SUN DAY

SUN DAY is a 1982 passenger vessel (inspected). The Coast Guard has recorded 17 inspections since 2016, most recently in July 2026, along with 56 deficiencies and 2 casualty investigations between 2008 and 2021.

Records from 2008 to 2026. Most recent: inspection, 16 July 2026.

Built
1982
Last inspected
16 July 2026
Documentation
Valid · documentation file of 10 August 2026
Controls
None recorded without a removal date

Everything above is free. The detail below — the inspection history, the deficiency record, the tow units, the casualty record and the documentation record — is Professional, $39 a month. Sign in.

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 16 July 2026
…with no type recorded3
Operational controls None recorded without a removal date
Years with a record 10 calendar years (2016–2026)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

WDC8625
Flag
UNITED STATES
Maury page id
psix-53593

Documentation record

Registered dimensions (L × B × D)104.0 ft × 25.1 ft × 7.2 ft
Registered tonnagegross 96 / net 65
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderGULF CRAFT INC · PATTERSON, LA, UNITED STATES · built 1982
Hull materialAluminum
PropulsionDiesel Reduction
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing portNEW ORLEANS, LA
Trade endorsementsCoastwise, unrestricted, Registry
DocumentationValid · issued 18 April 2026 · expires 31 May 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it96 - Regulatory (Subpart C or D), Gross Ton
65 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Professional
Detail on this page

17 inspections, each with its date, unit and type; 56 deficiencies with the resolution recorded against each; 1 vessel inspected with it, by name and date; 2 casualty investigations, with date and classification; the documentation record: dimensions, tonnage, builder, hailing port, endorsements, dates. The counts in the summary above are the same counts, and they are free.

$39 a month or $299 a year, every vessel page, cancel any time. Founding rate $19.99 a month for life, for the first 200 subscribers. Plans Sign in

Maury does not score, rate or grade vessels, at any price.

Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 2016 to 2026 for this class, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspected as a tow unit · 1

The Coast Guard recorded this vessel and the following in the same inspection activity — normally a tug and the barges in its tow. A recreational or unclassed hull in the same activity is held and not published, so it does not appear here: these lists are a floor, not a complete manifest.

THUY TRANG Commercial Fishing Vessel · MISLE 251915 · 28 April 2021 · activity 7184709

Inspection history · 17

16 July 2026 Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 8439514
24 June 2026 Internal Structural Exam · Annual Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 8395145
14 March 2026 Type not recorded
No type recorded · Station Grand Isle · USCG Heartland District (CGD-H) · Activity 8326102
30 July 2025 Drydock Exam · Annual Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 8179705
23 July 2024 Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7964921
18 June 2024 Annual Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7918555
26 July 2023 Drydock Exam · Internal Structural Exam · Annual Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7727362
28 June 2022 COI Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7470039
23 July 2021 Deficiency Check · Drydock Exam · Annual Inspection · Internal Structural Exam · Examination of Repairs
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7253388
28 April 2021 Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7184709
30 July 2020 Annual Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7001057
11 September 2019 Drydock Exam · Examination of Repairs
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6802593
26 June 2019 Internal Structural Exam · Annual Inspection · Drydock Extension
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6726811
16 October 2018 Administrative Inspection · Deficiency Check · In-Service Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6562518
16 July 2018 Administrative Inspection · Annual Inspection · Deficiency Check
Physical examination · Marine Safety Unit Lafayette · USCG Heartland District (CGD-H) · Activity 6482126
19 July 2016 Deficiency Check · Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 5946852
16 June 2016 Type not recorded
No type recorded · Station Sabine · USCG Heartland District (CGD-H) · Activity 5910378

Deficiency record · 56

07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 18 August 2025 Resolved
Spaces must be equipped with a fire detection and alarm system of an approved type installed in accordance with 46 CFR part 76. MI observed that the fire detection system on the bridge was not serviced. 46CFR181.405(a)
Action required: 60 - Rectify deficiencies prior to movement
Due 18 August 2025
Resolved 18 August 2025
Resolution: Servicing report received. All sat.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 18 August 2025 Resolved
All vessels shall be provided with a satisfactory arrangement for draining any watertight compartment. The bilge pump for the lazerette was inoperable. 46 CFR 182.25-1 (Old T)
Action required: 17 - Rectify deficiencies prior to departure
Due 18 August 2025
Resolved 18 August 2025
Resolution: Received detailed video of Bilge system running properly. All sat.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 18 August 2025 Resolved
If your vessel's Certificate of Inspection is renewed less often than annually, the marine inspector must check the settings of the safety or relief valves on all pressure vessels, except cargo tanks, twice every 5 years. No more than 3 years may elapse between any check and its immediate predecessor. MI was unable to verify latest inspection of pressure vessel safety relief valves. 46 CFR 61.10-5(i)(2)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 September 2025
Resolved 19 August 2025
Resolution: New inspected valves installed. All sat.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 18 August 2025 Resolved
A closed fresh water system may be used to cool the engine. MI observed a jacket water leak on the jacket water head tank for the port side generator. 46 CFR 182.20-10(2) (Old T)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 September 2025
Resolved 19 August 2025
Resolution: J/W head tank sight glass replaced. All sat.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 30 July 2025 Resolved
Vessels described by 46 CFR 175.110(c) must have an interconnected fire detection system in compliance with § 181.450 installed in all enclosed areas where passengers and crew have routine access, including accommodation spaces. MI observed the fire detectors in crew accommodation space were not installed and were missing batteries. 46 CFR 181.405(c)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 September 2025
Resolved 19 August 2025
Resolution: Blue tooth smoke detectors added and verified. All sat.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 18 June 2024 Resolved
Installation shall be in accordance with 182.15-15. (182.15-15) That part of the exhaust system between the point of cooling water injection and the engine manifold shall be water jacketed or or effectively insulated. MI witnessed exhaust lagging before the water cooling jet on the FWD Port engine missing.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 July 2024
Resolved 19 June 2024
Resolution: Received email pictures of wrap around exhaust. All sat.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 15 August 2023 Resolved
It is further intended that all machinery be installed and maintained in such a manner as to afford adequate protection against fire, explosion, machinery failure and personnel injury. Marine inspector (MI) found STBD generator main seal leaking. 46CFR182.01-5
Action required: 60 - Rectify deficiencies prior to movement
Resolved 17 August 2023
Resolution: MI attended vessel inspected and tested generator main seal. All sat
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 15 August 2023 Resolved
All electrical installations shall be to the satisfaction of the Officer in Charge, Marine Inspection. Emergency lighting bulbs were found burnt out. 46CFR183.01-15(a)60
Action required: 60 - Rectify deficiencies prior to movement
Resolved 17 August 2023
Resolution: All emergency lighting bulbs were replaced and now working appropriately. all sat
08 - Alarms › N/A - No Subsystem › Emergency signal
Issued 15 August 2023 Resolved
All electrical installations shall be to the satisfaction of the Officer in Charge, Marine Inspection. During a test of the general alarm, MI saw no flashing light indicator for alarm system in engine room. Ensure required general alarm visual indicators are present and operable. 46CFR183.01-15(a)
Action required: 60 - Rectify deficiencies prior to movement
Resolved 17 August 2023
Resolution: MI attended vessel inspected and tested generator main seal. All sat
02 - Structural Conditions › N/A - No Subsystem › Steering gear
Issued 15 August 2023 Resolved
All vessels except non-self-propelled vessels shall be provided with suitable steering apparatus. MI witnessed leaks in hydraulic steering system. 46CFR182.30-1(a)
Action required: 60 - Rectify deficiencies prior to movement
Resolved 17 August 2023
Resolution: MI attended vessel inspected and tested generator main seal. All sat
08 - Alarms › N/A - No Subsystem › Emergency signal
Issued 15 August 2023 Resolved
Except as further modified in this section, where fire extinguishing systems or equipment are not required, but are installed, the system or equipment and its installation shall meet the requirements of this part. MI witnessed trouble alarm on fire detection panel flashing as well as unlabeled detection zones. Label fire detection zones and provide a report from a certified technician attesting to trouble alarm servicing and proper operation of fire protection panel. 46CFR181.05-5(a)
Action required: 60 - Rectify deficiencies prior to movement
Resolved 17 August 2023
Resolution: Recieved tech report attesting to the repair. Fire alarm panel is in proper operation and is working. all sat
07 - Fire Safety › N/A - No Subsystem › Operation of Fire protection systems
Issued 15 August 2023 Resolved
Except as further modified in this section, where fire extinguishing systems or equipment are not required, but are installed, the system or equipment and its installation shall meet the requirements of this part. MI witnessed broken handle on fire hydrant. 46CFR181.05-5(a)
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 17 August 2023
Resolution: Handle has been replaced and installed on fire hydrant. all sat
05 - Radio Communications › N/A - No Subsystem › Satellite EPIRB 406MHz/1.6GHz
Issued 15 August 2023 Resolved
The EPIRB required in § 180.40-1 of this subchapter is tested monthly, using the integrated test circuit and output indicator, to determine that it is operative. EPIRB monthly testing was not recorded in log books. 46CFR185.25-20(a)
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 17 August 2023
Resolution: Epirb has been tested and documented accordingly. all sat
04 - Emergency Systems › N/A - No Subsystem › Abandon ship drills
Issued 15 August 2023 Resolved
The master shall conduct drills and give instructions as necessary to ensure that all crew members are familiar with their duties. Routine drills had not been logged in accordance with emergency instructions to the satisfaction of the OCMI. 46CFR185.25-10
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 17 August 2023
Resolution: Drills have been conducted and are starting to be logged accordingly. All sat
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 15 August 2023 Resolved
The inspection and maintenance of the equipment listed in paragraph (a) of this section shall be logged or otherwise documented for review by the Coast Guard upon request. Survival craft maintenance was not documented. 46CFR185.702(d)
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 17 August 2023
Resolution: Survival craft maintenance has been conducted and documented accordingly. all sat.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 15 August 2023 Resolved
Each rescue boat and ring life buoy must be marked with Type II retroreflective material approved in accordance with 46 CFR 164.018 or other standard specified by the Commandant. MI witnessed worn retoreflective material on ring buoys. Replace to the satisfaction of CG MI. 46CFR185.604(h)
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 17 August 2023
Resolution: Reflective material has been replaced on ring buoys. all sat
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 15 August 2023 Resolved
The Commandant may, after suitable investigations and tests, accept fire fighting equipment, which is of a type not contemplated by the regulations in this part, if the safety of the vessel is materially improved thereby. Engine room did not contain any integrated smoke detection system. Ensure vessel comes into compliance with MSIB 05-23 to the satisfaction of CG MI. 46CFR181.05-5
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 6 September 2023
Resolution: Recieved video from rep of integrated detection.
09 - Working and Living Conditions › 091 - Living Conditions › Electrical devices
Issued 15 August 2023 Resolved
All electrical installations shall be to the satisfaction of the Officer in Charge, Marine Inspection. MI witnessed engine room distribution panel breakers did not correspond with their respective labeled amperages. 46CFR183.01-15(a)
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 17 August 2023
Resolution: Breakers have been labeled and corrected. all sat
09 - Working and Living Conditions › 092 - Working Conditions › Guards - fencing around dangerous machinery parts
Issued 15 August 2023 Resolved
It is further intended that all machinery be installed and maintained in such a manner as to afford adequate protection against fire, explosion, machinery failure and personnel injury. MI witnessed guard missing on #2 generator. 46CFR182.01-5
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 17 August 2023
Resolution: Guard has been installed. all sat
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 15 August 2023 Resolved
Except as otherwise provided in this section, all vessels shall be provided with not less than two avenues of escape from all general areas accessible to the passengers or where the crew may be quartered or normally employed, so located that if one is not available the other may be. Emergency escape door in the generator room was seized. 46CFR177.15-1(a)
Action required: 10 - Deficiency Rectified
Resolved 15 August 2023
Resolution: Escape door unseized
11 - Life Saving Appliances › N/A - No Subsystem › Stowage and provision of liferafts
Issued 15 August 2023 Resolved
Stowing of life floats and buoyant apparatus must allow easy launching. MI witnessed tangled grab lines on survival craft equipment. 46CFR180.20-1
Action required: 10 - Deficiency Rectified
Resolved 15 August 2023
Resolution: Grab lines untangled and organized
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 15 August 2023 Resolved
Except as otherwise provided in this section, all vessels shall be provided with not less than two avenues of escape from all general areas accessible to the passengers or where the crew may be quartered or normally employed, so located that if one is not available the other may be. Emergency escape area was being used as a storage space for miscellaneous vessel equipment. 46CFR177.15-1(a)
Action required: 10 - Deficiency Rectified
Resolved 15 August 2023
Resolution: Equipment removed
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 15 August 2023 Resolved
Except as otherwise provided in this section, all vessels shall be provided with not less than two avenues of escape from all general areas accessible to the passengers or where the crew may be quartered or normally employed, so located that if one is not available the other may be. MI noticed watertight door alarm was covered rendering alarm inoperable. 46CFR177.15-1(a)
Action required: 10 - Deficiency Rectified
Resolved 15 August 2023
Resolution: Cover removed from alarm
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 28 June 2022 Resolved
A vessel must be provided with a main steering gear that is of adequate strength and capable of steering the vessel at all service speeds. Identified hydraulic lines weeping at operating station. Repair leaks to the satisfaction of the attending marine inspector.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 6 July 2022
Resolution: Vessel rectified steering gear leaks under console.
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 28 June 2022 Resolved
On or before March 11, 1999; an existing vessel must comply with the bilge high level alarm requirements in 182.530. Bilge high level alarm in lazerette was inoperable.
Condition: Improper Installation
Action required: 10 - Deficiency Rectified
Resolved 28 June 2022
11 - Life Saving Appliances › N/A - No Subsystem › Rigid liferafts
Issued 28 June 2022 Resolved
Life floats. Each life float must be fitted with a lifeline, pendants, two paddles, a painter, and a light. The middle life float needs new lifeline; lifeline was found to be frayed/worn.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 6 July 2022
Resolution: Vessel replaced #2 lifefloat.
11 - Life Saving Appliances › N/A - No Subsystem › Rigid liferafts
Issued 28 June 2022 Resolved
Life floats. Each life float must be fitted with a lifeline, pendants, two paddles, a painter, and a light.One of three life float lights attached need to be replaced with compliant batteries for approved floating waterlight under 161.010.
Condition: Improper Installation
Action required: 10 - Deficiency Rectified
Resolved 28 June 2022
03 - Water/Weathertight Conditions › N/A - No Subsystem › Doors
Issued 28 June 2022 Resolved
Except when operating on lakes, bays, and sounds or rivers routes in clam weather, all hatches and openings in the hull, except loading doors, of a vessel must be kept tightly closed except when being used. Dogs on weathertight hatch on rear bulkhead of accomodation space need to be tightened to ensure closure.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 5 July 2022
Resolution: Vessel tightened hatch on weathertight door.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 28 June 2022 Resolved
All unfired pressure vessels must be installed to the satisfaction of the OCMI. The design, construction and original testing of such unfired pressure vessels must meet the applicable requirements of subchapter F (Marine Engineering) of this Chapter. Gauge on port side air compressor only goes to 200 PSI; MAWP on tank is also 200 PSI; replace gauge to the satisfaction of the attending Marine Inspector.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 5 July 2022
Resolution: Vessel piped water heater into bilge.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 28 June 2022 Resolved
When a vessel is equipped with two or more generators to supply ship's service power, the following requirements must be met: The generator circuit breakers must be interlocked to prevent the generators from being simultaneously connected to the switchboard. Generator interlock is missing.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 15 July 2022
Resolution: Interlock working properly.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 28 June 2022 Resolved
Whenever there is a hazardous condition, as defined by 175.400 of this chapter, on board the vessel the owner, master, agent or person in charge shall immediately notify the COTP of the port or place in which the vessel is located of the hazardous condition. Hot water heater relief shall be piped into bilge.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 5 July 2022
Resolution: Vessel replaced air receiver gauge with 300 psi gauge.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 12 August 2021 Resolved
Vsl must be marked IAW 46 CFR part 67. Vessel name and hailing port must be marked on the stern of the vessel. Missing stern area marking of vsl name and hailing port.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 August 2021
Resolved 26 August 2021
Resolution: VSL name and hailing port painted on to the stern of the vsl.
08 - Alarms › N/A - No Subsystem › Fire alarm
Issued 10 August 2021 Resolved
Fire extinguishing equipment installed on a vessel in excess of the requirements of 46CFR181.400 and 181.500 must be designed, constructed, installed, and maintained in accordance with a recognized industry standard acceptable to the Commandant (CG-ENG). Note 46 CFR 181.400 talks to Detection systems. Also New installations of fire protection equipment on an existing vessel, which are completed to the satisfaction of the OCMI on or after March 11, 1986, must comply with the regulation of this part.(New T-boat regs). Provide documentation/inspection tag showing the fire detection system has been inspected and functioning in accordance with manufacture recommendations.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 August 2021
Resolved 26 August 2021
Resolution: Third party attended to inspect, repair and satisfactorily certify the fire detection system. Heat senor located about #3 MDE was replaced. All sat.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 10 August 2021 Resolved
Life Ring located on the aft pilothouse deck was found with water intrusion, effecting its buoyancy, due to damaged shell plug. Replace in kind.
Action required: 17 - Rectify deficiencies prior to departure
Due 10 August 2021
Resolved 12 August 2021
Resolution: Life ring replace with new life ring. All sat.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 23 July 2021 Resolved
Shore power connection box, located in the aft aux room, was found with housing broken and exposing personnel to the potential electrical hazards for the 220 electrical system. Replace connection box with suitable approved type.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 August 2021
Resolved 26 August 2021
Resolution: Shore power receptacle repaired. All sat.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 30 July 2020 Resolved
Exhaust gas must not leak from the piping or any connections. The piping must be properly supported by non-combustible hangers or blocks. #3 engine exhaust flexible piping had a 2" x 5" hole in it, leaking exhaust in the engine room. #1 and #2 generators exhaust lines are not properly supported, they were missing bolts in hangers. SUN DAY shall replace or repair the faulty flexible exhaust pipe, #1 and #2 generator hanger bolts to the satisfaction of the Coast Guard Marine Inspector.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 31 July 2020
Resolved 31 July 2020
Resolution: SUN DAY replaced the faulty flexible exhaust pipe, and #1 and #2 generator hanger bolts to the satisfaction of the Coast Guard Marine Inspector.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 23 October 2018 Resolved
Sewage pump cable had a connection that is not of the pressure type that meets UL486A. Replace connections at the splicing with the appropriate connectors.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 8 November 2018
Resolved 6 November 2018
Resolution: Replaced connections with one of the pressure type.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 16 October 2018 Resolved
At each inspection for certification and at every other vessel inspection the bilges and other spaces may be examined to see that there is no excessive accumulation of oil, trash, debris, or other matter that might create a fire hazard, clog bilge pumping systems, or block emergency escapes. Engine and generator bilges were found with excessive fuel, oil and water in bilges. Pump all bilges dry, test machinery for leaks and make repairs accordingly prior to vessel's departure.
Action required: 60 - Rectify deficiencies prior to movement
Due 16 October 2018
Resolved 18 October 2018
Resolution: Vessel personnel removed all water, fuel, oil and debri from the bilge. Bilges are clean and dry.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 16 October 2018 Resolved
Fuel supply valve coming out of fuel tank has a leak on the valve stem. Complete repairs in order to stop fuel from leaking from valve.
Action required: 60 - Rectify deficiencies prior to movement
Due 23 October 2018
Resolved 23 October 2018
Resolution: Packing on valve stem was found to be loose. Adjusted packing gland, tested valve for leaks with satisfactory results.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 16 October 2018 Resolved
Fuel water separator "Racor" was found to have a leak on the bowl on the Starboard center engine. Complete repairs in order to stop the fuel leak.
Action required: 60 - Rectify deficiencies prior to movement
Due 23 October 2018
Resolved 23 October 2018
Resolution: Seal on the bottom of the bowl was found to be defective. A new seal was installed and system was tested with satisfactory results.
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 16 July 2018 Resolved
Rescue platform did not have a means of being secured to vessel.
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Due 17 July 2018
Resolved 17 July 2018
Resolution: Rescue platform was equipped with chain to secure to gunwale.
05 - Radio Communications › N/A - No Subsystem › Functional requirements
Issued 16 July 2018 Resolved
Primary radio was not equipped with digital select calling capability.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 July 2018
Resolved 17 July 2018
Resolution: 3rd party radio company enabled DSC on radio.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Doors
Issued 16 July 2018 Resolved
Forward engine room watertight door hand wheel was loose.
Action required: 17 - Rectify deficiencies prior to departure
Due 16 July 2018
Resolved 17 July 2018
Resolution: Door hand wheel was repaired.
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 16 July 2018 Resolved
Fire monitor suction pipe seachest valve hand wheel was not attached.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 23 July 2018
Resolved 17 July 2018
Resolution: Hand wheel attached.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Manholes/flush scuttles
Issued 16 July 2018 Resolved
Man hole covers were not stenciled to keep clear.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 23 July 2018
Resolved 17 July 2018
Resolution: Escape scuttles were stenciled.
11 - Life Saving Appliances › N/A - No Subsystem › Means of rescue
Issued 16 July 2018 Resolved
Crewmember's rigger harness did not have a long enough tag line for climbing down onto the rescue platform.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 16 July 2018
Resolved 17 July 2018
Resolution: Tag line for harness provided.
Construction/Loadline › Structures › Scupper
Issued 19 July 2016 Resolved
Port and Starboard quarters each had cracked welds where the main deck joins the bulwarks near the scuppers.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 26 July 2016
Resolved 1 August 2016
Resolution: Weld repairs completed.
Communications › Radio Communications › VHF Radiotelephone
Issued 19 July 2016 Resolved
VHF radio's Digital Selective Calling feature was not functional/operational.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 26 July 2016
Resolved 19 July 2016
Resolution: VHF DSC made functional/operational by a licensed radio technician.
Communications › Radio Communications › Radiotelephone Transceiver (2-4 MHz)
Issued 19 July 2016 Resolved
Did not have a NAVTEX receiver; must have one installed or reduce route to <100NM.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 26 July 2016
Resolved 1 August 2016
Resolution: O/O request via letter to reduce vessel's route to 100NM from shore.
Communications › Audible Communications › Bell
Issued 19 July 2016 Resolved
Did not have the correct sized bell (11.8" or 300mm).
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 26 July 2016
Resolved 19 July 2016
Resolution: Installed mounting bracket and 11.8" bell.
Lifesaving › Lifejacket/PFD (Type I) › Lights
Issued 19 July 2016 Resolved
Several lights were missing a metal pin which does not allow the light to function as manufactured.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 26 July 2016
Resolved 1 August 2016
Resolution: PML's on affected lifejackets were corrected.
Lifesaving › Lifebuoys › Serviceable
Issued 19 July 2016 Resolved
2 ring lifebouys had worn out retro-reflective tape which needed to be replaced.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 26 July 2016
Resolved 19 July 2016
Resolution: Placed new retro-reflective material on the ring lifebuoys.
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 19 July 2016 Resolved
Light was not attached around the body of the buoy.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 19 July 2016
Resolved 19 July 2016
Resolution: Corrected on the spot.
Lifesaving › Lifefloat › Floating Electric Waterlight
Issued 19 July 2016 Resolved
3 floating lights were not attached around the body of the lifefloats, and were not marked with the name of the vessel.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 19 July 2016
Resolved 19 July 2016
Resolution: Corrected on the spot.
Lifesaving › Rescue Boat › Embarkation/Disembarkation Capabilities
Issued 19 July 2016 Resolved
Rescue platform had steel shackles with excessive corrosion, solid deck plate instead of a grated deck plate, and demensions were less than 36" X 36".
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 2 August 2016
Resolved 1 August 2016
Resolution: Rescue platform steel shackles replaced with stainless steel shackles, solid plate deck replaced with fiberglass grating meeting the minimum size requirements.
Lifesaving › Lifejacket/PFD (Type I) › Storage
Issued 19 July 2016 Resolved
PFD stowage compartments were not clearly marked to reflect the correct number of PFDs stored inside each respective compartment.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 26 July 2016
Resolved 19 July 2016
Resolution: PFD storage bins were properly marked to reflect the correct number of PFDs stored in each. Satisfactorily corrected.

Casualty record · 2

11 May 2008Routine · role: Involved in a Marine Casualty · serious marine incident, as classified · activity 3204148
28 April 2021Routine · role: Transiting Vicinity of Primary Subject · activity 7184709
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.