Records from 1981 to 2026. Most recent: inspection, 6 May 2026.
Documentation record
Registered dimensions (L × B × D)48.0 ft × 15.0 ft × 5.6 ft
Registered tonnagegross 26 / net 18
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderNEUVILLE BOAT WORKS, INC. · LOREAUVILLE, LA, UNITED STATES · built 1981
Hull materialAluminum
PropulsionDiesel Reduction
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portNEW ORLEANS, LA
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 4 March 2026 · expires 30 April 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it26 - Regulatory (Subpart C or D), Gross Ton
18 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Inspection history · 46
6 May 2026
Annual Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 8349596
3 April 2025
Examination of Repairs · COI Inspection · Drydock Exam
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 8104345
28 March 2025
Drydock Exam · COI Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 8092402
7 March 2024
Annual Inspection · Internal Structural Exam
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7864445
14 March 2023
Annual Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7644944
14 March 2022
Annual Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7409394
21 January 2021
Annual Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7128546
11 March 2020
Internal Structural Exam · COI Inspection · MTSA Verification · Drydock Exam
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6916844
19 March 2019
Annual Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6638955
13 March 2018
Annual Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6367031
4 April 2017
Annual Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6114286
25 March 2016
Annual Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 5838837
21 March 2014
Annual Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 4817380
26 February 2010
COI Inspection · Drydock Exam
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3685935
2 April 2009
Annual Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3440732
28 February 2008
COI Inspection · Administrative Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3150331
3 April 2007
Annual Inspection · Administrative Inspection · Deficiency Check
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 2900950
4 May 2006
Administrative Inspection · Annual Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 2640319
24 February 2005
Annual Inspection · Hull Examination
Physical examination · MIDET EAST BANK DETAIL · USCG Heartland District (CGD-H) · Activity 2297776
23 March 2004
Annual Inspection
Physical examination · MIDET EAST BANK DETAIL · USCG Heartland District (CGD-H) · Activity 2029476
12 February 2003
COI Inspection
Physical examination · MIDET EAST BANK DETAIL · USCG Heartland District (CGD-H) · Activity 1742895
14 February 2002
Annual Inspection
Physical examination · MIDET EAST BANK DETAIL · USCG Heartland District (CGD-H) · Activity 1486480
17 January 2001
Re-Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1466191
20 April 2000
Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1051017
6 March 2000
Administrative
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 815792
1 February 2000
COI Inspection · Hull Examination · Examination of Repairs
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1413620
26 March 1999
Administrative
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1115576
27 February 1999
Damage Survey
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 799129
26 February 1999
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 182796
15 April 1998
COI Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1465367
17 April 1997
Re-Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1421301
24 April 1996
Re-Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1412959
20 April 1995
COI Inspection · Hull Examination
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1425574
7 April 1994
Re-Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1426890
2 April 1993
Re-Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1391830
1 May 1992
COI Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 943538
26 April 1991
Re-Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1306977
9 August 1990
Hull Examination · Re-Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 925326
26 May 1989
Hull Examination · COI Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1347005
13 May 1988
Re-Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1041505
9 October 1987
Re-Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1014079
19 December 1986
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1003468
22 May 1986
Credit Drydock · COI Inspection
Physical examination · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1302510
21 November 1984
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 976810
24 May 1983
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 965369
16 November 1981
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 967566
07 - Fire Safety › N/A - No Subsystem › Ventilation
Issued 14 March 2023
Resolved
The discharge ends of vent pipes shall be fitted with removable flame screens or flame arresters. The flame screens shall consist of a single screen of corrosion resistant wire of at least 30 X 30 mesh. Ventilation pipe for diesel fuel tank lacking removable flame screen. Install new flame screen to satisfaction of attending MI.
46 CFR 182.20-35(d)
Action required: 10 - Deficiency Rectified
Due 14 March 2023
Resolved 14 March 2023
Resolution: Vessel installed new flame mesh screen on diesel fuel tank ventilation pipe.
04 - Emergency Systems › N/A - No Subsystem › Abandon ship drills
Issued 14 March 2023
Resolved
Abandon ship and man overboard drills and training shall be logged or otherwise documented for review by the Coast Guard upon request. The drill entry shall include the following information: (1) Date of the drill and training; and (2) General description of the drill scenario and training topics. Inadequate log entries missing description and location of where drills are being conducted. Properly document full description of conducted drills.
46 CFR 185.520(f)
Condition: Invalid
Action required: 10 - Deficiency Rectified
Due 14 March 2023
Resolved 14 March 2023
Resolution: Vessel corrected logs, providing full description of completed drills.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 14 March 2023
Resolved
Tanks, tank vents and other appurtenances, piping and pipe fittings shall be checked. Return line on fuel tank found with leakage at fitting connection. Tighten or replace fitting on return line.
46 CFR 176.25-10(a)(5)
Action required: 10 - Deficiency Rectified
Due 14 March 2023
Resolved 14 March 2023
Resolution: Vessel tightened fitting where leak was identified.
09 - Working and Living Conditions › 092 - Working Conditions › Cleanliness of engine room
Issued 14 March 2023
Resolved
The marine inspector shall examine the bilges and other spaces to see that there is no accumulation of oil or other matter which might create a fire hazard. Excessive fuel and water mixture identified in the bilge of centerline void where diesel fuel tank is located. Remove and clean contents from bilge.
46 CFR 176.25-50(b)
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 14 March 2023
Resolved 14 March 2023
Resolution: Vessel removed/cleaned fuel and water mixture from bilge.
09 - Working and Living Conditions › 092 - Working Conditions › Machinery
Issued 14 March 2023
Resolved
Marine inspector shall examine all accessible parts of the exterior and interior of the hull, watertight bulkheads, and weather deck. Holes found on the pilothouse deck plating on both port and starboard side. Fill and secure.
46 CFR 176.25-5(a)(1)
Action required: 10 - Deficiency Rectified
Due 14 March 2023
Resolved 14 March 2023
Resolution: Vessel installed plugs in pilothouse deck plating.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 14 March 2023
Resolved
All vessels of 26 feet in length and over shall be provided with individual bilge lines and bilge suctions for each watertight compartment. Forward void bilge suction found inoperable and unable to draw suction.
46 CFR 182.25-5(a)
Condition: Invalid
Action required: 10 - Deficiency Rectified
Due 14 March 2023
Resolved 14 March 2023
Resolution: Vessel able to repair forward void bilge suction. Tested and found fully operational.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 14 March 2023
Resolved
Where the life preservers are stowed so that they are not readily visible to passengers, the containers in which they are stowed shall be marked "life preservers" and with the number contained therein, in at least 1-inch letters and figures. Storage area of life preservers found not marked with the number of preservers stored in each individual location. Mark each stowage area with appropriate number.
46 CFR 180.25-15(b)
Action required: 10 - Deficiency Rectified
Due 14 March 2023
Resolved 14 March 2023
Resolution: Stowage locations adequately marked and labeled with the correct number or preservers stowed in each respective location.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 14 March 2022
Resolved
The fixed power bilge pump shall be self-priming and may be driven off the main engine or other source of power. The Marine Inspector observed the bilge pump did not function when tested.
Cite: 46 CFR 182.25-5 (b) [Old T]
Action required: 10 - Deficiency Rectified
Due 14 March 2022
Resolved 14 March 2022
Resolution: The impeller had wasted as did the cable/fuse providing power to the pump. Both repairs were made on the spot.
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Service
Issued 4 April 2017
Resolved
The B-I and B-II portable FF extinguisher was last serviced on 17MAR2017.
Action required: 701 - Prior to carriage of passengers/cargo
Due 4 April 2017
Resolved 4 April 2017
Resolution: Company purchased 3 new extinguishers service April 2017 and they stated they placed them on board the vessel.
Operations/Management › Drug and Alcohol Testing › EAP Display Requirements
Issued 4 April 2017
Resolved
Could not provide proof they were enrolled in an Employee Assistance Program. The phone numbers provided were to a local travel/promotion company.
Action required: 705 - Other - as specified
Due 11 April 2017
Resolved 5 April 2017
Resolution: Vessel rep was able to provide the contact info for the EAP rep. Confirmed infro. All sat.
Engineering › Fuel Oil Service System › Hose
Issued 26 February 2010
Resolved
Replace non SAE-1942 hose from fuel tank fill to fuel tank with a SAE 1942 hose.
Action required: 705 - Other - as specified
Due 1 March 2010
Resolved 26 February 2010
Resolution: Replaced non SAE-1942 hose from fuel tank fill to fuel tank with a SAE 1942 hose.
Engineering › Shafting/Propeller Arrangements › Coupling
Issued 26 February 2010
Resolved
Repair/replace loose stbd. shaft coupling. Shaft was turning inside of the coupling.
Action required: 705 - Other - as specified
Due 2 March 2010
Resolved 26 February 2010
Resolution: Repaired loose stbd. shaft coupling.
Deck/Cargo › Holds/Tanks › Bulkhead
Issued 3 April 2007
Resolved
Properly repair hole located in forepeak, starboard side, 1st frame back, between 2nd and 3rd longitudinal, and air test in the presence and to the satisfaction of a marine inspector.
Condition: Unknown
Action required: 705 - Other - as specified
Due 13 May 2007
Resolved 16 April 2007
Resolution: Repaired with 6" diameter insert. Tested satisfactory.
Documentation
Issued 1 February 2000
Resolved
UPON RECEIPT OF SIGNED STABILITY LETTER, POST UNDER GLASS SO THAT ALL PAGESARE VISIBLE FROM THE OPERATING STATION.
Condition: Unknown
Due 1 February 2000
Resolved 1 February 2000
Documentation
Issued 1 February 2000
Resolved
PROVIDE UPDATED CERTIFICATE OF DOCUMENTATION TO REFLECT BOAT'S INCREASED LENGTH TO 48' AS A RESULT OF MODIFICATIONS.
Condition: Unknown
Due 1 February 2000
Resolved 1 February 2000