NRC ENERGY is a 1980 oil recovery. The Coast Guard has recorded 10 inspections since 2016, most recently in June 2023, along with 12 deficiencies and 1 casualty investigation in 2011.
Records from 2011 to 2023. Most recent: inspection, 1 June 2023.
This record may be incomplete: the most recent inspection recorded for this vessel was 3 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Miscellaneous Vessel class in Maury's sources begin in 2016.
Every line above is a count of records the US Coast Guard wrote, or a date it recorded.
A blank resolution means none was recorded in this data; it does not establish that a
deficiency is outstanding. Years with a record are calendar years in which a record
exists, not years in service. What Maury does
not do.
Tonnage as PSIX records it99 - Regulatory (Subpart C or D), Gross Ton 200 - Convention (Subpart B), Gross Ton 67 - Regulatory (Subpart C or D), Net Ton 60 - Convention (Subpart B), Net Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Vessel history report
Every record for this hull, in one document — $299
Every recorded inspection, 2016 to
2026 for this class, in one chronology · every deficiency, with system, dates
and resolution · operational controls imposed and removed · every name this
hull has been recorded under · the vessels it was inspected alongside, and when
· how its record compares with hulls of similar age and size, as a fact about the
population and never a judgement about this vessel.
This report is in development and is not for sale yet. There is
no date, and nothing is charged. Leave an email and we will tell you when it exists, once.
Used only to tell you when the report exists.
Not shared, not sold, and not added to a mailing list.
Inspection history · 10
1 June 2023Administrative Inspection
Administrative · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7706930
12 July 2022Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7504015
18 May 2021Administrative Inspection · Deficiency Check · Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7199890
16 April 2020Administrative Inspection · Deficiency Check · Drydock Exam · Cargo Tank Internal · COI Inspection · Internal Structural Exam
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 12 July 2022Resolved
The minimum capacity of the fire pump must be 60psi. Fire pump pressure locally at the pump was only 38psi. Replace gauge or ensure pump meets requirements.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 12 July 2022
Resolution: Crew installed new gauge and tested pump sat to 68 psi.
05 - Radio Communications › N/A - No Subsystem › Other (radio communication)
Issued 12 July 2022Resolved
47 CFR 80. 1005; 47 CFR 80.59. Vessel must carry endorsement while subject to Bridge to Bridge Act. A technician must provide valid FCC Saftey Radiotelephony Certificate. Bridge to Bridge Cert and Radiotelephony Cert were both expired.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 15 July 2022
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 12 July 2022Resolved
Each generator must be designed for an ambient temp of 50 deg celsius or derated to 80% output. The installed gens were rated for 40 deg celsius and not derated. Conduct load analysis to ensure equipment meets generator rating.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 13 July 2022
Resolution: Conducted plan review for Gensets and overcurrent protection, all sat.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Gauges, thermometers, etc
Issued 12 July 2022Resolved
Pressure vessel gauge shall be no less than 1.2 times nor more than 2 times the pressure which the relieving device is set to function. Gauge is only capable of 200 PSI reading and relieving device is set to 200 PSI.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 18 July 2022
Resolution: Replaced with proper gauge.
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 18 May 2021Resolved
Updated charts required for areas of operation. Charts onboard not updated.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 19 May 2021
Resolved 18 May 2021
Resolution: Updated Charts onboard.
04 - Emergency Systems › N/A - No Subsystem › Functionality of Safety Systems
Issued 18 May 2021Resolved
Electrical hazards shall be minimized. Ground present on indicator located on the switch board.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 19 May 2021
Resolved 21 May 2021
Resolution: Rewired stern light, Repalced auto pilot and PA. Ground no longer present.
07 - Fire Safety › N/A - No Subsystem › Ventilation
Issued 16 April 2020Resolved
This vessel is equipped with ventilation closures for the machinery space. The closures were found inoperable. Vessel shall correct prior to departure from Southwest Shipyard- Brady Island.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 18 May 2020
Resolution: Received pictures from Port Engineer.
09 - Working and Living Conditions › 091 - Living Conditions › Electrical devices
Issued 16 April 2020Resolved
All recepticals exposed to the weather shall be watertight. Receptical on the back side of the pilot house was missing the cover for the plug.
Action required: 10 - Deficiency Rectified
Resolved 15 May 2020
Resolution: Provided a cover.
Watertight doors must operate as intended. VSL watertight door located on main deck does not close correctly. VSL must adjust door for proper operation.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 29 January 2019
Resolution: Vsl rep provided photo of door sealing surfaces and dogs properly closed.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 15 January 2019Resolved
Exhaust surfaces which reach in excess of 150 degrees must be covered. Exhaust lagging at the bottom of the engineering spaces ladder was broken exposing hot exhaust piping. This was an issue identified during previous inspections and has not been corrected.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 29 January 2019
Resolution: Vsl rep provided picture of repaired lagging.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 15 January 2019Resolved
Waterlight batteries are required to be replaced iaw manufacture recommendation. VSL waterlight battery is expired. VSL must provide appropriate serviceable battery.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 29 January 2019
Resolution: Vsl provided picture of new batteries for water lights.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 15 January 2019Resolved
Pressure relief valves are required to be inspected and certified every five years. Pressure relief valve's inspection on air receiver last tested in April of 2013.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 31 January 2019
Resolution: Received photographic evidence showing a new pressure relief valve installed on the air receiver.
30 December 2011Routine · role: Involved in a Marine Casualty · serious marine incident, as classified · activity 4217669
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.