MAURY USCG vessel records
← All vessels

NLB 4-81

Built
1981
Last inspected
15 January 2015
Documentation
Expired · NVDC file of 10 August 2026
Controls
None recorded without a removal date

This record may be incomplete: the most recent inspection recorded for this vessel was 11 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Barge class in Maury's sources begin in 1972.

Inspection record

Last inspected 15 January 2015
…with no type recorded9
Operational controls None recorded without a removal date
Years with a record 27 calendar years (1981–2015)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

Flag
UNITED STATES
Maury page id
psix-53455

Documentation record

Registered dimensions (L × B × D)150.0 ft × 35.0 ft × 8.6 ft
Registered tonnagegross 422 / net 422
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderBERGERON INDUSTRIES INC · PEARLINGTON, MS, UNITED STATES · built 1981
Hull materialSteel
PropulsionUNSPECIFIED
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing portINTRACOASTAL CITY, LA
Endorsements, as the file codes themcw_un
DocumentationExpired · issued 30 June 2004
Service, as the file records itTank Barge
Hull formbarge (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it422 - Regulatory (Subpart C or D), Gross Ton
422 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Professional
The full record for this vessel

Behind this panel: 46 inspections, each with its date, unit and type; 22 deficiencies with the resolution recorded against each, 1 without one; operational controls, none recorded without a removal date; 2 other vessels inspected with it; no other recorded names; the documentation record: dimensions, tonnage, builder, hailing port and endorsements. Every line is a record the Coast Guard wrote; the counts above are the same counts as in the summary, and they are free.

Professional is $39 a month or $299 a year, or $19.99 a month locked for life at the founding rate, for the first 200 subscribers. It unlocks every detail section on every vessel page, fleet watch tied to your account, and ownership records on request. Already a subscriber? Sign in.

Maury does not score, rate or grade vessels, at any price.

Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 1972 to 2026, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspected as a tow unit · 2

The Coast Guard recorded this vessel and the following in the same inspection activity — normally a tug and the barges in its tow. A recreational or unclassed hull in the same activity is held and not published, so it does not appear here: these lists are a floor, not a complete manifest.

MISS EDMAY Towing Vessel · MISLE 649444 · 6 January 2015 · activity 5049452CHERYL ANNE Towing Vessel · MISLE 159003 · 6 January 2014 · activity 4778480

Inspection history · 46

15 January 2015 Damage Survey · Administrative Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 5053669
6 January 2015 Type not recorded
No type recorded · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 5049452
6 January 2015 Damage Survey
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 5050344
3 June 2014 Type not recorded
No type recorded · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 4892450
6 January 2014 Type not recorded
No type recorded · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 4778480
16 August 2012 Internal Structural Exam · COI Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 4412462
20 September 2011 Annual Inspection · Administrative Inspection · Deficiency Check
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 4152074
25 August 2010 Periodic Inspection · Examination of Repairs · Administrative Inspection · Damage Survey
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3833266
16 October 2008 Deficiency Check · Annual Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3345917
27 June 2006 MTSA Verification · Hull Examination · Administrative Inspection · Internal Structural Exam · Deficiency Check · COI Inspection · Examination of Repairs · Cargo Tank Internal
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2693480
29 March 2006 Type not recorded
No type recorded · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 2612176
10 March 2006 Administrative Inspection
Administrative · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 2599875
2 August 2004 Administrative Inspection
Administrative · MIDET WEST DETAIL · USCG Heartland District (CGD-H) · Activity 2153791
11 May 2004 Administrative Inspection
Administrative · MIDET EAST BANK DETAIL · USCG Heartland District (CGD-H) · Activity 2065185
20 April 2004 Administrative Inspection
Administrative · MIDET EAST BANK DETAIL · USCG Heartland District (CGD-H) · Activity 2048590
1 February 2004 Administrative Inspection
Administrative · MIDET EAST BANK DETAIL · USCG Heartland District (CGD-H) · Activity 2009150
29 December 2003 Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1971006
7 November 2002 Annual Inspection · Deficiency Check
Physical examination · MIDET HARVEY CANAL DETAIL · USCG Heartland District (CGD-H) · Activity 1698816
20 February 2002 Re-Inspection · Internal Structural Exam
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1487295
11 December 2001 Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 773018
25 October 2001 Re-Inspection · Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1429644
10 August 2001 Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 55821
30 October 2000 COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1420422
28 October 1999 Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1399207
30 October 1998 COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1470481
13 November 1997 Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1372043
14 November 1996 COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1357793
22 January 1996 Hull Examination · Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1400258
7 March 1995 Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 858558
17 February 1995 Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 845211
19 January 1995 Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1177540
17 November 1994 COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 872950
17 November 1994 COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1401952
5 October 1994 Type not recorded
No type recorded · Marine Safety Unit Victoria · USCG Heartland District (CGD-H) · Activity 154564
20 January 1994 Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1387419
1 December 1992 Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 829578
17 November 1992 COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1467826
13 November 1991 Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1246589
13 November 1990 COI Inspection · Hull Examination
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1223354
2 November 1989 Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1215502
14 November 1988 COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1206143
21 October 1987 Re-Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1332637
15 January 1987 Administrative
Administrative · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1317908
13 November 1986 COI Inspection
Physical examination · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1329743
8 November 1984 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 977769
3 November 1981 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1273030

Deficiency record · 22

Construction/Loadline › Hull › Bottom Plating
Issued 6 January 2015 No resolution recorded
Vessel suffered a 3 inch diameter puncture on the stbd stern side aft. The breach is 4ft inboard and 10ft forward of the stern rake near the void surrounding the number 5 cargo tank. Prior to carrying cargo the vessel is to affect permanent repairs.
Action required: 705 - Other - as specified
Pollution Prevention/Response › Prevention Equipment › Drains/Scuppers (means of closure)
Issued 20 September 2011 Resolved
Discharge containment plug was missing.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 12 October 2011
Resolution: Plug replaced.
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Cargo Pump
Issued 20 September 2011 Resolved
Cargo pump housing had a prior weld repair that was layered in epoxy "JB Weld" material. Required owner to remove epoxy and make permanent repairs.
Condition: Damaged By Earlier Event
Due 20 October 2011
Resolved 12 October 2011
Resolution: Pump housing permenantly repaired.
Engineering › Diesel Engine (auxiliary) › Piping (exhaust)
Issued 20 September 2011 Resolved
Cargo pump prime mover exhaust lagging was saturated in oil. Oil appeared to be accumulation of exhaust blow by. Required owner to replace exhaust lagging.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 12 October 2011
Resolution: Exhaust lagging replaced.
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Cargo Manifold
Issued 20 September 2011 Resolved
Cargo piping had a hydrostatic testing date of 2007. Owner could not produce documentation showing a current test had been performed Required vessel to complete annual 150% MAWP hydrostatic test. MAWP of piping was 80 psi.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 12 October 2011
Resolution: Hydrostatic testing was completed and piping stenciled.
Documentation › Certificates/Documents › Certificate of Financial Responsibility
Issued 25 August 2010 Resolved
COFR expired 06AUG10. Must have Valid COFR on board IAW 33 CFR138.65. Renew COFR
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 25 October 2010
Resolution: Vsl has valid COFR (confirmed via MISLE COFR Link).
Deck/Cargo › Towing › Chocks
Issued 27 June 2006 Resolved
Replace 10 kevels on deck area. Kevels are seriously wasted and beyond repair.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 23 April 2007
Construction/Loadline › Hull › Bracket
Issued 27 June 2006 Resolved
Replace port navigation screen bracket.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 19 September 2006
Stability › Weathertight Integrity › General
Issued 27 June 2006 Resolved
Replace hinges and handle on weather tight access cover to pump room.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 19 September 2006
Deck/Cargo › Towing › Chocks
Issued 27 June 2006 Resolved
Replace 10 kevels (cleats) on deck of barge. Kevels are seriously deteriated and beyond repair.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 19 September 2006
Documentation › Certificates/Documents › Certificate of Inspection
Issued 10 March 2006 Resolved
Vessel operated without a Valid COI.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 23 August 2007
Resolution: New COI issued.
Pollution Prevention/Response › Prevention Equipment
Issued 31 October 2002 Resolved
Crop & renew both containments. LEGACY COMPONENT DESC: Fixed Containment
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 30 November 2002
Resolved 7 November 2002
Deck/Cargo › Cargo Stowage
Issued 31 October 2002 Resolved
Provide & install flame screen on goose neck vent. LEGACY COMPONENT DESC: Flame screen
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 30 November 2002
Resolved 7 November 2002
Construction/Loadline › Markings
Issued 31 October 2002 Resolved
Paint draft marks & vessel name. LEGACY COMPONENT DESC: Draft Marks/Indicating System
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 30 November 2002
Resolved 7 November 2002
Construction/Loadline › Structures
Issued 31 October 2002 Resolved
Attach scuttles to vessel. LEGACY COMPONENT DESC: Scuttle
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 30 November 2002
Resolved 7 November 2002
Deck/Cargo › Cargo Transfer/Lightering (liquid)
Issued 31 October 2002 Resolved
Install guard over belts on cargo pump below deck. LEGACY COMPONENT DESC: Pumproom
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 30 November 2002
Resolved 7 November 2002
Engineering › Diesel Engine (auxiliary)
Issued 31 October 2002 Resolved
Install exhaust blanket on exhaust pipe. LEGACY COMPONENT DESC: Piping (exhaust)
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 30 November 2002
Resolved 7 November 2002
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 20 February 2002 Resolved
Stanchions for deck lights on bow were not welded to the deck.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 27 February 2002
Resolution: Stanchions were welded to the deck.
Accommodation/Occupational Safety › Ventilation
Issued 20 February 2002 Resolved
Flame screen on #2 starboard cargo tank ullage opening needed to be replaced. LEGACY COMPONENT DESC: Flame Screens
Action required: 17 - Rectify deficiencies prior to departure
Resolved 27 February 2002
Resolution: Flame screen replaced.
Engineering › Fuel Oil Service System › Piping
Issued 20 February 2002 Resolved
Diesel line from diesel tank to prime mover for pump needed shut-off valve next to engine.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 27 February 2002
Resolution: Valve installed.
Documentation
Issued 17 November 1994 Resolved
PROVIDE ON BOARD AN APPROVED VESSEL RESPONSE PLAN.
Condition: Unknown
Due 17 November 1994
Resolved 17 November 1994
Deck/Cargo
Issued 17 November 1992 Resolved
PRIOR TO TRANSFER OF CARGO MAKE AVAILABLE FOR INSPECTION THE VESSELS OIL_x001C_ TRANSFER PROCEDURES AS REQUIRED BY 33CFR 155.720.
Condition: Unknown
Due 1 December 1992
Resolved 2 December 1992

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.