MAURY USCG vessel records
← All vessels

ATC 25

Built
1981
Last inspected
11 March 2019
Documentation
No record in the NVDC file of 10 August 2026
Controls
None recorded without a removal date

This record may be incomplete: the most recent inspection recorded for this vessel was 7 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Barge class in Maury's sources begin in 1972.

Inspection record

Last inspected 11 March 2019
…with no type recorded57
Operational controls None recorded without a removal date
Years with a record 36 calendar years (1983–2019)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

8645026
WDE6939
Flag
UNITED STATES
Maury page id
psix-53174

Documentation record

Tonnage as PSIX records it24152 - Dead Weight, Ton
12283 - Convention (Subpart B), Gross Ton
11245 - Regulatory (Subpart C or D), Gross Ton
7577 - Convention (Subpart B), Net Ton
11245 - Regulatory (Subpart C or D), Net Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Professional
The full record for this vessel

Behind this panel: 137 inspections, each with its date, unit and type; 120 deficiencies with the resolution recorded against each; operational controls, none recorded without a removal date; 5 other vessels inspected with it; no other recorded names; no NVDC documentation record for this Official Number. Every line is a record the Coast Guard wrote; the counts above are the same counts as in the summary, and they are free.

Professional is $39 a month or $299 a year, or $19.99 a month locked for life at the founding rate, for the first 200 subscribers. It unlocks every detail section on every vessel page, fleet watch tied to your account, and ownership records on request. Already a subscriber? Sign in.

Maury does not score, rate or grade vessels, at any price.

Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 1972 to 2026, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspected as a tow unit · 5

Inspection history · 137

11 March 2019 Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6640113
23 May 2018 Annual Inspection · Administrative Inspection · MTSA Verification
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6421632
14 September 2017 Administrative Inspection · Examination of Repairs
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 6266705
7 September 2017 Administrative Inspection · Damage Survey
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6275579
1 September 2017 Administrative Inspection · Permit to Proceed
Administrative · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6256808
10 January 2017 Administrative Inspection
Administrative · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6104465
15 November 2016 Administrative Inspection · Examination of Repairs · Deficiency Check · Annual Inspection · Internal Structural Exam
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6041741
12 July 2016 Type not recorded
No type recorded · Sector Mobile · USCG Heartland District (CGD-H) · Activity 5938202
4 March 2016 Annual Inspection · MTSA Verification · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 5827182
1 May 2015 Deficiency Check
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 5123571
4 March 2015 MARPOL Annex I Examination · Deficiency Check · Annual Inspection · Administrative Inspection · MTSA Verification · MARPOL Annex VI Survey
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 5078029
18 April 2014 Type not recorded
No type recorded · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 4838684
21 January 2014 COI Inspection · Drydock Exam · Internal Structural Exam
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 4786690
16 December 2013 Type not recorded
No type recorded · Sector Mobile · USCG Heartland District (CGD-H) · Activity 4772337
29 December 2012 Type not recorded
No type recorded · Sector Mobile · USCG Heartland District (CGD-H) · Activity 4511827
13 November 2012 Type not recorded
No type recorded · Sector Mobile · USCG Heartland District (CGD-H) · Activity 4499763
17 January 2012 Deficiency Check · Administrative Inspection
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 4226255
14 January 2012 Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 4243780
5 December 2011 Periodic Inspection · MTSA/ISPS Verification · Internal Structural Exam · Administrative Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 4203024
28 June 2010 Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3780505
15 March 2010 MARPOL Annex VI Survey
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 3695776
4 February 2010 MTSA Verification · Annual Inspection
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 3676126
7 September 2009 Administrative Inspection
Administrative · Commandant (CG-CVC) · Activity 3588298
10 June 2008 Cargo Tank Internal · Ballast Water Examination · MTSA/ISPS Verification · DAPI Audit · MARPOL Annex V Examination · Administrative Inspection · Drydock Exam · MARPOL Annex II Examination · Construction Oversight · MARPOL Annex VI Survey · MARPOL Annex I Examination · COI Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 2696378
2 October 2006 Administrative Inspection
Administrative · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 2791636
22 September 2006 Administrative Inspection
Administrative · Marine Safety Center (MSC) · Activity 2784653
1 May 2006 Security Plan Amendment Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2637873
23 November 2005 Deficiency Check
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 2539945
3 November 2005 Annual Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 2512026
4 October 2005 Cargo Tank Internal · Hull Examination · Internal Structural Exam
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 2507267
26 September 2005 Security Plan Amendment Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2501646
26 August 2005 Administrative Inspection
Administrative · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2490252
5 May 2005 Security Plan Amendment Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2350205
4 November 2004 Deficiency Check
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 2234908
29 October 2004 Annual Inspection
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 2231038
23 September 2004 Security Plan Amendment Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2203396
24 May 2004 MTSA/ISPS Verification
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 2076944
19 April 2004 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 2047763
5 April 2004 MARPOL Annex II Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 2037813
29 December 2003 Security Plan Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 1979836
4 September 2003 Annual Inspection · MARPOL Annex II Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1896966
30 July 2003 MARPOL Annex II Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1861401
2 June 2003 Internal Structural Exam · Hull Examination
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1807735
8 October 2002 Administrative Inspection
Administrative · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1686531
10 September 2002 MARPOL Annex I Examination · Deficiency Check
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1680539
9 September 2002 Annual Inspection
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1670633
20 June 2002 Administrative Inspection
Administrative · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1633822
2 October 2001 Deficiency Check
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1075506
19 September 2001 COI Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1465692
9 February 2001 Deficiency Check
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1058802
4 October 2000 Hull Examination
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1395546
3 October 2000 Administrative
Administrative · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 824817
28 August 2000 COI Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1397486
3 August 2000 Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1467693
25 March 2000 Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 473343
12 December 1999 Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 435690
3 December 1999 Re-Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1450376
11 September 1999 Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 475989
12 April 1999 Administrative
Administrative · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1123047
11 March 1999 Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 515660
2 February 1999 Administrative
Administrative · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1127772
19 October 1998 Deficiency Check
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 801349
1 October 1998 COI Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1452439
16 July 1998 Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 540127
29 May 1998 Hull Examination
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1398920
29 January 1998 Administrative
Administrative · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 785918
5 December 1997 Drydock Extension
Administrative · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1121574
4 December 1997 Re-Inspection
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1372058
21 October 1997 Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 470697
6 July 1997 Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 516193
3 April 1997 Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 473067
26 March 1997 Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 667081
19 November 1996 Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 438875
23 October 1996 Deficiency Check
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 850754
8 October 1996 COI Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1380666
8 September 1996 Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 467047
4 May 1996 Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 490954
6 February 1996 Deficiency Check
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 873346
26 November 1995 Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 532185
21 November 1995 Re-Inspection
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1353820
28 September 1995 Hull Examination · Examination of Repairs
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1367531
23 June 1995 Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 471824
2 March 1995 Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 500657
14 October 1994 COI Inspection
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1429960
8 August 1994 Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 522653
23 January 1994 Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 489767
8 December 1993 Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 439102
17 October 1993 Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 150417
31 August 1993 Re-Inspection
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1146792
7 July 1993 Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 182127
26 March 1993 Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 516424
8 February 1993 Hull Examination
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1146778
20 October 1992 COI Inspection
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 955332
1 October 1992 Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 490612
9 July 1992 Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 351785
20 March 1992 Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 954997
21 February 1992 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 505423
12 December 1991 Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 466804
13 November 1991 Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 347040
16 October 1991 Re-Inspection
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 936624
26 June 1991 Administrative
Administrative · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 913360
22 March 1991 Deficiency Check
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 930374
14 December 1990 Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 930259
10 December 1990 MARPOL Annex II Examination
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1240300
19 November 1990 COI Inspection · Hull Examination
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1227897
8 November 1990 Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 928300
1 August 1989 Type not recorded
No type recorded · Marine Safety Unit Valdez · USCG Arctic District (CGD-A) · Activity 886612
15 July 1989 COI Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1042722
31 May 1989 COI Inspection
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1345332
17 May 1989 Administrative
Administrative · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1276746
2 May 1989 Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 481757
19 November 1988 Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 518712
19 October 1988 Re-Inspection
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 889643
31 May 1988 Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 512621
21 January 1988 Hull Examination
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1025787
25 November 1987 Damage Survey
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1026490
10 November 1987 Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 491942
16 September 1987 COI Inspection · Drydock Extension
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1322194
29 June 1987 Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 317072
6 May 1987 Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 475477
10 April 1987 MARPOL Annex II Examination
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1331373
9 April 1987 MARPOL Annex II Examination
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1020846
29 January 1987 Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 527189
17 October 1986 Re-Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1010472
28 August 1986 Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 456095
5 July 1986 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 309990
10 December 1985 Type not recorded
No type recorded · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 472074
21 November 1985 Type not recorded
No type recorded · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 997932
16 October 1985 Deficiency Check
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1299190
12 October 1985 COI Inspection · Credit Drydock
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1301040
16 May 1985 Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 470167
15 January 1985 Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 511431
20 December 1984 Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 977193
4 December 1984 Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 472126
30 November 1984 Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 976946
12 September 1984 Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 455450
12 October 1983 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 968576

Deficiency record · 120

Deck/Cargo › Vapor Control Systems › Piping/Hoses
Issued 14 December 2016 Resolved
Install stud on portside phenol VCS manifold flange IAW 46CFR39.20-1e.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 15 December 2016
Resolution: New stud was welded on.
Engineering › Fuel Oil Storage/Transfer System › Tank
Issued 14 December 2016 Resolved
Install sight glass guard on bowthruster F.O. day tank IAW 58.50-10a6.
Due 4 January 2017
Resolved 15 December 2016
Resolution: Guard fabricated and installed.
Construction/Loadline › Penetrations › Gasket
Issued 14 December 2016 Resolved
Make pumprooms vapor tight in way of driveshaft penetration IAW 46CFR32.60-20.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 15 December 2016
Resolution: Installed gaskets around pump driveshfts for all pump houses.
Fire Fighting › Portable CO2 Fire Extinguisher › Service
Issued 4 March 2015 Resolved
Service portable firefighting equipment prior to operation as per 46 CFR 31.10-18
Action required: 17 - Rectify deficiencies prior to departure
Due 4 March 2015
Resolved 5 March 2015
Resolution: Recieved servicing report from Hiller showing all portable and fixed fire fighting equipment had been serviced.
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Piping
Issued 4 March 2015 Resolved
Perform annual hydrostatic test of cargo lines prior to cargo operations IAW 46 CFR 35.35.70
Action required: 701 - Prior to carriage of passengers/cargo
Due 4 March 2015
Resolved 6 March 2015
Resolution: Received servicing report showing annual testing of cargo lines occurred 03/06/2015
Pollution Prevention/Response › Prevention Equipment › Overfill Devices
Issued 4 March 2015 Resolved
Prove operation of high level and overfill alarms of 5P and 5S cargo tanks prior to loading IAW 46 CFR 39.20-9
Action required: 705 - Other - as specified
Due 4 March 2015
Resolved 1 May 2015
Resolution: Received DOI showing testing of high level and overfill alarams of the 5P and 5S tanks.
Electrical › Electrical Distribution System (service) › Panelboard
Issued 4 March 2015 Resolved
Provide means to secure doors on panelboards in bow thruster room IAW 46 CFR 111.40-1
Action required: 705 - Other - as specified
Due 4 April 2015
Resolved 5 March 2015
Electrical › Electrical Distribution System (service) › Panelboard
Issued 4 March 2015 Resolved
Label panelboard switching unit and motor controllers IAW 46 CFR 111.40-11
Action required: 705 - Other - as specified
Due 4 April 2015
Resolved 5 March 2015
Resolution: All panelboard and motor controllers were labeled
Electrical › Electrical Distribution System (service) › Panelboard
Issued 4 March 2015 Resolved
Provide blanks for open areas on panelboard IAW 46 CFR 111.40-1
Action required: 705 - Other - as specified
Due 4 April 2015
Resolved 5 March 2015
Electrical › Electric Supply System (service) › Battery Installation
Issued 4 March 2015 Resolved
Properly stow battery in lower bow thruster room as per 46 CFR 111.15-1
Action required: 705 - Other - as specified
Due 4 April 2015
Resolved 5 March 2015
Electrical › Electric Supply System (service) › Battery Installation
Issued 4 March 2015 Resolved
Secure battery box and connectors in lower bow thruster room as per 46 CFR 111.15-1
Action required: 705 - Other - as specified
Due 4 April 2015
Resolved 5 March 2015
Resolution: Battery box and associated connectors were removed.
Deck/Cargo › Mooring/Anchoring › Winch
Issued 4 March 2015 Resolved
Secure leak, remove soaked pads, and prove operation of port anchor winch in upper bow thruster room as per 46 CFR 56.20-9
Action required: 705 - Other - as specified
Due 4 April 2015
Resolved 5 March 2015
Electrical › Electric Supply System (service) › Battery Installation
Issued 4 March 2015 Resolved
Properly wire battery charger for steering light in bow thruster room as per 46 CFR 111.60-19b
Action required: 705 - Other - as specified
Due 4 April 2015
Resolved 5 March 2015
Resolution: Battery charger and associated wiring removed.
Electrical › Electric Supply System (service) › Cable
Issued 4 March 2015 Resolved
Properly wire or remove sump pump installation in bow thruster room as per 46 CFR 111.60-5
Action required: 705 - Other - as specified
Due 4 April 2015
Resolved 5 March 2015
Resolution: A switch was installed.
Deck/Cargo › Holds/Tanks › Coaming
Issued 4 March 2015 Resolved
Provide dogging wrench for all exterior doors and prove operation as per 46 CFR 170-270
Action required: 705 - Other - as specified
Due 4 April 2015
Resolved 5 March 2015
Fire Fighting › Fixed CO2 Fire Extinguishing System › Operating Instructions
Issued 4 March 2015 Resolved
Provide line diagram of fixed CO2 in bow thruster room as per 46 CFR 153.460; 46 CFR 34.15-10
Action required: 705 - Other - as specified
Due 4 April 2015
Resolved 5 March 2015
Fire Fighting › Fixed CO2 Fire Extinguishing System › Operating Instructions
Issued 4 March 2015 Resolved
Provide instructions for operation of CO2 system pull box outside the bow thruster room as per 46 CFR 153.460; 46 CFR 34.15-10
Action required: 705 - Other - as specified
Due 4 April 2015
Resolved 5 March 2015
Lifesaving › Lifebuoys › Markings (ship name/port)
Issued 4 March 2015 Resolved
Stencil vessel name on life rings as per 46 CFR 199.70
Action required: 705 - Other - as specified
Due 4 April 2015
Resolved 5 March 2015
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 4 March 2015 Resolved
Paint screens for outboard lights matte black as per 33 CFR 84.05
Action required: 705 - Other - as specified
Due 4 April 2015
Resolved 5 March 2015
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Cargo Pump
Issued 4 March 2015 Resolved
Make repairs to #1 cargo pump exhaust prior to operation of #1 cargo pump prior to operation of #1 cargo pump as per 46 CFR 58.10-10
Action required: 705 - Other - as specified
Due 4 March 2015
Resolved 23 March 2015
Resolution: Received photos depicting the exhaust piping on the #1 cargo pump was renewed.
Documentation › Logs/Records › Oil Record Book
Issued 4 March 2015 Resolved
Conduct training on properly filling out Oil Record Book IAW 33CFR151.25
Action required: 705 - Other - as specified
Due 4 April 2015
Resolved 5 March 2015
Resolution: Gave training to personnel responsible for filling out the oil record book.
Operations/Management › Pollution › Other MARPOL Annex VI Deficiencies
Issued 4 March 2015 Resolved
Provide fuel samples from bunkering for a period of not less than 12 months as per MARPOL Annex VI/8.1
Action required: 705 - Other - as specified
Due 4 March 2016
Resolved 4 March 2015
Documentation › Certificates/Documents › International Air Pollution Prevention Certificate
Issued 21 January 2014 Resolved
Demonstrate valid VOC management plan for carrying crude oil IAW MARPOL VI / 15.6.
Due 4 May 2014
Resolved 9 June 2014
Resolution: Recv''d MSC letter, serial: C1-1401826, dated May 29, 2014, VOC Management Plan.
Electrical › Electrical Distribution System (service) › Metallic Enclosure/Frame
Issued 4 February 2010 Resolved
Electrical distribution panel on the second deck (forward) leading to the bow thruster room was missing an electrical blank (breaker). Owner/operator to install a "blank" in the electrical panel if the additional breaker is not needed.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 4 February 2010
Resolved 4 February 2010
Resolution: Blank was installed in the electrical distribution panel''s breaker panel.
Accommodation/Occupational Safety › Occupational Safety › Tripping/Falling Hazard
Issued 4 February 2010 Resolved
Two deck plates in the aft, engineering space were showing significant signs of deterioration. The two deck plates were rusted through, potentially causing a hazard for crewmembers transiting the space. Both deck plates need to be renewed or have the rusted areas cropped out and repaired.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 4 February 2010
Resolved 4 February 2010
Resolution: Deck plates were cropped and repaired by the Chief Engineer.
Documentation › Safety/Response Plans/Programs › Vessel Response Plan
Issued 21 July 2009 Resolved
-Per 33 CFR 155.1040(a), the Areas of Operation List must be amended to reflect the addition of the Great Lakes COTP zones. -Per 33 CFR 155.1040(j), the geographic-specific appendix for each COTP zone must include notifications to the appropriate state authorities, including boundary states.
Due 21 August 2009
Resolved 14 December 2009
Resolution: VRP for ATC 25 does not authorize Great Lakes COTP zones. (see narrative - Activity #3588298)
Documentation › Certificates/Documents › Annex VI Statement of Voluntary Compliance Supplement
Issued 10 June 2008 Resolved
PROVIDE RECORD BOOK OF ENGINE PARAMETERS FOR CATERPILLAR ENGINE SERIAL # RND00302.
Action required: 705 - Other - as specified
Due 4 February 2010
Resolved 4 February 2010
Resolution: Vessel has on board a Caterpillar tech. manual for the respective diesel engine, serial number RND00302. This tech. manual is stored in the accommodation space/store room on the aft, port side of the barge.
Documentation › Certificates/Documents › Annex VI Statement of Voluntary Compliance
Issued 10 June 2008 Resolved
PROVIDE PROOF OF COMPLIANCE WITH RECORD SYSTEM FOR SAVING BUNKER NOTES AND SAMPLES.
Due 20 June 2009
Resolved 4 February 2010
Resolution: Compliance with records system for the saving of bunkering notes and samples was shown to the attending C.G. inspector.
Fire Fighting › Fixed Halon Fire Extinguishing System › Operating Controls
Issued 11 October 2005 Resolved
Tighten actuating lever to provide proper seal for Halon bottle cylinder valve in generator room.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 3 December 2005
Resolved 21 November 2005
Resolution: Marine Inspector attended vessel, observed corrections, and cleared deficiency.
Accommodation/Occupational Safety › Ventilation › General
Issued 11 October 2005 Resolved
Install flame screen in sewage tank vent.
Action required: 705 - Other - as specified
Due 17 November 2005
Resolved 21 November 2005
Resolution: Marine Inspector attended vessel, observed corrections, and cleared deficiency.
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 11 October 2005 Resolved
Install clip for waterlight on ring buoy outside of accommodation space.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 3 December 2005
Resolved 21 November 2005
Resolution: Marine Inspector attended vessel, observed corrections, and cleared deficiency.
Accommodation/Occupational Safety › Ventilation › General
Issued 11 October 2005 Resolved
Re-new flame screen on paint locker vent.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 17 November 2005
Resolved 21 November 2005
Resolution: Marine Inspector attended vessel, observed corrections, and cleared deficiency.
Construction/Loadline › Structures › Superstructure
Issued 11 October 2005 Resolved
Install fasteners on soft patch on top of generator house.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 3 December 2005
Resolved 21 November 2005
Resolution: Marine Inspector attended vessel, observed corrections, and cleared deficiency.
Deck/Cargo › Vapor Control Systems › Flame Screens
Issued 11 October 2005 Resolved
Re-new flame screen on day-tank vent for #3 pump.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 17 November 2005
Resolved 21 November 2005
Resolution: Marine Inspector attended vessel, observed corrections, and cleared deficiency.
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Transfer Hose
Issued 11 October 2005 Resolved
Re-new 2.5" fuel barge-to-towing vessel transfer hose.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 3 December 2005
Resolved 21 November 2005
Resolution: Marine Inspector attended vessel, observed corrections, and cleared deficiency.
Electrical › Electrical Distribution System (service) › Wiring
Issued 11 October 2005 Resolved
Secure loose wire in IG room ceiling.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 3 December 2005
Resolved 21 November 2005
Resolution: Marine Inspector attended vessel, observed corrections, and cleared deficiency.
Communications › Radio Communications › VHF Radiotelephone
Issued 11 October 2005 Resolved
Repair wire for VHF radio telephone.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 3 December 2005
Resolved 21 November 2005
Resolution: Marine Inspector attended vessel, observed corrections, and cleared deficiency.
Construction/Loadline › Structures › Machinery Space Opening
Issued 11 October 2005 Resolved
Make aft door to generator room weathertight.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 3 December 2005
Resolved 21 November 2005
Construction/Loadline › Structures › Machinery Space Opening
Issued 11 October 2005 Resolved
Make door on #3 pumphouse weather tight.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 3 December 2005
Resolved 21 November 2005
Resolution: Marine Inspector attended vessel, observed corrections, and cleared deficiency.
Construction/Loadline › Structures › Superstructure
Issued 11 October 2005 Resolved
Seal hole in bulk-head of #3 pumphouse.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 3 December 2005
Resolved 21 November 2005
Resolution: Marine Inspector attended vessel, observed corrections, and cleared deficiency.
Engineering › Fuel Oil Service System › Hose
Issued 11 October 2005 Resolved
Re-new fuel supply hose on #2 pump engine.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 17 November 2005
Resolved 21 November 2005
Resolution: Marine Inspector attended vessel, observed corrections, and cleared deficiency.
Engineering › Fuel Oil Service System › Hose
Issued 11 October 2005 Resolved
Re-new hot start supply line on #2 pump engine.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 3 December 2005
Resolved 21 November 2005
Resolution: Marine Inspector attended vessel, observed corrections, and cleared deficiency.
Accommodation/Occupational Safety › Ventilation › General
Issued 11 October 2005 Resolved
Remove duct tape on paint locker vent and provide proper seal to the same.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 3 December 2005
Resolved 21 November 2005
Resolution: Marine Inspector attended vessel, observed corrections, and cleared deficiency.
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Cargo Manifold
Issued 11 October 2005 Resolved
Remove reducer manifold on port side vapor manifold or install proper flange stud.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 3 December 2005
Resolved 21 November 2005
Resolution: Marine Inspector attended vessel, observed corrections, and cleared deficiency.
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Emergency Shut-down
Issued 11 October 2005 Resolved
Prove proper operation of # 3 transfer pump engine prior to placing into service. Also, prove operation of remote shut-down.
Action required: 705 - Other - as specified
Due 3 December 2005
Resolved 21 November 2005
Resolution: Marine Inspector attended vessel, observed corrections, and cleared deficiency.
Electrical › Electrical Distribution System (service) › Cable
Issued 11 October 2005 Resolved
Repack stuffing box in accommodation space.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 3 December 2005
Resolved 21 November 2005
Resolution: Marine Inspector attended vessel, observed corrections, and cleared deficiency.
Electrical › Electric Generation Source (service) › Generator
Issued 11 October 2005 Resolved
Conduct reverse-power relay test and low lube oil test on all generators in the presence of a CG marine inspector.
Due 17 November 2005
Resolved 21 November 2005
Resolution: Marine Inspector attended vessel, observed corrections, and cleared deficiency.
Deck/Cargo › Inert Gas System › Deck Water Seal
Issued 29 October 2004 Resolved
MAKE PERMANENT REPAIRS TO THE SOFT PATCH ON THE DECK WATER SEAL.
Condition: Damaged By Earlier Event
Action required: 701 - Prior to carriage of passengers/cargo
Due 11 November 2004
Resolved 4 November 2004
Pollution Prevention/Response › Prevention Equipment
Issued 4 September 2003 Resolved
Prove proper operation of 98% full light at #2S cargo tank. LEGACY COMPONENT DESC: Overfill Devices
Action required: 701 - Prior to carriage of passengers/cargo
Due 4 October 2003
Resolved 11 September 2003
Engineering › Diesel Engine (auxiliary)
Issued 4 September 2003 Resolved
Permanently repair oil leak on the at sea genset diesel engine. LEGACY COMPONENT DESC: oil pump
Action required: 705 - Other - as specified
Due 4 October 2003
Resolved 11 September 2003
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 8 October 2002 Resolved
Install protective guards/insulation over cargo pump prime mover turbo exhaust elbow.
Due 9 October 2002
Resolved 8 October 2002
Resolution: Rcvd report attesting to the installation of protective guards and insulated material placed on cargo pump exhaust.
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 8 October 2002 Resolved
Install insulation starboard generator exhaust piping.
Due 9 October 2002
Resolved 8 October 2002
Resolution: Rcvd report attesting to the installation of insulated material on generator exhaust piping.
Engineering › Fuel Oil Service System › Piping
Issued 8 October 2002 Resolved
Make permanent repairs/renew soft patch on fuel oil purge piping.
Due 9 October 2002
Resolved 8 October 2002
Resolution: Rcvd report attesting to the fabrication and installation of new section of piping.
Pollution Prevention/Response › Prevention Equipment
Issued 10 September 2002 Resolved
Provide fitted standard discharge shore connection or portable adapter that meets specifications of 33 CFR 155.430 for discharge of oily wastes to reception facilities. ***Must be completed to the satisfaction of attending CG Marine Inspector prior to 01OCT02 so that new IOPP Cert. can be issued. LEGACY COMPONENT DESC: Standard Discharge Connection
Condition: Unknown
Action required: 705 - Other - as specified
Due 1 October 2002
Resolved 27 September 2002
Resolution: Received facsimile documentation & specifications verifying operator purchase and receipt of proper standard discharge connection to be delivered to the vessel on arrival at Port Everglades Florida on or about 01OCT02.
Deck/Cargo › Ballast
Issued 10 September 2002 Resolved
IAW NVIC 6-94, SBTs were sighted from topside & no oil contamination or cargo tank cross connections were evident. Internal examination requirements were not completed but should be done during next scheduled drydock. LEGACY COMPONENT DESC: Segregated Ballast Tank
Action required: 705 - Other - as specified
Due 10 September 2003
Resolved 23 June 2003
Deck/Cargo › Inert Gas System
Issued 9 September 2002 Resolved
Make permanent repairs/renew soft-patched deck seal & IGS piping IWO deck seal. Requirement must be completed prior to 09OCT02 or barge is limited to Grade E cargo only. OCMI letter of 03OCT02 extended compliance date to 09NOV02 for fabrication/installation of new deck seal. LEGACY COMPONENT DESC: Water Seal
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 9 November 2002
Resolved 1 November 2002
Resolution: Inspector from MSSO Brownsville verified satisfactory installation of new deck seal while attending barge at Oil Dock #5 in the Port of Brownsville.
Deck/Cargo › Holds/Tanks
Issued 9 September 2002 Resolved
Make permanent repairs/renew soft-patched fuel oil purge piping. LEGACY COMPONENT DESC: Ventilation Exhaust Trunking
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 9 October 2002
Resolved 23 June 2003
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 9 September 2002 Resolved
Renew missing handrail IWO living quarters.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 9 October 2002
Resolved 10 September 2002
Resolution: Rail temp repair completed with installation of safety chain.
Accommodation/Occupational Safety › Occupational Safety
Issued 9 September 2002 Resolved
Install protective guards/insulation over exposed cargo pump prime mover turbo exhaust elbows. LEGACY COMPONENT DESC: Guards for Exposed Hazards
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 9 October 2002
Resolved 23 June 2003
Accommodation/Occupational Safety › Occupational Safety
Issued 9 September 2002 Resolved
Install insulation on exposed starboard generator exhaust piping. LEGACY COMPONENT DESC: Guards for Exposed Hazards
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 9 October 2002
Resolved 23 June 2003
Deck/Cargo › Vapor Control Systems
Issued 9 September 2002 Resolved
Intall/renew flange stud on port vapor control system manifold. LEGACY COMPONENT DESC: Piping/Hoses
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 9 October 2002
Resolved 10 September 2002
Resolution: Installed as required.
Electrical › Electric Generation Source (service) › Conductor
Issued 9 September 2002 Resolved
Replace wire nuts on generator selenoids with approved connectors.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 9 October 2002
Resolved 10 September 2002
Resolution: Installed as required.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 9 September 2002 Resolved
Replace expired medications in first aid kit.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 9 October 2002
Resolved 10 September 2002
Resolution: Meds replaced as required.
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 9 September 2002 Resolved
Replace starboard navigation light.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 9 October 2002
Resolved 10 September 2002
Resolution: Light replaced as required.
Electrical
Issued 19 September 2001 Resolved
Provide berth lighting for each berth ensuring that the lights have protective guards.
Condition: Unknown
Due 19 September 2001
Resolved 19 September 2001
Electrical
Issued 19 September 2001 Resolved
Install a blank cover for the blank breaker in panel P122 in the galley.
Condition: Unknown
Due 19 September 2001
Resolved 19 September 2001
Electrical
Issued 19 September 2001 Resolved
Provide a rubber mat in front of the switchboard next to the #2 generator.
Condition: Unknown
Due 19 September 2001
Resolved 19 September 2001
Fire Fighting
Issued 19 September 2001 Resolved
Demonstrate proper operation of the smoke detector in the berthing space. Battery was replaced while onboard.
Condition: Unknown
Due 26 September 2001
Resolved 21 September 2001
Electrical
Issued 19 September 2001 Resolved
Properly stow and remove the equipment from behind the main generator switchboard.
Condition: Unknown
Due 19 September 2001
Resolved 19 September 2001
Fire Fighting
Issued 19 September 2001 Resolved
Demonstrate proper operation of the vent closer cover for the paint locker on the open deck starboard side aft.
Condition: Unknown
Due 19 September 2001
Resolved 19 September 2001
Deck/Cargo
Issued 19 September 2001 Resolved
Legibly, label the cargo hoses with the Maximum Working Pressure (MWAP) and"For Oil Use Only".
Condition: Unknown
Due 19 September 2001
Resolved 19 September 2001
Electrical
Issued 19 September 2001 Resolved
Install a blank cover for the blank breaker in panel L101 in forward Bosn stores.
Condition: Unknown
Due 19 September 2001
Resolved 19 September 2001
Electrical
Issued 19 September 2001 Resolved
Replace the burnt out lights in the, aft starboard store room, and battery locker.
Condition: Unknown
Due 19 September 2001
Resolved 19 September 2001
Deck/Cargo
Issued 19 September 2001 Resolved
Label vapor recovery line in accordance with 46 CFR 39.20. Presently the last meter is paint over.
Condition: Unknown
Due 19 September 2001
Resolved 19 September 2001
Electrical
Issued 19 September 2001 Resolved
Properly install the wiring for the electrical outlet for the TV in the berthing space.
Condition: Unknown
Due 19 September 2001
Resolved 19 September 2001
Lifesaving
Issued 19 September 2001 Resolved
Replace the ring buoys reflective tape with approved tape in accordance with IMO 658 (16).
Condition: Unknown
Due 19 September 2001
Resolved 19 September 2001
Lifesaving
Issued 19 September 2001 Resolved
Replace the attachment line to ring buoys in accordance with 46 CFR 199.70.
Condition: Unknown
Due 19 September 2001
Resolved 19 September 2001
Deck/Cargo
Issued 19 September 2001 Resolved
Permanently and properly repair the spoil piece, coming off the salt-water cooling pump for the inert gas generator. Located between the pump and valve. Presently there is a hose clamp and soft patch.
Condition: Unknown
Due 19 September 2001
Resolved 19 September 2001
Construction/Loadline
Issued 19 September 2001 Resolved
Make permanent and proper repairs to the aft starboard hatch leading down to the aft stores space. Presently the hatch can not be made watertight. Dogging ears/tabs are wasted.
Condition: Unknown
Due 19 September 2001
Resolved 19 September 2001
Fire Fighting
Issued 19 September 2001 Resolved
Properly inert cargo tanks in accordance with company policy. To be set atless than 5% oxygen. Tanks were inerted prior to the completion of the exam.
Condition: Unknown
Due 19 September 2001
Resolved 21 September 2001
Lifesaving
Issued 19 September 2001 Resolved
Provide proof of register for the EPIRB to NOAA. Certificate provide whileonboard.
Condition: Unknown
Due 26 September 2001
Resolved 21 September 2001
Construction/Loadline
Issued 4 October 2000 Resolved
Crop and renew angle support beneath salt water service and slop line on stbd manifold.
Condition: Unknown
Due 4 October 2000
Resolved 4 October 2000
Deck/Cargo
Issued 4 October 2000 Resolved
Renew pipe support brackets where needed.
Condition: Unknown
Due 4 October 2000
Resolved 4 October 2000
Lifesaving
Issued 4 October 2000 Resolved
Crop and renew to good metal portions of service air line where its needed to the satisfaction of attending marine inspector.
Condition: Unknown
Due 4 October 2000
Resolved 4 October 2000
Engineering
Issued 4 October 2000 Resolved
Crop and renew to good metal fuel supply line to pump houses where necessary to the satisfaction of attending marine inspector.
Condition: Unknown
Due 4 October 2000
Resolved 4 October 2000
Accommodation/Occupational Safety
Issued 4 October 2000 Resolved
Make permanent repairs to catwalks and stairways to the satisfaction of attending marine inspector.
Condition: Unknown
Due 4 October 2000
Resolved 4 October 2000
Construction/Loadline
Issued 4 October 2000 Resolved
Crop and renew wasted 2" pipe in fwd main deck above fore peak ballast tank(supply line for eductor).
Condition: Unknown
Due 4 October 2000
Resolved 4 October 2000
Fire Fighting
Issued 4 October 2000 Resolved
Crop and renew to good metal portions of salt water service line where needed, to the satisfaction of attending marine inspector.
Condition: Unknown
Due 4 October 2000
Resolved 4 October 2000
Deck/Cargo
Issued 4 October 2000 Resolved
Crop and renew to good metal #3 and #4 mooring winch foundation, to the satisfaction of attending marine inspector.
Condition: Unknown
Due 4 October 2000
Resolved 4 October 2000
Deck/Cargo
Issued 4 October 2000 Resolved
Crop and renew angle support beneath cargo piping on port side manifold.
Condition: Unknown
Due 4 October 2000
Resolved 4 October 2000
Accommodation/Occupational Safety
Issued 4 October 2000 Resolved
Master to advise crew not to use catwalks and stairways with missing handrail and wasted steps and landings until proper repair is done.
Condition: Unknown
Due 4 October 2000
Resolved 4 October 2000
Construction/Loadline
Issued 3 August 2000 Resolved
Effect permanent repairs to starboard aft ballast tank on side shell after of tank. Repair at next dry-dock and to the satisfaction of the local OCMI.
Condition: Unknown
Due 3 August 2000
Resolved 3 August 2000
Construction/Loadline
Issued 3 August 2000 Resolved
Effect permanent repairs to starboard mid-ballast tank on side shell approximately twelve feet from top in middle section of tank. Repair at next drydock and to the satisfaction of the local OCMI.
Condition: Unknown
Due 3 August 2000
Resolved 3 August 2000
Lifesaving
Issued 3 December 1999 Resolved
REMOVE EXCESSIVE PAINT OR PLACE ALL FLAMMABLE CONTAINERS IN PAINT LOCKER UPON ARRIVAL TO HOMEPORT.
Condition: Unknown
Due 8 December 1999
Resolved 13 December 1999
Construction/Loadline
Issued 3 December 1999 Resolved
REPAIR DOGS ON EXTERIOR WEATHERTIGHT DOORS AS NEEDED.
Condition: Unknown
Due 13 December 1999
Resolved 13 December 1999
Fire Fighting
Issued 3 December 1999 Resolved
MAKE TEMPORARY REPAIRS TO WASTED FIRE MAIN PIPING TO THE SATISFACTION OF ABS CLASS SOCIETY SURVEYOR PRIOR TO SAILING. SUBMIT PROPOSAL FOR TEMPORARYAND PERMANENT REPAIRS TO [name withheld], FLORIDA PRIOR TO EXECUTION OF REPAIRS.
Condition: Unknown
Due 8 December 1999
Resolved 8 December 1999
Engineering
Issued 1 October 1998 Resolved
MAKE PERMANENT REPAIRS TO HOLED EXHAUST MANIFOLD ON AT SEA GENERATOR. (CURRENTLY REPAIRED WITH RED-HAND)
Condition: Unknown
Due 15 October 1998
Resolved 26 October 1998
Electrical
Issued 1 October 1998 Resolved
PROVE PROPER OPERATION OF REVERSE CURRENT RELAY OF GENERATORS OR PROVIDE WRITTEN DOCUMENTATION TO THIS OFFICE AS TO WHY THE SYSTEM WON'T WORK.
Condition: Unknown
Due 15 October 1998
Resolved 26 October 1998
Deck/Cargo
Issued 1 October 1998 Resolved
INSTALL REQUIRED STUD AT THE 12 O'CLOCK POSITION ON THE PORT VAPOR COLLECTION SYSTEM MANIFOLD.
Condition: Unknown
Due 15 October 1998
Resolved 26 October 1998
Fire Fighting
Issued 1 October 1998 Resolved
HAVE B-V FIRE EXTINGUISHER SERVICED.
Condition: Unknown
Due 8 October 1998
Resolved 26 October 1998
Engineering
Issued 1 October 1998 Resolved
PROVE PROPER OPERATION OF RELIEF VALVES ON BOTH AIR RECEIVERS AND ENSURE GAUGES ARE PROPERLY CALIBRATED.
Condition: Unknown
Due 15 October 1998
Resolved 26 October 1998
Engineering
Issued 1 October 1998 Resolved
REPLACE WASTED SPARK ARRESTOR FOR AT SEA GENERATOR.
Condition: Unknown
Due 15 October 1998
Resolved 26 October 1998
Engineering
Issued 1 October 1998 Resolved
INSTALL PLUG & FLAME IMPINGEMENT BOWL ON RACOR FUEL FILTER FOR THE AT SEA GENERATOR.
Condition: Unknown
Due 15 October 1998
Resolved 26 October 1998
Engineering
Issued 4 December 1997 Resolved
CROP AND RENEW ALL FUEL AND BUNKER LINES AS NEEDED ON MAIN DECK.
Condition: Unknown
Due 4 December 1997
Resolved 4 December 1997
Deck/Cargo
Issued 4 December 1997 Resolved
PROVIDE U.S.C.G PROVE OF STANDARD DISCHARGE CONNECTION.
Condition: Unknown
Due 11 December 1997
Resolved 15 December 1997
Fire Fighting
Issued 8 October 1996 Resolved
CONDUCT FIXED FIRE FIGHTING SYSTEM TESTS IN PRESENCE OF USCG MARINE INSPECTOR.
Condition: Unknown
Due 8 October 1996
Resolved 8 October 1996
Deck/Cargo
Issued 8 October 1996 Resolved
INSTALL PERMANENT STUDS IN VCS PIPING FLANGES AT "12:00" POSITION.
Condition: Unknown
Due 8 October 1996
Resolved 8 October 1996
Deck/Cargo
Issued 8 October 1996 Resolved
REPLACE LOWER RELIEF VALVE ON SHIP SERVICE AIR RECEIVER.
Condition: Unknown
Due 8 October 1996
Resolved 8 October 1996
Electrical
Issued 21 November 1995 Resolved
PERMANENTLY MOUNT LUBE OIL TRANSFER PIPING LOCATED ABOVE OUTBOARD SSDG
Condition: Unknown
Due 21 November 1995
Resolved 21 November 1995
Fire Fighting
Issued 21 November 1995 Resolved
MAKE REPAIRS TO GENERATOR ROOM VENTILATION COVERS
Condition: Unknown
Due 21 November 1995
Resolved 21 November 1995
Engineering
Issued 19 November 1990 Resolved
REPAIR OR REPLACE RELIEF VALVE ON THE NUMBER 1 SHIPS SERVICE AIR RECEIVER AND PROVE ITS OPERATION TO A USCG INSPECTOR.
Condition: Unknown
Due 19 November 1990
Resolved 19 November 1990
Documentation
Issued 19 November 1990 Resolved
PROVIDE USCG MARINE SAFETY CENTER APPROVED VAPOR CONTROL/RECOVERY DRAWINGS WITH APPLICABLE COMMENT LETTER. THE INSTALLATION AND OPERATIONAL TEST OF THE VAPOR CONTROL/RECOVERY SYSTEM SHALL BE REVIEWED TO THE SATISFACTION OF OF A USCG INSPECTOR. (NEW VAPOR CONTROL PIPING WAS AIR TESTED AT 4.5 PSI).
Condition: Unknown
Due 19 November 1990
Resolved 19 November 1990
Documentation
Issued 19 November 1990 Resolved
(CONT) THE VAPOR CONTROL/RECOVERY SYSTEM SHALL NOT BE USED UNTIL THIS ITEM IS COMPLETED.
Condition: Unknown
Due 19 November 1990
Resolved 19 November 1990
Documentation
Issued 19 November 1990 Resolved
PROVIDE (ANNUAL) ENDORSED LOADLINE CERTIFICATE BEFORE OPERATING BARGE.
Condition: Unknown
Due 19 November 1990
Resolved 19 November 1990
Deck/Cargo
Issued 15 July 1989 Resolved
PROVE PROPER OPERATION OF IGS ALARMS/SHUTDOWNS IAW 46 CFR 32.53-70 AND USCGAPPROVED TEST PROCEDURE DATED 20NOV85: HIGH INERT GAS TEMPERATURE, LOW INERT GAS PRESSURE, AND LOSS OF WATER SUPPLY TO THE DECK WATER SEAL.
Condition: Unknown
Due 15 July 1989
Resolved 15 July 1989
Electrical
Issued 15 July 1989 Resolved
DEMONSTRATE OPERATION OF THE NUMBER ONE GENERATOR: UNDER LOAD, AND OVERSPEED AND LUBE OIL TRIPS.
Condition: Unknown
Due 15 July 1989
Resolved 15 July 1989
Construction/Loadline
Issued 25 November 1987 Resolved
MAKE PERMANENT REPAIRS SIDE SHELL AND DECK IN WAY OF DAMAGE LOCATED STBD SIDE, AFT MACHINERY SPACE.
Condition: Unknown
Due 25 November 1987
Resolved 25 November 1987
Deck/Cargo
Issued 12 October 1985 Resolved
REPAIR DECK SEAL LOW PRESSURE/ LEVEL ALARM ELECTRICAL WIRING AND DEMOSTRATEOPERATION TO A COAST GUARD MARINE INSPECTOR NO LATER THAN 12NOV85.
Condition: Unknown
Due 12 October 1985
Resolved 12 October 1985
Documentation
Issued 30 November 1984 Resolved
OBTAIN VALID RENEWAL STICKER FOR CERTIFICATE OF DOCUMENTATION W/I 30 DAYS. THE ABOVE REQUIREMENTS TO BE CORRECTED TO THE SATISFACTION OF THE COGNIZANTOCMI AND ATTENDING USCG INSPECTOR.
Condition: Unknown
Due 30 November 1984
Resolved 30 November 1984
Lifesaving
Issued 30 November 1984 Resolved
INSTALL AN APPROVED PERSONAL FLOTATION DEVICE LIGHT ON EACH EXPOSURE SUIT (4 TOTAL).
Condition: Unknown
Due 30 November 1984
Resolved 30 November 1984