSTALL APPROVED CABLE CLAMPS ON GENERATOR AND PORT AND STARBOARD HYDRAULICSTARTING BATTERIES.
Condition: Unknown
Due 22 November 1991
Resolved 22 November 1991
Deck/Cargo
Issued 22 November 1991
Resolved
PROVIDE HEAT SHIELDING ON TURBOCHARGER OIL SUPPLY LINES FLEX-HOSES ON PUMP ENGINES #1 THRU #4._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 22 November 1991
Resolved 22 November 1991
Deck/Cargo
Issued 22 November 1991
Resolved
MAKE PERMANENT REPAIRS TO DIESEL FUEL SEEPAGE ON WELD AT ELBOW OF DIESEL FUEL FILL LINE BELOW CUT-OFF VALVE TO MANIFOLD.
Condition: Unknown
Due 22 November 1991
Resolved 22 November 1991
Deck/Cargo
Issued 22 November 1991
Resolved
REPACK THRU-DECK PACKING GLANDS FOR TANK VALVES- 4S,5P,6P/S,7P/S, AND 8P/S_x001C_STRIPPING VALVES- 6S AND 7P, BLOCK VALVES- 8P AND 6P, AND PUMP SUCTION #4 AND #3.
Condition: Unknown
Due 22 November 1991
Resolved 22 November 1991
Deck/Cargo
Issued 12 June 1990
Resolved
REMOVE NON-METALLIC FLEXIBLE HOSE FOR HYDRAULIC RETURN LINE AT #7 CARGO TANK ON MAIN DECK AND REPLACE WITH STEEL PIPING.
Condition: Unknown
Due 12 June 1990
Resolved 12 June 1990
Electrical
Issued 12 June 1990
Resolved
REMOVE TEMPORARY REPAIRS AND MAKE PERMANENTS REPAIRS TO GENERATOR DAY TANK SUPPLY LINE.
Condition: Unknown
Due 12 June 1990
Resolved 12 June 1990
Electrical
Issued 12 June 1990
Resolved
RE-ATTACH WIRE RUN BRACKETS TO PORT SIDE OF BOW THRUSTER ACCESS WAY.
Condition: Unknown
Due 12 June 1990
Resolved 12 June 1990
Deck/Cargo
Issued 12 June 1990
Resolved
INSTALL OPEN/CLOSE INDICATORS ON ALL THROUGH DECK VALVE REACH RODS.
Condition: Unknown
Due 12 June 1990
Resolved 12 June 1990
Construction/Loadline
Issued 12 June 1990
Resolved
INSTALL CAPS FOR FWD AND AFTER VOID GOOSENECK VENTS.
Condition: Unknown
Due 12 June 1990
Resolved 12 June 1990
Deck/Cargo
Issued 12 June 1990
Resolved
REMOVE TEMPORARY REPAIRS (02) AND MAKE PERMANENT REPAIRS TO FUEL RETURN LINE FROM HYDRAULIC PUMP ENGINE.
Condition: Unknown
Due 12 June 1990
Resolved 12 June 1990
Electrical
Issued 31 March 1990
Resolved
INSTALL VOLTMETER BETWEEN SELECTOR SWITCH AND TUG CONNECTION
Condition: Unknown
Due 31 March 1990
Resolved 31 March 1990
Electrical
Issued 31 March 1990
Resolved
MAKE CABLE INSTALLATION TO HOLD CABLE OUT OF THE WAY OF HAZARD & PERSONNEL
Condition: Unknown
Due 31 March 1990
Resolved 31 March 1990
Electrical
Issued 31 March 1990
Resolved
WEATHERTIGHT BOX FOR UMBILICAL CORD CONNECTION ON TUG HAS HOLE IN SIDE. CONNECTION HAS TO COME OUT THE BOTTOM OF CONNECTION BOX.
Condition: Unknown
Due 31 March 1990
Resolved 31 March 1990
Electrical
Issued 31 March 1990
Resolved
MAKE PILOT LIGHTS HAVE RED GLOBES AS PER PLAN PROPOSED TO MSC.
Condition: Unknown
Due 31 March 1990
Resolved 31 March 1990
Engineering
Issued 4 January 1990
Resolved
SHOW PROPER OPERATION OF BOW THRUSTER UNIT PRIOR TO NEXT USE (46 CFR 58.05).
Condition: Unknown
Due 4 January 1990
Resolved 4 January 1990
Construction/Loadline
Issued 4 January 1990
Resolved
EFFECT PERMANENT REPAIRS TO COLLISION DAMAGE AT BULWARK ON PORT BOW (46 CFR 32.01-10).
Condition: Unknown
Due 4 January 1990
Resolved 4 January 1990
Construction/Loadline
Issued 17 June 1988
Resolved
REMARK VESSEL'S HULL WITH THE PROPER NAME AND HOMEPORT AS PER THE CERT. OF DOCUMENTATION.
Condition: Unknown
Due 17 June 1988
Resolved 17 June 1988
Deck/Cargo
Issued 17 June 1988
Resolved
SHOW PROPER OPERATION OF THE BOWTHRUSTER ENGINE OVERSPEED AND EMERGENCY SHUTDOWN.
Condition: Unknown
Due 17 June 1988
Resolved 17 June 1988
Construction/Loadline
Issued 17 June 1988
Resolved
PROVE PROPER OPERATYION OF THE AIR TANK RELEIF VALVE PRIOR TO NEXT USE.
Condition: Unknown
Due 17 June 1988
Resolved 17 June 1988
Deck/Cargo
Issued 7 November 1985
Resolved
PRIOR TO FLOODING CARGO AND NO LATER THAN 07DEC85 HYDRO TEST ALL ON DECK CARGO TRANSFER AND DISCHARGE LINES TO 225 PSI AND MARK ALL LINES AS REQUIRED BY 33CFR 156.170. NOTIFY OCMI MOBILE, AL IN WRITING WHEN TESTING HAS BEEN COMPLETED.
Condition: Unknown
Due 7 November 1985
Resolved 7 November 1985