MAURY USCG vessel records Sign in
← All vessels

WILD THING II

WILD THING II is a 2002 public vessel, unclassified. The Coast Guard has recorded 23 inspections since 2002, most recently in May 2022, along with 10 deficiencies and 1 operational control.

Records from 2002 to 2022. Most recent: inspection, 26 May 2022.

Built
2002
Last inspected
26 May 2022
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

567814
Flag
UNITED STATES
—
Maury page id
psix-567814

Inspections, by type

…with no type recorded1
Years with a record 17 calendar years (2002–2022)
The 23 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 4 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Miscellaneous Vessel class in Maury's sources begin in 1979.

Documentation record

Tonnage as PSIX records itNot recorded
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspected as a tow unit · 2

The Coast Guard recorded this vessel and the following in the same inspection activity — normally a tug and the barges in its tow. A recreational or unclassed hull in the same activity is held and not published, so it does not appear here: these lists are a floor, not a complete manifest.

SWAMP KING Passenger (Inspected) · MISLE 613832 · 2 October 2004 · activity 2212334WIND KING Passenger (Inspected) · MISLE 625462 · 2 October 2004 · activity 2212334

Inspection history · 23

26 May 2022 In-Service Inspection · Administrative Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7488521
24 September 2021 Examination of Repairs · Damage Survey · Annual Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7319499
8 March 2021 Annual Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7152192
20 May 2020 Annual Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6956377
16 May 2019 Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6685783
19 February 2019 Drydock Exam · COI Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6628239
10 April 2018 Drydock Exam · Annual Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6379814
5 April 2017 Annual Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6106841
18 February 2016 Deficiency Check · Internal Structural Exam · Annual Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 5812631
6 March 2014 COI Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 4806678
15 May 2012 Simplified Stability Test · Hull Examination · Administrative Inspection · Annual Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 4295110
20 April 2009 COI Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3426324
3 June 2008 Annual Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3220398
27 July 2007 Hull Examination · Administrative Inspection · Annual Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3005176
2 October 2006 Simplified Stability Test · Administrative Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 2792056
18 August 2006 Administrative Inspection · Annual Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 2750099
25 July 2005 Annual Inspection
Physical examination · MIDET HARVEY CANAL DETAIL · USCG Heartland District (CGD-H) · Activity 2438968
15 November 2004 Administrative Inspection
Administrative · MIDET HARVEY CANAL DETAIL · USCG Heartland District (CGD-H) · Activity 2241447
2 October 2004 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 2212334
21 July 2004 COI Inspection
Physical examination · MIDET HARVEY CANAL DETAIL · USCG Heartland District (CGD-H) · Activity 2140334
10 July 2003 Annual Inspection
Physical examination · MIDET WEST DETAIL · USCG Heartland District (CGD-H) · Activity 1841489
20 June 2002 COI Inspection
Physical examination · MIDET HARVEY CANAL DETAIL · USCG Heartland District (CGD-H) · Activity 1633997
1 May 2002 Construction Oversight · Initial Certification
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1618659

Deficiency record · 10

01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 24 September 2021 Resolved
Repairs or alterations to the hull, machinery, or equipment that affect the safety of the vessel must not be made without the approval of the cognizant OCMI, except during an emergency. Vessel was swamped and sank in shallow water during Hurricane IDA. Vessel is to undergo a reinspection and drydock inspection prior to carrying passengers to the satisfaction of the cognizant OCMI.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 25 February 2022
Resolution: MI's completed damage survey and annual exam.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 8 March 2021 Resolved
Each battery must be located as high above the bilge as practicable, secured to protect against shifting with the roll and pitch of the vessel, and free from exposure to water splash or spray. MI Observed vessel's battery bank completley full of water. 46 CFR 183.350(b) 10C
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 25 March 2021
Resolution: Vessel Rep drained battery box and ensured cover was properly secured.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 8 March 2021 Resolved
An adult life jacket must be provided for each person carried on board a vessel. In addition, a number of child size life jackets equal to at least 10% of the number of persons permitted on board must be provided. MI observed 01 child lifejacket was wasted and not serviceable. 46 CFR 180.71(b) 10C
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 25 March 2021
Resolution: Vessel Rep replaced child life jacket with a servicable life jacket
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 8 March 2021 Resolved
At least one ring life buoy must be fitted with a lifeline. If more than one ring life buoy is carried, at least one must not have a lifeline attached. MI observed the lifeline was not attached to the ring life buoy. 46 CFR 180.70(c) 10C
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 25 March 2021
Resolution: Vessel Rep properly attached lifeline to the ring life buoy
11 - Life Saving Appliances › N/A - No Subsystem › Stowage and provision of liferafts
Issued 8 March 2021 Resolved
The number and identification of the items stowed inside, and their sizes, must be marked in clearly legible letters and numbers on each container for life jackets and immersion suits. MI observed the forward hatch that stowes the vessel's life jackets was not labeled. 46 CFR 185.604(f) 10C
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 25 March 2021
Resolution: Vessel Rep labeled forward hatch with life jacket stowage.
02 - Structural Conditions › N/A - No Subsystem › Ballast, fuel and other tanks
Issued 8 March 2021 Resolved
Where flexible nonmetallic hose is permitted for use in piping systems by this section, it must meet SAE J-1942. Fuel tank venting line and supply lines were chaffing and need replacing/proper chaffing gear. 46 CFR 720 (e) 10C
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 25 March 2021
Resolution: Vessel Rep replaced fuel supply line and added chaffing gear to fuel tank venting line
Lifesaving › Lifebuoys › Serviceable
Issued 18 February 2016 Resolved
Vsl's ring life buoy has a puncture. Provide approved ring life buoy with appropriate markings and new line to satisfaction of attending CG Marine Inspector.
Condition: Damaged By Earlier Event
Action required: 701 - Prior to carriage of passengers/cargo
Due 18 February 2016
Resolved 19 February 2016
Resolution: Vsl provided proof of new ring life buoy with appropriate markings.
Engineering › Fuel Oil Storage/Transfer System › Hose
Issued 18 February 2016 Resolved
The exterior covering of the vsl's fuel hoses are deteriorated. Replace fuel hoses to satisfaction of attending CG Marine Inspector.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 3 March 2016
Resolved 4 March 2016
Resolution: Replaced to satisfaction of Marine Inspectors.
Stability › Incline Test › General
Issued 25 October 2007 Resolved
In accordance with 46 CFR 178.330, conduct a satisfactory simplified stability proof test in the presence of a CG Marine Inspector or provide evidence showing the subject vessel is properly sistered to another vessel which has completed a satisfactory simplified stability proof test.
Condition: Unknown
Due 24 November 2007
Resolved 16 November 2007
Resolution: See narrative for activity 2792056.
Documentation › Certificates/Documents › Stability Letter
Issued 18 August 2006 Resolved
Conduct a Simplified Stability Test to the satisfaction of the local OCMI.
Due 18 September 2006
Resolved 19 September 2006
Resolution: Witnessed satisfactory simplified stability test conducted by Arthur D. Daren, INC.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.