MAURY USCG vessel records Sign in
← All vessels

J L BRADEN

J L BRADEN is a 2004 towing vessel. The Coast Guard has recorded 19 inspections since 2008, most recently in July 2026, along with 12 deficiencies and 4 casualty investigations between 2008 and 2022.

Records from 2008 to 2026. Most recent: inspection, 8 July 2026.

Built
2004
Last inspected
8 July 2026
Documentation
Valid · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WDI3041
669861
Flag
UNITED STATES
367684360
Maury page id
psix-669861

Inspections, by type

…with no type recorded4
Years with a record 13 calendar years (2008–2026)
The 19 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Towing Vessel class in Maury's sources begin in 1980.

Documentation record

Registered dimensions (L × B × D)50.0 ft × 22.0 ft × 8.0 ft
Registered tonnagegross 73 / net 59
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderSERODINO INC · GUILD, TN, UNITED STATES · built 2004
Hull materialSteel
PropulsionDiesel Direct
Hull shapeBox
Hull configurationMonohull
Hailing portCOVINGTON, KY
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 23 October 2025 · expires 31 October 2026
Service, as the file records itTowing Vessel
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it73 - Simplified, Gross Ton
59 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

WDI3041MMSI 367684360 · active · compulsorily equipped · granted 10 June 2025, expires 17 July 2035 · licensed under a name not among this hull’s recorded names (not shown)
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspected as a tow unit · 8

Inspection history · 19

8 July 2026 Annual Inspection · Deficiency Check
Physical examination · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 8395756
24 June 2025 Annual Inspection
Physical examination · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 8147027
20 June 2024 Examination of Repairs · Hull Examination · COI Inspection
Physical examination · Marine Safety Detachment Cincinnati · USCG Heartland District (CGD-H) · Activity 7938482
18 May 2023 Annual Inspection · Deficiency Check
Physical examination · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 7675144
17 May 2022 Deficiency Check · Annual Inspection
Physical examination · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 7433825
9 March 2022 Deficiency Check
Physical examination · Marine Safety Detachment Cincinnati · USCG Heartland District (CGD-H) · Activity 7410155
17 February 2022 In-Service Inspection · Administrative Inspection
Physical examination · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 7397826
16 February 2022 Type not recorded
No type recorded · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 7398434
17 June 2021 Annual Inspection · MTSA Verification · Deficiency Check
Physical examination · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 7232818
25 June 2020 Annual Inspection
Physical examination · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 6966911
27 June 2019 Initial Certification · Administrative Inspection
Physical examination · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 6699589
18 October 2017 Type not recorded
No type recorded · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 6291730
28 February 2017 Industry Initiated Exam
Physical examination · Marine Safety Detachment Cincinnati · USCG Heartland District (CGD-H) · Activity 6098403
21 October 2013 Industry Initiated Exam · Deficiency Check · MTSA Verification
Physical examination · Marine Safety Detachment Cincinnati · USCG Heartland District (CGD-H) · Activity 4736198
7 April 2010 Deficiency Check
Physical examination · Marine Safety Detachment Cincinnati · USCG Heartland District (CGD-H) · Activity 3711235
4 March 2010 Administrative Inspection
Administrative · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3690019
2 March 2010 Industry Initiated Exam
Physical examination · Marine Safety Detachment Cincinnati · USCG Heartland District (CGD-H) · Activity 3689364
25 September 2009 Type not recorded
No type recorded · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 3605187
6 July 2008 Type not recorded
No type recorded · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 3260358

Deficiency record · 12

03 - Water/Weathertight Conditions › N/A - No Subsystem › Manholes/flush scuttles
Issued 8 July 2026 Resolved
All towing vessels must be operated in a manner that minimizes the risk of down-flooding and progressive flooding. The master must ensure that all hatches, doors, and other openings designed to be watertight or weather-tight function properly. MI observed that the forward void hatch gasket was damaged allowing water ingress. 46 CFR 140.610
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 July 2026
Resolved 17 July 2026
Resolution: Received photographic evidence of new gaskets installed.
09 - Working and Living Conditions › 091 - Living Conditions › Sanitary Facilities
Issued 8 July 2026 Resolved
Each Marine Sanitation device must be free of design defects such as rough or sharp edges that may cause bodily injuries or that would allow toxic substances to escape to the interior of the vessel. MI observed that the MSD was leaking. 33 CFR 159.95(a)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 July 2026
Resolved 17 July 2026
Resolution: Received photographic evidence of repairs.
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 18 May 2023 Resolved
Vessels fire hose closure valve was found with crack and leaking water. Valve was replaced.
Condition: Damaged By Earlier Event
Action required: 10 - Deficiency Rectified
Due 18 May 2023
Resolved 18 May 2023
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 17 May 2022 Resolved
Port Ring Life Buoy (RLB) Retro-reflective material was wasted, repair or replace RLB.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 17 June 2022
Resolved 19 May 2022
02 - Structural Conditions › N/A - No Subsystem › Steering gear
Issued 17 May 2022 Resolved
Hydraulic hoses on flanking rudder system were rubbing against each aother causing wear to hose. Verify integrity of hoses and install appropriate chafing gear.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 17 June 2022
Resolved 19 May 2022
09 - Working and Living Conditions › 092 - Working Conditions › Cleanliness of engine room
Issued 17 May 2022 Resolved
Vessel had emulsified oil in engine room bilge. Clean oil out of bilges.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 17 June 2022
Resolved 20 May 2022
02 - Structural Conditions › N/A - No Subsystem › Steering gear
Issued 17 February 2022 Resolved
Machinery and electrical systems must be designed and maintained to provide for safe operation of the towing vessel and safety of persons onboard under normal and emergency conditions. The vessel reported an issue with the vessel's starboard rudder. Prove proper operation of the vessel's steering system.
Condition: Damaged By Earlier Event
Action required: 17 - Rectify deficiencies prior to departure
Due 17 February 2022
Resolved 9 March 2022
Resolution: MI got vessel underways inspected steering system with satisfactory results.
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 17 June 2021 Resolved
Vessel shall be free of fire hazards. Oil soaked exhaust lagging and oil soaked cables were found in the engine room overhead.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 17 June 2021
Resolved 15 July 2021
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 17 June 2021 Resolved
Float light on port side pilothouse ring buoy was not operable.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 17 July 2021
Resolved 15 July 2021
Resolution: replaced light
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 17 June 2021 Resolved
Float light on starboard side pilothouse ring buoy was not operation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 17 July 2021
Resolved 15 July 2021
Resolution: Replaced battery
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 17 June 2021 Resolved
Lifejackets stowed on the overhead on the 2nd deck were hard to removed from stawage locatin. Stow in a way that makes them readily accessibkle.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 16 July 2021
Resolved 15 July 2021
Resolution: Increased the distance from the ceiling to the bottom of life jacket rack to allow easy removal.
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 17 June 2021 Resolved
Small first aid box on bathroom door had expired materials in it. remove or replace with no expired materials.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 17 July 2021
Resolved 15 July 2021
Resolution: Installed new first aid kit.

Casualty record · 4

6 July 2008Routine · role: Sighted in Area · activity 3260358
25 September 2009Routine · role: Sighted in Area · activity 3605187
18 October 2017Routine · role: Sighted in Area · activity 6291730
16 February 2022Routine · role: Involved in a Marine Casualty · activity 7398434
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.