Records from 2003 to 2026. Most recent: inspection, 26 March 2026.
Documentation record
Registered dimensions (L × B × D)136.1 ft × 36.0 ft × 12.0 ft
Registered tonnagegross 88 / net 67
ITC dimensions (L × B × D)136.1 ft × 36.0 ft × 12.0 ft
ITC tonnagegross 432 / net 129
BuilderHALIMAR SHIPYARD LLC · MORGAN CITY, LA, UNITED STATES · built 2004
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeShip
Hull configurationMonohull
Hailing portBAYOU LA BATRE, AL
Trade endorsementsCoastwise, unrestricted, Registry
DocumentationValid · issued 28 July 2026 · expires 31 August 2027
Service, as the file records itOffshore Supply Vessel
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it88 - Regulatory (Subpart C or D), Gross Ton
432 - Convention (Subpart B), Gross Ton
67 - Regulatory (Subpart C or D), Net Ton
129 - Convention (Subpart B), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Inspection history · 33
26 March 2026
Bulk Liquid Transfer Monitor
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 8332411
20 November 2025
Bulk Liquid Transfer Monitor
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 8271707
7 November 2025
Type not recorded
No type recorded · USCGC YELLOWFIN (WPB 87319) · USCG Southeast District (CGD-SE) · Activity 8266099
31 July 2023
Type not recorded
No type recorded · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7763161
25 July 2023
Damage Survey
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 7752212
24 July 2023
Type not recorded
No type recorded · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 7762225
18 July 2022
Annual Inspection · Examination of Repairs · Drydock Exam · Internal Structural Exam
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 7510091
10 September 2021
Deficiency Check · Annual Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 7309369
4 September 2020
Damage Survey
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 7049971
4 September 2020
Type not recorded
No type recorded · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 7073082
19 May 2020
COI Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 6956044
23 September 2019
Drydock Exam · Internal Structural Exam · Hull Examination
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 6826106
5 September 2019
Administrative Inspection
Administrative · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 6805063
15 January 2019
Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 6610716
14 November 2017
Hull Examination · Internal Structural Exam · Periodic Inspection · Administrative Inspection · Deficiency Check
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 6306992
31 May 2017
Damage Survey
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6161798
4 January 2017
Administrative Inspection · MTSA Verification · Annual Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 6066006
6 June 2016
In-Service Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 5932988
13 November 2015
Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6087246
23 October 2014
Hull Examination · MTSA Verification · Internal Structural Exam · Administrative Inspection · COI Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 5010774
11 January 2012
Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 4222372
1 February 2011
Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3937220
22 December 2009
Administrative Inspection · Examination of Repairs · Hull Examination · MTSA Verification · Ballast Water Examination · COI Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3654254
26 February 2009
Annual Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3380494
9 April 2008
Damage Survey · Administrative Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3180824
14 March 2008
Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3180135
5 November 2007
Ballast Water Examination · MTSA/ISPS Verification · Hull Examination · Re-Inspection · Examination of Repairs
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3093385
12 December 2005
Ballast Water Examination · Re-Inspection · MTSA Verification
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 2549811
18 February 2005
Deficiency Check
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 2293037
15 February 2005
Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 2293036
14 January 2005
Administrative Inspection
Administrative · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 2275569
1 December 2004
Security Plan Review - ASP
Administrative · Marine Safety Center (MSC) · Activity 2251227
15 October 2003
Initial Construction-Excluding Oversight · Initial Certification · Inclining Experiment · MTSA Verification
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1928801
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 10 September 2021
Resolved
The main means of steering (main steering gear) must be of adequate strength for, and capable of, steering the OSV at each service speed. Both rudders were shaking when in operation and the port rudder post was loose and shaking inside the through hull penetration.
46 CFR 130.130(c)(1)
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 24 September 2021
Resolved 20 September 2021
Resolution: Both rudders were replace. Inspected installation. After vessel was floated, witnessed sat steering test.
07 - Fire Safety › N/A - No Subsystem › Remote Means of control (opening,pumps,ventilation,etc.) Machinery spaces
Issued 10 September 2021
Resolved
Shut off valves shall be installed in the fuel supply lines, one as close to each tank as practicable, and one as close to each fuel pump as practicable. Valves shall be accessible at all times. Both remote fuel oil shut off valves, located on the back deck, were seized and not easily operated. It took the crew approximately 15 minutes to close each valve and the crew had to use a hammer to break it free and then a "cheater" bar to turn the t-handle.
46 CFR 56.50-75(b)(4)
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 24 September 2021
Resolved 20 September 2021
Resolution: Reach rod universal joints were replaced. Fuel tank was pumped, gas freed and the universal joints were replaced. Port and stbd day tanks.
09 - Working and Living Conditions › 092 - Working Conditions › Anchoring devices
Issued 10 September 2021
Resolved
Each OSV of less than 100 gross tons must be fitted with groundtackle, mooring, and towing equipment meeting the applicable requirements for small passenger vessels in 184.300 of this chapter. The vessel's forward anchor was seized in place, painted over, not connected to the chain/winch, and incapable of being safely deployed at the time of inspection.
46 CFR 130.250
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 24 September 2021
Resolved 20 September 2021
Resolution: Anchor was cleaned made ready for use.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Doors
Issued 10 September 2021
Resolved
Watertight doors in bulkheads that have been made watertight to comply with flooding or damage stability regulations must comply with regulations in subchapter S. The closing mechanism on the quick acting watertight door servicing the engine room emergency escape trunk did not allow for each dog to properly engage the doors wedges.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 24 September 2021
Resolved 20 September 2021
Resolution: Door was adjusted and a chalk test was witnessed.
07 - Fire Safety › N/A - No Subsystem › Ventilation
Issued 10 September 2021
Resolved
Means must be provided for closing each vent serving machinery and cargo spaces in the case of a fire. Two ventilation closures serving the engine room were missing fasteners to close cover.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 24 September 2021
Resolved 20 September 2021
Resolution: Borken closing devices were replaced.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 4 September 2020
Resolved
The owner or operator of an OSV shall make the vessel available for inspection each time an accident occurs or a defect is discovered that affects the safety of the vessel or a defect is discovered that affects vessel equipment. Vital systems are those systems that are vital to the vessel's survivability and safety. Vital systems include propulsion systems and their necessary auxiliaries and control systems. Vessel is experiencing heavy vibrations from the port tail shaft after running aground. Make arrangements to inspect vessel for damage and make any necessary repairs to the satisfaction of the OCMI.
Condition: Damaged By Earlier Event
Action required: 17 - Rectify deficiencies prior to departure
Due 18 September 2020
Resolved 10 September 2020
Resolution: Examined repairs.
Lifesaving › Lifefloat › Serviceable
Issued 2 January 2018
Resolved
Existing lifefloat bodies are cracked and unserviceable. All lifefloats must be replaced prior to sail.
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Due 2 February 2018
Resolved 11 January 2018
Resolution: All lifefloats were replaced and were properly stenciled, equipped, and stowed.
Lifesaving › Lifebuoys › Markings (ship name/port)
Issued 2 January 2018
Resolved
Replace retro-reflective tape on stbd ring buoy outside of pilothouse.
Condition: Improper Installation
Action required: 60 - Rectify deficiencies prior to movement
Due 2 February 2018
Resolved 11 January 2018
Resolution: Retro-reflective tape was replaced on ring buoy.
Engineering › Diesel Engine (propulsion-reduction gear) › Governor
Issued 15 October 2003
Resolved
Submit revised failure simulation test procedures for the propulsion control system, to include all requirements of MSC comment letter E2-0402482 dated 13SEP04. See permanent vessel file.
Action required: 705 - Other - as specified
Due 30 January 2005
Resolved 15 February 2005
Resolution: Completed.
Engineering › Diesel Engine (propulsion-reduction gear) › Governor
Issued 15 October 2003
Resolved
Demontrate compliance with the failsafe requirement in 46 CFR 130.120(d) (propulsion controls) through onboard testing in the presence of a CG marine Inspector. Testing shall include approved failure simulation test procedures. See MSC comment letter E2-0402482, dated 13SEP04.
Action required: 705 - Other - as specified
Due 26 February 2005
Resolved 25 February 2005
Resolution: Satisfactory test''s completed with electrical technician.