This record may be incomplete: the most recent inspection recorded for this vessel was 6 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 2016.
Every line above is a count of records the US Coast Guard wrote, or a date it recorded.
A blank resolution means none was recorded in this data; it does not establish that a
deficiency is outstanding. Years with a record are calendar years in which a record
exists, not years in service. What Maury does
not do.
Tonnage as PSIX records it39272 - Convention (Subpart B), Gross Ton 20743 - Convention (Subpart B), Net Ton 70392 - Dead Weight, Metric Ton 82979 - Displacement, Metric Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Professional
The full record for this vessel
Behind this panel: 12 inspections, each with its date, unit and type; 4 deficiencies with the resolution recorded against each; 1 operational control with no removal date recorded; 2 other vessels inspected with it; no other recorded names; no NVDC documentation record for this Official Number. Every line is a record the Coast
Guard wrote; the counts above are the same counts as in the summary, and they are free.
Professional is $39 a month or $299 a year,
or $19.99 a month locked for life at the founding rate, for the first 200 subscribers. It unlocks
every detail section on every vessel page, fleet watch tied to your account, and ownership records
on request. Already a subscriber? Sign in.
Maury does not score, rate or grade vessels, at any price.
Vessel history report
Every record for this hull, in one document — $299
Every recorded inspection, 1972 to
2026, in one chronology · every deficiency, with system, dates
and resolution · operational controls imposed and removed · every name this
hull has been recorded under · the vessels it was inspected alongside, and when
· how its record compares with hulls of similar age and size, as a fact about the
population and never a judgement about this vessel.
This report is in development and is not for sale yet. There is
no date, and nothing is charged. Leave an email and we will tell you when it exists, once.
Used only to tell you when the report exists.
Not shared, not sold, and not added to a mailing list.
The Coast Guard recorded this vessel and the following in the same
inspection activity — normally a tug and the barges in its tow. A recreational or
unclassed hull in the same activity is held and not published, so it does not appear
here: these lists are a floor, not a complete manifest.
Documentation › Safety Management System › Reports and Analysis Procedures
Issued 15 November 2016Resolved
74SOLAS(2014 CONS.)IX/3.1 ISM PART A, 10.2.2 The company should ensure that any non-conformity is reported, with its possible cause, if known. PSCO discovered temporary piping repairs on the IGS, connecting to the atmosphere vent piping. Vessel could not provide proof that this temporary repair was reported to the company, piping in need of permanent repairs. 40ac.
Condition: Invalid
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 17 November 2016
Resolution: The identified piping has now been permanently repaired by renewal of the holed section. Following the repair the piping was tested under pressure of 950 millimetre water gauge with no leakage noted.
Documentation › Safety/Response Plans/Programs › Fire Control Plans
Issued 15 November 2016Resolved
74SOLAS(2001 CONS.)II-2/20 Fire control plans and booklets shall be kept up-to-date, any alterations being recorded thereon as soon as practical. Stairtower doors do not have self-closing fire fire door symbols indicated, plus various fire control plans have amendments w/o class approval. 50c.
Condition: Invalid
Action required: 705 - Other - as specified
Due 15 December 2016
Resolved 17 November 2016
Resolution: After removal of the fire plans it was confirmed the self-closing door symbols were as per the fire planlegend but difficult to see under the perspex cover. These have now been remarked in in order to show more clearly that the doors are self-closing.
Fire Fighting › Structural - A Class Divisions › Service Spaces
Issued 15 November 2016Resolved
74SOLAS(2014 CONS.)II-2/14.2.1.1.1 The following fire protection systems shall be kept in good order: structural fire protection including fire resisting divisions, and protecting of openings and penetrations in these division. PSCO found a penetration of a Class A fire division, the duct/pipe/cable space penetration into the linen locker, C-Deck. 50c.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 15 December 2016
Resolved 17 November 2016
Resolution: The fire division bulkhead penetration has now been sealed and found satisfactorily to maintain the A-0 rating.
Condition: Design Flaw
Action required: 17 - Rectify deficiencies prior to departure
Due 23 March 2016
Resolved 29 March 2016
Resolution: Vessel submitted tech report indicating a new GPS has been installed and is operating normally at this time. All connected equipment has good GPS data.