Records from 2003 to 2025. Most recent: inspection, 31 March 2025.
Documentation record
Registered dimensions (L × B × D)297.5 ft × 54.0 ft × 12.0 ft
Registered tonnagegross 1,619 / net 1,619
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderTRINITY MARINE PRODUCTS · ASHLAND CITY, TN, UNITED STATES · built 2002
Hull materialSteel
PropulsionNot recorded
Hull shapeBox
Hull configurationMonohull
Hailing portMEMPHIS, TN
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 28 May 2026 · expires 30 June 2027
Service, as the file records itTank Barge
Hull formbarge (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it1619 - Simplified, Gross Ton
5414 - Displacement, Net Ton
1619 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Inspection history · 29
31 March 2025
Examination of Repairs · Deficiency Check
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 8100014
4 January 2025
Administrative Inspection
Administrative · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 8057564
10 January 2023
COI Inspection · Drydock Exam · Internal Structural Exam · MTSA Verification · Cargo Tank Internal
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 7617467
5 February 2018
Internal Structural Exam · MTSA Verification · Examination of Repairs · COI Inspection
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 6345456
4 January 2017
Administrative Inspection
Administrative · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6065678
23 December 2016
Administrative Inspection
Administrative · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6061782
1 September 2016
Administrative Inspection · Annual Inspection · MTSA Verification
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 5997024
16 November 2015
Periodic Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 5762216
13 November 2014
Administrative Inspection · Annual Inspection
Physical examination · Sector Lower Mississippi · USCG Heartland District (CGD-H) · Activity 5030804
14 November 2013
MTSA Verification · Administrative Inspection · Annual Inspection
Physical examination · Sector Lower Mississippi · USCG Heartland District (CGD-H) · Activity 4753125
24 October 2012
COI Inspection · Internal Structural Exam · MTSA Verification · Drydock Exam · Cargo Tank Internal
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 4469291
20 February 2012
MTSA Verification · Annual Inspection
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 4247692
6 October 2010
MTSA Verification · Periodic Inspection
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3864468
21 December 2009
Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Vicksburg · USCG Heartland District (CGD-H) · Activity 3654520
3 February 2009
Annual Inspection · MTSA Verification
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3411671
1 February 2009
Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3404011
23 November 2007
COI Inspection · Internal Structural Exam · MTSA Verification · Examination of Repairs
Physical examination · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 3103192
14 July 2007
Type not recorded
No type recorded · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 2996632
31 October 2006
Annual Inspection
Physical examination · Marine Safety Unit Huntington · USCG Heartland District (CGD-H) · Activity 2811545
15 June 2006
Security Plan Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2680312
13 March 2006
Periodic Inspection
Physical examination · Marine Safety Unit Huntington · USCG Heartland District (CGD-H) · Activity 2602028
12 August 2005
Type not recorded
No type recorded · Sector Lower Mississippi · USCG Heartland District (CGD-H) · Activity 2464634
3 March 2005
MTSA Verification · Annual Inspection
Physical examination · MIDET HARVEY CANAL DETAIL · USCG Heartland District (CGD-H) · Activity 2302647
26 May 2004
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 2079182
15 March 2004
Annual Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 2024539
22 December 2003
Security Plan Review - ASP
Administrative · Marine Safety Center (MSC) · Activity 1968344
13 June 2003
Examination of Repairs
Physical examination · MIDET WEST DETAIL · USCG Heartland District (CGD-H) · Activity 1812937
30 May 2003
Permit to Proceed · Damage Survey
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1805775
14 April 2003
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1784290
Construction/Loadline › Hull
Issued 30 May 2003
Resolved
Crop and renew one (1) section of side shell plate located in # 3 port void approximately 27' x 8' x 3/8". All repairs and testing shall be to the satisfaction of the attending marine inspector LEGACY COMPONENT DESC: Side Shell
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 30 June 2003
Resolved 30 May 2003
Construction/Loadline › Hull
Issued 30 May 2003
Resolved
Crop and renew one (1) section of bilge knuckle in way of #3 port void approximately 27' x 4' x 3/4". All repairs and testing shall be to the satisfaction of the attending marine inspector. LEGACY COMPONENT DESC: Bottom Plating
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 30 June 2003
Resolved 13 June 2003
Construction/Loadline › Hull
Issued 30 May 2003
Resolved
Crop and renew one (1) section of bottom plate in way of # 3 stbd void approximately 24" x 27' x 1/2". All repairs and testing shall be to the satisfaction of the attending marine inspector. LEGACY COMPONENT DESC: Bottom Plating
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 30 June 2003
Resolved 13 June 2003
Construction/Loadline › Hull
Issued 30 May 2003
Resolved
Crop and renew three (3) 6" x 10' channel in way of # 3 stbd void. LEGACY COMPONENT DESC: Transverse Frame
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 30 June 2003
Resolved 13 June 2003
Construction/Loadline › Hull
Issued 30 May 2003
Resolved
Crop and renew three (3) 10" x 10' channel in way # 3 stbd void. LEGACY COMPONENT DESC: Transverse Frame
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 30 June 2003
Resolved 13 June 2003
Construction/Loadline › Hull
Issued 30 May 2003
Resolved
Crop and renew six (6) 38" x 3" x 3" x 3/8" diagonally stiffeners in way of # 3 stbd void. LEGACY COMPONENT DESC: Stiffener
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 30 June 2003
Resolved 13 June 2003
Construction/Loadline › Hull
Issued 30 May 2003
Resolved
Crop and renew three (3) 25" x 4" x 4' x 3/8" horizontal stiffeners in way # 3 port void. LEGACY COMPONENT DESC: Stiffener
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 30 June 2003
Resolved 13 June 2003
Construction/Loadline › Hull
Issued 30 May 2003
Resolved
Crop and renew one (1) 27' x 24" x 1/2" bottom longitudinal in way of # 3 stbd void. LEGACY COMPONENT DESC: Longitudinal Frame
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 30 June 2003
Resolved 13 June 2003
Construction/Loadline › Hull
Issued 30 May 2003
Resolved
Crop and renew six (6) 27' x 3" x 5" x 3/8" side longitudinals in way of # 3 port void. LEGACY COMPONENT DESC: Longitudinal Frame
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 30 June 2003
Resolved 13 June 2003
Construction/Loadline › Hull
Issued 30 May 2003
Resolved
Crop and renew three (3) 33" x 48" x 3/8" deep web frames in way of # 3 port void. LEGACY COMPONENT DESC: Deep Web
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 30 June 2003
Resolved 13 June 2003