Inspection history · 40
17 March 2022
Type not recorded
No type recorded · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7418448
14 December 2012
Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 4502379
13 December 2012
Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 4525406
16 January 2002
MARPOL Annex II Examination
Physical examination · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 1479091
3 September 1999
Administrative
Administrative · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 785209
15 October 1997
Deficiency Check
Physical examination · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 1120828
24 September 1997
Hull Examination
Physical examination · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 778505
25 June 1997
Administrative
Administrative · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 1112709
2 April 1997
Deficiency Check
Physical examination · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 1106823
31 March 1997
Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1097345
28 February 1997
Damage Survey · Re-Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1377973
26 February 1996
Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 885127
20 February 1996
Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1189298
15 December 1995
COI Inspection
Physical examination · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 779581
15 December 1995
COI Inspection · Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 872970
13 February 1995
Administrative
Administrative · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 840300
9 November 1994
Administrative
Administrative · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 869746
15 September 1994
Hull Examination
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1440852
22 November 1993
COI Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1151848
16 July 1993
Damage Survey
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 846648
14 July 1993
Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 173475
10 March 1993
Re-Inspection · Hull Examination
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1148961
28 February 1992
Deficiency Check
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 955431
31 December 1991
COI Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 944172
26 February 1991
Re-Inspection
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1232591
25 January 1990
Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1219672
19 January 1990
Hull Examination · COI Inspection
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1231413
12 May 1989
Administrative
Administrative · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1033672
26 January 1989
COI Inspection
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 896865
24 February 1988
Re-Inspection
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1021913
19 February 1987
COI Inspection · Hull Examination
Physical examination · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 1016905
19 December 1986
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1004881
12 December 1986
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1310215
17 September 1986
Deficiency Check
Physical examination · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1005628
15 August 1986
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1005736
15 August 1986
COI Inspection
Physical examination · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1309553
7 December 1985
Re-Inspection
Physical examination · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 1299692
18 September 1984
Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1282496
18 February 1982
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1279544
23 November 1981
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1272047
Construction/Loadline
Issued 24 September 1997
Resolved
Complete worklist of items issued 9/23 and 9/24 during internal structural exam.
Condition: Unknown
Due 9 February 1998
Resolved 9 February 1998
Documentation
Issued 28 February 1997
Resolved
PROPERLY DISPLAY OIL POLLUTION PLACARD.
Condition: Unknown
Due 28 February 1997
Resolved 28 February 1997
Construction/Loadline
Issued 28 February 1997
Resolved
CROP AND RENEW ALL STEPS AND STRINGERS AS NEEDED.
Condition: Unknown
Due 28 February 1997
Resolved 28 February 1997
Construction/Loadline
Issued 28 February 1997
Resolved
STRAIGHTEN OR CROP AND RENEW LIFELINE STANCHIONS AS REQUIRED.
Condition: Unknown
Due 28 February 1997
Resolved 28 February 1997
Electrical
Issued 28 February 1997
Resolved
REMOVE PORTABLE BATTERY CHARGER AND REPLACE WITH U/L LISTED AND APPROVED TYPE FOR MARINE USE.
Condition: Unknown
Due 28 February 1997
Resolved 28 February 1997
Fire Fighting
Issued 28 February 1997
Resolved
PROVIDE PROOF OF ANNUAL SERVICING OF PORTABLE BII FIRE EXTINGUISHER.
Condition: Unknown
Due 28 February 1997
Resolved 28 February 1997
Documentation
Issued 15 December 1995
Resolved
Provide copy of COFR. Vessel may not carry fuel for the generator until this is cleared.
Condition: Unknown
Due 15 December 1997
Resolved 15 February 1996
Documentation
Issued 15 December 1995
Resolved
Provide copy of the LOVELAND BARGE 3001 grain loading book to local OCMI. Vessel may not load grain until this requirement is cleared.
Condition: Unknown
Due 15 December 1995
Resolved 15 December 1995
Engineering
Issued 15 December 1995
Resolved
Insulate exhaust pipe for generator.
Condition: Unknown
Due 29 December 1995
Resolved 16 January 1996
Documentation
Issued 15 December 1995
Resolved
Provide copy of stability letter.
Condition: Unknown
Due 29 December 1995
Resolved 16 January 1996
Documentation
Issued 15 December 1995
Resolved
Submit plans to local OCMI for portable generator installation.
Condition: Unknown
Due 29 December 1995
Resolved 16 January 1996
Fire Fighting
Issued 15 December 1995
Resolved
Provide and properly mount one (1) B-II fire extinguisher in the generator space.
Condition: Unknown
Due 29 December 1995
Resolved 16 January 1996
Electrical
Issued 15 December 1995
Resolved
Provide corrosive resistant battery box for generator.
Condition: Unknown
Due 29 December 1995
Resolved 16 January 1996
Navigation
Issued 22 November 1993
Resolved
PROVE PROPER OPERATION OF AFT NAVIGATION LIGHT.
Condition: Unknown
Due 23 November 1993
Resolved 23 November 1993
Engineering
Issued 31 December 1991
Resolved
PRIOR TO OPERATION (RUNNING) INSTALLED PORTABLE GASOLINE GENERATOR, REPLACESPARK PLUG WIRE. (MELTED TAPED UP)_x001C_ _x001C_ _x001C_
Condition: Unknown
Due 8 January 1992
Resolved 8 January 1992
Engineering
Issued 31 December 1991
Resolved
PRIOR TO OPERATION (RUNNING) THE INSTALLED PORTABLE GASOLING GENERATOR, TIGHTEN LOOSE EXHAUST SYSTEM AT ENGINE CONNECTION.
Condition: Unknown
Due 31 January 1992
Resolved 8 January 1992
Electrical
Issued 31 December 1991
Resolved
PRIOR TO OPERATION (RUNNING) THE INSTALLED PORTABLE GASOLINE GENERATOR, REPLACE MELTED PLUG CONNECTION ON GENERATOR PART OF UNIT. (SHORTED OUT, UNSAFE)
Condition: Unknown
Due 31 January 1992
Resolved 8 January 1992
Engineering
Issued 31 December 1991
Resolved
PRIOR TO OPERATION (RUNNING) OF INSTALLED PORTABLE GASOLINE GENERATOR, PROVIDE BACK FIRE PROTECTION FOR ENGINE. (NONE INSTALLED)
Condition: Unknown
Due 31 January 1992
Resolved 8 January 1992
Engineering
Issued 31 December 1991
Resolved
PRIOR TO OPERATION (RUNNING) OF THE INSTALLED PORTABLE GASOLINE GENERATOR, REPAIR/RENEW OIL TANK ON ENGINE, REMOVE RAG, REPAIR SENSOR WIRES. (TANK HOLED)
Condition: Unknown
Due 8 January 1992
Resolved 8 January 1992
Construction/Loadline
Issued 31 December 1991
Resolved
COMPLETE ITEMS 1-5 ON ATTACHED CG WORKLIST FOR HULL AND MAIN DECK RELATED ITEMS.
Condition: Unknown
Due 31 January 1992
Resolved 8 January 1992
Engineering
Issued 31 December 1991
Resolved
PROIR TO USE OF GASOLINE ENGINE ON BOARD SHOW COMPLIANCEW WITH 46 CFR SUBCHAPTER J, OR REMOVE ENGINE FROM VESSEL. COMPLIANCE TO BE SHOWN TO ATTENDING MARINE INSPECTOR.
Condition: Unknown
Due 31 December 1991
Resolved 31 December 1991
Engineering
Issued 31 December 1991
Resolved
PROIR TO USE OF GASOLINE ENGINE ONBOARD SHOW COMPLIANCE WITH 46CFR 58.10, OR REMOVE ENGINE FROM VESSEL. COMPLIANCE TO BE SHOWN TO ATTENDING MARINE INSPECTOR.
Condition: Unknown
Due 31 December 1991
Resolved 31 December 1991
Construction/Loadline
Issued 19 January 1990
Resolved
PRIOR TO LOADING CARGO. PROVIDE FOR INSPECTION AND TEST INSTALLED AND HATCHCOVERS. BARGE SHALL BE LIMITED TO AN INLAND ROUTE UNTIL HATCH COVERS HAVE BEEN INSPECTED.
Condition: Unknown
Due 19 January 1990
Resolved 19 January 1990
Construction/Loadline
Issued 19 January 1990
Resolved
CROPPED AND RENEWED PORT BOW RAKE BOTTOM PLATE A STRAKE BETWEEN FRAME #4 AND FRAME #5. APPROX. 54" X 52" X 9/16".
Condition: Unknown
Due 19 January 1990
Resolved 19 January 1990
Construction/Loadline
Issued 19 January 1990
Resolved
CROPPED AND RENEWED STBD BOW RAKE BOTTOMPLATE, B STRAKE FROM FRAME #4 TO #6 FRAME, AND D STRAKE BETWEEN FRAME #6 AND #7. APPROX. 6' X 13'6" X 9/16" AND 76" X 48" X 9/16".
Condition: Unknown
Due 19 January 1990
Resolved 19 January 1990
Unknown
Issued 15 August 1986
Resolved
REPAINT LOADLINE MARKINGS.
Condition: Unknown
Due 15 August 1986
Resolved 15 August 1986
Unknown
Issued 15 August 1986
Resolved
FLAME SCREENS OF CORROSION RESISTENT 30X30 INCH MESH WIRE SHALL BE INSTALLED ON THE AFT STOWAGE COMPARTMENT VENTS.
Condition: Unknown
Due 15 August 1986
Resolved 15 August 1986
Unknown
Issued 15 August 1986
Resolved
FREE-UP AND GREASE ALL HATCH COVER DOGS, INCLUDING THE HOPPER W.T.H DOGS. ALSO, FREE-UP AND GREASE THE AFT ANCHOR CABLE REEL.
Condition: Unknown
Due 15 August 1986
Resolved 15 August 1986
Unknown
Issued 15 August 1986
Resolved
RENEW ELECTRICAL CABLE TO STARBOARD RUNNING LIGHT.
Condition: Unknown
Due 15 August 1986
Resolved 15 August 1986
Unknown
Issued 15 August 1986
Resolved
REPLACE RECEPTACLE OUTLETS WITH ONES DESIGNED SO THAT WHEN THE PLUG IS IN, THE PLUG IS HELD IN POSITIVE CONTACT AND ESTABLISHES AND MAINTAINS A WATERTIGHT ENCLOSURE.
Condition: Unknown
Due 15 August 1986
Resolved 15 August 1986
Unknown
Issued 15 August 1986
Resolved
PROVIDE PROPER LIGHT SCREENS FOR ALL LOCATIONS. PAINT MAT BLACK. ALSO, THE AFT LIGHT STAND MUST BE STRAIGHTENED.
Condition: Unknown
Due 15 August 1986
Resolved 15 August 1986
Unknown
Issued 15 August 1986
Resolved
AN ICC SPECIFICATION CONTAINER, ASME CONTAINER, OR PORTABLE SAFETY CONTAINER HAVING THE APPROVAL OF A RECOGNIZED TESTING LABORATORY MAY BE STOWED IN THE AFT STORAGE COMPARTMENT PROVIDED IT DOES NOT EXCEED FIVE (5) GALLONS CAPACITY.
Condition: Unknown
Due 15 August 1986
Resolved 15 August 1986
Navigation
Issued 15 August 1986
Resolved
RENEW ELECTRICAL CABLE TO STBD RUNNING LIGHT. COMPLIANCE DATE IS 15SEP86.
Condition: Unknown
Due 15 August 1986
Resolved 15 August 1986
Electrical
Issued 15 August 1986
Resolved
REPLACE RECEPTACLE OUTLETS WITH ONES DESIGNED SO THAT WHEN THE PLUG IS IN, THE PLUG IS HELD IN POSITIVE CONTACT AND ESTABLISHES AND MAINTAINS A WATER-TIGHT ENCLOSURE. COMPLIANCE DATE IS 15SEP86.
Condition: Unknown
Due 15 August 1986
Resolved 15 August 1986
Construction/Loadline
Issued 15 August 1986
Resolved
REPAINT LOADLINE MARKINGS. COMPLIANCE DATE IS 15SEP86.
Condition: Unknown
Due 15 August 1986
Resolved 15 August 1986
Navigation
Issued 15 August 1986
Resolved
PROVIDE PROPER LIGHT SCREENS FOR ALL LOCATIONS. PAINT MAT BLACK. ALSO, THE AFT LIGHT STAND MUST BE STRAIGHTEN. COMPLIANCE DATE IS 15SEP86.
Condition: Unknown
Due 15 August 1986
Resolved 15 August 1986
Electrical
Issued 15 August 1986
Resolved
AN ICC SPECIFICATION CONTAINER, ASME CONTAINER, OR PORTABLE SAFETY CONTAINER HAVING THE APPROVAL OF A RECOGNIZED TESTING LABORATORY MAY BE STOWED IN THE AFT STORAGE COMPT. PROVIDED IT DOES NOT EXCEED FIVE (5) GALLONS CAPACITY. COMPLIANCE DATE IS 15SEP86.
Condition: Unknown
Due 15 August 1986
Resolved 15 August 1986
Deck/Cargo
Issued 15 August 1986
Resolved
FLAME SCREENS OF CORROSION RESISTENT 30X30 INCH MESH WIRE SHALL BE INSTALLED ON THE AFT STOWAGE COMPT. VENTS. COMPLIANCE DATE IS 15SEP86.
Condition: Unknown
Due 15 August 1986
Resolved 15 August 1986
Construction/Loadline
Issued 15 August 1986
Resolved
FREE-UP AND GREASE ALL HATCH COVER DOGS, INCLUDING THE HOPPER W.T.H. DOGS. ALSO, FREE-UP AND GREASE THE AFT ANCHOR CABLE REEL. COMPLIANCE DATE IS 15SEP86.
Condition: Unknown
Due 15 August 1986
Resolved 15 August 1986