MAURY USCG vessel records
← All vessels

TENNESSEE

TENNESSEE is a 2002 tank barge. The Coast Guard has recorded 48 inspections since 2003, most recently in February 2025, along with 23 deficiencies — 1 with no resolution recorded —, 2 operational controls, 1 with no removal date recorded and 2 casualty investigations between 2014 and 2016.

Records from 2003 to 2025. Most recent: inspection, 4 February 2025.

Built
2002
Last inspected
4 February 2025
Documentation
Valid · documentation file of 10 August 2026
Controls
1 with no removal date recorded

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Barge class in Maury's sources begin in 1972.

Inspection record

Last inspected 4 February 2025
…with no type recorded4
Operational controls 1 with no removal date recorded
Years with a record 21 calendar years (2003–2025)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

WDB2986
603740
Flag
UNITED STATES
Maury page id
psix-603740

Documentation record

Registered dimensions (L × B × D)332.0 ft × 74.0 ft × 25.0 ft
Registered tonnagegross 5,159 / net 5,159
ITC dimensions (L × B × D)316.8 ft × 74.0 ft × 25.0 ft
ITC tonnagegross 5,688 / net 3,739
BuilderSOUTHEASTERN NEW ENGLAND SHIPBUILDING CORP · NORTH KINGSTOWN, RI, UNITED STATES · built 2002
Hull materialSteel
PropulsionUNSPECIFIED
Hull shapeBox
Hull configurationMonohull
Hailing portWILMINGTON, DE
Trade endorsementsCoastwise, unrestricted, Registry
DocumentationValid · issued 22 October 2025 · expires 31 October 2026
Service, as the file records itTank Barge
Hull formbarge (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it5159 - Simplified, Net Ton
3739 - Convention (Subpart B), Net Ton
12238 - Dead Weight, Ton
5159 - Simplified, Gross Ton
5688 - Convention (Subpart B), Gross Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 1972 to 2026 for this class, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspected as a tow unit · 2

The Coast Guard recorded this vessel and the following in the same inspection activity — normally a tug and the barges in its tow. A recreational or unclassed hull in the same activity is held and not published, so it does not appear here: these lists are a floor, not a complete manifest.

MAERSK KARACHI Freight Ship · MISLE 650962 · 10 January 2022 · activity 7378799MARY TURECAMO Towing Vessel · MISLE 211776 · 8 February 2016 · activity 5811199MARY TURECAMO Towing Vessel · MISLE 211776 · 4 May 2014 · activity 4853265

Inspection history · 48

4 February 2025 Deficiency Check
Physical examination · Resident Inspection Office Ponce · USCG Southeast District (CGD-SE) · Activity 8074631
29 December 2024 Administrative Inspection · Deficiency Check
Physical examination · Resident Inspection Office Ponce · USCG Southeast District (CGD-SE) · Activity 8051677
16 December 2024 Internal Structural Exam · Administrative Inspection
Physical examination · Resident Inspection Office Ponce · USCG Southeast District (CGD-SE) · Activity 8047978
13 December 2024 MARPOL Annex I Examination · MARPOL Annex VI Survey · Periodic Inspection
Physical examination · Resident Inspection Office Ponce · USCG Southeast District (CGD-SE) · Activity 8046997
25 January 2024 Deficiency Check · Annual Inspection
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 7853844
18 January 2024 Administrative Inspection
Administrative · Resident Inspection Office Ponce · USCG Southeast District (CGD-SE) · Activity 7850882
8 January 2024 Deficiency Check · Examination of Repairs
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 7846465
20 September 2022 Hull Examination · Examination of Repairs · COI Inspection · Internal Structural Exam
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7562946
11 March 2022 MTSA Verification · Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7410341
7 February 2022 Administrative Inspection
Administrative · Resident Inspection Office Ponce · USCG Southeast District (CGD-SE) · Activity 7391735
10 January 2022 Bulk Liquid Transfer Monitor
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 7378799
10 March 2021 Examination of Repairs · In-Service Inspection · Administrative Inspection · DAPI Audit · MTSA Verification · Periodic Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7156915
27 May 2020 Administrative Inspection
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 6961874
19 May 2020 Administrative Inspection
Administrative · Commandant (CG-CVC) · Activity 6955934
28 April 2020 Deficiency Check · Annual Inspection · MARPOL Annex VI Survey · MARPOL Annex I Examination · MTSA/ISPS Verification
Physical examination · Resident Inspection Office Ponce · USCG Southeast District (CGD-SE) · Activity 6944451
13 February 2020 Internal Structural Exam
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 6904084
7 March 2019 MARPOL Annex I Examination · Annual Inspection · MARPOL Annex VI Survey · MTSA Verification
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6637753
28 February 2018 Drydock Exam · Cargo Tank Internal · MTSA Verification · Internal Structural Exam · COI Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6363082
20 June 2017 Annual Inspection · MTSA Verification
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6181062
10 May 2016 MTSA Verification · Periodic Inspection · Construction Oversight · Drydock Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 5873347
8 February 2016 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 5811199
5 February 2016 Damage Survey
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 5810434
23 September 2015 Damage Survey
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 5726887
18 June 2015 Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 5156604
22 May 2015 MTSA Verification · Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 5131829
6 February 2015 Internal Structural Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 5064928
23 January 2015 Administrative Inspection
Administrative · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 5057815
4 May 2014 Type not recorded
No type recorded · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 4853265
22 April 2014 MTSA Verification · Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 4841426
21 March 2012 MTSA Verification · Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 4268567
4 November 2011 Administrative Inspection
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 4174634
16 August 2011 Administrative Inspection
Administrative · Sector Virginia · USCG East District (CGD-E) · Activity 4119578
13 August 2011 Damage Survey
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 4116148
24 February 2010 Internal Structural Exam · Annual Inspection
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 3685832
22 April 2009 Administrative Inspection
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 3458568
12 March 2009 Annual Inspection
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 3433576
10 July 2008 Type not recorded
No type recorded · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 3263564
30 June 2008 Deficiency Check
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 3252841
30 January 2008 COI Inspection · MTSA Verification · Hull Examination · Internal Structural Exam · Cargo Tank Internal
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 3138551
24 July 2007 MTSA Verification · Annual Inspection
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 2900774
6 February 2007 MARPOL Annex I Examination
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 2867816
11 April 2006 Periodic Inspection · MTSA Verification
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 2623811
13 May 2005 Annual Inspection · MTSA Verification · Internal Structural Exam · Hull Examination
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 2356787
12 May 2004 MARPOL Annex I Examination · Annual Inspection
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 2067356
30 April 2004 Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 2056043
28 July 2003 Administrative Inspection
Administrative · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1860210
9 April 2003 Construction Oversight · COI Inspection
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1770809
26 February 2003 Hull Examination · Cargo Tank Internal · Initial Certification · Construction Oversight
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1722305

Deficiency record · 23

06 - Cargo Operations Including Equipment › N/A - No Subsystem › Cargo operation
Issued 13 December 2024 No resolution recorded
Operational tests and checks of all safety and limit controls, combustion controls, programming controls, and safety relief valves must be conducted by the owner, chief engineer, or person in charge at the inspection for certification, periodic inspection. Thermal fluid heater shall not be used until the test mentioned above are conducted in the presence of the attending MI. 46CFR61.30-20
Action required: 705 - Other - as specified
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Cargo operation
Issued 13 December 2024 Resolved
A pressure gage shall be installed for each pump discharge, and it shall be located at a point visible with respect to the pump controls. Install pressure gauges as required above. 46CFR32.50-5
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 December 2024
Resolved 29 December 2024
Resolution: Attending MI received photo evidence clearing deficiency.
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Cargo operation
Issued 13 December 2024 Resolved
Each cargo tank of a tank barge must have one of the following liquid overfill protection arrangements: (1) A system meeting the requirements of 46 CFR 39.2007, that Includes a self-contained power supply; Is powered by generators on the barge. Repair back up power for overfill protection device by replacing battery charger with in kind marine battery charger.Vessel is not authorized to load cargo until this requirement is fulfilled. 46CFR39.2009 (a) (1)
Action required: 705 - Other - as specified
Resolved 29 December 2024
Resolution: Attending MI received photo evidence clearing deficiency.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 13 December 2024 Resolved
Prime movers must meet § 58.01-5 and subpart 58.10 of this chapter except. Provide test verification of all prime movers over speed shut-downs and lube oil shut downs. 46CFR 111.12-
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 December 2024
Resolved 11 February 2025
Resolution: Attending MI received video evidence showing the performance of oil pressure shutdowns.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 13 December 2024 Resolved
There must be ground detection for each: Lighting system; and Power or lighting distribution system that is isolated from the ship's service power and lighting system by transformers, motor generator sets, or other devices. Repair ground detection for 280v located in vessels accommodations. 46CFR111.05-21
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 December 2024
Resolved 29 December 2024
Resolution: Attending MI received photo evidence clearing deficiency.
09 - Working and Living Conditions › 092 - Working Conditions › Lighting (Working spaces)
Issued 13 December 2024 Resolved
Sufficient illumination must be provided by the emergency lighting source under emergency conditions to effect damage control procedures and to provide for safe egress from each space. Repair hallway emergency light. 46 CFR 111.75-15(c)(2)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 December 2024
Resolved 29 December 2024
Resolution: Attending MI received photo evidence clearing deficiency.
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Other (cargo)
Issued 25 January 2024 Resolved
33 CFR 155.480 (b) Each tank vessel with a cargo capacity of 1,000 or more cubic meters (approximately 6,290 barrels), loading oil or oil residue as cargo, must have one overfill device that is permanently installed on each cargo tank and meets the requirements of this section. The #1 port and starboard cargo tank liquid over fill protection are not operating as designed. A visual watch shall be maintained at the local gauging device with a tanker-man until loading is completed and provide effective means of communication.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 8 February 2024
Resolved 26 January 2024
Resolution: Repairs to the alarm panel were made. All test SAT.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 25 January 2024 Resolved
46 CFR 111.15-30 Each battery charger enclosure must meet § 111.01–9. Additionally, each charger must be suitable for the size and type of battery installation that it serves. Battery charger was inoperable with dead end wires. Repair or replace the charger and secure the dead end wires.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 February 2024
Resolved 2 February 2024
Resolution: received photographic evidence of the newly installed battery charger.
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Other (cargo)
Issued 28 April 2020 Resolved
Overfill protection system for Cargo Tank 1, P & S is inoperative. System to be repaired prior to using Vapor Control System.
Action required: 705 - Other - as specified
Resolved 24 June 2020
14 - Pollution Prevention › 141 - MARPOL Annex I › Other (MARPOL Annex I)
Issued 28 April 2020 Resolved
The SOPEP shall consist at least of the authorities or persons to be contacted in the event of an oil pollution incident. SOPEP onboard has not been updated since 2017 and not entries made in the record of changes has not been updated.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 5 May 2020
05 - Radio Communications › N/A - No Subsystem › Other (radio communication)
Issued 28 April 2020 Resolved
A sign shall be placed in radio room warning against the use of radio equipment during transfer of Grades A,B,C liquids except by permission of seniot deck officer. No such warning is posted on vessel.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 30 April 2020
Deck/Cargo › Mooring/Anchoring › Anchor Cable
Issued 5 February 2016 Resolved
Replace anchor cable and reattach anchor to the satisfaction of the attending Coast Guard Marine Inspector.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 19 February 2016
Resolved 8 February 2016
Resolution: Received pictures of the anchor reattached to a newly installed anchor cable.
Deck/Cargo › Mooring/Anchoring › Anchor Chain (general)
Issued 23 September 2015 Resolved
Have ABS approve repairs to the pear link on the anchor chain.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 30 September 2015
Resolved 23 September 2015
Resolution: Recieved class report from ABS approving the repair to the pear link on the anchor chain.
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Closure Devices
Issued 22 May 2015 Resolved
Cargo piping valve position (open/closed) indicators have been removed. Previous CG policy permitting the use of ropes for valve position indicators has been cancelled. Return to original operating conditions, allowing for valve position indication.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 2 July 2015
Resolved 18 June 2015
Resolution: Vessel installed valve position indicators, all sat.
Construction/Loadline › Hull › Stiffener
Issued 6 February 2015 Resolved
Correct deficienies notated on the worklist dated 06 FEB 15. Activity # 5064928
Action required: 705 - Other - as specified
Due 31 March 2018
Resolved 20 June 2016
Resolution: Verified repairs of worklist items.
Deck/Cargo › Vapor Control Systems › Piping/Hoses
Issued 22 April 2014 Resolved
The last 1 meter of vapor control system piping needs to be painted IAW 46CFR39.20-3(d). The VCS piping has green paint at the discharge end. 46CFR39.20-3(d)
Action required: 705 - Other - as specified
Due 28 May 2014
Resolved 22 May 2014
Resolution: Received photo from company rep showing the correct painting IAW 46CFR39.20-3(d).
Electrical › Electrical Distribution System (service) › Ground Detection
Issued 22 April 2014 Resolved
Ground detection is required on the 120/240 Volt distribution panels. Electrical plans for the modification is required to local OCMI office before actual installation of ground detection components. 45CFR111.05-21.
Action required: 705 - Other - as specified
Due 28 July 2014
Resolved 28 July 2014
Resolution: Received service report and pictures attesting the proper installation and operation of the ground detection system. See attached files in MISCLE Activity # 1978763
Engineering › Fuel Oil Service System › Hose
Issued 22 April 2014 Resolved
Replace two flexible hoses on the port side cargo pump engine with a combination of metal piping and approved nonmetallic hoses less than 30" in length. 46CFR56.60-25(b)2
Action required: 705 - Other - as specified
Due 28 May 2014
Resolved 10 May 2014
Resolution: Received company representative email with photo proving the deficiency is rectified.
Electrical › Electrical Distribution System (service) › Panelboard
Issued 30 January 2008 Resolved
Identify and label breakers in the galley.
Action required: 705 - Other - as specified
Due 3 April 2008
Resolved 5 March 2008
Resolution: Breakers correctly labeled and posted.
Documentation › Safety/Response Plans/Programs › Fire Control Plans
Issued 30 January 2008 Resolved
Submit plan approval (USCG/ ABS) for new instillation of NOTIFIER SFP-2404 fire alarm system.
Action required: 705 - Other - as specified
Due 3 May 2008
Resolved 30 June 2008
Resolution: Attended vessel; verified proper installation and operability.
Engineering › Fuel Oil Service System › Filter
Issued 13 May 2005 Resolved
REPLACE PETCOCKS ON RACOR FILTERS WITH PLUG ACCEPTING FITTINGS AS NECESSARY.
Condition: Improper Installation
Due 26 June 2005
Resolved 27 May 2005
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Piping
Issued 13 May 2005 Resolved
PROPERLY STENCIL ALL CARGO HOSES AND PIPING TO INDICATE LATEST HYDRO-TEST DATE AS NECESSARY. **STENCIL DATE SHOULD MATCH THAT OF GULF MARINE PIPE TEST CERTIFICATE.
Due 26 June 2005
Resolved 27 May 2005
Electrical › Electrical Distribution System (service) › Circuit Breaker
Issued 13 May 2005 Resolved
PROPERLY MARK RANGE CIRCUIT BREAKER TO INDICATE EMERGENCY SHUTDOWN FOR ELECTRIC RANGE.
Due 26 June 2005
Resolved 27 May 2005

Casualty record · 2

4 May 2014Routine · role: Involved in a Marine Casualty · activity 4853265
8 February 2016Routine · role: Involved in a Marine Casualty · activity 5811199
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.