Records from 1993 to 2024. Most recent: inspection, 23 December 2024.
Inspection history · 44
23 December 2024
Deficiency Check · Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 8050298
4 June 2024
Drydock Exam · Deficiency Check · Internal Structural Exam · Administrative Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7926911
30 November 2023
Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7831731
1 February 2023
Administrative Inspection
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 7630584
20 December 2022
Administrative Inspection
Administrative · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7611313
7 December 2022
Annual Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7604881
5 April 2022
Damage Survey · Examination of Repairs
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 7425020
25 February 2021
Administrative Inspection · COI Inspection · Initial Certification
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7146753
28 March 2019
Type not recorded
No type recorded · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6651318
11 October 2018
Administrative Inspection
Administrative · Navigation Center · Activity 6558996
30 May 2017
Industry Initiated Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6159786
6 November 2016
Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 6036576
20 August 2014
Administration
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 4960650
15 April 2014
Deficiency Check
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 4851973
10 February 2014
Industry Initiated Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 4797139
17 November 2013
Type not recorded
No type recorded · Sector Delaware Bay · USCG East District (CGD-E) · Activity 4755054
8 January 2013
Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 4512982
18 October 2012
Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 4496714
15 February 2012
Administration
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 4245001
8 March 2007
Type not recorded
No type recorded · USCG Northeast District (dp) · USCG Northeast District (CGD-NE) · Activity 2884027
23 February 2006
Uninspected Other · MTSA/ISPS Verification
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 2597570
6 January 2006
Security Plan Amendment Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2562167
20 December 2005
Security Plan Amendment Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2554219
30 August 2005
Security Plan Amendment Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2479313
17 June 2005
MTSA Verification · Uninspected Other
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 2393459
16 June 2005
Type not recorded
No type recorded · USCGC MORRO BAY (WTGB 106) · USCG Great Lakes District (CGD-GL) · Activity 2423766
27 May 2005
Security Plan Amendment Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2369864
20 April 2005
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 2338688
30 January 2004
Security Plan Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 1998753
7 February 2003
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1741274
7 February 2003
Damage Survey
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1742844
13 May 2002
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1616383
1 February 2002
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1483977
26 October 2001
Type not recorded
No type recorded · USCGC BAINBRIDGE ISLAND (WPB 1343) · USCG Northeast District (CGD-NE) · Activity 1496711
15 June 2001
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 35879
20 December 2000
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 11735
16 December 1999
Type not recorded
No type recorded · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 16060
13 January 1998
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1616
5 January 1998
Type not recorded
No type recorded · COTP NEW YORK · USCG Northeast District (CGD-NE) · Activity 654758
5 January 1998
Type not recorded
No type recorded · COTP NEW YORK · USCG Northeast District (CGD-NE) · Activity 654759
16 December 1997
Type not recorded
No type recorded · COTP NEW YORK · USCG Northeast District (CGD-NE) · Activity 85766
3 December 1997
MARPOL Annex V Examination · Uninspected Towing Vessel
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 776683
25 August 1997
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 89672
3 May 1993
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 53750
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 23 December 2024
Resolved
Vessel rep contacted this office to schedule an Annual inspection almost 3 weeks after the 180 day window to conduct an Annual inspection. (Issued 18DEC24) Required vessel to conduct Annual prior to returning to commercial service. (Cleared 23DEC24)
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 23 December 2024
Resolved 23 December 2024
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 23 December 2024
Resolved
Fire detection panel was in fault as the detector in the galley while testing failed. Rep ordered new and will contact CG to clear.
Condition: Damaged By Earlier Event
Action required: 17 - Rectify deficiencies prior to departure
Due 23 December 2024
Resolved 24 December 2024
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 23 December 2024
Resolved
4 Racor fuel filters at the base of the ER ladder where missing flame impingement bowls. Required rep to install new.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 23 December 2024
Resolved 24 December 2024
02 - Structural Conditions › N/A - No Subsystem › Hull damage impairing seaworthiness
Issued 4 June 2024
Resolved
Crop and renew 02 sharp insets on the STBD side hull, amidships near chine.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 20 June 2024
Resolution: Prior to credit drydock. xxxx cropped and renewed with steel inserts xxxx
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 30 November 2023
Resolved
Propulsion machinery shall be suitable in type and design for propulsion requirements of the hull in which it is installed and capable of operating at constant marine load under such requirements without exceeding its designed limitations. Missing stbd fwd engine mounting bracket missing nut. Replace nut.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 5 December 2023
07 - Fire Safety › N/A - No Subsystem › Remote Means of control (opening,pumps,ventilation,etc.) Machinery spaces
Issued 7 December 2022
Resolved
Emergency fuel shut-off valve did not fully close when operated from the aft deck. Ensure valve fully closes when operating remotely.
The valve must be operable from a safe place outside the space where the valve is installed.
46 CFR 143.260(d)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 21 December 2022
Resolved 14 December 2022
Resolution: Provided evidence of fully operational remote fuel shut-offs.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 7 December 2022
Resolved
Dead end wiring discovered on starboard engine. Either remove or place in approprate junction box.
Electrical systems and equipment must function properly and minimize systems failures and fire and shock hazards.
46 CFR 143.400(a)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 21 December 2022
Resolved 14 December 2022
Resolution: Provided photo evidence of dead end wire rectification
03 - Water/Weathertight Conditions › N/A - No Subsystem › Doors
Issued 25 February 2021
Resolved
The master must ensure that all hatches, doors, and other openings designed to be watertight or weather-tight function properly. The watertight door located center aft leading to the engine room did not close properly and daylight was observed at the bottom of the door when closed.
46 CFR 140.610(b)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 1 October 2021
Resolved 23 September 2021
08 - Alarms › N/A - No Subsystem › Engineers' alarm
Issued 25 February 2021
Resolved
Each towing vessel must have a reliable means to provide notification when an emergency condition exists or an essential system develops problems that require attention. Alarms must be visible and audible at each operating station. Vessel missing general, bilge, and required engineer alarms in the upper wheelhouse.
46 CFR 143.230(a),(b)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 1 October 2021
Resolved 18 November 2021
Resolution: Received confirmation email that the supply chain issues are causing a delay in shipment of gauge, and that delivery is set for 12/6/21. Considering deficiency cleared as vessel will install upon arrival.
11 - Life Saving Appliances › N/A - No Subsystem › Line-throwing appliance
Issued 25 February 2021
Resolved
Four rocket projectiles, each complete with bridle and leader of fire-resistant materials. Two of the projectiles shall be of the buoyant type. Not less than 4 primer-ejector cartridges which fit the chamber of the pistol, gun, or launcher. Vessel did not have require amount of line throwing appliances onboard. Observed vessel with one line throwing appliance with one spare charge.
46 CFR 160.040-4(a),(b)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 1 October 2021
Resolved 23 September 2021
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 25 February 2021
Resolved
Electrical conductors passing though watertight bulkheads must be installed so that the bulkhead remains watertight. Vessel failed to provide a means to prevent water intrusion wires passing through the aft fantail bulkhead leading to the engine room and wires passing through the bridge to the weather deck.
46 CFR 143.400(h)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 1 October 2021
Resolved 23 September 2021
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 25 February 2021
Resolved
Electrical components that pose an electrical hazard must be in an enclosure. Observed spliced wires connected with wire nut outside of enclosure on the public announcement speaker.
46 CFR 143.400(g)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 1 October 2021
Resolved 23 September 2021
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 25 February 2021
Resolved
Individual circuit breakers on switchboards and distribution panels must be labeled with a description of the loads they serve. Observed mislabeled breaker panel within the engine room.
46 CFR 143.400(d)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 1 October 2021
Resolved 23 September 2021
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 25 February 2021
Resolved
Fire-detection and fixed fire-extinguishing, in accordance with §142.240 must be recorded in the TVR, official logbook, or in accordance with the TSMS applicable to the vessel. Vessel did not log required maintenance tests as required.
46 CFR 140.915(a)(10)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 1 October 2021
Resolved 23 September 2021
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 25 February 2021
Resolved
For vessels other than those covered in paragraphs (b) and (c) of this section, the name of the vessel must be marked on some clearly visible exterior part of the port and starboard bow and the stern of the vessel. The hailing port of the vessel must be marked on some clearly visible exterior part of the stern of the vessel. Vessel did not have name marked on the port or starboard bow, or stern.
46 CFR 67.123(a)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 1 October 2021
Resolved 23 September 2021
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 25 February 2021
Resolved
Each towing vessel must perform the applicable tests in Table 143.245(b) of this section. The tests required by this section must be recorded in accordance with part 140 of this subchapter. Vessel failed to record required entries in any logbook.
46 CFR 143.245(B)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 1 October 2021
Resolved 23 September 2021
10 - Safety of Navigation › N/A - No Subsystem › Automatic Identification System (AIS)
Issued 11 October 2018
Resolved
Vsl is broadcasting invalid MMSI, Vsl is broadcasting Invalid Call Sign, Vsl is broadcasting Measure length in FT (Vsl dimension Must be measured in meters) and Vsl is not broadcasting an AIS Ship Type
Condition: Invalid
Action required: 705 - Other - as specified
Resolved 1 September 2021
Resolution: cleared on inspection
Fire Fighting › Fixed Gas Fire Extinguishing System › Tanks
Issued 23 February 2006
Resolved
no fire suppression system in engine room.
Condition: Improper Installation
Action required: 705 - Other - as specified
Resolved 16 March 2006
Resolution: Attended vessel at Red Hook Pier 10, Brooklyn NY on 16MAR06. Found vessel to be in full compliance with a B-V semi portable installed and as of 16MAR06 this def is cleared.
Navigation › Piloting/Steering › Marine Charts
Issued 7 February 2003
Resolved
Missing current charts for area transiting.
Condition: Unknown
Due 7 March 2003
Resolved 10 March 2003
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 7 February 2003
Resolved
Guards missing on MDE and generators vibration dampeners and shaft output.
Due 7 March 2003
Resolved 10 March 2003
Electrical › Electrical Distribution System (service)
Issued 7 February 2003
Resolved
Battery box not properly secured to deck for stbd generator.
Condition: Improper Installation
Due 7 March 2003
Resolved 10 March 2003
Construction/Loadline › Structures
Issued 7 February 2003
Resolved
Repair cracked port window in wheelhouse.
Condition: Improper/Lack of Maintenance
Due 7 March 2003
Resolved 10 March 2003
Communications › Audible Communications › Bell
Issued 7 February 2003
Resolved
Vsl missing ships bell
Due 7 March 2003
Resolved 10 March 2003
Electrical › Electrical Distribution System (service) › Cable
Issued 7 February 2003
Resolved
Remove or properly terminate all dead ended wires in in wheelhouse.
Condition: Improper Installation
Due 7 March 2003
Resolved 10 March 2003
Electrical › Electrical Distribution System (service) › Outlet Box
Issued 7 February 2003
Resolved
Install cover to electrical outlet in wheelhouse.
Condition: Improper Installation
Due 7 March 2003
Resolved 10 March 2003
Electrical › Electrical Distribution System (service) › Junction Box
Issued 7 February 2003
Resolved
Install cover or remove junction box under wheelhouse.
Due 7 March 2003
Resolved 10 March 2003
Electrical › Lighting (service) › Lighting Fixture
Issued 7 February 2003
Resolved
Properly repair or renew lighting fixture in forepeak.
Condition: Improper Installation
Due 7 March 2003
Resolved 10 March 2003
Electrical › Electrical Distribution System (service) › Switch
Issued 7 February 2003
Resolved
Install cover to light switch IWO heating unit.
Condition: Improper/Lack of Maintenance
Due 7 March 2003
Resolved 10 March 2003
Fire Fighting › Combustible Materials
Issued 7 February 2003
Resolved
Remove combustables IWO heating unit.
Due 7 March 2003
Resolved 10 March 2003
Electrical › Electric Supply System (service) › Battery Installation Ventilation
Issued 7 February 2003
Resolved
Remove muti-outet extension cords from galley.
Condition: Improper Installation
Due 7 March 2003
Resolved 10 March 2003
Construction/Loadline › Hull › Weld
Issued 7 February 2003
Resolved
C/R #9 & #10 port bulwark stiffeners at deck.
Condition: Unknown
Due 30 June 2003
Resolved 30 September 2004
Resolution: Receive fax from Tug Supervisor (Kea-Sea) that issue has been fixed and is in full compliance.
Construction/Loadline › Hull › Weld
Issued 7 February 2003
Resolved
C/R bulwark IWO of #9 & #10 port stiffeners.
Due 30 June 2003
Resolved 30 September 2004
Resolution: Receive fax from Tug Supervisor (Kea-Sea) that issue has been fixed and is in full compliance.
Construction/Loadline › Hull › Weld
Issued 7 February 2003
Resolved
C/R 2nd deck IWO #3 port hand rail stanchion aft of lighted ring life buoy.
Condition: Unknown
Due 30 June 2003
Resolved 30 September 2004
Resolution: Receive fax from Tug Supervisor (Kea-Sea) that issue has been fixed and is in full compliance.
Documentation › Certificates/Documents › FCC SSL
Issued 7 February 2003
Resolved
Provide FCC station license.
Due 7 March 2003
Resolved 10 March 2003
Documentation › Certificates/Documents
Issued 7 February 2003
Resolved
Provide radio operators permit.
Due 7 March 2003
Resolved 10 March 2003