Records from 2008 to 2026. Most recent: inspection, 8 July 2026.
Documentation record
Registered dimensions (L × B × D)50.0 ft × 22.0 ft × 8.0 ft
Registered tonnagegross 73 / net 59
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderSERODINO INC · GUILD, TN, UNITED STATES · built 2004
Hull materialSteel
PropulsionDiesel Direct
Hull shapeBox
Hull configurationMonohull
Hailing portCOVINGTON, KY
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 23 October 2025 · expires 31 October 2026
Service, as the file records itTowing Vessel
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it73 - Simplified, Gross Ton
59 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Inspection history · 19
8 July 2026
Annual Inspection · Deficiency Check
Physical examination · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 8395756
24 June 2025
Annual Inspection
Physical examination · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 8147027
20 June 2024
Examination of Repairs · Hull Examination · COI Inspection
Physical examination · Marine Safety Detachment Cincinnati · USCG Heartland District (CGD-H) · Activity 7938482
18 May 2023
Annual Inspection · Deficiency Check
Physical examination · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 7675144
17 May 2022
Deficiency Check · Annual Inspection
Physical examination · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 7433825
9 March 2022
Deficiency Check
Physical examination · Marine Safety Detachment Cincinnati · USCG Heartland District (CGD-H) · Activity 7410155
17 February 2022
In-Service Inspection · Administrative Inspection
Physical examination · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 7397826
16 February 2022
Type not recorded
No type recorded · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 7398434
17 June 2021
Annual Inspection · MTSA Verification · Deficiency Check
Physical examination · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 7232818
25 June 2020
Annual Inspection
Physical examination · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 6966911
27 June 2019
Initial Certification · Administrative Inspection
Physical examination · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 6699589
18 October 2017
Type not recorded
No type recorded · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 6291730
28 February 2017
Industry Initiated Exam
Physical examination · Marine Safety Detachment Cincinnati · USCG Heartland District (CGD-H) · Activity 6098403
21 October 2013
Industry Initiated Exam · Deficiency Check · MTSA Verification
Physical examination · Marine Safety Detachment Cincinnati · USCG Heartland District (CGD-H) · Activity 4736198
7 April 2010
Deficiency Check
Physical examination · Marine Safety Detachment Cincinnati · USCG Heartland District (CGD-H) · Activity 3711235
4 March 2010
Administrative Inspection
Administrative · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3690019
2 March 2010
Industry Initiated Exam
Physical examination · Marine Safety Detachment Cincinnati · USCG Heartland District (CGD-H) · Activity 3689364
25 September 2009
Type not recorded
No type recorded · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 3605187
6 July 2008
Type not recorded
No type recorded · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 3260358
03 - Water/Weathertight Conditions › N/A - No Subsystem › Manholes/flush scuttles
Issued 8 July 2026
Resolved
All towing vessels must be operated in a manner that minimizes the risk of down-flooding and progressive flooding. The master must ensure that all hatches, doors, and other openings designed to be watertight or weather-tight function properly. MI observed that the forward void hatch gasket was damaged allowing water ingress.
46 CFR 140.610
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 July 2026
Resolved 17 July 2026
Resolution: Received photographic evidence of new gaskets installed.
09 - Working and Living Conditions › 091 - Living Conditions › Sanitary Facilities
Issued 8 July 2026
Resolved
Each Marine Sanitation device must be free of design defects such as rough or sharp edges that may cause bodily injuries or that would allow toxic substances to escape to the interior of the vessel. MI observed that the MSD was leaking.
33 CFR 159.95(a)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 July 2026
Resolved 17 July 2026
Resolution: Received photographic evidence of repairs.
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 18 May 2023
Resolved
Vessels fire hose closure valve was found with crack and leaking water. Valve was replaced.
Condition: Damaged By Earlier Event
Action required: 10 - Deficiency Rectified
Due 18 May 2023
Resolved 18 May 2023
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 17 May 2022
Resolved
Port Ring Life Buoy (RLB) Retro-reflective material was wasted, repair or replace RLB.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 17 June 2022
Resolved 19 May 2022
02 - Structural Conditions › N/A - No Subsystem › Steering gear
Issued 17 May 2022
Resolved
Hydraulic hoses on flanking rudder system were rubbing against each aother causing wear to hose. Verify integrity of hoses and install appropriate chafing gear.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 17 June 2022
Resolved 19 May 2022
09 - Working and Living Conditions › 092 - Working Conditions › Cleanliness of engine room
Issued 17 May 2022
Resolved
Vessel had emulsified oil in engine room bilge. Clean oil out of bilges.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 17 June 2022
Resolved 20 May 2022
02 - Structural Conditions › N/A - No Subsystem › Steering gear
Issued 17 February 2022
Resolved
Machinery and electrical systems must be designed and maintained to provide for safe operation of the towing vessel and safety of persons onboard under normal and emergency conditions.
The vessel reported an issue with the vessel's starboard rudder. Prove proper operation of the vessel's steering system.
Condition: Damaged By Earlier Event
Action required: 17 - Rectify deficiencies prior to departure
Due 17 February 2022
Resolved 9 March 2022
Resolution: MI got vessel underways inspected steering system with satisfactory results.
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 17 June 2021
Resolved
Vessel shall be free of fire hazards. Oil soaked exhaust lagging and oil soaked cables were found in the engine room overhead.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 17 June 2021
Resolved 15 July 2021
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 17 June 2021
Resolved
Float light on port side pilothouse ring buoy was not operable.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 17 July 2021
Resolved 15 July 2021
Resolution: replaced light
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 17 June 2021
Resolved
Float light on starboard side pilothouse ring buoy was not operation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 17 July 2021
Resolved 15 July 2021
Resolution: Replaced battery
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 17 June 2021
Resolved
Lifejackets stowed on the overhead on the 2nd deck were hard to removed from stawage locatin. Stow in a way that makes them readily accessibkle.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 16 July 2021
Resolved 15 July 2021
Resolution: Increased the distance from the ceiling to the bottom of life jacket rack to allow easy removal.
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 17 June 2021
Resolved
Small first aid box on bathroom door had expired materials in it. remove or replace with no expired materials.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 17 July 2021
Resolved 15 July 2021
Resolution: Installed new first aid kit.