Records from 1992 to 2025. Most recent: inspection, 6 May 2025.
Inspection history · 33
6 May 2025
COI Inspection · Deficiency Check
Physical examination · Marine Safety Unit Paducah · USCG Heartland District (CGD-H) · Activity 8121704
6 May 2025
DAPI Audit
Administrative · Marine Safety Unit Paducah · USCG Heartland District (CGD-H) · Activity 8129717
30 September 2024
Administrative Inspection · Deficiency Check
Physical examination · Marine Safety Unit Paducah · USCG Heartland District (CGD-H) · Activity 8011903
29 August 2024
In-Service Inspection · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7992627
19 April 2024
Damage Survey · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7898475
11 June 2020
Administrative Inspection · Initial Certification
Physical examination · Marine Safety Unit Paducah · USCG Heartland District (CGD-H) · Activity 6977099
2 January 2020
Type not recorded
No type recorded · USCGC SAWFISH (WPB 87357) · USCG Southeast District (CGD-SE) · Activity 6885498
21 December 2019
Type not recorded
No type recorded · Marine Safety Unit Paducah · USCG Heartland District (CGD-H) · Activity 6885594
15 December 2016
Type not recorded
No type recorded · Marine Safety Unit Vicksburg · USCG Heartland District (CGD-H) · Activity 6058872
2 August 2016
Type not recorded
No type recorded · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 5963519
7 March 2016
Type not recorded
No type recorded · Marine Safety Unit Vicksburg · USCG Heartland District (CGD-H) · Activity 5828378
5 January 2015
Type not recorded
No type recorded · Marine Safety Unit Paducah · USCG Heartland District (CGD-H) · Activity 5047935
26 September 2014
Type not recorded
No type recorded · Marine Safety Unit Vicksburg · USCG Heartland District (CGD-H) · Activity 4992467
24 September 2014
Type not recorded
No type recorded · Marine Safety Unit Vicksburg · USCG Heartland District (CGD-H) · Activity 4991668
12 August 2014
Industry Initiated Exam
Physical examination · Marine Safety Unit Paducah · USCG Heartland District (CGD-H) · Activity 4962381
13 August 2013
Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 4685986
22 February 2013
Type not recorded
No type recorded · Station New Orleans · USCG Heartland District (CGD-H) · Activity 4537841
19 July 2012
Type not recorded
No type recorded · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 4384728
17 July 2012
Type not recorded
No type recorded · Marine Safety Detachment Quad Cities · USCG Heartland District (CGD-H) · Activity 4381506
3 January 2011
Industry Initiated Exam · Deficiency Check
Physical examination · Marine Safety Unit Paducah · USCG Heartland District (CGD-H) · Activity 3919466
10 March 2007
Uninspected Other
Physical examination · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 2947527
8 March 2007
Type not recorded
No type recorded · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 2890595
16 February 2007
Deficiency Check
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 2874627
2 February 2007
Uninspected Other
Physical examination · Marine Safety Detachment Peoria · USCG Heartland District (CGD-H) · Activity 2867070
1 February 2007
Type not recorded
No type recorded · Marine Safety Detachment Peoria · USCG Heartland District (CGD-H) · Activity 2867087
1 December 2006
Uninspected Other
Physical examination · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 2836658
1 December 2006
Type not recorded
No type recorded · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 2838883
30 January 2006
Annual Inspection
Physical examination · Marine Safety Detachment Cincinnati · USCG Heartland District (CGD-H) · Activity 2576265
30 January 2006
MTSA Verification
Physical examination · Marine Safety Detachment Cincinnati · USCG Heartland District (CGD-H) · Activity 2576269
18 November 2005
Security Plan Review - ASP
Administrative · Marine Safety Center (MSC) · Activity 2536930
9 October 2000
Type not recorded
No type recorded · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 4648
13 March 2000
Type not recorded
No type recorded · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 163319
25 November 1992
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 20401
10 - Safety of Navigation › N/A - No Subsystem › Bridge Navigation Watch Alarm System (BNWAS)
Issued 6 May 2025
Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Action required: 705 - Other - as specified
Resolved 13 May 2025
Resolution: Inspect installation of Pilot [name withheld], SAT.
02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-corrosion
Issued 29 August 2024
Resolved
An existing vessel may be deemed by the OCMI, or TPO, to
be in compliance with this subpart provided that either:
The vessel has been both in satisfactory service insofar
as structural adequacy is concerned and does not cause
the structure of the vessel to be questioned by either
the OCMI, or TPO engaged to perform an audit or survey.
Marine Inspector observed multiple wasted/holed
structural frames and keel during in-service inspection.
Voids were observed to have several feet of water.
46 CFR 144.200(b)
Condition: Placed in Improper Service
Action required: 30 - Ship detained
Resolved 21 October 2024
Resolution: Received report from ITOW and attended vessel to verify satisfactory structural repairs.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 29 August 2024
Resolved
Electrical equipment and electrical cables must be
suitably protected from wet and corrosive environments.
Inspector observed an unplugged electrical cord hanging
loose in a void filled with several feet of water.
46 CFR 143.400 (f)
Condition: Improper/Lack of Maintenance
Action required: 30 - Ship detained
Resolved 21 October 2024
Resolution: Unplugged extension cord and removed it from void.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 29 August 2024
Resolved
Electrical systems and equipment must function properly
and minimize system failures and fire and shock hazards.
Inspector observed generator windings were entirely
coated with oil and debris.
46 CFR 143.400 (a)
Condition: Improper/Lack of Maintenance
Action required: 30 - Ship detained
Resolved 21 October 2024
Resolution: Both generator end bells opened and cleaned. Records show less than 11k hours on prime mover/main seal, no leaks on seals. Oil came from proximity to crankcase exhauster, vent relocated to prevent future issues.
09 - Working and Living Conditions › 092 - Working Conditions › Machinery
Issued 29 August 2024
Resolved
All seals and gaskets must be properly maintained to
prevent leaks of flammable or combustible liquid, as
those terms are defined in 46 CFR subpart 30.10, into
the machinery space. Inspector observed the port main
diesel engine oil sump drain pipe was dripping oil into
the bilge, hydraulic oil pump was consistently dripping.
46 CFR 143.220(a)
Condition: Improper/Lack of Maintenance
Action required: 30 - Ship detained
Resolved 21 October 2024
Resolution: Port oil pump was replaced. Tested, all sat.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Doors
Issued 29 August 2024
Resolved
All seals and gaskets must be properly maintained to pre
The master must ensure that all hatches, doors, and
other openings designed to be watertight or weathertight
function properly. Inspector observed five
weathertight doors that were not sealed and allowed
light through the frame while closed. Inspector observed
a door underneath the starboard pilot house deck there
was a small door leading to the bridge electronic space.
The door did not fit the opening with approximately a 2
inch gap at the forward end.
46 CFR 140.610 (b)
Condition: Improper/Lack of Maintenance
Action required: 30 - Ship detained
Resolved 21 October 2024
Resolution: Door on third deck under pilot house was extended for full closure.
07 - Fire Safety › N/A - No Subsystem › Ventilation
Issued 29 August 2024
Resolved
Means must be provided for stopping each fan in a
ventilation system serving machinery spaces and for
closing, in case of fire, each doorway, ventilator, and
annular space around funnels and other openings into
such spaces. Inspector observed E/R supply vent closures were bent and unable to completely close. The port supply vent was open on missing a back plate on the vent which regardless of closure would not cut off air supply
46 CFR 144.605
Condition: Improper/Lack of Maintenance
Action required: 30 - Ship detained
Resolved 21 October 2024
Resolution: Installed back plate on port and stbd fire dampers.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 29 August 2024
Resolved
Individual circuit breakers on switchboards and
distribution panels must be labeled with a description
of the loads they serve. Inspector observed multiple
electrical distribution panels unlabeled throughout the
vessel.
46 CFR 143.400 (d)
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 7 October 2024
Resolution: Panels labeled.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 29 August 2024
Resolved
Electrical components that pose an electrical hazard
must be in an enclosure. Inspector observed a light bulb
that had been pulled from the socket. Socket was melted
and not fully intact with not light shade covering the
light.
46 CFR 143.400 (g)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 7 October 2024
Resolution: New light fixture installed, inspected sat.
09 - Working and Living Conditions › 092 - Working Conditions › Machinery
Issued 29 August 2024
Resolved
Pressure vessels over 5 cubic feet in volume and over 15
pounds per square inch maximum allowable working
pressure (MAWP) must be equipped with an indicating
pressure gauge (in a readily visible location) and with
one or more spring-loaded relief valves. The total
relieving capacity of such relief valves must prevent
pressure from exceeding the MAWP, as established by the
manufacturer, by more than 10 percent.
Inspector observed the plate on the pressure vessel was
stamped at 250 MAWP with 265 psi safety relief valves.
46 CFR 143.300(a)
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 6 May 2025
Resolution: Inspected 6 pressure vessel relief valves. New as of 2024, set to 250, for vessels with a MAWP of 250.
09 - Working and Living Conditions › 092 - Working Conditions › Guards - fencing around dangerous machinery parts
Issued 29 August 2024
Resolved
An exposed hazard such as gears and rotating machinery,
must be protected by a cover, guard or rail. This is not
meant to restrict access to towing equipment such as
winches, drums, towing gear or steering compartment
equipment necessary for the operation of the vessel.
Inspector observed lack of machine guard on the lube oil
pump.
46 CFR 144.820
Condition: Placed in Improper Service
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 7 October 2024
Resolution: Guard was placed around rotating machinery on port and stbd pump.
09 - Working and Living Conditions › 092 - Working Conditions › Machinery
Issued 29 August 2024
Resolved
Machinery and electrical systems must be designed and
maintained to provide for safe operation of the towing
vessel and safety of persons onboard under normal and
emergency conditions. Inspector observed that the
steering linkage in the sewage space had significant
corrosion.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 7 October 2024
Resolution: surface rust cleaned and coated.
07 - Fire Safety › N/A - No Subsystem › Maintenance of Fire protection systems
Issued 29 August 2024
Resolved
Existing equipment and installations, of a type not
required, or in excess of that required by this part,
not meeting the applicable requirements of this part may
be continued in service solong as they are in good
condition and accepted by the local OCMI or TPO.
Inspector observed the hydrostatic dates on the two 50lb
CO2 bottles in the E/R were from 2014 which does not meet the OCMI's standard for good condition.
46 CFR 142.215
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 7 October 2024
Resolution: New bottles installed and inspected.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 29 August 2024
Resolved
Except as provided in § 173.17, no person may use a
vessel to which this part applies unless: (1) It has a
number issued on a certificate of number by the issuing
authority in the State of principal operation; and (2)
The number is displayed as described in § 173.27.
Vessel number required. The work boat located on board
had an engine of 25 hp with no registration.
33 CFR 173.15
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 6 May 2025
Resolution: the work boat is no longer on board the vessel.
02 - Structural Conditions › N/A - No Subsystem › Hull damage impairing seaworthiness
Issued 19 April 2024
Resolved
Vessel is actively taking on water. Issued "No Sail" 835 requiring vessel to make appropriate repairs.
Action required: 17 - Rectify deficiencies prior to departure
Due 10 May 2024
Resolved 3 September 2024
Resolution: Issued new CG-835 under activity 7992627.
Engineering › Fuel Oil Storage/Transfer System › Piping
Issued 16 February 2007
Resolved
Properly repair diesel fuel lines for the feed and return piping for the generators.
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Due 17 February 2007
Resolved 17 February 2007
Documentation › Safety/Response Plans/Programs › Vessel Response Plan
Issued 16 February 2007
Resolved
Provide a vessel response plan for the vessel.
Due 16 March 2007
Resolved 3 January 2011
Fire Fighting › Fire Pumps › Pressure
Issued 1 February 2007
Resolved
Ensure the vessel's installed fire pump produces 50 psi @ 80 GPM as per (46 CFR 27.301).
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Due 1 February 2007
Resolved 16 February 2007
Fire Fighting › Fire Pumps › Location
Issued 1 February 2007
Resolved
Ensure the vessel fire pump is aligned to ensure start up and water flow from outside the engine room.
Condition: Design Flaw
Action required: 701 - Prior to carriage of passengers/cargo
Due 1 February 2007
Resolved 20 February 2007
Engineering › Lubricating Oil Service System › Hose
Issued 1 February 2007
Resolved
Replace the leaking oil pressure hose on the port generator.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 1 February 2007
Resolved 16 February 2007
Accommodation/Occupational Safety › Occupational Safety › Tripping/Falling Hazard
Issued 1 February 2007
Resolved
Properly secure the fathometer wire at the top of the forward hold ladder.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 1 February 2007
Resolved 16 February 2007
Engineering › Diesel Engine (auxiliary) › Injector (fuel injection)
Issued 1 February 2007
Resolved
Ensure port generator does not have excessive lube oil dilution.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 1 February 2007
Resolved 16 February 2007
Engineering › Diesel Engine (propulsion-reduction gear) › Piping (exhaust)
Issued 1 February 2007
Resolved
Repair excessive exhaust gas leak on the stbd main, in the vicinity of #8 and #16 cylinders or mitigate leaks until permanent repairs are completed.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 1 February 2007
Resolved 16 February 2007
Operations/Management › Bilge/Bilge System Management › Control of Oil Mixtures
Issued 1 February 2007
Resolved
Remove excessive oil and foreign debris (wood, plastic buckets, bottles and rags…) from the engine room bilge.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 1 February 2007
Resolved 16 February 2007
Engineering › Lubricating Oil Service System › Cooler
Issued 1 February 2007
Resolved
Repair leaks on the port and stbd engine lube oil cooler.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 1 February 2007
Resolved 16 February 2007
Engineering › Reduction Gearing/Clutches › Shaft
Issued 1 February 2007
Resolved
Remove excess grease from under the stbd propeller shaft.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 1 February 2007
Resolved 16 February 2007
Electrical › Electric Generation Source (service) › Generator
Issued 1 February 2007
Resolved
Repair all excessive oil leaks on the port generator.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 1 February 2007
Resolved 16 February 2007
Engineering › Diesel Engine (propulsion-reduction gear) › Bearing
Issued 1 February 2007
Resolved
Repair excessive oil leaks on the port and stbd inboard main engines
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 1 February 2007
Resolved 16 February 2007
Accommodation/Occupational Safety › Occupational Safety › Tripping/Falling Hazard
Issued 1 February 2007
Resolved
Clean all lower engine room oil covered deck plates.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 1 February 2007
Resolved 16 February 2007
Engineering › Diesel Engine (propulsion-reduction gear) › Camshaft
Issued 1 February 2007
Resolved
Properly repair leaking port engine cam gear oil line. (Currently siliconed)
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 1 February 2007
Resolved 16 February 2007
Engineering › Reduction Gearing/Clutches › Bearing
Issued 1 February 2007
Resolved
Properly repair the stbd drive gear, forward, leaking seal and remove cardboard oil sling shields.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 1 February 2007
Resolved 16 February 2007
Engineering › Diesel Engine (propulsion/auxiliary-electric) › Turbocharger
Issued 1 February 2007
Resolved
Make repairs to the stbd engine super charger, (Leaking (oil) end plates).
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 1 February 2007
Resolved 16 February 2007
Construction/Loadline › Structures › Transverse Bulkhead
Issued 1 February 2007
Resolved
Provide proof the forward engine room bulkhead was not designed to be watertight.
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Due 1 February 2007
Resolved 17 February 2007
Resolution: Took off all paint on door gaskets and knife edges. Lubricated all door dogs.
Accommodation/Occupational Safety › Occupational Safety › Tripping/Falling Hazard
Issued 1 February 2007
Resolved
Remove residual oil from the port engine room side void.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 1 February 2007
Resolved 17 February 2007
Accommodation/Occupational Safety › Occupational Safety › Tripping/Falling Hazard
Issued 1 February 2007
Resolved
Remove residual oil from the lower engine room aft void.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 1 February 2007
Resolved 17 February 2007
Fire Fighting › Fixed Fire Detection System › Approval
Issued 1 February 2007
Resolved
Provide proof the installed engine room fire detection system was approve by a Professional Engineer or class society as per (46CFR 27.203(g)).
Due 1 March 2007
Resolved 16 February 2007
Pollution Prevention/Response › Prevention Equipment › Oily Mixture Discharge Fixed Piping System
Issued 1 February 2007
Resolved
Ensure the vessel has a fixed means to discharge oily bilge slop as per (33CFR 155.410).
Due 1 March 2007
Resolved 16 February 2007
Electrical › Electrical Distribution System (emergency) › Wiring
Issued 1 February 2007
Resolved
Cover exposed wires on the installed fire pump.
Due 1 March 2007
Resolved 16 February 2007
Electrical › Lighting (service) › Lighting Feeder
Issued 1 February 2007
Resolved
Repair exposed light wires in the overhead of the sewage space, stbd side.
Due 1 March 2007
Resolved 16 February 2007
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 1 February 2007
Resolved
Install guards on the steering pump shafts.
Condition: Design Flaw
Due 1 March 2007
Resolved 16 February 2007
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 1 February 2007
Resolved
Cover exposed florescent light in the overhead of the parts room.
Condition: Unknown
Due 1 March 2007
Resolved 16 February 2007
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Mounting Bracket
Issued 1 February 2007
Resolved
Properly secure the steering room fire extinguisher.
Due 1 March 2007
Resolved 16 February 2007
Construction/Loadline › Markings › Draft Marks/Indicating System
Issued 1 February 2007
Resolved
Ensure the vessel has the official number permanently installed on an internal structural member.
Due 1 March 2007
Resolved 16 February 2007
Fire Fighting › Nozzles › Type
Issued 1 February 2007
Resolved
Ensure all the fire hose stations have vari-nozzles installed.
Due 1 March 2007
Resolved 16 February 2007
Electrical › Electrical Distribution System (service) › Outlet Box
Issued 1 February 2007
Resolved
Ensure the vessel's fwd hold relay box secures closed.
Due 1 March 2007
Resolved 16 February 2007
Electrical › Lighting (service) › Lighting Fixture
Issued 1 February 2007
Resolved
Install globes on the exposed forward hold, overhead lights.
Due 1 March 2007
Resolved 16 February 2007
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 1 February 2007
Resolved
Install missing guard on the capstan motor exposed gears
Due 1 March 2007
Resolved 16 February 2007
Accommodation/Occupational Safety › Occupational Safety › Tripping/Falling Hazard
Issued 1 February 2007
Resolved
Properly secure the drooping wire in the fwd hold.
Condition: Improper/Lack of Maintenance
Due 1 March 2007
Resolved 16 February 2007
Operations/Management › Bilge/Bilge System Management › Control of Excess Water
Issued 1 February 2007
Resolved
Make repairs to the vessel's installed bilge pump.
Condition: Improper/Lack of Maintenance
Due 1 March 2007
Resolved 16 February 2007
Documentation › Manuals/Policy Documentation › Transfer Procedures
Issued 1 February 2007
Resolved
Ensure transfer procedures comply with the communications portion of 33CFR155.785 and all PIC's are designated in writing as per 33CFR155.700.
Condition: Unknown
Due 1 March 2007
Resolved 16 February 2007
Navigation › Piloting/Steering › Coast Guard Light List
Issued 1 December 2006
Resolved
Coast Guard Light List needs to be updated.
Condition: Improper/Lack of Maintenance
Due 31 December 2006
Resolved 8 December 2006
Resolution: Item was fixed in drydock.
Navigation › Piloting/Steering › Inland Navigation Rules
Issued 1 December 2006
Resolved
Inland Navigation Rules needs to be updated.
Condition: Improper/Lack of Maintenance
Due 31 December 2006
Resolved 8 December 2006
Resolution: Item was fixed in drydock.
Electrical › Lighting (service) › Lighting Fixture
Issued 1 December 2006
Resolved
Exterior lights missing or needs to be replaced.
Condition: Improper/Lack of Maintenance
Due 31 December 2006
Resolved 8 December 2006
Resolution: Item was fixed in drydock.
Fire Fighting › Fixed Fire Detection System › Control Panel
Issued 1 December 2006
Resolved
Fire detection system not working.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 2 December 2006
Resolution: Tech came out to fix the system. report received.
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 1 December 2006
Resolved
Towing lights at stern need to be moved or the safety boat needs to be moved. Bottom stern light being blocked by safety boat.
Condition: Improper Installation
Due 31 December 2006
Resolved 8 December 2006
Resolution: Item was fixed in drydock.
Lifesaving › Visual Distress Signals (General) › Condition
Issued 1 December 2006
Resolved
Ring bouy lights not working.
Condition: Improper/Lack of Maintenance
Due 31 December 2006
Resolved 8 December 2006
Resolution: Item was fixed in drydock.
Engineering › Lubricating Oil Service System › Valve
Issued 1 December 2006
Resolved
Oil cooling system bypass valve leaking.
Condition: Improper/Lack of Maintenance
Due 31 December 2006
Resolved 8 December 2006
Resolution: Item was fixed in drydock.
Electrical › Electrical Distribution System (service) › Outlet Box
Issued 1 December 2006
Resolved
Loose electrical wires in different location throughout the vessel.
Condition: Improper/Lack of Maintenance
Due 31 December 2006
Resolved 8 December 2006
Resolution: Item was fixed in drydock.
Pollution Prevention/Response › Prevention Equipment › Bilge Monitor
Issued 1 December 2006
Resolved
Excessive oil and fuel found in the bilge.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 2 December 2006
Resolution: 11,000 gallons was pumped out of the slop tank, bilge and stern void. receipts received at the unit.
Lifesaving › Lifebuoys › Markings (ship name/port)
Issued 1 December 2006
Resolved
Vessel name on ring bouy needs to be replaced. Name was put on with a marker.
Condition: Improper/Lack of Maintenance
Due 31 December 2006
Resolved 8 December 2006
Resolution: Item was fixed in drydock.
Engineering › Fuel Oil Service System › Valve
Issued 1 December 2006
Resolved
Fuel oil being drained into the bilge.
Condition: Improper/Lack of Maintenance
Due 31 December 2006
Resolved 8 December 2006
Resolution: Item was fixed in drydock.
Construction/Loadline › Structures › Manhole
Issued 1 December 2006
Resolved
Soft patch found in forward hold.
Condition: Improper/Lack of Maintenance
Due 31 December 2006
Resolved 8 December 2006
Resolution: Item was fixed in drydock.
Construction/Loadline › Hull › Hull Plating
Issued 1 December 2006
Resolved
Leak found in stern void.
Condition: Improper/Lack of Maintenance
Due 31 December 2006
Resolved 8 December 2006
Resolution: Item was fixed in drydock.
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Location
Issued 1 December 2006
Resolved
Missing fire extinguisher in engine room.
Condition: Improper/Lack of Maintenance
Due 31 December 2006
Resolved 8 December 2006
Resolution: Item was fixed in drydock.