MAURY USCG vessel records Sign in
← All vessels

FRIGHT

FRIGHT is a 1951 towing vessel. The Coast Guard has recorded 13 inspections since 1992, most recently in June 2002, along with 43 deficiencies.

Records from 1992 to 2002. Most recent: inspection, 24 June 2002.

Built
1951
Last inspected
24 June 2002
Documentation
No Operation - PM · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WD8142
Flag
UNITED STATES
366726190 (licence lapsed)
Maury page id
psix-68051

Inspections, by type

…with no type recorded7
Years with a record 8 calendar years (1992–2002)
The 13 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 24 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Towing Vessel class in Maury's sources begin in 1980.

Documentation record

Registered dimensions (L × B × D)83.3 ft × 23.7 ft × 9.9 ft
Registered tonnagegross 145 / net 7
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderLEVINGSTON SHIPBUILDING · ORANGE, TX, UNITED STATES · built 1951
Hull materialSteel
PropulsionDiesel Electric
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portSTATEN ISLAND, NY
Trade endorsementsCoastwise, unrestricted
DocumentationNo Operation - PM · issued 27 March 2002 · expires 28 February 2003
Service, as the file records itTowing Vessel
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it145 - Regulatory (Subpart C or D), Gross Ton
7 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

WCW9232MMSI 366726190 · expired · compulsorily equipped · granted 29 October 1996, cancelled 30 December 2006
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspected as a tow unit · 6

Inspection history · 13

24 June 2002 Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1635590
11 May 2001 Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1064414
31 January 2001 Damage Survey
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1433778
9 June 2000 Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 5596
20 April 1999 Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1376841
20 April 1999 Type not recorded
No type recorded · USCGC HAWSER (WYTL 65610) · USCG Northeast District (CGD-NE) · Activity 1505822
3 March 1999 Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1388763
21 May 1998 Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1128898
22 December 1997 Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 784167
14 October 1997 MARPOL Annex V Examination · Uninspected Towing Vessel
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 779921
25 August 1997 Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 89672
30 November 1993 Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 107969
20 December 1992 Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 106350

Deficiency record · 43

Documentation
Issued 31 January 2001 Resolved
SUBMITT CG-2692 FOR COLLISION TO PORT SIDE.
Condition: Unknown
Due 31 January 2001
Resolved 31 January 2001
Electrical › Electric Supply System (service) › Battery Installation
Issued 31 January 2001 Resolved
PROVIDE COVER FOR BATTERY BOXES.
Condition: Unknown
Due 28 February 2001
Resolved 17 November 2004
Resolution: Cleared by adminstrative action.
Construction/Loadline
Issued 31 January 2001 Resolved
REPAIR HOLES IN HULL/MAIN DECK IWO WASTED STUFFING TUBE RISERS ON THE STERN, UNDER THE STEERING FLAT AND VARIOUS ACCESSES TO LOWER COMPARTMENTS.
Condition: Unknown
Due 31 January 2001
Resolved 31 January 2001
Electrical › Electric Generation Source (service) › Panelboard
Issued 31 January 2001 Resolved
REPLACE MISSING ELECTRICAL BLANKS ON DISTRIBUSION PANEL IN ENG ROOM.
Condition: Unknown
Due 28 February 2001
Resolved 17 November 2004
Resolution: Cleared by adminstrative action.
Documentation
Issued 31 January 2001 Resolved
PROVIDE COPY OF FCC SAFETY RADIO CERTIFICATE.
Condition: Unknown
Due 31 January 2001
Resolved 31 January 2001
Engineering › Diesel Engine (auxiliary) › Air-flex Clutch
Issued 31 January 2001 Resolved
REPAIR/REPLACE RAW WATER INTAKE ON MAIN DIESEL ENGINE.
Condition: Unknown
Due 28 February 2001
Resolved 17 November 2004
Resolution: Cleared by adminstrative action.
Navigation
Issued 31 January 2001 Resolved
PROVE PROPER OPERATION OF VHF-FM RADIO.
Condition: Unknown
Due 31 January 2001
Resolved 31 January 2001
Construction/Loadline › Structures › Scuttle
Issued 31 January 2001 Resolved
REPAIR/REPLACE STATEROOM HATCH COVERS TO OPERATE PROPERLY.
Condition: Unknown
Due 28 February 2001
Resolved 17 November 2004
Resolution: Cleared by adminstrative action.
Accommodation/Occupational Safety › Potable Water System › General
Issued 31 January 2001 Resolved
MAKE DRINKING WATER POTABLE OR REMOVE.
Condition: Unknown
Due 28 February 2001
Resolved 17 November 2004
Resolution: Cleared by adminstrative action.
Electrical › Electric Generation Source (emergency) › Generator
Issued 31 January 2001 Resolved
REPAIR/REPLACE EXHAUST LEAK ON GENERATOR.
Condition: Unknown
Due 28 February 2001
Resolved 17 November 2004
Resolution: Cleared by adminstrative action.
Accommodation/Occupational Safety
Issued 31 January 2001 Resolved
REPAIR/REPLACE GALLEY GAS OIL FIRED SUPPLY LINE IWO EMERGENCY SHUTOFF.
Condition: Unknown
Due 31 January 2001
Resolved 31 January 2001
Engineering
Issued 31 January 2001 Resolved
REPAIR/REPLACE FUEL TANK VENT RISERS.
Condition: Unknown
Due 31 January 2001
Resolved 31 January 2001
Construction/Loadline
Issued 31 January 2001 Resolved
REPAIR/REPLACE ALL MAIN DECK WATER TIGHT DOOR COMBINGS.
Condition: Unknown
Due 31 January 2001
Resolved 31 January 2001
Construction/Loadline
Issued 31 January 2001 Resolved
REMOVE OIL AND WATER IN BILGE.
Condition: Unknown
Due 31 January 2001
Resolved 31 January 2001
Engineering
Issued 31 January 2001 Resolved
REPAIR LEAKING SHAFT SEAL.
Condition: Unknown
Due 31 January 2001
Resolved 31 January 2001
Electrical
Issued 31 January 2001 Resolved
REPAIR OR REPLACE OPEN LIVE LIGHTING FIXTURES THROUGHOUT VESSEL.
Condition: Unknown
Due 31 January 2001
Resolved 31 January 2001
Construction/Loadline
Issued 31 January 2001 Resolved
REPAIR HOLES IN SUPERSTRUCTURE IWO GALLEY (BOTH SIDES).
Condition: Unknown
Due 31 January 2001
Resolved 31 January 2001
Construction/Loadline
Issued 31 January 2001 Resolved
REPLACE PORTLIGHTS WITH BULLET HOLES IN WATER TIGHT DOOR ON MESSDECK STBD SIDE.
Condition: Unknown
Due 31 January 2001
Resolved 31 January 2001
Lifesaving
Issued 31 January 2001 Resolved
SECURE PROPANE TANK ON SECOND DECK.
Condition: Unknown
Due 31 January 2001
Resolved 31 January 2001
Accommodation/Occupational Safety
Issued 31 January 2001 Resolved
REPAIR/REPLACE PORT SAFETY LADDER TO UPPER DECK.
Condition: Unknown
Due 31 January 2001
Resolved 31 January 2001
Accommodation/Occupational Safety
Issued 31 January 2001 Resolved
REPAIR/REPLACE DECK GRATING IN UPPER ENG ROOM.
Condition: Unknown
Due 31 January 2001
Resolved 31 January 2001
Accommodation/Occupational Safety › Occupational Safety › Hand Grab
Issued 31 January 2001 Resolved
REPAIR/REPLACE ENTIRE SAFETY RAIL ON UPPER DECK PORT SIDE.
Condition: Unknown
Due 17 November 2004
Resolved 17 November 2004
Resolution: Cleared by adminstrative action.
Electrical
Issued 31 January 2001 Resolved
PROPERLY TERMINATE OR REPLACE HIGH VOLTAGE DC AND AC CABLES THROUGHOUT THE VESSEL.
Condition: Unknown
Due 31 January 2001
Resolved 31 January 2001
Lifesaving
Issued 31 January 2001 Resolved
REPLAIR OR REPLACE WASTED DECK GRATING IN UPPER DECK ENG ROOM STBD SIDE COVERED BY MATTING.
Condition: Unknown
Due 31 January 2001
Resolved 31 January 2001
Electrical
Issued 31 January 2001 Resolved
REPAIR/REPLACE SHORT THAT EXISTED IN ORGINAL WIRING OF VSL, FIRE IN SEVERALOF THE COMPARTMENTS HAD TAKEN PLACE. REMOVE WIRING REPLACED BY UNAUTHORIZEDHOUSEHOLD EXTENSION CORD TIED INTO MAIN AC SYSTEM.
Condition: Unknown
Due 31 January 2001
Resolved 31 January 2001
Navigation
Issued 31 January 2001 Resolved
REPAIR OR REPLACE VSL MAST NAVIGATION LIGHTS TO SHOW PROPER CHARACTERISITCS.
Condition: Unknown
Due 31 January 2001
Resolved 31 January 2001
Lifesaving
Issued 31 January 2001 Resolved
PROVIDE PROOF OF LIFERAFT SERVICING, MAKE FLOAT FREE AND INSTALL A WEAK LEAK.
Condition: Unknown
Due 31 January 2001
Resolved 31 January 2001
Navigation
Issued 31 January 2001 Resolved
REPAIR SIDELIGHT NAVIGATION SCREENS TO SHOW THE PROPER CHARACTERISTCS.
Condition: Unknown
Due 31 January 2001
Resolved 31 January 2001
Electrical
Issued 31 January 2001 Resolved
REPAIR/REPLACE UPPER DECK STEERING FLAT CONTROL BOX.
Condition: Unknown
Due 31 January 2001
Resolved 31 January 2001
Navigation
Issued 22 December 1997 Resolved
PAROVIDE AND INSTALL RESTRICTED MANENUVERABILITY LIGHTS ON THE VESSEL.
Condition: Unknown
Due 22 December 1997
Resolved 22 December 1997
Fire Fighting
Issued 14 October 1997 Resolved
PROVIDE SERVICING TO ALL PORTABLE FIRE/AND FIXED SYSTEMS AS NEEDED.
Condition: Unknown
Due 14 October 1997
Resolved 14 October 1997
Accommodation/Occupational Safety
Issued 14 October 1997 Resolved
PROVIDE PROOF A GARBAGE RECORD IS BEING KEPT ON BOARD THE VESSEL.
Condition: Unknown
Due 14 October 1997
Resolved 14 October 1997
Accommodation/Occupational Safety
Issued 14 October 1997 Resolved
PROVIDE AND POST A COPY OF THE COMPANIES DRUG AND ALCOHOL POLICY, WITH PHONE NUMBERS INCLUDED.
Condition: Unknown
Due 14 October 1997
Resolved 14 October 1997
Accommodation/Occupational Safety
Issued 14 October 1997 Resolved
PROVIDE AND POST A COPY OF THE VESSEL'S WASTE MANAGEMENT PLAN.
Condition: Unknown
Due 14 October 1997
Resolved 14 October 1997
Accommodation/Occupational Safety
Issued 14 October 1997 Resolved
MAKE MSD HOLDING TANK AVAILABLE FOR VISUAL EXAMINATION.
Condition: Unknown
Due 14 October 1997
Resolved 14 October 1997
Navigation
Issued 14 October 1997 Resolved
PROVIDE A OPERATIONAL TEST OF ALL NAVIGATIONAL LIGHTS
Condition: Unknown
Due 14 October 1997
Resolved 14 October 1997
Navigation
Issued 14 October 1997 Resolved
PROVLIDE THE VESSEL WITH COPIES OF ALL NAVIGATIONAL PUBLICATIONS AS REQUIRED, CG LIGHT LIST, TIDAL AND CURRENT TABLES, U.S. COAST PILOT AND NAV.RULES.
Condition: Unknown
Due 14 October 1997
Resolved 14 October 1997
Lifesaving
Issued 14 October 1997 Resolved
PROVIDE THE VESSEL WITH (3) 20"ORANGE RING BUOYS AND WATER LIGHTS.
Condition: Unknown
Due 14 October 1997
Resolved 14 October 1997
Lifesaving
Issued 14 October 1997 Resolved
PROVIDE ALL CREW WITH PFD'S OR IMMERSION SUITS, WITH LIGHTS, VSL./OWNER NAME MARKED OR STENCILED ON THEM.
Condition: Unknown
Due 14 October 1997
Resolved 14 October 1997
Navigation
Issued 14 October 1997 Resolved
PROVIDE PROOF NAVIGATIONAL CHARTS ARE CORRECTED OR PROVIDE THE VESSEL WITH NEW CHARTS FOR ALL AREAS THE VESSEL TRANSITS.
Condition: Unknown
Due 14 October 1997
Resolved 14 October 1997
Engineering
Issued 14 October 1997 Resolved
PROVIDE A LINE DRAWING OF VESSEL'S FUEL OIL SYSTEM IN CONJUNCTION WITH THE FUEL OIL PROCEDURES.
Condition: Unknown
Due 14 October 1997
Resolved 14 October 1997
Documentation
Issued 14 October 1997 Resolved
PROVIDE PROOF OF ALL LICENSED AND OR MMD CARD CARRYING PERSONNEL.
Condition: Unknown
Due 14 October 1997
Resolved 14 October 1997
Documentation
Issued 14 October 1997 Resolved
PROVIDE PROOF THAT THE MASTER AND MATE HOLD A VALID RADIO OPERATOR'S PERMIT.
Condition: Unknown
Due 14 October 1997
Resolved 14 October 1997

Ownership record