Records from 1994 to 2026. Most recent: inspection, 16 April 2026.
Inspection history · 157
16 April 2026
Deficiency Check · COI Inspection · MTSA/ISPS Verification
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 8340093
8 April 2026
Deficiency Check · Administrative Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 8344465
2 April 2026
Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 8357343
19 March 2026
In-Service Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 8328954
5 March 2026
Deficiency Check · Administrative Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 8320220
5 March 2026
Type not recorded
No type recorded · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 8361724
24 February 2026
Deficiency Check · Administrative Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 8315323
10 February 2026
Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 8309854
25 January 2026
Administrative Inspection
Administrative · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 8301980
23 January 2026
Administrative Inspection
Administrative · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 8300671
5 January 2026
Type not recorded
No type recorded · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 8320114
29 October 2025
Type not recorded
No type recorded · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 8261264
30 August 2025
Administrative Inspection · Deficiency Check
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 8220801
8 July 2025
Administrative Inspection
Administrative · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 8179820
12 June 2025
ACP Annual Oversight · Annual Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 8129153
24 February 2025
Administrative Inspection
Administrative · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 8084038
8 October 2024
Deficiency Check · Administrative Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 8026420
1 October 2024
Explosive Handling Operation-Commercial · Explosive Handling Operation-Administrative
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 8012531
30 September 2024
Explosive Handling Operation-Administrative
Administrative · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 8011968
17 September 2024
Explosive Handling Operation-Commercial · Explosive Handling Operation-Administrative
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 8004448
12 July 2024
Periodic Inspection · Deficiency Check · ACP Periodic Oversight · MTSA/ISPS Verification
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7957064
12 July 2024
Administrative Inspection
Administrative · Commandant (CG-5P-TI) · Activity 7961363
6 July 2024
Explosive Handling Operation-Commercial
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7950961
25 June 2024
Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7942679
23 June 2024
Explosive Handling Operation-Commercial
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7940404
19 June 2024
In-Service Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7939125
19 June 2024
Type not recorded
No type recorded · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7959217
13 June 2024
Explosive Handling Operation-Commercial · Explosive Handling Operation-Administrative
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7934094
28 May 2024
Explosive Handling Operation-Commercial
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7922780
25 May 2024
Explosive Handling Operation-Commercial
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7922841
18 May 2024
Explosive Handling Operation-Administrative · Explosive Handling Operation-Commercial
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7911773
30 April 2024
Explosive Handling Operation-Commercial · Explosive Handling Operation-Administrative
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7903921
20 February 2024
ACP Additional Oversight – Risk Assessment
Administrative · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7868708
10 November 2023
Administrative Inspection
Administrative · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7822929
27 October 2023
Administrative Inspection
Administrative · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7815550
4 October 2023
In-Service Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7803443
4 October 2023
Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7815411
15 September 2023
Administrative Inspection · Deficiency Check
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7792533
17 August 2023
ACP Annual Oversight · Annual Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7727609
25 May 2023
Explosive Handling Operation-Administrative · Explosive Handling Operation-Commercial
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7759068
18 May 2023
Explosive Handling Operation-Commercial
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7692316
3 May 2023
Administrative Inspection
Administrative · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7680174
22 April 2023
Explosive Handling Operation-Commercial
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7673523
11 April 2023
Explosive Handling Operation-Commercial · Explosive Handling Operation-Administrative
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7666889
10 April 2023
Administrative Inspection · Deficiency Check
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7670517
10 April 2023
Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7701916
7 April 2023
Administrative Inspection · ACP Additional Oversight – Risk Assessment
Administrative · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7664524
10 March 2023
Administrative Inspection
Administrative · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7648967
10 March 2023
Administrative Inspection
Administrative · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7648997
9 March 2023
Administrative Inspection
Administrative · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7648541
9 March 2023
Administrative Inspection
Administrative · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7648572
9 March 2023
Administrative Inspection
Administrative · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7648580
9 March 2023
Administrative Inspection
Administrative · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7648602
9 March 2023
Administrative Inspection
Administrative · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7648612
9 March 2023
Administrative Inspection
Administrative · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7648615
8 March 2023
Administrative Inspection
Administrative · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7647725
7 March 2023
Administrative Inspection
Administrative · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7647297
12 October 2022
Type not recorded
No type recorded · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7583205
5 October 2022
Explosive Handling Operation-Commercial · Explosive Handling Operation-Administrative
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7572092
7 September 2022
Explosive Handling Operation-Administrative
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7553847
12 August 2022
Deficiency Check
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7532010
3 August 2022
Deficiency Check · Annual Inspection · ACP Annual Oversight · Administrative Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7489080
15 July 2022
Administrative Inspection
Administrative · Activities Far East · USCG Oceania District (CGD-O) · Activity 7507179
28 March 2022
Type not recorded
No type recorded · Activities Far East · USCG Oceania District (CGD-O) · Activity 7452525
26 March 2022
Type not recorded
No type recorded · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7425435
15 March 2022
Type not recorded
No type recorded · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7422480
14 June 2021
COI Inspection · MTSA/ISPS Verification
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7225523
1 February 2021
Administrative Inspection
Administrative · Activities Far East · USCG Oceania District (CGD-O) · Activity 7133880
25 January 2021
ACP Drydock Oversight
Administrative · Marine Inspections Unit Singapore · USCG Oceania District (CGD-O) · Activity 7129988
7 January 2021
Administrative Inspection · Periodic Inspection · ACP Periodic Oversight
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7120971
10 November 2020
Administrative Inspection
Administrative · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7093488
4 November 2020
Administrative Inspection
Administrative · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7095073
30 October 2020
Administrative Inspection
Administrative · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7087494
21 October 2020
Deficiency Check · Administrative Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7081725
15 June 2020
Explosive Handling Operation-Administrative
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6977724
1 June 2020
Explosive Handling Operation-Administrative
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6965568
18 May 2020
Explosive Handling Operation-Administrative
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6955448
6 May 2020
Explosive Handling Operation-Administrative
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6949255
7 April 2020
Explosive Handling Operation-Administrative
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6936461
23 March 2020
Explosive Handling Operation-Administrative
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6930721
10 March 2020
Explosive Handling Operation-Administrative · Explosive Handling Operation-Commercial
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6923838
25 February 2020
Explosive Handling Operation-Administrative
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6915364
3 February 2020
In-Service Inspection · Annual Inspection · ACP Annual Oversight · MTSA/ISPS Verification
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6904773
28 January 2020
Explosive Handling Operation-Administrative
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6897869
14 January 2020
Explosive Handling Operation-Administrative
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6889201
16 December 2019
Explosive Handling Operation-Administrative
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6875003
7 December 2019
Explosive Handling Operation-Commercial
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6865941
18 November 2019
Explosive Handling Operation-Administrative
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6858099
2 November 2019
Type not recorded
No type recorded · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6850278
21 October 2019
Explosive Handling Operation-Administrative
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6839194
8 October 2019
Explosive Handling Operation-Administrative
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6830730
29 September 2019
Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6823478
29 September 2019
Examination of Repairs
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6839170
28 August 2019
Explosive Handling Operation-Administrative
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6797562
20 August 2019
Explosive Handling Operation-Administrative
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6789780
30 July 2019
Explosive Handling Operation-Administrative
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6767889
15 July 2019
Explosive Handling Operation-Administrative
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6751355
9 July 2019
Administrative Inspection
Administrative · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6743339
9 July 2019
Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6959203
17 June 2019
Explosive Handling Operation-Administrative
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6717220
5 June 2019
Administrative Inspection
Administrative · Commandant (CG-5P-TI) · Activity 6704601
5 June 2019
ACP Periodic Oversight · Administrative Inspection · Periodic Inspection · Deficiency Check
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6704971
4 June 2019
Explosive Handling Operation-Administrative
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6703380
20 May 2019
Explosive Handling Operation-Administrative
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6688986
6 May 2019
Explosive Handling Operation-Administrative
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6678329
22 April 2019
Explosive Handling Operation-Administrative
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6668076
8 April 2019
Explosive Handling Operation-Administrative
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6658514
26 March 2019
Explosive Handling Operation-Administrative
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6649347
11 March 2019
Explosive Handling Operation-Administrative
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6640466
26 February 2019
Explosive Handling Operation-Administrative
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6632618
12 February 2019
Explosive Handling Operation-Administrative
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6624617
2 February 2019
Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6616973
29 January 2019
Explosive Handling Operation-Administrative
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6616801
15 January 2019
Explosive Handling Operation-Administrative
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6610593
2 January 2019
Explosive Handling Operation-Commercial
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6604801
17 December 2018
Explosive Handling Operation-Administrative
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6599167
1 November 2018
MARPOL Annex V Examination · Annual Inspection · MARPOL Annex I Examination · Administrative Inspection · ACP Annual Oversight · Deficiency Check
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6544379
23 May 2018
Administrative Inspection · Deficiency Check · ACP Additional Oversight – Risk Assessment
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6422390
28 March 2018
Type not recorded
No type recorded · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6389200
12 March 2018
Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6370651
28 February 2018
Administrative Inspection · Deficiency Check
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6363700
17 January 2018
Administrative Inspection · Deficiency Check · Damage Survey
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6339174
3 January 2018
Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6332589
1 January 2018
Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6333661
18 December 2017
Administrative Inspection
Administrative · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6326511
21 November 2017
Re-Inspection · Administrative Inspection · COI Inspection · Deficiency Check
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6295172
7 November 2017
Administrative Inspection
Administrative · Commandant (CG-5P-TI) · Activity 6302185
12 October 2017
Drydock Exam
Physical examination · Activities Far East · USCG Oceania District (CGD-O) · Activity 6236991
14 August 2017
Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6240466
12 August 2017
Type not recorded
No type recorded · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6240795
31 July 2017
Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6226608
19 July 2017
Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6213801
5 July 2017
Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6198911
19 June 2017
Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6180521
6 June 2017
Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6167669
23 May 2017
Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6153342
17 May 2017
Administrative Inspection
Administrative · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6148056
10 May 2017
Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6143160
6 May 2017
Type not recorded
No type recorded · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6141642
25 April 2017
Type not recorded
No type recorded · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6131945
24 April 2017
Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6131797
12 April 2017
Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6122738
4 April 2017
Administrative Inspection · Damage Survey
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6117365
31 March 2017
Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6116765
28 March 2017
Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6112980
20 March 2017
In-Service Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6108710
28 February 2017
Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6098097
13 February 2017
Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6087458
12 February 2017
Ballast Water Examination · ACP Annual Oversight · Administrative Inspection · Annual Inspection · Security Breach
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6085714
28 November 2016
Administrative Inspection
Administrative · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6048867
8 October 2016
Damage Survey
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6018890
20 August 2016
Periodic Inspection · Examination of Repairs · ACP Periodic Oversight
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 5979809
19 June 2016
Administrative Inspection · Damage Survey
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 5917161
6 June 2016
Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 5899587
22 April 2016
Examination of Repairs
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 5859885
20 January 2016
Administrative Inspection
Administrative · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 5799470
20 January 2016
ACP Annual Oversight
Administrative · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 5799576
14 - Pollution Prevention › 141 - MARPOL Annex I › Oil discharge monitoring and control system
Issued 16 April 2026
Resolved
On U.S. inspected ships, oily water separating equipment and bilge alarms must be approved under 46 CFR 162.050. Content meter for the Oily Water Separator digital display lights are not functioning as designed. Replace or repair content meter unit.
33 CFR 155.380
Action required: 50 - Rectify deficiencies w/in 30 days
Due 16 May 2026
Resolved 17 April 2026
Resolution: Vessel emailed objective evidence of new OWS screen being installed.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 5 March 2026
Resolved
After any survey of the ship under regulations 7,8,9, or 10 of this chapter has been completed, no change shall be made in the structural arrangements, machinery, equipment, etc. covered by the survey, without the sanction of the administration. Vessel reported a loss o propulsion due to the fuel rack linkage. Provide the root cause of failure, make necessary repairs and provide report from classification society. Upon U.S. Coast Guard receipt of the class report confirming the main propulsion engine problem has been rectified and the engine is fully operational, the vessel may depart Honolulu Port. Vessel is required tug assist of sufficient horsepower and bollard pull rating when transiting in and out of the harbor.
74 SOLAS I/11
Action required: 60 - Rectify deficiencies prior to movement
Resolved 6 March 2026
Resolution: ABS Report: The turning gear safety interlock was tested in the engaged and disengaged positions with all found satisfactory.
07 - Fire Safety › N/A - No Subsystem › Fire prevention structural integrity
Issued 12 July 2024
Resolved
Where A class divisions are pierced for the passage of electrical cables... shall be made to ensure the fre resistance is not impaired. Multi cable transit under the bridge console found missing sections of fre stop.
74 SOLAS II-2/23(a)
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 15 July 2024
Resolution: Accepted by RO as Finding No. 2537.0
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 12 July 2024
Resolved
The current carrying capacity of each circuit shall be permanently indicated, together with the rating or setting of the appropriate overload protective device. Multiple distribution panels throughout vessel found with inaccurate circuit directories.
74 SOLAS II-1/27(a)(vii)
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 15 July 2024
Resolution: Accepted by RO as Finding No. 2539.0
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 12 July 2024
Resolved
Wiring shall be supported in such a manner as to avoid chafng or other injury. Shore power cable glands found incorrectly installed on the starboard shore power box.
74 SOLAS II-1/27(a)(vi)
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 15 July 2024
Resolution: Accepted by RO as Finding No. 2540.0
07 - Fire Safety › N/A - No Subsystem › Fire prevention structural integrity
Issued 12 July 2024
Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure that the ship in all respects will remain ft to proceed to sea without danger to the ship or persons on board. Exhaust lagging on turbocharger outlet for
SSDG No. 2 found improperly installed.
74 SOLAS (20) I/11(a)
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 15 July 2024
Resolution: Accepted by RO as Finding No. 2541.0
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Maintenance of the ship and equipment
Issued 12 July 2024
Resolved
Every company should develop, implement, and maintain a safety management system which includes the following functional requirements: instructions and procedures to ensure safe operation of ships and protection of the environment in compliance with relevant international and
fag state legislation. Various Lock Out/Tag Out tags were found affxed to various electrical installations in the ship’s service spaces. LOTO tag numbers were not utilized, and were not logged in the Lock Out/Tag Out Log Book as required per the Ship’s SMS (C-01-170, Rev. 7, Lockout-Tagout Safety Procedures). Company shall conduct an internal audit focused on the lockout-tagout procedures.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 12 October 2024
Resolved 17 October 2024
Resolution: Received internal audit report which was found satisfactory.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 25 June 2024
Resolved
Steering failure on primary steering control resulting in rudder being stuck Port 10 degree. Vessel has back up steering which is operating as designed.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 29 June 2024
Resolved 29 June 2024
Resolution: A failed relay was discovered in the steering system. A tech replaced the faulty relay and ABS attended to verify repairs. ABS report is attatched in documents.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 20 June 2024
Resolved
(a) No repairs or alterations affecting the safety of the vessel with regard to the hull, machinery, or equipment, shall be made without the knowledge of the Officer in Charge, Marine Inspection. Vessel's #2 Ships Service Generator shut down due to high frequency resulting in a loss of power and loss of propulsion.
Condition: Damaged By Earlier Event
Action required: 17 - Rectify deficiencies prior to departure
Due 20 June 2024
Resolved 23 June 2024
Resolution: Recieved class report from ABS to clear deficiencies.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 20 June 2024
Resolved
(a) Vital systems that are automatically or remotely controlled must be provided with—
(1) An effective primary control system;
(2) A manual alternate control system;
(3) A safety control system, if required by § 62.25-15;
(b) Automation systems or sub systems that control or monitor more than one safety control, interlock, or operating sequence must perform all assigned tasks continuously, i.e., the detection of unsafe conditions must not prevent control or monitoring of other conditions. Vessel's main bus that supplies power to the emergency switchboard will not close.
Condition: Damaged By Earlier Event
Action required: 17 - Rectify deficiencies prior to departure
Due 20 June 2024
Resolved 23 June 2024
Resolution: Received class report from ABS clearing deficiencies.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Scuppers, inlets and discharges
Issued 21 February 2024
Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or persons on board. Vessels chloropac discharge line at the stbd sea chest found with a leaking flange outboard of the sea valve. Vessel shall complete a temporary or permanent repair.74 SOLAS (20) I/11
Action required: 15 - Rectify deficiencies by next port
Resolved 23 February 2024
Resolution: Temporary repair completed 23FEB24 to the satisfaction of ABS.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 21 February 2024
Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or persons on board. OWS return line hose is failing and needs to be replaced.74 SOLAS (20) I/11
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 22 February 2024
Resolution: Accepted By RO for rectification oversight.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 21 February 2024
Resolved
Maintenance, testing and inspections shall be carried out based on the guidelines developed by the Organization* and in a manner having due regard to ensuring the reliability of fire-fighting systems and appliances. Vessels CO2 system found with 04 hoses in poor condition.
74 SOLAS(20) II-2/14.2.2.1
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 22 February 2024
Resolution: Accepted By RO for rectification oversight.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 21 February 2024
Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or persons on board. A soft patch was found on the main engine air cooler cleaning return line. Repair to original condition. 74 SOLAS (20) I/11
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 22 February 2024
Resolution: Accepted By RO for rectification oversight.
01 - Certificates & Documentation › 012 - Crew Certificates › Certificates for master and officers
Issued 21 February 2024
Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 4 March 2024
Resolution: Mariner received notice of correction made to MMC by NMC.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 21 February 2024
Resolved
Every oil fuel suctions pipe from a storage, settling, or daily service tank situated above the double bottom shall be fitted with a cock or valve capable of being closed from outside the space. EDG F/O day tank shutoff found inoperable.
74 SOLAS II-2/50c
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 21 February 2024
Resolution: Reach rod for the F/O shutoff was repaired and tested satisfactorially.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 4 October 2023
Resolved
1- The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or persons on board. Vessels main engine automatic actuator valve seized causing all the starter air to drain out of the system. Vessel must repair the system to the satisfaction of class and the marine inspector. 74SOLAS(20) I/II(a)
Condition: Invalid
Action required: 60 - Rectify deficiencies prior to movement
Resolved 6 October 2023
Resolution: Vessel completed temporary repairs for voyage to LA/LB. Vessel Engineer reached out to the office and stated permanent repairs have been completed.
11 - Life Saving Appliances › N/A - No Subsystem › Launching arrangements for survival craft
Issued 17 August 2023
Resolved
Operational readiness: Before the ship leaves port and at all times during the voyage, all life-saving appliances shall be in working order and ready for immediate use. The bowsing slip-hook attachment on both port and starboard lifeboats are seized and do not operate as required.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 17 August 2023
Resolution: Vessel's crew worked throughout the inspection to loosen the seized bowsing hooks and proved proper operation prior to the end of the inspection. Deficiency cleared.
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 17 August 2023
Resolved
Training manual: a training manual shall be provided and shall explain; operation and use of fire-fighting systems and appliances. Training manual does not explain operation of the two SCBA fire-fighting appliances used onboard.
Condition: Placed in Improper Service
Action required: 50 - Rectify deficiencies w/in 30 days
Due 17 September 2023
Resolved 16 September 2023
Resolution: Vessel provided updated training manual with instructions for using the two SCBA appliances onboard, all satisfactory.
07 - Fire Safety › N/A - No Subsystem › Fire control plan
Issued 17 August 2023
Resolved
General arrangement plans (fire control plan) shall be permanently exhibited...clearly showing fire sections; fire alarm systems; fire extinguishing appliances. Fire control plan (FCP) is missing the proper labeling for the installed CO2 piping, CO2 discharge alarm, and CO2 protected space. FCP does not properly identify CO2 protected spaces. Bosun stores noted as not having CO2 system installed, but has CO2 protecting space.
Condition: Placed in Improper Service
Action required: 50 - Rectify deficiencies w/in 30 days
Due 17 September 2023
Resolved 20 November 2023
Resolution: RCVD email from Matson with ABS Approval attached.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 17 August 2023
Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions to ensure the ship will remain fit to proceed to sea without danger to the ship and persons onboard. Emergency bilge suction valve must be labeled in the engine room.
Condition: Improper Installation
Action required: 10 - Deficiency Rectified
Resolved 17 August 2023
Resolution: Vessel provided proper labeling prior to the end of the inspection.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 17 August 2023
Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions to ensure the ship will remain fit to proceed to sea without danger to the ship and persons onboard. Fire fighting applicator wands do not fit with 2.5 inch nozzle. Replace with 1.5 inch nozzle to comply.
Condition: Placed in Improper Service
Action required: 10 - Deficiency Rectified
Resolved 17 August 2023
Resolution: Vessel provided proper nozzle.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 10 April 2023
Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Action required: 60 - Rectify deficiencies prior to movement
Resolved 14 April 2023
Resolution: bad cable connection in the electric power supply to the electromagnetic
converter which relays the pneumatic signal to the main engine governor failed. This defective cable connection was replaced, and thestarting system restored to order by the OEM rep
07 - Fire Safety › N/A - No Subsystem › Remote Means of control (opening,pumps,ventilation,etc.) Machinery spaces
Issued 7 April 2023
Resolved
Requires the fullest practicable degree of fire protection, detection and extinction: specifically containment and extinction of any fire in the space of origin. Port engine room fire dampner was found not to be closing fully.
74 SOLAS II-2/2(e)
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 8 April 2023
Resolution: RO witnessed proper operation of fire dampner.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 7 April 2023
Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or persons. MDO purifier relief valve found leaking in purifier space.
74 SOLAS (20) I/11(a)
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 8 April 2023
Resolution: RO witnessed rectification of fue leak.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Insulation wetted through (oil)
Issued 7 April 2023
Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or persons. Lagging in the purifier space was found to be soaked with fuel oil. Replace lagging to satisfaction of RO
74 SOLAS (20)I/11(a)
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 22 April 2023
08 - Alarms › N/A - No Subsystem › Machinery controls alarm
Issued 7 April 2023
Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or persons. Visual alarm indicator(s) were observed not to be working in the lower level of the engine room.
74 SOLAS (20) I/11(a)
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 22 April 2023
07 - Fire Safety › N/A - No Subsystem › Fire-dampers
Issued 7 April 2023
Resolved
Requires the fullest practicable degree of fire protection, detection and extinction: specifically containment and extinction of any fire in the space of origin. Two ventilation dampners in vicinity of exhaust sytem 2-103-2 found not to be operational.
74 SOLAS II-2/2(e)
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 22 April 2023
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 7 April 2023
Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or persons. Differential oil filter housing observed leaking oil on #3 SSDG.
74 SOLAS (20) I/11(a)
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 22 April 2023
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 7 April 2023
Resolved
Requires the fullest practicable degree of fire protection, detection and extinction: specifically ready availability of fire extinguishing appliances. Two hoses in fixed high pressure CO2 system observed to be cracking.
74 SOLAS II-2/2(g)
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 22 April 2023
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 7 April 2023
Resolved
Requires the fullest practicable degree of fire protection, detection and extinction: specifically restricted use of combustible materials. Fiberglass grating in engine room observed to be covered in oil and no approval data plate was visible to confirm type/rating approval. Clean grating to remove oil and confirm rating approval to satisfaction of RO.
74 SOLAS II-2/2(c)
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 22 April 2023
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › UMS - Ship
Issued 7 April 2023
Resolved
In every inspection/survey of the ship, the Administration shall fully guarantee the completeness and efficiency of the inspection and survey, and shall undertake to ensure the necessary arrangements to satisfy this obligation. Approved PSTPs were not available during inspection, provide approved Periodic Safety Test Procedures as well as records indicating when lasts tests occurred. Additionally, provide historic documentation of any automation equipment changes/updates completed to the vessel and associated plan approval for such changes/updates to include updating to Konsberg alarm system.
74 SOLAS (20) I/6
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 22 April 2023
Resolution: Recieved approved automation PSTPs and documentation of completion of most recent tests.
01 - Certificates & Documentation › 011 - Ships Certificates › Safety Management Certificate (SMC/ ISM)
Issued 3 August 2022
Resolved
Every company should develop, implement and maintain a safety management system which includes the following functional requirements: instructions and procedures to ensure safe operation of ships and protection of the environment in compliance with relevant international and flag state legislation. Vessel shall conduct internal audit focusing on procedures for Oil Record Book entries, proper procedures for documenting/repairing inoperable equipment, and lock out/tag out procedures. Audit and corrective action shall be completed within three months.
74 SOLAS (20) IX/3
ISM Code Part A/1.4
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 3 November 2022
Resolved 16 November 2022
Resolution: Matson conducted and provided copy of internal ISM audit dated 2NOV22.
01 - Certificates & Documentation › 013 - Documents › Oil record book
Issued 3 August 2022
Resolved
Every ship of 400 gross tonnage and above shall be provided with an Oil Record Book Part I. The Oil Record Book shall be in the form specified in appendix III to this Annex. MI found that Oil Record Book consisted of inaccurate entries and inconsistent measurements.
MARPOL I/17.1
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 17 August 2022
Resolved 12 August 2022
Resolution: Amendments to the ORB were made to the satisfaction of the attending Marine Inspector.
07 - Fire Safety › N/A - No Subsystem › Ready availability of fire fighting equipment
Issued 3 August 2022
Resolved
Personal equipment shall consist of the following: electric safety lamp (hand lantern) of an approved type. During fire drill, MI found that some of the
firefighters did not have flashlights.
74 SOLAS(20) II-2/10.1.1
FSS Code 3.2.1.1.5
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 17 August 2022
Resolved 11 August 2022
Resolution: Corrected to the satisfaction of the attending ABS Surveyor.
07 - Fire Safety › N/A - No Subsystem › Ready availability of fire fighting equipment
Issued 3 August 2022
Resolved
Personal equipment shall consist of the following: axe with handle provided with high voltage insulation. During fire drill, none of the firefighters were equipped with axes.
74 SOLAS(20) II-2/
10.1.1
FSS Code 3.2.1.1.5
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 17 August 2022
Resolved 11 August 2022
Resolution: Corrected to the satisfaction of the attending surveyor.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 3 August 2022
Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or persons onboard. Several fire stations were found with disconnected fire hoses and/or disconnected nozzles.
74 SOLAS (20) 1/11(a)
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 17 August 2022
Resolved 11 August 2022
Resolution: Corrected to the satisfaction of the attending ABS Surveyor.
02 - Structural Conditions › N/A - No Subsystem › Closing devices/watertight doors
Issued 3 August 2022
Resolved
In all classes of watertight doors indicators shall be fitted which show, at all operating stations from which the doors are not visible, whether the doors are open or closed. WTD position indicator switch in shaft alley was found disconnected and no signage to keep closed while underway was present.
74 SOLAS (74) II-I/13(f)(V)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 17 August 2022
Resolved 11 August 2022
Resolution: Corrected to the satisfaction of the attending ABS Surveyor.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 3 August 2022
Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or persons onboard. All safety signage regarding CO2 safety at EDG was found to be painted over.
74 SOLAS (20) 1/11(a)
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 17 August 2022
Resolved 11 August 2022
Resolution: Corrected to the satisfaction of the attending ABS Surveyor.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 3 August 2022
Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or persons onboard. MDE Cylinder 12 fwd scavenge air found off scanned due to malfunction without follow up for repair action.
74 SOLAS (20) 1/11(a)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 17 August 2022
Resolved 12 August 2022
Resolution: Corrected to the satisfaction of the attending ABS Surveyor.
14 - Pollution Prevention › 141 - MARPOL Annex I › Pumping, piping and discharge arrangements
Issued 3 August 2022
Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or persons onboard. The F/O vent starboard aft of house by CT 1 on main deck was found to have a soft patch. No knowledge or records of repairs were made available. Additionally, a soft patch was found on discharge side of aft bilge well wilden pump.
74 SOLAS (20) 1/11(a)
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 3 September 2022
Resolved 11 August 2022
07 - Fire Safety › N/A - No Subsystem › International shore-connection
Issued 3 August 2022
Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or persons onboard. International Shore Connection on port side was not found in the location listed in the Fire Control Plan.
74 SOLAS (20) 1/11(a)
Condition: Improper Installation
Action required: 10 - Deficiency Rectified
Resolved 3 August 2022
Resolution: Crew found ISC and placed it where it belongs IAW FCP.
09 - Working and Living Conditions › 091 - Living Conditions › Electrical devices
Issued 3 August 2022
Resolved
Emergency switchboards shall be so arranged as to give easy access back and front, without danger to attendants. MI found items stored behind emergency bus switchboard.
74 SOLAS (74) I/27(a)(ii)
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 3 August 2022
Resolution: Crew removed items and ensured area clear.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 3 August 2022
Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or persons onboard. MI discovered #1 start air compressor was tagged out for maintenance, but was being used operationally.
74 SOLAS (20) 1/11(a)
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 3 August 2022
Resolution: Crew corrected inaccurate entries in the lockout/tagout record.
09 - Working and Living Conditions › 092 - Working Conditions › Lighting (Working spaces)
Issued 3 August 2022
Resolved
Lighting fittings shall be arranged to prevent temperature rises that would be injurious to the wiring, and to prevent surrounding material from becoming excessively hot. Exterior lighting fixture on main deck at CT 4P was found to have a fractured wiring housing.
74 SOLAS (74) II-1/27(a)(v)
Condition: Damaged By Earlier Event
Action required: 10 - Deficiency Rectified
Resolved 3 August 2022
Resolution: Repaired in kind with parts available on ship at time of inspection.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 29 September 2019
Resolved
Fuel oil piping system on main engine fractured and leaking. Properly repair system to the satisfaction of the attending marine inspector.
Condition: Damaged By Earlier Event
Action required: 17 - Rectify deficiencies prior to departure
Due 29 September 2019
Resolved 29 September 2019
Resolution: Fractured piping segment replaced.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 10 June 2019
Resolved
After any survey of the ship under Regulations 7, 8, 9 or 10 of this Chapter has been completed, no change shall be made in the structural arrangements, machinery, equipment, etc. covered by the survey, without the sanction of the Administration. The after centerline winch brake pad was found with an approximately 14" section ripped out.
Condition: Damaged By Earlier Event
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 June 2019
Resolved 19 June 2019
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 10 June 2019
Resolved
After any survey of the ship under Regulations 7, 8, 9 or 10 of this Chapter has been completed, no change shall be made in the structural arrangements, machinery, equipment, etc. covered by the survey, without the sanction of the Administration. The forward mooring winch brake found in a skewed position, preventing it from making full friction contact.
Condition: Damaged By Earlier Event
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 June 2019
Resolved 19 June 2019
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 10 June 2019
Resolved
After any survey of the ship under Regulations 7, 8, 9 or 10 of this Chapter has been completed, no change shall be made in the structural arrangements, machinery, equipment, etc. covered by the survey, without the sanction of the Administration. Starboard sludge connection found with a leak at the base of the cap. No overboard discharge detected.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 June 2019
Resolved 19 June 2019
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 10 June 2019
Resolved
All inlets and discharges in the shell plating shall be fitted with efficient and accessible arrangements for preventing the accidental admission of water into the ship. The sea suction chloro-treatment overboard pipe in the forward starboard lower level E/R is leaking at the elbow and likely also at the valve.
74 SOLAS II-1/14(i)(i)
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 10 July 2019
Resolved 19 June 2019
11 - Life Saving Appliances › N/A - No Subsystem › Inflatable liferafts
Issued 10 June 2019
Resolved
Liferafts shall be stowed as to float free in the event of the ship sinking. All 04 inflatable liferafts were found improperly installed, with the painter line not attached to the weak link, thus preventing the liferafts from floating free.
74 SOLAS III/16(m)
Condition: Improper Installation
Action required: 10 - Deficiency Rectified
Due 10 June 2019
Resolved 10 June 2019
Resolution: Crew reattached painter line to proper position.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 10 June 2019
Resolved
After any survey of the ship under Regulations 7, 8, 9 or 10 of this Chapter has been completed, no change shall be made in the structural arrangements, machinery, equipment, etc. covered by the survey, without the sanction of the Administration. The Bosun Store was found with paint stores inside, while not having the required electrical equipment and fire fighting systems.
Condition: Placed in Improper Service
Action required: 10 - Deficiency Rectified
Due 10 June 2019
Resolved 10 June 2019
Resolution: Crew removed paint from the space.
07 - Fire Safety › N/A - No Subsystem › International shore-connection
Issued 10 June 2019
Resolved
The international shore connexion required in this Chapter shall be kept aboard the ship together with a gasket of any suitable material for 10.5 kilogrammes per square centimeter (150 pounds per square inch) service, together with four 15 millimetre (5/8 inch) bolts, 50 millimetres (2 inches) in length and eight washers. The port side international shore connection is missing the gasket and the starboard side connection is missing a bolt and two washers.
74 SOLAS II-2/5(h)
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 10 June 2019
Resolved 10 June 2019
Resolution: Crew found the required components from a spare connection not listed on the fire control plan.
09 - Working and Living Conditions › 092 - Working Conditions › Lighting (Working spaces)
Issued 10 June 2019
Resolved
After any survey of the ship under Regulations 7, 8, 9 or 10 of this Chapter has been completed, no change shall be made in the structural arrangements, machinery, equipment, etc. covered by the survey, without the sanction of the Administration. Aft deck light found cracked and filled with water.
Condition: Damaged By Earlier Event
Action required: 10 - Deficiency Rectified
Due 10 June 2019
Resolved 10 June 2019
Resolution: Crew replaced light.
09 - Working and Living Conditions › 092 - Working Conditions › Lighting (Working spaces)
Issued 10 June 2019
Resolved
After any survey of the ship under Regulations 7, 8, 9 or 10 of this Chapter has been completed, no change shall be made in the structural arrangements, machinery, equipment, etc. covered by the survey, without the sanction of the
Administration. Starboard transfer station light is inoperable.
Condition: Damaged By Earlier Event
Action required: 50 - Rectify deficiencies w/in 30 days
Due 10 July 2019
Resolved 19 June 2019
07 - Fire Safety › N/A - No Subsystem › Fire prevention structural integrity
Issued 5 June 2019
Resolved
The hull, superstructure, structural bulkheads, decks and deckhouses shall be constructed of steel, except where the Administration may sanction the use of other suitable material in special cases, having in mind the risk of fire. The fiberglass decking adjacent to main control which provides air flow for the compressors is not fire rated and therefore could present a risk to crew members in the event of an engine room fire.
74 SOLAS II-2/51(a)
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 10 July 2019
Resolved 19 June 2019
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Shipboard operations
Issued 5 June 2019
Resolved
Every company should develop, implement and maintain a safety management system which includes the following functional requirement: instructions and procedures to ensure safe operation of ships and protection of the environment in compliance with relevant international and flag State legislation. Per ship's SMS, danger tags shall list the installer's name and be signed by all newly reporting crew members. Ship's crew was not following tag out procedures as noted by a lack of information on currently installed danger tags.
74 SOLAS (14) IX/3.1
ISM Code A/1.4.2
Action required: 10 - Deficiency Rectified
Due 10 June 2019
Resolved 10 June 2019
07 - Fire Safety › N/A - No Subsystem › International shore-connection
Issued 1 November 2018
Resolved
The three engine room international shore connections were found not slotted.
Condition: Design Flaw
Action required: 10 - Deficiency Rectified
Resolved 20 November 2018
Resolution: All three were slotted per the SOLAS FSS code and re-installed in the correct location.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 1 November 2018
Resolved
EDG fuel shut off valve is functional but need to be tightened and maintained. Hand wheel was loose.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 1 November 2018
Resolution: The hand wheel was tightened up and considered satisfactory.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Manholes/flush scuttles
Issued 1 November 2018
Resolved
Emergency Escape hatch located starboard side from the 2nd deck to the 3rd deck was found with not all 4 dogs making contact.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 1 November 2018
Resolution: The ship's crew adjusted the dogs and demonstrated proper operation was verified.
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 1 November 2018
Resolved
Aft Aux Electric Equipment RM located port side Aft House Upper Deck was found with a hold back. The door to the space was marked with as CO2 protected space and siren and deliver nozzle were noted.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 1 November 2018
Resolution: Space was CO2 protected. Ship crew to remove holdback and make door operational. Fire control plans to be updated to reflect CO2 protected. To be verified 02 NOV 2018 by ABS
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 1 November 2018
Resolved
Carpenters Shop starboard side 81'-8" Flat. The door was marked as CO2 protected space and a siren and delivery nozzle were visible. The door was missing the latch and was tied open.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 2 November 2018
Resolution: Space was CO2 protected. Ship crew to renew the lock and make door operational. Fire control plans to be updated to reflect CO2 protected.
07 - Fire Safety › N/A - No Subsystem › Fire-dampers
Issued 1 November 2018
Resolved
Vent shut off for damper no. 100 located in the Aft Aux Electric Equipment RM located port side Aft House Upper Deck was found with remote reach rod disconnected.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 2 November 2018
Resolution: The reach rod is re-welded and demonstrated proper operation.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Doors
Issued 1 November 2018
Resolved
Aft house door starboard side at 81'-8" level was found with the upper latch loose and needing adjustment.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 2 November 2018
Resolution: Door repaired and properly closes.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 1 November 2018
Resolved
120v REFRIG, UPPER DECK & FOSCLE DK POWER panel no. FDR 1FP-105 was found missing lower latch key tumbler and with breaker no. 16 tagged out due to possible ground.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 1 November 2018
Resolution: The latch key tumbler was replaced as original and the breaker was properly tagged out. There was no active ground but the equipment is tagged out for maintenance.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 1 November 2018
Resolved
#1 chiller expansion joint found cracking. Ships crew created a job in the PM system to renew the expansion joint. The fresh waster cooling to the chiller is non critical system.
Action required: 705 - Other - as specified
Resolved 20 November 2018
09 - Working and Living Conditions › 092 - Working Conditions › Winches & capstans
Issued 1 November 2018
Resolved
Crane hydraulic oil tank found leaking. Located port side deck machinery room.
Action required: 10 - Deficiency Rectified
Resolved 1 November 2018
Resolution: The space was cleaned up. The chief engineer report root cause of the oil on deck was improper house cleaning while topping off the tank. System was operated with no active leaks apparent.
09 - Working and Living Conditions › 091 - Living Conditions › Lighting (Accommodation)
Issued 1 November 2018
Resolved
Florescent lights found missing covers. Located on the old pool deck.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 1 November 2018
Resolution: The ship chief engineer identified and replaced the missing covers in the space.
07 - Fire Safety › N/A - No Subsystem › Fire control plan
Issued 1 November 2018
Resolved
Fire Control plan were blurry. The fire control booklet on the bridge was accessible and easy to read.
Condition: Design Flaw
Action required: 705 - Other - as specified
Resolved 20 November 2018
Fire Fighting › Fixed CO2 Fire Extinguishing System › Nozzle
Issued 23 May 2018
Resolved
Fire-fighting systems shall be kept in good working order. CO2 dispersant head found caked in HFO behind the main engine fuel oil booster pumps. Vessel shall clear the head of all oils or renew as original.74SOLAS(14)Ch.II-2 14.2.1.2
Action required: 16 - Rectify deficiencies w/in 14 days
Due 6 June 2018
Resolved 1 June 2018
Resolution: CO2 nozzle cleaned to the satisfaction of ABS. Report 1812 HL3506099-D
Fire Fighting › Structural - A Class Divisions › Machinery Spaces
Issued 23 May 2018
Resolved
Structural fire protection shall be kept in good order to ensure their required performance. Doors leading from the engine room to the purifier room were found ill fitting to their frames and allowing the passage of light/vapors between spaces. Required A-0 boundary shall be reinstated. 74SOLAS(14)Ch.II-2 14.2.1.2 and 74SOLASCh.II-2 Reg. 20 Table 1
Action required: 16 - Rectify deficiencies w/in 14 days
Due 6 June 2018
Resolved 7 July 2018
Resolution: Vessel corrected one of 2 doors to the satisfaction, ABS granted 30 day extension for the second door repair. Report 1869 LA3508168-C. Item resolved in ABS Report LA3523342
Operations/Management › Bilge/Bilge System Management › Control of Oil Mixtures
Issued 23 May 2018
Resolved
Vessel shall not maintain excess oils and debris in the bilges. Excess turbine oils found under the SSTG in and around heated oil piping. Vessel shall ensure all excess oils are removed.
Action required: 10 - Deficiency Rectified
Due 23 May 2018
Resolved 23 May 2018
Resolution: Crew cleaned all spills/debris during inspection. Re-inspected area.
Stability › Watertight Integrity › General
Issued 23 May 2018
Resolved
Watertight escape hatch from the ECR found out of adjustment and unable to seal. Adjust hatch to ensure it is watertight.
Action required: 15 - Rectify deficiencies by next port
Due 31 May 2018
Resolved 1 June 2018
Resolution: Double gasket installed preventing proper operation/sealing. Corrected to the satisfaction of ABS. Report 1814 HL3506099-D
Engineering › Steering Gear System › Valve
Issued 23 May 2018
Resolved
Emergency steering instructions include the labeling of valves to be used, identified valve "F" missing label on the stbd steering gear installation. Provide label.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 23 June 2018
Resolved 1 June 2018
Resolution: Missing label was provided to the satisfaction of ABS. Report 1815 HL3506099-D
Engineering › Steering Gear System › Rudder Angle Indicator
Issued 23 May 2018
Resolved
Engineering flat rudder angle indicator linkage found unbolted and near failure. Renew missing bolts in linkage.
Action required: 10 - Deficiency Rectified
Due 23 May 2018
Resolved 23 May 2018
Resolution: Crew reattached linkage and tightened.
Communications › Alarms/Indicators › Fire Alarm
Issued 23 May 2018
Resolved
Fire control panel in the port tunnel was found with 5 inoperable indicator lights. Repair inoperable lights.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 23 June 2018
Resolved 1 June 2018
Resolution: Lights were replaced and proper operation witnessed by ABS. Report 1816 HL3506099-D
Engineering › Diesel Engine (propulsion-reduction gear) › Cylinder Liner
Issued 23 May 2018
Resolved
The #6 cylinder jacket water temperature probe was found lose from its housing and was identified as too large to be properly secured. Provide correct size temperature probe and secure as instructed by manufacturer.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 23 June 2018
Resolved 1 June 2018
Resolution: Correct temperature probe installed to the satisfaction of ABS. Repost 1817 HL3506099-A
Engineering › Diesel Engine (propulsion-reduction gear) › Exhaust Manifold
Issued 23 May 2018
Resolved
Cylinder 1 and 2 were identified as missing exhaust temperature gauges. Gauges were subsequently found on the engine behind the cylinders having broken free from its mountings. Re-install gagues in a visible area for watch standers.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 23 June 2018
Resolved 1 June 2018
Resolution: Gauges were re-installed to the satisfaction of ABS. Report 1818 HL3506099-A
Engineering › Steam Boiler (auxiliary/waste heat) › Gauge Glass
Issued 23 May 2018
Resolved
Auxiliary boiler found with inboard leaking water level glass gauge. Repair gauge.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 23 June 2018
Resolved 1 June 2018
Resolution: Leaking gauge replaced in kind to the satisfaction of ABS. Report 1819 HL3506099-A
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Location
Issued 23 May 2018
Resolved
During round of the engine room, fire extinguisher #49 was found off station. Replace extinguisher to it's assigned location.
Action required: 15 - Rectify deficiencies by next port
Due 31 May 2018
Resolved 1 June 2018
Resolution: Extinguisher replaced to proper station to the satisfaction of ABS. Report 1820 HL3506099-D
Engineering › Fuel Oil Service System › Heater
Issued 23 May 2018
Resolved
Two steam valves in the steam heating inlet line to the fuel heater were found leaking. Repair/repack valves to ensure they will not cause personnel injury.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 23 June 2018
Resolved 1 June 2018
Resolution: Valves were repaired to the satisfaction of class. Report 1821 HL3506099-A
Fire Fighting › Combustible Materials › Stowage
Issued 23 May 2018
Resolved
Jugs of boiler chemicals and kerosene were found improperly stored behind the MCCC motor controller panel in the engine room. Kerosene shall be stored in a paint locker and the chemicals are to be properly secured in their shelves.
Action required: 10 - Deficiency Rectified
Due 23 May 2018
Resolved 1 June 2018
Resolution: Chemicals were moved to proper storage location to the satisfaction of ABS. Report 1822 HL3506099-D
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 23 May 2018
Resolved
SSDG number 1 found with section of exhaust lagging soaked with oil. Renew lagging to minimize fire hazard.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 23 June 2018
Resolved 1 June 2018
Resolution: Lagging was cleaned to the satisfaction of ABS. Report 1823 HL3506099-D
Accommodation/Occupational Safety › Occupational Safety › Tripping/Falling Hazard
Issued 23 May 2018
Resolved
Ladder from the engine room to shaft alley found lose and unbolted from its upper foundations. Secure ladder.
Condition: Improper Installation
Action required: 15 - Rectify deficiencies by next port
Due 31 May 2018
Resolved 1 June 2018
Resolution: Ladder was secured to the satisfaction of ABS. Report 1824 HL3506099-A
Documentation › Markings/Placards › Warning Signs
Issued 23 May 2018
Resolved
Door to aft steering flat found with CO2 Warning sign painted over and illegible. Remove paint from sign or provide legible warning.
Action required: 15 - Rectify deficiencies by next port
Due 31 May 2018
Resolved 1 June 2018
Resolution: Paint removed from warning signage to the satisfation of ABS. Report 1825 HL3506099-D
Engineering › Fuel Oil Service System › Flange
Issued 17 January 2018
Resolved
A survey, either general or partial, shall be made every time a defect is discovered which affects the safety of the vessel or whenever any important repairs are made. Vessel personnel noticed a slight leak on the main engine fuel line at an expansion joint.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 18 January 2018
Resolved 19 January 2018
Resolution: See ABS Report SF3440364 17JAN18.
Engineering › Fuel Oil Service System › Flange
Issued 17 January 2018
Resolved
When repair of machinery or piping systems becomes necessary, the work shall be done in accordance with the regulations in effect at the time of build or modification.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 18 January 2018
Resolved 19 January 2018
Resolution: See ABS Report SF3440364 17JAN18.
Engineering › Generator (propulsion/auxiliary-electric) › Generator Excitation Circuitry
Issued 21 November 2017
Resolved
Prove proper operation of emergency diesel generator auto start. SOLAS(09)II-2/43.3.3
Condition: Invalid
Action required: 17 - Rectify deficiencies prior to departure
Resolved 22 November 2017
Resolution: Witnessed proper operation of emergency generator under load.
Fire Fighting › Fixed CO2 Fire Extinguishing System › Piping
Issued 21 November 2017
Resolved
Replace ECR entrance CO2 bottle dry rotted hose. SOLAS(09)II-2/14.2.1.2
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 22 January 2018
Resolved 3 January 2018
Resolution: Replacement verified by class surveyor. Report attached to this activity.
Fire Fighting › Fixed Gas Fire Extinguishing System › Piping
Issued 21 November 2017
Resolved
Replace ECR entrance CO2 bottle dry rotted reel hose. SOLAS(09)II-2/14.2.1.2
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 22 January 2018
Resolved 3 January 2018
Resolution: Replacement verified by class surveyor. Class report attached to this activity.
Lifesaving › Lifejacket/PFD (Type II) › Lights
Issued 21 November 2017
Resolved
Replace ECR PFD expired lights. SOLAS(09)III/32.2
Condition: Invalid
Action required: 17 - Rectify deficiencies prior to departure
Resolved 24 November 2017
Resolution: Lights were replaced on PFD.
Fire Fighting › Structural - A Class Divisions › Doors
Issued 21 November 2017
Resolved
Prove proper operation/closure of the ECR class A-60 door. SOLAS(09)II-2/9.4.1.12
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 24 November 2017
Resolution: Witnessed proper operation/closure of door.
Engineering › Steam Boiler (auxiliary/waste heat) › Valve, Drum Safety
Issued 21 November 2017
Resolved
Test 02 boiler safety valves in place and prove proper blow down settings of 2-4%. ABS 4-4-1/1.
Condition: Invalid
Action required: 705 - Other - as specified
Due 22 December 2017
Resolved 8 December 2017
Resolution: Valve test observed by class surveyor. All sat. Copy of survey report attached to this activity.
Engineering › Pressure Vessel › Relief Valve
Issued 21 November 2017
Resolved
Replace SSDG start air receiver relief valve. ABS 4-4-1/1
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 22 December 2017
Resolved 24 November 2017
Resolution: Replaced relief valve.
Engineering › Pressure Vessel › Relief Valve
Issued 21 November 2017
Resolved
Replace STBD main engine start air receiver relief valve. ABS 4-4-1/1
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 22 December 2017
Resolved 24 November 2017
Resolution: Replaced safety relief valve.
Engineering › Steam System (auxiliary) › Valve, Control
Issued 21 November 2017
Resolved
Replace steam reducing station regulator valve. ABS 4-6-6/3.13
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 22 December 2017
Resolved 24 November 2017
Resolution: Replaced reducing station regulator gauge.
Engineering › Steam System (auxiliary) › Valve
Issued 21 November 2017
Resolved
Calibrate steam reducing station gauge. ABS 4-6-6/3.13
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 22 December 2017
Resolved 8 December 2017
Resolution: Class surveyor verified replacement with a calibrated gauge. A copy of the class survey is attached to this activity.
Fire Fighting › Fixed Fire Detection System › Smoke Detectors
Issued 21 November 2017
Resolved
Remove bags over high voltage refrigeration space smoke detectors. SOLAS(09)II-2/53
Condition: Invalid
Action required: 17 - Rectify deficiencies prior to departure
Resolved 24 November 2017
Resolution: Crew removed bags over smoke detectors and conducted satifactory test of smoke alarms.
Pollution Prevention/Response › Prevention Equipment › Oily Water Separator (15 ppm)
Issued 21 November 2017
Resolved
Prove proper operation of OWS oil content meter and three way valve. ABS SUP 33CFR155.380
Condition: Invalid
Action required: 17 - Rectify deficiencies prior to departure
Resolved 24 November 2017
Resolution: Witnessed operation of OWS system.
Electrical › Electrical Distribution System (service) › Distribution Panel Bus
Issued 21 November 2017
Resolved
Provide door latches on all receptacle panels. SOLAS(09)II-1/45.1
Condition: Invalid
Action required: 705 - Other - as specified
Due 22 December 2017
Resolved 22 December 2017
Resolution: Class surveyor verified that door latches and blanks were replaced. A copy of the class report is attached to this activity.
Electrical › Electrical Distribution System (service) › Distribution Panel Bus
Issued 21 November 2017
Resolved
Provide blanks for all receptacle panel breaker openings. SOLAS(09)II-1/45.1
Condition: Invalid
Action required: 705 - Other - as specified
Due 22 December 2017
Resolved 22 December 2017
Resolution: Class surveyor verified that door latches and blanks were replaced. A copy of the class report is attached to this activity.
Fire Fighting › Fixed CO2 Fire Extinguishing System › Piping
Issued 21 November 2017
Resolved
Repair broken fixed CO2 distribution line over #3 SSDG. SOLAS(09)II-2/21
Condition: Damaged By Earlier Event
Action required: 17 - Rectify deficiencies prior to departure
Resolved 24 November 2017
Resolution: CO2 pipe was repaired.
Fire Fighting › Fixed CO2 Fire Extinguishing System › Piping
Issued 21 November 2017
Resolved
Replace CO2 system dry rotted reel hose located in E/R adjacent to feed water pumps. SOLAS(09)II-2/14.2.1.2
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 22 January 2018
Resolved 3 January 2018
Resolution: Replacement verified by class surveyor. Class report attached to this activity.
Engineering › Steam System (auxiliary) › Valve, Relief
Issued 21 November 2017
Resolved
Prove all safety relief valves on steam aux systems have been satisfactorily tested. ABS 4-4-1/1
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 22 December 2017
Resolved 8 December 2017
Resolution: Aux steam system satisfactorily tested in the presence of class surveyor. A copy of the class report is attached to this activity.
Lifesaving › Launching Appliances › Winch Brake
Issued 21 November 2017
Resolved
Prove proper fall speeds of both life boats at both fully loaded, and fully equipped weights.
LSA 6.1.2.8 / 6.1.2.9
Action required: 705 - Other - as specified
Due 22 December 2017
Resolved 5 December 2017
Resolution: documentation provided
Operations/Management › Lifesaving › Op Readiness/Maintenance/Inspection
Issued 21 November 2017
Resolved
Launch and prove proper operation of STBD lifeboat.
46 CFR 91.25-10
Action required: 705 - Other - as specified
Due 1 December 2017
Resolved 24 November 2017
Resolution: Proper launch and operation of the starboard lifeboat observed by the class surveyor. A copy of the class report is attached to this activity.
Lifesaving › Lifebuoys › Buoyant Lifeline
Issued 21 November 2017
Resolved
Replace all yellow line on liferings with dark or UV protected line
Action required: 705 - Other - as specified
Resolved 22 November 2017
Resolution: Replaced all line.
Fire Fighting › Combustible Materials › Paints/Varnishes/Other Finishes
Issued 21 November 2017
Resolved
Remove excessive paint in storage bin aft of house port side.
Action required: 705 - Other - as specified
Resolved 23 November 2017
Resolution: removed
Lifesaving › Launching Appliances › Padeye
Issued 21 November 2017
Resolved
Conduct non-destructive testing of the both P & S lifeboat hook plates.
Action required: 60 - Rectify deficiencies prior to movement
Due 21 November 2017
Resolved 22 November 2017
Resolution: test conducted by international, all sat
Construction/Loadline › Structures › Transverse Bulkhead
Issued 21 November 2017
Resolved
Repair hole in reefer locker bulkhead port side.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 28 November 2017
Resolved 22 November 2017
Operations/Management › Navigation Safety › Navigation Underway, General
Issued 4 April 2017
Resolved
Prove proper operation of propulsion including bridge control of main diesel engine following repairs. Tug assist required if sea trials are needed to prove repairs. Vessel may depart fully manned with concurrence from Coast Guard following proof of proper operation of local control if repairs are not possible during this port call.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 4 April 2017
Resolution: Repairs to bridge MDE control made, ABS witnessed sat sea trials.
Fire Fighting › Fixed Fire Detection System › Control Panel
Issued 31 March 2017
Resolved
Repair alarms in the supervisory system circuit.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 1 April 2017
Resolved 1 April 2017
Resolution: Repaired and tested
Engineering › Steering Gear System › Actuator
Issued 8 October 2016
Resolved
No.2 steering gear unit is inop.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 8 October 2016
Resolved 8 October 2016
Resolution: The MI witnessed satisfactory tests of both steering gear units