MAURY USCG vessel records
← All vessels

G.T. CARGOMASTER

Built
1977
Last inspected
17 March 2022
Documentation
Valid · NVDC file of 10 August 2026
Controls
None recorded without a removal date

This record may be incomplete: the most recent inspection recorded for this vessel was 4 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Barge class in Maury's sources begin in 1972.

Inspection record

Last inspected 17 March 2022
…with no type recorded11
Operational controls None recorded without a removal date
Years with a record 20 calendar years (1981–2022)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

Flag
UNITED STATES
Maury page id
psix-53462

Documentation record

Registered dimensions (L × B × D)288.0 ft × 43.5 ft × 23.0 ft
Registered tonnagegross 2,612 / net 2,612
ITC dimensions (L × B × D)288.0 ft × 43.5 ft × 23.0 ft
ITC tonnagegross 2,422 / net 1,575
BuilderTIDEWATER EQUIPMENT CORPORTION · CHESAPEAKE, VA, UNITED STATES · built 1977
Hull materialSteel
PropulsionUNSPECIFIED
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing portPHILADELPHIA, PA
Endorsements, as the file codes themcw_un, reg
DocumentationValid · issued 12 September 2025 · expires 30 September 2026
Service, as the file records itFreight Barge
Hull formbarge (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it2422 - Convention (Subpart B), Gross Ton
2612 - Regulatory (Subpart C or D), Gross Ton
1575 - Convention (Subpart B), Net Ton
2612 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Professional
The full record for this vessel

Behind this panel: 40 inspections, each with its date, unit and type; 39 deficiencies with the resolution recorded against each; operational controls, none recorded without a removal date; 12 other vessels inspected with it; no other recorded names; the documentation record: dimensions, tonnage, builder, hailing port and endorsements. Every line is a record the Coast Guard wrote; the counts above are the same counts as in the summary, and they are free.

Professional is $39 a month or $299 a year, or $19.99 a month locked for life at the founding rate, for the first 200 subscribers. It unlocks every detail section on every vessel page, fleet watch tied to your account, and ownership records on request. Already a subscriber? Sign in.

Maury does not score, rate or grade vessels, at any price.

Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 1972 to 2026, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspected as a tow unit · 12

Inspection history · 40

17 March 2022 Type not recorded
No type recorded · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7418448
14 December 2012 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 4502379
13 December 2012 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 4525406
16 January 2002 MARPOL Annex II Examination
Physical examination · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 1479091
3 September 1999 Administrative
Administrative · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 785209
15 October 1997 Deficiency Check
Physical examination · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 1120828
24 September 1997 Hull Examination
Physical examination · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 778505
25 June 1997 Administrative
Administrative · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 1112709
2 April 1997 Deficiency Check
Physical examination · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 1106823
31 March 1997 Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1097345
28 February 1997 Damage Survey · Re-Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1377973
26 February 1996 Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 885127
20 February 1996 Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1189298
15 December 1995 COI Inspection
Physical examination · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 779581
15 December 1995 COI Inspection · Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 872970
13 February 1995 Administrative
Administrative · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 840300
9 November 1994 Administrative
Administrative · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 869746
15 September 1994 Hull Examination
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1440852
22 November 1993 COI Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1151848
16 July 1993 Damage Survey
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 846648
14 July 1993 Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 173475
10 March 1993 Re-Inspection · Hull Examination
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1148961
28 February 1992 Deficiency Check
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 955431
31 December 1991 COI Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 944172
26 February 1991 Re-Inspection
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1232591
25 January 1990 Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1219672
19 January 1990 Hull Examination · COI Inspection
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1231413
12 May 1989 Administrative
Administrative · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1033672
26 January 1989 COI Inspection
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 896865
24 February 1988 Re-Inspection
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1021913
19 February 1987 COI Inspection · Hull Examination
Physical examination · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 1016905
19 December 1986 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1004881
12 December 1986 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1310215
17 September 1986 Deficiency Check
Physical examination · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1005628
15 August 1986 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1005736
15 August 1986 COI Inspection
Physical examination · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1309553
7 December 1985 Re-Inspection
Physical examination · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 1299692
18 September 1984 Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1282496
18 February 1982 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1279544
23 November 1981 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1272047

Deficiency record · 39

Construction/Loadline
Issued 24 September 1997 Resolved
Complete worklist of items issued 9/23 and 9/24 during internal structural exam.
Condition: Unknown
Due 9 February 1998
Resolved 9 February 1998
Documentation
Issued 28 February 1997 Resolved
PROPERLY DISPLAY OIL POLLUTION PLACARD.
Condition: Unknown
Due 28 February 1997
Resolved 28 February 1997
Construction/Loadline
Issued 28 February 1997 Resolved
CROP AND RENEW ALL STEPS AND STRINGERS AS NEEDED.
Condition: Unknown
Due 28 February 1997
Resolved 28 February 1997
Construction/Loadline
Issued 28 February 1997 Resolved
STRAIGHTEN OR CROP AND RENEW LIFELINE STANCHIONS AS REQUIRED.
Condition: Unknown
Due 28 February 1997
Resolved 28 February 1997
Electrical
Issued 28 February 1997 Resolved
REMOVE PORTABLE BATTERY CHARGER AND REPLACE WITH U/L LISTED AND APPROVED TYPE FOR MARINE USE.
Condition: Unknown
Due 28 February 1997
Resolved 28 February 1997
Fire Fighting
Issued 28 February 1997 Resolved
PROVIDE PROOF OF ANNUAL SERVICING OF PORTABLE BII FIRE EXTINGUISHER.
Condition: Unknown
Due 28 February 1997
Resolved 28 February 1997
Documentation
Issued 15 December 1995 Resolved
Provide copy of COFR. Vessel may not carry fuel for the generator until this is cleared.
Condition: Unknown
Due 15 December 1997
Resolved 15 February 1996
Documentation
Issued 15 December 1995 Resolved
Provide copy of the LOVELAND BARGE 3001 grain loading book to local OCMI. Vessel may not load grain until this requirement is cleared.
Condition: Unknown
Due 15 December 1995
Resolved 15 December 1995
Engineering
Issued 15 December 1995 Resolved
Insulate exhaust pipe for generator.
Condition: Unknown
Due 29 December 1995
Resolved 16 January 1996
Documentation
Issued 15 December 1995 Resolved
Provide copy of stability letter.
Condition: Unknown
Due 29 December 1995
Resolved 16 January 1996
Documentation
Issued 15 December 1995 Resolved
Submit plans to local OCMI for portable generator installation.
Condition: Unknown
Due 29 December 1995
Resolved 16 January 1996
Fire Fighting
Issued 15 December 1995 Resolved
Provide and properly mount one (1) B-II fire extinguisher in the generator space.
Condition: Unknown
Due 29 December 1995
Resolved 16 January 1996
Electrical
Issued 15 December 1995 Resolved
Provide corrosive resistant battery box for generator.
Condition: Unknown
Due 29 December 1995
Resolved 16 January 1996
Navigation
Issued 22 November 1993 Resolved
PROVE PROPER OPERATION OF AFT NAVIGATION LIGHT.
Condition: Unknown
Due 23 November 1993
Resolved 23 November 1993
Engineering
Issued 31 December 1991 Resolved
PRIOR TO OPERATION (RUNNING) INSTALLED PORTABLE GASOLINE GENERATOR, REPLACESPARK PLUG WIRE. (MELTED TAPED UP)_x001C_ _x001C_ _x001C_
Condition: Unknown
Due 8 January 1992
Resolved 8 January 1992
Engineering
Issued 31 December 1991 Resolved
PRIOR TO OPERATION (RUNNING) THE INSTALLED PORTABLE GASOLING GENERATOR, TIGHTEN LOOSE EXHAUST SYSTEM AT ENGINE CONNECTION.
Condition: Unknown
Due 31 January 1992
Resolved 8 January 1992
Electrical
Issued 31 December 1991 Resolved
PRIOR TO OPERATION (RUNNING) THE INSTALLED PORTABLE GASOLINE GENERATOR, REPLACE MELTED PLUG CONNECTION ON GENERATOR PART OF UNIT. (SHORTED OUT, UNSAFE)
Condition: Unknown
Due 31 January 1992
Resolved 8 January 1992
Engineering
Issued 31 December 1991 Resolved
PRIOR TO OPERATION (RUNNING) OF INSTALLED PORTABLE GASOLINE GENERATOR, PROVIDE BACK FIRE PROTECTION FOR ENGINE. (NONE INSTALLED)
Condition: Unknown
Due 31 January 1992
Resolved 8 January 1992
Engineering
Issued 31 December 1991 Resolved
PRIOR TO OPERATION (RUNNING) OF THE INSTALLED PORTABLE GASOLINE GENERATOR, REPAIR/RENEW OIL TANK ON ENGINE, REMOVE RAG, REPAIR SENSOR WIRES. (TANK HOLED)
Condition: Unknown
Due 8 January 1992
Resolved 8 January 1992
Construction/Loadline
Issued 31 December 1991 Resolved
COMPLETE ITEMS 1-5 ON ATTACHED CG WORKLIST FOR HULL AND MAIN DECK RELATED ITEMS.
Condition: Unknown
Due 31 January 1992
Resolved 8 January 1992
Engineering
Issued 31 December 1991 Resolved
PROIR TO USE OF GASOLINE ENGINE ON BOARD SHOW COMPLIANCEW WITH 46 CFR SUBCHAPTER J, OR REMOVE ENGINE FROM VESSEL. COMPLIANCE TO BE SHOWN TO ATTENDING MARINE INSPECTOR.
Condition: Unknown
Due 31 December 1991
Resolved 31 December 1991
Engineering
Issued 31 December 1991 Resolved
PROIR TO USE OF GASOLINE ENGINE ONBOARD SHOW COMPLIANCE WITH 46CFR 58.10, OR REMOVE ENGINE FROM VESSEL. COMPLIANCE TO BE SHOWN TO ATTENDING MARINE INSPECTOR.
Condition: Unknown
Due 31 December 1991
Resolved 31 December 1991
Construction/Loadline
Issued 19 January 1990 Resolved
PRIOR TO LOADING CARGO. PROVIDE FOR INSPECTION AND TEST INSTALLED AND HATCHCOVERS. BARGE SHALL BE LIMITED TO AN INLAND ROUTE UNTIL HATCH COVERS HAVE BEEN INSPECTED.
Condition: Unknown
Due 19 January 1990
Resolved 19 January 1990
Construction/Loadline
Issued 19 January 1990 Resolved
CROPPED AND RENEWED PORT BOW RAKE BOTTOM PLATE A STRAKE BETWEEN FRAME #4 AND FRAME #5. APPROX. 54" X 52" X 9/16".
Condition: Unknown
Due 19 January 1990
Resolved 19 January 1990
Construction/Loadline
Issued 19 January 1990 Resolved
CROPPED AND RENEWED STBD BOW RAKE BOTTOMPLATE, B STRAKE FROM FRAME #4 TO #6 FRAME, AND D STRAKE BETWEEN FRAME #6 AND #7. APPROX. 6' X 13'6" X 9/16" AND 76" X 48" X 9/16".
Condition: Unknown
Due 19 January 1990
Resolved 19 January 1990
Unknown
Issued 15 August 1986 Resolved
REPAINT LOADLINE MARKINGS.
Condition: Unknown
Due 15 August 1986
Resolved 15 August 1986
Unknown
Issued 15 August 1986 Resolved
FLAME SCREENS OF CORROSION RESISTENT 30X30 INCH MESH WIRE SHALL BE INSTALLED ON THE AFT STOWAGE COMPARTMENT VENTS.
Condition: Unknown
Due 15 August 1986
Resolved 15 August 1986
Unknown
Issued 15 August 1986 Resolved
FREE-UP AND GREASE ALL HATCH COVER DOGS, INCLUDING THE HOPPER W.T.H DOGS. ALSO, FREE-UP AND GREASE THE AFT ANCHOR CABLE REEL.
Condition: Unknown
Due 15 August 1986
Resolved 15 August 1986
Unknown
Issued 15 August 1986 Resolved
RENEW ELECTRICAL CABLE TO STARBOARD RUNNING LIGHT.
Condition: Unknown
Due 15 August 1986
Resolved 15 August 1986
Unknown
Issued 15 August 1986 Resolved
REPLACE RECEPTACLE OUTLETS WITH ONES DESIGNED SO THAT WHEN THE PLUG IS IN, THE PLUG IS HELD IN POSITIVE CONTACT AND ESTABLISHES AND MAINTAINS A WATERTIGHT ENCLOSURE.
Condition: Unknown
Due 15 August 1986
Resolved 15 August 1986
Unknown
Issued 15 August 1986 Resolved
PROVIDE PROPER LIGHT SCREENS FOR ALL LOCATIONS. PAINT MAT BLACK. ALSO, THE AFT LIGHT STAND MUST BE STRAIGHTENED.
Condition: Unknown
Due 15 August 1986
Resolved 15 August 1986
Unknown
Issued 15 August 1986 Resolved
AN ICC SPECIFICATION CONTAINER, ASME CONTAINER, OR PORTABLE SAFETY CONTAINER HAVING THE APPROVAL OF A RECOGNIZED TESTING LABORATORY MAY BE STOWED IN THE AFT STORAGE COMPARTMENT PROVIDED IT DOES NOT EXCEED FIVE (5) GALLONS CAPACITY.
Condition: Unknown
Due 15 August 1986
Resolved 15 August 1986
Navigation
Issued 15 August 1986 Resolved
RENEW ELECTRICAL CABLE TO STBD RUNNING LIGHT. COMPLIANCE DATE IS 15SEP86.
Condition: Unknown
Due 15 August 1986
Resolved 15 August 1986
Electrical
Issued 15 August 1986 Resolved
REPLACE RECEPTACLE OUTLETS WITH ONES DESIGNED SO THAT WHEN THE PLUG IS IN, THE PLUG IS HELD IN POSITIVE CONTACT AND ESTABLISHES AND MAINTAINS A WATER-TIGHT ENCLOSURE. COMPLIANCE DATE IS 15SEP86.
Condition: Unknown
Due 15 August 1986
Resolved 15 August 1986
Construction/Loadline
Issued 15 August 1986 Resolved
REPAINT LOADLINE MARKINGS. COMPLIANCE DATE IS 15SEP86.
Condition: Unknown
Due 15 August 1986
Resolved 15 August 1986
Navigation
Issued 15 August 1986 Resolved
PROVIDE PROPER LIGHT SCREENS FOR ALL LOCATIONS. PAINT MAT BLACK. ALSO, THE AFT LIGHT STAND MUST BE STRAIGHTEN. COMPLIANCE DATE IS 15SEP86.
Condition: Unknown
Due 15 August 1986
Resolved 15 August 1986
Electrical
Issued 15 August 1986 Resolved
AN ICC SPECIFICATION CONTAINER, ASME CONTAINER, OR PORTABLE SAFETY CONTAINER HAVING THE APPROVAL OF A RECOGNIZED TESTING LABORATORY MAY BE STOWED IN THE AFT STORAGE COMPT. PROVIDED IT DOES NOT EXCEED FIVE (5) GALLONS CAPACITY. COMPLIANCE DATE IS 15SEP86.
Condition: Unknown
Due 15 August 1986
Resolved 15 August 1986
Deck/Cargo
Issued 15 August 1986 Resolved
FLAME SCREENS OF CORROSION RESISTENT 30X30 INCH MESH WIRE SHALL BE INSTALLED ON THE AFT STOWAGE COMPT. VENTS. COMPLIANCE DATE IS 15SEP86.
Condition: Unknown
Due 15 August 1986
Resolved 15 August 1986
Construction/Loadline
Issued 15 August 1986 Resolved
FREE-UP AND GREASE ALL HATCH COVER DOGS, INCLUDING THE HOPPER W.T.H. DOGS. ALSO, FREE-UP AND GREASE THE AFT ANCHOR CABLE REEL. COMPLIANCE DATE IS 15SEP86.
Condition: Unknown
Due 15 August 1986
Resolved 15 August 1986

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.