Records from 2000 to 2025. Most recent: inspection, 23 July 2025.
Documentation record
Registered dimensions (L × B × D)38.7 ft × 12.0 ft × 4.2 ft
Registered tonnagegross 13 / net 9
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderWALKER BOAT YARD · PADUCAH, KY, UNITED STATES · built 1952
Hull materialSteel
PropulsionNot recorded
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portST LOUIS, MO
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 23 December 2025 · expires 31 January 2027
Service, as the file records itTowing Vessel
Hull formunknown (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it13 - Regulatory (Subpart C or D), Gross Ton
9 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Inspection history · 14
23 July 2025
Annual Inspection · Deficiency Check
Physical examination · Marine Safety Detachment Cincinnati · USCG Heartland District (CGD-H) · Activity 8192590
25 July 2024
Annual Inspection
Physical examination · Marine Safety Detachment Cincinnati · USCG Heartland District (CGD-H) · Activity 7966786
10 October 2023
Deficiency Check · Annual Inspection
Physical examination · Marine Safety Detachment Cincinnati · USCG Heartland District (CGD-H) · Activity 7805799
16 June 2022
Annual Inspection · Deficiency Check
Physical examination · Marine Safety Detachment Cincinnati · USCG Heartland District (CGD-H) · Activity 7479333
29 June 2021
Deficiency Check · Initial Certification
Physical examination · Marine Safety Detachment Cincinnati · USCG Heartland District (CGD-H) · Activity 7237921
24 May 2021
Administrative Inspection
Administrative · Commandant (CG-CVC) · Activity 7205266
28 August 2016
Type not recorded
No type recorded · Marine Safety Detachment Cincinnati · USCG Heartland District (CGD-H) · Activity 5985609
19 August 2014
Industry Initiated Exam
Physical examination · Marine Safety Detachment Cincinnati · USCG Heartland District (CGD-H) · Activity 4952293
18 June 2013
Spot Check (Safety)
Physical examination · Marine Safety Detachment Cincinnati · USCG Heartland District (CGD-H) · Activity 4590240
19 June 2012
Uninspected Other · Deficiency Check
Physical examination · Marine Safety Detachment Cincinnati · USCG Heartland District (CGD-H) · Activity 4376468
19 January 2012
Type not recorded
No type recorded · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 4229646
29 June 2010
Industry Initiated Exam
Physical examination · Marine Safety Detachment Cincinnati · USCG Heartland District (CGD-H) · Activity 3781349
25 January 2008
Type not recorded
No type recorded · Marine Safety Detachment Cincinnati · USCG Heartland District (CGD-H) · Activity 3136382
12 July 2000
Type not recorded
No type recorded · Marine Safety Detachment Cincinnati · USCG Heartland District (CGD-H) · Activity 280945
04 - Emergency Systems › N/A - No Subsystem › Fire drills
Issued 23 July 2025
Resolved
Drills have not been conducted on the vessel for May, June and July of 2025. The master of a towing vessel must ensure that each crew member participates in fire-fighting drills and receives instruction at least once each month. Conduct drills and training for all crew and provide documentation attesting to the same to the satisfaction of the attending Coast Guard marine inspector.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 5 August 2025
Resolved 30 July 2025
Resolution: Received documentation that training and drills had been completed.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 10 October 2023
Resolved
Fuel shutout valve is located on the engine. Fuel shutoff valves must be installed in the fuel piping directly outside the fuel supply tank. Move fuel shutout valve directly outside fuel tank to the satisfaction of the attending Coast Guard Marine inspector.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 10 November 2023
Resolved 31 October 2023
Resolution: Received objective evidence new remote installed near tank.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 16 June 2022
Resolved
Vessel did not provide annual health and safety training. Health and safety plan refresher training must be completed annually and maybe conducted over time in models. Provide training and written documentation for crew attending training to the satisfaction of the attending Coast Guard marine inspector.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 June 2022
Resolved 28 June 2022
Resolution: Owner conducted training and provided records.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 16 June 2022
Resolved
Vessel does not have hand rails or bulwarks on periphery of vessel. Rails or equivalent protection must be installed near the periphery of all decks accessible to crew. Equivalent protection may include lifelines, wire rope, chains, and bulwarks that provide strength and support equivalent to fixed rails. (b) In areas where space limitations make deck rails impractical, such as at narrow catwalks in way of deckhouse sides, hand grabs may be substituted. Owner shall install handrails on stern of vessel. Owner shall create written policy for crew included in health and safety plan to instruct crew members not to walk down outboard side of vessel while in transit. Owner shall place a sign reminding crew not to transit outboard side of vessel. To the satisfaction of the attending Coast Guard Marine inspector.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 16 July 2022
Resolved 28 June 2022
Resolution: Stern rail installed and written policy and signs are in place.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 24 May 2021
Resolved
All owners and operators of an existing towing vessel must have a valid COI prior to the specified phase-in period. This vessel is one of the associated fleet that has not obtained a valid COI. The vessel shall be made available for a Coast Guard COI inspection within 90 days. If an inspection is not completed prior to this date, the action for this deficiency shall be changed to a 60 (Rectify deficiencies prior to movement) and the vessel may no long be permitted to operate.
Condition: Invalid
Action required: 705 - Other - as specified
Due 24 August 2021
Resolved 6 July 2021
Resolution: Co has COI in draft status. Co at 50% (2 of 3).
Engineering › Freshwater System (jacketwater cooling) › Hose
Issued 19 June 2012
Resolved
Replace the raw water cooling discharge hose that is currently kinked and provide a means to reduce the kinking as discussed with the vessel master.
Action required: 705 - Other - as specified
Due 19 July 2012
Resolved 23 July 2012
Resolution: Raw water discharge hose waas replaced and re-positioned to prevent kinking.
Electrical › Electrical Distribution System (service) › Wiring
Issued 19 June 2012
Resolved
Remove all plastic wire ties throughout the engine room that are currently being used to secure the wiring and replace with metal supports.
Action required: 705 - Other - as specified
Due 19 July 2012
Resolved 23 July 2012
Resolution: Plastic wire ties were removed and replaced with metallic supports.
Electrical › Electrical Distribution System (service) › Distribution Panel Bus
Issued 19 June 2012
Resolved
Provide a suitable cover for the exposed bus on the main engine aft.
Action required: 705 - Other - as specified
Due 19 July 2012
Resolved 23 July 2012
Resolution: A cover was affixed to protect the exposed bus off the main engine.
Engineering › Freshwater System (jacketwater cooling) › Hose
Issued 19 June 2012
Resolved
Remove all the accumulated grease from off the raw water intake hose for the main engine. Grease is collecting from the universal joint right above the intake hose.
Action required: 705 - Other - as specified
Due 19 July 2012
Resolved 27 July 2012
Resolution: All accumulated grease on the raw water intake hose was removed.
Electrical › Electrical Distribution System (service) › Wiring
Issued 19 June 2012
Resolved
Properly secure and stuff the wire connections on the bow of the vessel that are used to provide electrical power to the navigation lights on the BOONE NO. 8
Action required: 705 - Other - as specified
Due 19 July 2012
Resolved 23 July 2012
Resolution: The wire connection was properly stuffed and no exposed wiring was observed.