Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 23 January 2026
…with no type recorded33
…past their stated due date1
Operational controls None recorded without a removal date
Years with a record 11 calendar years (2016–2026)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

WCY6713
Flag
UNITED STATES
Maury page id
psix-54761

Documentation record

Registered dimensions (L × B × D)61.3 ft × 20.3 ft × 7.7 ft
Registered tonnagegross 56 / net 38
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderATLANTIC & GULF BOAT BUILDING INC · PORT EVERGLADES, FL, UNITED STATES · built 1983
Hull materialAluminum
PropulsionDiesel Reduction
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing portBOSTON, MA
Endorsements, as the file codes themcw_un
DocumentationValid · issued 5 August 2025 · expires 30 September 2026
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it38 - Regulatory (Subpart C or D), Net Ton
56 - Regulatory (Subpart C or D), Gross Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Professional
The full record for this vessel

Behind this panel: 60 inspections, each with its date, unit and type; 49 deficiencies with the resolution recorded against each, 1 without one; operational controls, none recorded without a removal date; 1 other vessel inspected with it; 1 other recorded name; the documentation record: dimensions, tonnage, builder, hailing port and endorsements. Every line is a record the Coast Guard wrote; the counts above are the same counts as in the summary, and they are free.

Professional is $39 a month or $299 a year, or $19.99 a month locked for life at the founding rate, for the first 200 subscribers. It unlocks every detail section on every vessel page, fleet watch tied to your account, and ownership records on request. Already a subscriber? Sign in.

Maury does not score, rate or grade vessels, at any price.

Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 1972 to 2026, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspected as a tow unit · 1

The Coast Guard recorded this vessel and the following in the same inspection activity — normally a tug and the barges in its tow. A recreational or unclassed hull in the same activity is held and not published, so it does not appear here: these lists are a floor, not a complete manifest.

AURORA Passenger (Inspected) · MISLE 504368 · 24 September 2017 · activity 6275226

Inspection history · 60

23 January 2026 Appeal
Administrative · Sector Boston · USCG Northeast District (CGD-NE) · Activity 8309959
17 November 2025 Vessel Attendance · Drydock Exam · Internal Structural Exam
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 8265269
4 September 2025 COI Inspection · Internal Structural Exam
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 8208396
20 June 2025 Damage Survey
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 8163368
10 December 2024 Internal Structural Exam · Annual Inspection · Deficiency Check
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 8037517
21 March 2024 Examination of Repairs · Deficiency Check · Damage Survey · Administrative Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7883208
21 March 2024 Type not recorded
No type recorded · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7883238
24 January 2024 Administrative Inspection
Administrative · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7853884
16 November 2023 Annual Inspection · Internal Structural Exam
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7818830
24 October 2023 Hull Examination · Internal Structural Exam · Deficiency Check
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7810529
10 May 2023 In-Service Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7685286
6 December 2022 Annual Inspection · Deficiency Check · Internal Structural Exam
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7592153
30 November 2021 Annual Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7353402
19 October 2021 Hull Examination · Internal Structural Exam · Deficiency Check
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7331148
18 September 2020 Deficiency Check · COI Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7055142
9 December 2019 Deficiency Check · Annual Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6869747
25 October 2019 Hull Examination
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6841786
24 October 2019 Administrative Inspection
Administrative · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6839627
30 April 2019 Type not recorded
No type recorded · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6680227
21 December 2018 Annual Inspection · Deficiency Check
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6598831
6 March 2018 Type not recorded
No type recorded · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6366745
8 January 2018 Type not recorded
No type recorded · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6334086
14 December 2017 Annual Inspection · Deficiency Check
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6324450
30 November 2017 Damage Survey
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6315730
9 November 2017 Type not recorded
No type recorded · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6304011
25 October 2017 Type not recorded
No type recorded · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6296202
25 October 2017 Damage Survey · Deficiency Check
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6299511
16 October 2017 Hull Examination
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6288247
5 October 2017 Damage Survey · Deficiency Check
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6282595
5 October 2017 Type not recorded
No type recorded · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6285736
24 September 2017 Examination of Repairs · Damage Survey
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6275097
24 September 2017 Type not recorded
No type recorded · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6275226
4 July 2017 Type not recorded
No type recorded · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6198372
4 July 2017 Type not recorded
No type recorded · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6198380
4 July 2017 Type not recorded
No type recorded · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6198391
26 April 2017 Type not recorded
No type recorded · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6133377
26 April 2017 Type not recorded
No type recorded · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6133379
26 April 2017 Type not recorded
No type recorded · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6133380
26 April 2017 Type not recorded
No type recorded · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6133381
26 April 2017 Type not recorded
No type recorded · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6133383
26 April 2017 Type not recorded
No type recorded · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6133385
24 February 2017 Deficiency Check
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6094225
14 December 2016 Annual Inspection · Deficiency Check
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6057712
11 October 2016 Type not recorded
No type recorded · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6019860
11 October 2016 Type not recorded
No type recorded · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6019864
12 July 2016 Type not recorded
No type recorded · Sector Boston · USCG Northeast District (CGD-NE) · Activity 5938773
12 July 2016 Type not recorded
No type recorded · Sector Boston · USCG Northeast District (CGD-NE) · Activity 5938777
2 June 2016 Hull Examination
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 5896133
8 April 2016 Type not recorded
No type recorded · Sector Boston · USCG Northeast District (CGD-NE) · Activity 5849851
8 April 2016 Type not recorded
No type recorded · Sector Boston · USCG Northeast District (CGD-NE) · Activity 5849858
16 February 2016 Type not recorded
No type recorded · Sector Boston · USCG Northeast District (CGD-NE) · Activity 5815544
16 February 2016 Type not recorded
No type recorded · Sector Boston · USCG Northeast District (CGD-NE) · Activity 5815554
28 January 2016 Type not recorded
No type recorded · Sector Boston · USCG Northeast District (CGD-NE) · Activity 5805772
28 January 2016 Type not recorded
No type recorded · Sector Boston · USCG Northeast District (CGD-NE) · Activity 5805780
28 January 2016 Type not recorded
No type recorded · Sector Boston · USCG Northeast District (CGD-NE) · Activity 5806101
28 January 2016 Type not recorded
No type recorded · Sector Boston · USCG Northeast District (CGD-NE) · Activity 5806111
28 January 2016 Type not recorded
No type recorded · Sector Boston · USCG Northeast District (CGD-NE) · Activity 5806119
28 January 2016 Type not recorded
No type recorded · Sector Boston · USCG Northeast District (CGD-NE) · Activity 5806123
28 January 2016 Type not recorded
No type recorded · Sector Boston · USCG Northeast District (CGD-NE) · Activity 5806131
28 January 2016 Type not recorded
No type recorded · Sector Boston · USCG Northeast District (CGD-NE) · Activity 5806134

Deficiency record · 49

07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 4 September 2025 No resolution recorded
Controls [for fixed CO2 systems] shall be installed in an accessible location outside the space protected. Time delay bottle was installed inside the protected engine room space. System modification to be addressed IAW decision from Marine Safety Center (MSC) and prior 2025 hull credit. 46 CFR 181.20-10(b)(3)
Action required: 705 - Other - as specified
Due 31 October 2025 — due date passed with no resolution recorded
05 - Radio Communications › N/A - No Subsystem › VHF radio installation
Issued 4 September 2025 Resolved
Vessels operated solely within 20 nautical miles of land must be equipped with a VHF-DSC radiotelephone installation meeting the requirements of § 80.1101(c)(2). Input MMSI number into VHF radio/s. 47 CFR 80.905(a)(1)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 18 September 2025
Resolved 17 September 2025
Resolution: O/o sent objective evidence (picture) of MMSI on each VHF radio/s.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 4 September 2025 Resolved
Each life jacket must be marked with Type I retro-reflective material. Roughly 25% of the life jackets on board had deteriorated reflective tape that was no longer reflective. 46 CFR 185.604(h)
Action required: 10 - Deficiency Rectified
Resolved 4 September 2025
Resolution: Crew applied new reflective tape to life jackets during the inspection.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 4 September 2025 Resolved
Each ring life buoy with a floating waterlight must have a lanyard of at least 910 millimeters (3 feet) in length, but not more than 1,830 millimeters (6 feet), securing the waterlight around the body of the ring life buoy. Lifeline on waterlight for ring buoy located on aft of second deck was deteriorated and brittle. 46 CFR 180.70(d)(2)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 18 September 2025
Resolved 17 September 2025
Resolution: Lifeline was replaced.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 4 September 2025 Resolved
Each floating waterlight must be approved in accordance with § 161.010 in subchapter Q of this chapter, or other standard specified by the Commandant, including, but not limited to, approval series 160.110. Lifebuoy waterlight did not have a battery installed that met manufacturer instructions. 46 CFR 180.70(d)(1)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 18 September 2025
Resolved 17 September 2025
Resolution: O/o replaced battery for floating waterlight.
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 4 September 2025 Resolved
Each vessel must be equipped with at least two operable portable battery lights. One of these lights must be located at the operating station and the other at the access to the propulsion machinery space. Vessel had two portable lights in the machinery space ad none at the operating station. Both lights had low/dead batteries. 46 CFR 183.430
Action required: 16 - Rectify deficiencies w/in 14 days
Due 18 September 2025
Resolved 17 September 2025
Resolution: Operator replaced batteries in portable lights and relocated one to operating station.
02 - Structural Conditions › N/A - No Subsystem › Decks - cracking
Issued 10 December 2024 Resolved
The construction and arrangement of a vessel must allow the safe operation of the vessel in accordance with the terms of its Certificate of Inspection giving consideration to provisions for a seaworthy hull. The entire weld at deck level on the foreward bitt on the stbd side is cracked.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 10 December 2024
Resolution: PREPPED AND WELDED
02 - Structural Conditions › N/A - No Subsystem › Bulkheads - operational damage
Issued 10 December 2024 Resolved
A penetration in a watertight bulkhead must be as high and as far inboard in the bulkhead as practicable, and made watertight. The collision bulkhead and the bulkhead between the storage room and the engine room have both have unsealed penetrations stbd side outboard, and the collision bulkhead also has one amidships.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 December 2024
Resolved 2 January 2025
Resolution: penetrations sealed
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 10 December 2024 Resolved
All machinery and equipment must be installed and maintained in such a manner as to afford adequate protection from machinery failure. The belt on the stbd PTO (for bilge and fire) is heavily cracked and missing pieces.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 December 2024
Resolved 2 January 2025
Resolution: Belt replaced
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 10 December 2024 Resolved
Electrical equipment exposed to the weather must be watertight. The electrical outlet on the port side of the mast is not watertight.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 December 2024
Resolved 2 January 2025
Resolution: weathertight cover installed
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 10 May 2023 Resolved
If a garden hose is used as a fire hose, it should be of good commercial grade constructed of an inner rubber tube, plies of braided cotton reinforcement and an outer cover of equivalent material, and shall be fitted with a commercial garden hose nozzle of grade bronze or equivalent metal. Main deck fire hose station's garden hose was found to have severe kinking and deterioration of the outer layers of rubber and cotton reinforcement where the hose is attached to the fire station piping. 46 CFR 181.15-10(e)
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 10 May 2023
Resolved 10 May 2023
Resolution: Vessel's crew made satisfactory repairs to the hose connection by cutting out the deteriorated section of hose and making a new connection on the fire station piping with good section of hose.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 6 December 2022 Resolved
The scope of the annual inspection is the same as the inspection for certification but in less detail. Machinery was not inspected or tested due to main engines being removed for maintenance. Machinery to be inspected prior to carrying passengers. 46CFR 176.500(b)(ii) 701c
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 4 April 2023
Resolution: Machinery inspected.
04 - Emergency Systems › N/A - No Subsystem › Fire drills
Issued 6 December 2022 Resolved
The scope of the annual inspection is the same as the inspection for certification but in less detail. Drills and tests not conducted due to vessel being unable to operate main engines or get underway. Drills and tests to be conducted prior to carrying passengers. 46 CFR 176.500(b)(ii) 701c
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 4 April 2023
Resolution: Drills conducted and observed.
09 - Working and Living Conditions › 091 - Living Conditions › Electrical devices
Issued 6 December 2022 Resolved
Electrical equipment exposed to the weather must be watertight. Port running light wiring is exposed to weather and is not watertight. 46 CFR 183.210(b) 16c
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 20 December 2022
Resolved 21 December 2022
Resolution: Wiring repaired.
09 - Working and Living Conditions › 091 - Living Conditions › Electrical devices
Issued 6 December 2022 Resolved
Electrical equipment on a vessel must be installed and maintained to protect passengers, crew, other persons, and the vessel from electrical hazards, including fire, caused by or originating in electrical equipment, and electrical shock. The two outlets in the aft overhead of the passenger accommodation area show the hot and neutral reversed when tested via receptacle tester. 46 CFR 183.200(b) 16c
Condition: Design Flaw
Action required: 16 - Rectify deficiencies w/in 14 days
Due 20 December 2022
Resolved 21 December 2022
Resolution: Outlets repaired.
09 - Working and Living Conditions › 091 - Living Conditions › Electrical devices
Issued 6 December 2022 Resolved
Electrical equipment on a vessel must be installed and maintained to protect passengers, crew, other persons, and the vessel from electrical hazards, including fire, caused by or originating in electrical equipment, and electrical shock. Port galley GFCI outlet test shows that the hot and ground are reversed, and the GFCI is not functioning when tested via receptacle tester. 46 CFR 183.200(b)
Condition: Design Flaw
Action required: 16 - Rectify deficiencies w/in 14 days
Due 20 December 2022
Resolved 21 December 2022
Resolution: Outlet repaired.
09 - Working and Living Conditions › 091 - Living Conditions › Electrical devices
Issued 6 December 2022 Resolved
Electrical equipment exposed to the weather must be watertight. The electrical outlet on the port side of the mast is not watertight. 46 CFR 183.210 (b) 16c
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 20 December 2022
Resolved 21 December 2022
Resolution: Outlet removed from vessel.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 6 December 2022 Resolved
Nonmetallic hose may be used for wet exhaust systems provided it is especially adapted to resist the action of oil, acid, and heat, has a wall thickness sufficient to prevent collapsing or panting, and is double clamped where practicable. Two port side exhaust clamps were loose. 46 CFR 182.430 (e) 16c
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 20 December 2022
Resolved 21 December 2022
Resolution: Hose and clamps replaced correctly.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 6 December 2022 Resolved
Electrical equipment on a vessel must be installed and maintained to protect passengers, crew, other persons, and the vessel from electrical hazards, including fire, caused by or originating in electrical equipment, and electrical shock. Distribution panels A & B on the ER fwd bulkhead have open knockouts in the bottoms.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 18 April 2023
Resolved 20 April 2023
02 - Structural Conditions › N/A - No Subsystem › Wheelhouse -door -window
Issued 6 December 2022 Resolved
All passenger accommodations must be arranged and equipped to provide for the safety of the passengers in consideration of the route, modes of operation, and speed of the vessel. The 3rd window fwd from the port quarter in the pax acc area on the main deck is cracked about 6".
Condition: Damaged By Earlier Event
Action required: 16 - Rectify deficiencies w/in 14 days
Due 18 April 2023
Resolved 20 April 2023
04 - Emergency Systems › N/A - No Subsystem › Man Overboard Drill (MOB)
Issued 6 December 2022 Resolved
The master shall conduct sufficient drills and give sufficient instructions to make sure that all crew members are familiar with their duties during emergencies that necessitate abandoning ship or the recovery of persons who have fallen overboard. MOB drill using OSCAR was unsatisfactory. The crew was unfamiliar with the procedure to set up the block & tackle for retrieval, and the 2 deckhands were unable to recover OSCAR without assistance, which was still a long struggle. MI reccomended more training and possible improvements to the MOB procedures/equipment, and will return to observe another MOB drill prior to clearing deficiency.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 18 April 2023
Resolved 20 April 2023
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 18 September 2020 Resolved
All vessels shall be provided with a satisfactory arrangement for draining any watertight compartment. Forward most compartment's bilge pump did not have an adequate discharge flow when ran by the PTO. Have bilge pump provide an adequate flow when ran by the PTO.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 18 September 2020
Resolution: Vessel demonstrated adequate discharge from the compartment's bilge pump.
14 - Pollution Prevention › 144 - MARPOL Annex IV (Not Applicable to PSC Exams conducted in the U.S.) › Sewage discharge connection
Issued 18 September 2020 Resolved
A vessel with installed toilet facilities must have a marine sanitation device that complies with 33 CFR 159. The operator must secure each Type III sanitation device by an acceptable method such as: closing the valve and removing the handle, padlocking the overboard valve, or using non-releasable wire ties to hold the overboard valve closed. Vessel did not have an acceptable means of securing the sewage tank's overboard discharge. Provide an acceptable means to secure overboard discharge for sewage.
Condition: Placed in Improper Service
Action required: 10 - Deficiency Rectified
Resolved 18 September 2020
Resolution: Vessel removed handle to the sewage tank's overboard discharge.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 18 September 2020 Resolved
All electrical installations shall be to the satisfaction of the Marine Inspector. Wiring joints and splices shall be mechanically secure and made in junction boxes. Vessel's windshield wiper motor has exposed wires. Have wires meet the applicable regulation.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 October 2020
Resolved 2 October 2020
Resolution: Vessel removed wires that were exposed.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 9 December 2019 Resolved
All dead-end lines shall extend at least 2 inches past the last orifice and shall be closed with cap or plug. The piping leading to the fixed firefighting system discharge outlets in the engine room does not extend past the outlets. 46 CFR 181.20-20(d)
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 23 December 2019
Resolved 13 December 2019
Resolution: The piping leading to the fixed firefighting system discharge outlets in the engine room was extended past the discharge outlets.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 9 December 2019 Resolved
Battery terminals shall be of the soldered type and all connections shall be made to the battery terminals with permanent type connectors. All battery cables in machinery spaces are connected with wing nuts. 46 CFR 183.05-20(c)
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 23 December 2019
Resolved 13 December 2019
Resolution: All battery cables in machinery spaces are now connected with permanent type connectors.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 9 December 2019 Resolved
At each initial and subsequent inspection for certification, the marine inspector shall require that all observed unsafe practices and hazardous situations be corrected. Exposed wire connections were protruding from under the operating station. Wires were properly secured and the deficiency was rectified during the inspection. 46 CFR 176.25-50(a)
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 23 December 2019
Resolved 9 December 2019
Resolution: Wires were properly secured and the deficiency was rectified during the inspection.
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 21 December 2018 Resolved
Fire main, all piping, valves and fittings shall be in accordance with good marine practice suitable for the purpose intended. Rubber patch found leaking on outlet piping of fire pump during operation. Similar patch found on inlet side of pump. Piping must be connected to fire pump using appropriate fittings.
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Due 21 December 2018
Resolved 28 December 2018
Resolution: The piping connected to the fire pump was connected with appropriate fittings.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 21 December 2018 Resolved
Electrical equipment exposed to weather must be watertight. Open junction box found on stbd quarter without cover.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 January 2019
Resolved 28 December 2018
Resolution: Cover was replaced on junction box on starboard quarter.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 21 December 2018 Resolved
Each connection to a conductor must be made within an enclosure. Dead end wires found in the overhead of pilot house and in the engine room overhead near the forward hatch.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 January 2019
Resolved 28 December 2018
Resolution: Dead end wires in the pilot house and in the engine room were placed in an enclosure.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Railing, gangway, walkway and means for safe passage
Issued 21 December 2018 Resolved
Deck rails must be constructed to withstand a point load of 200 pounds. Crack found on railing located on the stern of the upper deck rail.
Condition: Damaged By Earlier Event
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 January 2019
Resolved 2 January 2019
Resolution: Crack on railing cleaned and rewelded, all sat.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 21 December 2018 Resolved
Materials and arrangements must be maintained to standards considered good marine practice. Found missing support clamps and multiple chafing points on hydraulic lines in forepeak. Hydraulic lines not properly supported on stbd outboard bulkheads in engine room and generator room.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 January 2019
Resolved 28 December 2018
Resolution: Additional supports were added to the hydraulic lines on the port and starboard side of the vessel.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 21 December 2018 Resolved
All cable and wires must be installed with metal supports not more than 24 inches apart. Found unsupported wires on port and stbd outer bulkheads in the engine room and generator space.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 January 2019
Resolved 28 December 2018
Resolution: Metal supports were added on wires on port and starboard outboard bulkheads.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Gauges, thermometers, etc
Issued 21 December 2018 Resolved
A voltmeter and amp meter must be provided and operational for a generator rated at 50 volts or more. Main switchboard 220 volt voltage meter indicated 300+ volts when not in operation.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 January 2019
Resolved 11 January 2019
Resolution: Meter replaced. Verified readings while on ship's generator. All sat.
09 - Working and Living Conditions › 092 - Working Conditions › Guards - fencing around dangerous machinery parts
Issued 21 December 2018 Resolved
Suitable covers and guards shall be installed in way of exposed machinery and gears. Starboard main engine missing guard.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 January 2019
Resolved 28 December 2018
Resolution: Satisfactory guard was added on exposed rotating machinery on starboard main engine.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Machinery space openings
Issued 21 December 2018 Resolved
Penetrations in watertight bulkheads must have means to make them water tight. Penetrations found in aft port corner of generator space that are not watertight.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 January 2019
Resolved 4 January 2019
Resolution: Watertight stuffing tube installed. All Sat
Engineering › Steering Gear System › Hydraulic Hose
Issued 14 December 2017 Resolved
Install proper metallic fittings on fwd bulkhead of engine room for hydraulic hoses for steering. 46 CFR 182.40-1 (old)
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 11 January 2018
Resolved 22 January 2018
Resolution: 1. Metallic fittings for the hydraulic hoses engine room.
Construction/Loadline › Structures › Machinery Space Opening
Issued 14 December 2017 Resolved
Cap multiple holes in fwd and aft engine room watertight bulkheads. 46 CFR 171.114 (old)
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 28 December 2017
Resolved 22 January 2018
Resolution: Holes in bulkhead capped.
Electrical › Electrical Distribution System (service) › Cable
Issued 14 December 2017 Resolved
Replace electrical cable for STBD NAV Light.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 28 December 2017
Resolved 22 January 2018
Resolution: Cable for nav lights replaced sat.
Electrical › Electrical Distribution System (service) › Distribution Panel Bus
Issued 14 December 2017 Resolved
Install covers on openings for 12/24 volt panel on pilot house.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 28 December 2017
Resolved 22 January 2018
Resolution: 12/24V panel openings sat.
Construction/Loadline › Structures › Machinery Space Opening
Issued 14 December 2017 Resolved
Cap through hull penetration on fwd STBD side of engine room.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 28 December 2017
Resolved 22 January 2018
Resolution: Hull penetration capped in engine room.
Lifesaving › Lifejacket/PFD (General) › Condition
Issued 14 December 2017 Resolved
Replace unserviceable KAPOK life jackets (07).
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 14 December 2017
Resolved 14 December 2017
Resolution: Life Jackets replaced.
Construction/Loadline › Hull › Bottom Plating
Issued 25 October 2017 Resolved
Vessel's hull corroded away and began taking water. Make permanent repairs to holed hull.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 1 November 2017
Resolution: Permanent repairs made to holed hull.
Engineering › Shafting/Propeller Arrangements › Propeller (fixed pitch)
Issued 6 October 2017 Resolved
Provide results of damage survey and make repairs to the satisfaction of the attending Marine Inspector
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 16 October 2017
Resolution: Damage survey provided; port propellor replaced.
Construction/Loadline › Hull › Hull Plating
Issued 24 September 2017 Resolved
not to operate prior to conducted repairs port side hull damage to the satisfaction to attending coast guard marine inspector.
Condition: Damaged By Earlier Event
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 29 September 2017
Resolution: Hull damage repaired to the satisfaction of attending Marine Inspector.
Construction/Loadline › Hull › Hull Plating
Issued 24 September 2017 Resolved
provide repair proposal to coast guard marine inspector for approval or repairs by 29SEP17 46CFR176.700.
Action required: 705 - Other - as specified
Due 29 September 2017
Resolved 29 September 2017
Resolution: Hull damage repaired to the satisfaction of attending Marine Inspector.
Construction/Loadline › Structures › Door
Issued 14 December 2016 Resolved
Dog on aft engine room door was missing repair dog by 27 DEC16.
Action required: 705 - Other - as specified
Due 31 January 2017
Resolved 24 February 2017
Resolution: Vessel rep. added operable dog to aft engine room door.
Fire Fighting › Fixed CO2 Fire Extinguishing System › Servicing
Issued 14 December 2016 Resolved
CO2 bottle from extinguishing system for engine room was missing safety cap, provide cap by 27DEC16.
Action required: 705 - Other - as specified
Due 27 December 2016
Resolved 3 January 2017
Resolution: cap replaced, cleared.
Fire Fighting › Fixed CO2 Fire Extinguishing System › Operating Controls
Issued 14 December 2016 Resolved
Relocate pressure switch for ventilation shutdown in fixed gas extinguishing system; shutdown must be located outside space protected.
Action required: 705 - Other - as specified
Due 31 January 2017
Resolved 24 February 2017
Resolution: Pressure switch was moved to a space forward of the engine room.

Recorded names · 1

ANNA (2008–2011). Names as the Coast Guard recorded them in incident records, with the years they appear; some are renames and some are spelling variants.