09 - Working and Living Conditions › 092 - Working Conditions › Protection machines/parts
Issued 6 May 2026
Resolved
An exposed hazard such as rotating machinery must be protected by a cover, guard or rail. Rotating shafts were exposed in engine room.
Condition: Placed in Improper Service
Action required: 16 - Rectify deficiencies w/in 14 days
Due 19 May 2026
Resolved 19 May 2026
Resolution: MI received objective evidence that guards were installed over shafts
04 - Emergency Systems › N/A - No Subsystem › Water level indicator
Issued 6 May 2026
Resolved
Each towing vessel must have a reliable means to provide notification when an emergency condition exists or an essential system develops problems that require attention. The following alarms must be provided: High bilge levels.
High bilge alarm for shaft alley was inoperable at operating station. Repair high bilge alarm indicator.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 19 May 2026
Resolved 19 May 2026
Resolution: MI received objective evidence that bilge alarms were operable at the operating station
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 6 May 2026
Resolved
Each towing vessel must have a fire-detection system installed to detect engine room fires. The owner or managing operator must ensure the following: The design of the system and its installation on the towing vessel is certified and inspected by a registered professional engineer with experience in fire-detection system design.
Vessel could not provide paperwork from registered engineer verifying design and installation is certified and approved by registered professional engineer.
Submit proof submit attesting to such.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 19 May 2026
Resolved 19 May 2026
Resolution: MI received a copy of PE letter for fire detection system
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 6 May 2026
Resolved
Each towing vessel must perform the applicable tests in Table 143.245(b) of this section. Essential systems, including emergency dewatering systems, must be tested once every 3 months.
No test record was available for inspection.
MI tested emergency dewatering systems. Corrected on spot.
Condition: Invalid
Action required: 10 - Deficiency Rectified
Due 6 May 2026
Resolved 6 May 2026
Resolution: MI witnessed operation of bilge system
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 2 April 2025
Resolved
A towing vessel subject to this subchapter and choosing the Coast Guard inspection option, or required to have the Coast Guard inspection option, must undergo an annual inspection within 3 months before or after the COI anniversary date. Vessel was unable to finish the annual inspection due to not have crew present. The following needs to be inspected: main engines, generators, propulsion, steering systems, high water alarm, fire pump and hoses, e-lighting, general alarm, fire detection system, and MMCs.
Action required: 705 - Other - as specified
Resolved 29 April 2025
Resolution: Witnessed proper operation of main engines, generators, propulsion, steering systems, high water alarm, fire pump and hoses, e-lighting, general alarm, fire detection system, and verified MMCs for crew.
11 - Life Saving Appliances › N/A - No Subsystem › Inflatable liferafts
Issued 2 April 2025
Resolved
Each life raft must be arranged for float-free launching. The arrangement must ensure that the life raft, when released and inflated, are not dragged under by the sinking vessel. The painter line of the inflatable life raft was secured to the vessel, which would result in the raft being dragged under by the sinking vessel. Correctly attached the painter to the HRU.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 29 April 2025
Resolution: Liferaft was properly installed.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 2 April 2025
Resolved
Machinery systems must be maintained to provide for safe operation of the towing vessel and safety of persons onboard under normal and emergency conditions. Soft patch found in fwd ER compartment on bilge system. Conduct necessary repairs.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 29 April 2025
Resolution: Fwd engine room bilge piping was properly repaired.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 2 April 2025
Resolved
All installed bilge piping must have a check/foot valve in each bilge suction that prevents unintended back flooding through bilge piping. Bilge piping in fwd ER has a positive control valve installed in place of a check valve. Remove inappropriate valves in entire piping system, and ensure check/foot valves are installed where needed.
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Resolved 29 April 2025
Resolution: Inspection of bilge piping showed proper installation of check valve and ability to pull water from each compartment.
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 2 April 2025
Resolved
All bilges and void spaces are kept free from accumulation of combustible and flammable materials and liquids. ER bilges have an excessive amount of oil. Clean bilges.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 29 April 2025
Resolution: Bilge was clean and free from excessive oil.
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 2 April 2025
Resolved
Each towing vessel must be equipped with an industrial type first aid cabinet or kit, appropriate to the size of the crew and operating conditions. Each towing vessel operating on oceans, coastwise, or Great Lakes routes must have a means to take blood pressure readings, splint broken bones, and apply large bandages for serious wounds. Numerous items in first aid kit were outdated, and kit is missing additional equipment.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 29 April 2025
Resolution: First aid kit was renewed with proper equipment.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 2 April 2025
Resolved
Electrical systems and equipment must function properly and minimize system failures and fire and shock hazards. Exposed wiring is dangling near the MSD in ER. Conduct necessary repairs.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 29 April 2025
Resolution: Dead end wiring was removed.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 2 April 2025
Resolved
Flammable and combustible products must not be stored in machinery spaces. Flammable liquids are stored in the ER. Relocate to appropriate location.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 29 April 2025
Resolution: Flammable materials was properly stowed in a flamelocker.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 2 April 2025
Resolved
Towing vessels must carry the appropriate number of lifebuoys on board. Found wasted ring buoys. Renew.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 29 April 2025
Resolution: Lifebuoys were renewed.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 2 April 2025
Resolved
At least one lifebuoy must have a lifeline, secured around the body of the lifebuoy. The lifeline on the lifebuoy does not meet the requirements of part 141.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 29 April 2025
Resolution: Ring buoy had a proper line attached.
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 2 April 2025
Resolved
A towing vessel must carry a combination of day and night visual distress signals indicated in Table 141.370 of § 141.370 for specified areas where the vessel operates. Distress signals are expired. Renew signals.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 29 April 2025
Resolution: Flares were onboard and not expired.
11 - Life Saving Appliances › N/A - No Subsystem › Immersion suits
Issued 2 April 2025
Resolved
Each towing vessel operating in the applicable regions must carry at least one appropriate-size immersion suit. Vessel has inappropriate sized immersion suits for the normal crew. Ensure sizing of suits are provided and marked correctly.
Condition: Improper Installation
Action required: 705 - Other - as specified
Resolved 29 April 2025
Resolution: An additional immersion suit was added to the vessel.
04 - Emergency Systems › N/A - No Subsystem › Fire drills
Issued 2 April 2025
Resolved
The master of a towing vessel must ensure that drills are conducted and instructions are given to ensure that all crewmembers are capable of performing the duties expected of them during emergencies. There are no records of any drills conducted found in the TVR. Conduct drill and ensure records are maintained.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 29 April 2025
Resolution: A fire drill was recorded in the TVRB.
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance and inspections
Issued 2 April 2025
Resolved
Inspections and tests of lifesaving equipment must be recorded in the TVR. Unable to locate inspection records. Conduct necessary inspections and ensure records are maintained.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 29 April 2025
Resolution: Lifesaving equipment maintenance is conducted and will be recorded.
01 - Certificates & Documentation › 012 - Crew Certificates › Evidence of Basic Training
Issued 2 April 2025
Resolved
Safety orientations and other crew training must be documented in the TVR. Most recent records are in 2021. Conduct safety orientation and other training for all crew members and ensure records are maintained.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 29 April 2025
Resolution: Basic, company, and vessel training records are kept digitally and can be accessed through computers on each vessel.
07 - Fire Safety › N/A - No Subsystem › Maintenance of Fire protection systems
Issued 2 April 2025
Resolved
The records of inspections and tests of fire-detection systems and fixed fire-extinguishing systems must be recorded in the TVR. Unable to locate inspection records. Conduct necessary inspections and ensure records are maintained.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 29 April 2025
Resolution: Fire detection and extinguishing systems were serviced with certification documentation on board.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 2 April 2025
Resolved
A towing vessel must carry adequate and up-to-date charts, maps, and nautical publications for the intended voyage. Nautical publications are out-of-date. Ensure all publications are up-to-date.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 29 April 2025
Resolution: Nav pubs were up to date.
05 - Radio Communications › N/A - No Subsystem › Other (radio communication)
Issued 2 April 2025
Resolved
Each U.S. flag vessel subject to this subpart must have an inspection of the required radiotelephone installation at least once every 48 months. Required certificates required by the FCC are expired. Renew applicable certificates.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 29 April 2025
Resolution: FCC documents were renewed.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 25 September 2023
Resolved
Port side floating electric water light attached to ring life buoy inoperable.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 8 October 2023
Resolved 3 October 2023
Resolution: Purchased new ACR SM-3 model ring life buoy lights.
04 - Emergency Systems › N/A - No Subsystem › Abandon ship drills
Issued 25 September 2023
Resolved
Abandon ship/fire drills had not been logged since August 2022.
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Due 8 October 2023
Resolved 26 September 2023
Resolution: Vessel rep sent sufficient evidence that drills and crew orientation have been conducted.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 25 September 2023
Resolved
Fire control panel batteries were dead and trouble alarm displayed.
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Due 8 October 2023
Resolved 25 September 2023
Resolution: Vessel rep sent video of fire panel fully operational.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 24 August 2022
Resolved
The outside line on three lifebuoys are sun damaged and falling apart. Renew three lifebuoys.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 1 September 2022
Resolution: 3 new life buoys have been ordered. Items will be delivered 9/2.
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 24 August 2022
Resolved
Shaft alley high water alarm is inoperable. Repair the alarm.
Action required: 60 - Rectify deficiencies prior to movement
Resolved 1 September 2022
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 24 August 2022
Resolved
The fire detection panel shows trouble. Show proper operation of the detection panel.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 1 September 2022
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 24 August 2022
Resolved
The shore power connection is secured with wire nuts. Secure connection in an approved junction box.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 1 September 2022
11 - Life Saving Appliances › N/A - No Subsystem › Launching arrangements for survival craft
Issued 3 November 2021
Resolved
Hydrostatic release on inflatable liferaft incorrectly installed, upside down. Correct on site prior to completion of the exam, per 46 CFR 141.235
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 3 November 2021
Resolved 3 November 2021
Resolution: Vessel captain installed the hydrostatic release right side up.
05 - Radio Communications › N/A - No Subsystem › Performance standards for radio equipment
Issued 3 November 2021
Resolved
FCC Vessel Bridge to Bridge and safety radio telephone certificate Expired. Company required to maintain certificate IAW 47CFR80.13
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 3 December 2021
Resolved 3 December 2021
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 3 November 2021
Resolved
Contents/Documentation in vessels Towing Vessel Record (TVR) missing or not updated as required by 46 CFR 140.820. CG Marine Instpector to review with owner.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 17 November 2021
Resolved 18 November 2021
01 - Certificates & Documentation › 013 - Documents › Shipboard working arrangements
Issued 3 November 2021
Resolved
No documentation available for companies Health and Safety Plan on board vessel, unable to verify as required by 46 CFR 140.500. CG Marine Inspector to review with owner.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 17 November 2021
Resolved 18 November 2021
10 - Safety of Navigation › N/A - No Subsystem › Nautical publications
Issued 3 November 2021
Resolved
Notice to Mariners is not onboard vessel as required by 33 CFR 164.72. Although Master used his personal phone to obtain. CG Marine Inspector recommends laptop or tablet be onboard and keep up to date. CG MI will discus with owner.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 17 November 2021
Resolved 18 November 2021
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 3 November 2021
Resolved
Missing 5 day and 3 night Visual Distress Signals. Obtain flares before exceeding 3 miles from shore IAW 46 CFR 141.375(a)
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 3 November 2021
Resolved 3 November 2021
Resolution: master purchased additional flares.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 3 November 2021
Resolved
Missing Blood Pressure cuff, expired asprin and first aid cream in First Aid Kit obtain new IAW 46 CFR 140.435
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 17 November 2021
Resolved 3 November 2021
Resolution: Purchased and stored on board new blood pressure cuff, asprin, and 1st aid cream.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 1 September 2020
Resolved
Observed one portable CO2 fire extinguisher in the master cabin, inspection date more than one year. Required the portable CO2 fire extinguisher in the master's cabin be serviced and or replaced, IAW 46CFR142.240
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 1 September 2020
Resolved 1 September 2020
Resolution: replaced extinguisher with one from ship yard that was serviced.
05 - Radio Communications › N/A - No Subsystem › Performance standards for radio equipment
Issued 1 September 2020
Resolved
Great Lakes annual FCC serving; report was not available during CG MI's attendance. Company required to provide an annual FCC serving report to CGMI.IAW 47CFR80 as required per 46 CFR 140.615
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 14 September 2020
Resolved 14 September 2020
Resolution: Completed, verified certificates.
08 - Alarms › N/A - No Subsystem › Fire alarm
Issued 1 September 2020
Resolved
Observed batteries missing in the pilot house fire alarm panel. Company required to replace missing batteries. IAW 46CFR142.330
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 14 September 2020
Resolved 14 September 2020
Resolution: Completed, verified battery backup installed.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 1 September 2020
Resolved
Alcohol Breath Analyzer onboard was 3 years old, never used or serviced. Company required to provide calibration documentation for the alcohol testing equipment or replace with other means of testing. IAW 46CFR16.203
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 14 September 2020
Resolved 14 September 2020
Resolution: Completed, alcohol test strips provided on vessel.
09 - Working and Living Conditions › 092 - Working Conditions › Guards - fencing around dangerous machinery parts
Issued 1 September 2020
Resolved
Observed protective guard between the steering pump electric motor and hydraulic pump was removed. Company required to reinstall the guard. IAW 46CFR143.550
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 14 September 2020
Resolved 14 September 2020
Resolution: completed, verified guard reinstalled.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 1 September 2020
Resolved
Observed main switchboard non conductive mat missing. Company required to install non conductive matting in front of the E/R main switchboard. IAW 46CFR143.560
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 14 September 2020
Resolved 14 September 2020
Resolution: completed, verified mats placed in ER.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 1 September 2020
Resolved
Observed E/R heat detector above port SSDG was not properly attached to junction box, with detector hanging from wires. Company instructed to correct and properly installed. IAW 46CFR142.330
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 14 September 2020
Resolved 14 September 2020
Resolution: verified proper installation.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 1 September 2020
Resolved
Observed cables in front of the starboard side generator (inside a junction box) were not properly attached. Company instructed to correct and properly install. IAW 46CFR143.575
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 14 September 2020
Resolved 14 September 2020
Resolution: verified proper installation.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 1 September 2020
Resolved
Observed valves handles missing on both engine room fuel oil tanks sight glasses and laying in the E/R Bilge. Required both valve handles to be reinstalled on both site glass.
46CFR143.255
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 14 September 2020
Resolved 14 September 2020
Resolution: verified handles in place.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 1 September 2020
Resolved
Observed in vessels galley an electrical outlet cover was missing. Company required to install the missing electrical outlet cover. IAW 46CFR143.575
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 14 September 2020
Resolved 14 September 2020
Resolution: completed.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 1 September 2020
Resolved
Observed two electrical controllers were not label on exterior aft fantail. Required both electrical controllers to be labeled. IAW 46 CFR 143.560
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 14 September 2020
Resolved 14 September 2020
Resolution: marked and identified.
11 - Life Saving Appliances › N/A - No Subsystem › Launching arrangements for survival craft
Issued 1 September 2020
Resolved
Observed the life raft hydrostatic release was expired. Company reps stated the thought the hydro was renewed when life raft serviced. Company reps informed renewal of the hydrostatic release was independent from life raft serving and renewal required every two years. Required the expired hydrostatic release be renewed. IAW 46 CFR 141.235
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 14 September 2020
Resolved 14 September 2020
Resolution: verified new hydro static installed.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 1 September 2020
Resolved
During man overboard drill, master broke the pilot house whistle activation lever. Company required to repair, before vessels next voyage.
Condition: Design Flaw
Action required: 17 - Rectify deficiencies prior to departure
Due 14 September 2020
Resolved 14 September 2020
Resolution: verified lever was fixed handle.
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 9 May 2019
Resolved
Company failed to fully fill out various forms as required by companies Towing Vessel Record (TVR) Subchapter Compliance Management System (Maritime Compliance International, LLC Publication). Forms list include operations, Survey’s, Inspections, & training. Applicable forms include O-1 thru 0-13, S- thru S-11, & T-1 thru T-3, must be filled out, complete and re-verified by attending CG Marine Inspector.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 19 July 2019
Resolved 12 August 2019
Resolution: TVR was on board and reviewed, 0-1 thru 0-13 and T-1 thru T-3 were completed. Educated owner on some of the forms with ECFR website. Discussed good marine practice with information on forms. Inportance of corrective action reports ect..
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 9 May 2019
Resolved
Simply the vessels emergency duties and stations duties/checklist.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 19 July 2019
Resolved 12 August 2019
Resolution: watch quarter station bill posted. also part of the TVR IN T-1, 0-13, 0-5.
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 9 May 2019
Resolved
Properly outfit first aid kit; miss blood pressure & splint.
Action required: 705 - Other - as specified
Due 19 July 2019
Resolved 12 August 2019
Resolution: First aid kit meets the industry standard
11 - Life Saving Appliances › N/A - No Subsystem › Stowage and provision of liferafts
Issued 9 May 2019
Resolved
Life Raft not connected in a float free arrangement, reconfigure.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 1 June 2019
Resolved 10 May 2019
11 - Life Saving Appliances › N/A - No Subsystem › On board training and instructions
Issued 9 May 2019
Resolved
Missing life raft launching instructions, post instructions.
Action required: 705 - Other - as specified
Due 19 July 2019
Resolved 12 August 2019
Resolution: Instructions posted at Liferaft and listed in TVR
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 9 May 2019
Resolved
Fire Detection panel inoperable, correct
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 10 May 2019
Resolution: CG MI attended and verified proper operation of the detection panel.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 9 May 2019
Resolved
Install smoke detectors in berthing compartments.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 10 May 2019
03 - Water/Weathertight Conditions › N/A - No Subsystem › Doors
Issued 9 May 2019
Resolved
Gaskets on water tight door, old and not properly sealing, renew.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 19 July 2019
Resolved 12 August 2019
Resolution: Gaskets renewed and chalked tested.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Windows, sidescuttles and deadlights
Issued 9 May 2019
Resolved
Port light covers missing in the Engine room & Galley. Obtain and install.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 19 July 2019
Resolved 12 August 2019
Resolution: Installed new covers in ER and Galley
10 - Safety of Navigation › N/A - No Subsystem › Rudder angle indicator
Issued 9 May 2019
Resolved
Missing rudder angle indicator at aft station, install.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 19 July 2019
Resolved 12 August 2019
Resolution: Indicator installed
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 9 May 2019
Resolved
Towing gear inspection records missing, complete.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 19 July 2019
Resolved 12 August 2019
Resolution: Towing gear inspection sheet located in TVR.
10 - Safety of Navigation › N/A - No Subsystem › Automatic Identification System (AIS)
Issued 10 September 2018
Resolved
Vessel is displaying an innaccurate IMO number.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 10 October 2018
Resolved 29 November 2018
Resolution: AIS is transmitting the correct IMO number.