JEAN ANNE

JEAN ANNE is a 2005 freight ship. The Coast Guard has recorded 63 inspections since 2016, most recently in May 2026, along with 31 deficiencies and 27 casualty investigations between 2005 and 2025.

Records from 2005 to 2026. Most recent: inspection, 27 May 2026.

Built
2005
Last inspected
27 May 2026
Documentation
Valid · documentation file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the General Dry Cargo Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 27 May 2026
…with no type recorded23
Operational controls None recorded without a removal date
Years with a record 11 calendar years (2016–2026)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

9233167
WDC3786
726146
Flag
UNITED STATES
Maury page id
psix-726146

Documentation record

Registered dimensions (L × B × D)549.2 ft × 101.8 ft × 47.4 ft
Registered tonnagegross 37,548 / net 20,705
ITC dimensions (L × B × D)549.2 ft × 101.8 ft × 47.4 ft
ITC tonnagegross 37,548 / net 20,705
BuilderVT Halter Marine, Inc. · PASCAGOULA, MS, UNITED STATES · built 2005
Hull materialSteel
PropulsionDiesel Direct
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing portSAN FRANCISCO, CA
Trade endorsementsCoastwise, unrestricted, Registry
DocumentationValid · issued 5 January 2026 · expires 31 January 2027
Service, as the file records itFreight Ship
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it20705 - Convention (Subpart B), Net Ton
24800 - Displacement, Ton
12700 - Dead Weight, Ton
37548 - Convention (Subpart B), Gross Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 2016 to 2026 for this class, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspection history · 63

27 May 2026 ACP Annual Oversight · Administrative Inspection · MSP Additional Oversight - Risk Assessment · Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 8352652
16 December 2025 Administrative Inspection
Administrative · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 8284214
16 August 2025 Type not recorded
No type recorded · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 8212702
15 August 2025 Deficiency Check · Damage Survey
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 8211506
14 April 2025 ACP COI Oversight · Annual Inspection · COI Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 8102874
12 February 2025 Administrative Inspection
Administrative · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 8078413
27 November 2024 Administrative Inspection
Administrative · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 8041208
7 November 2024 Type not recorded
No type recorded · OP location-Sector Honolulu Prevention Department- Wailuku · USCG Oceania District (CGD-O) · Activity 8038902
6 November 2024 Administrative Inspection
Administrative · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 8031614
5 November 2024 Type not recorded
No type recorded · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 8033925
18 July 2024 In-Service Inspection · Deficiency Check
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7961789
18 July 2024 Type not recorded
No type recorded · OP location-Sector Honolulu Prevention Department- Kailua Kona · USCG Oceania District (CGD-O) · Activity 7962379
11 July 2024 Administrative Inspection
Administrative · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7956317
9 July 2024 Administrative Inspection
Administrative · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7955542
29 May 2024 Annual Inspection · ACP Annual Oversight · MTSA/ISPS Verification
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7922759
3 February 2024 In-Service Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7861794
31 May 2023 ACP Annual Oversight · Deficiency Check · Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7709691
10 November 2022 Type not recorded
No type recorded · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7598228
4 May 2022 MTSA/ISPS Verification · Periodic Inspection · ACP Annual Oversight
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7443782
12 October 2021 Administrative Inspection
Administrative · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7330948
8 October 2021 Type not recorded
No type recorded · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7341487
6 July 2021 Deficiency Check
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7246843
25 June 2021 Deficiency Check
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7235426
24 June 2021 Type not recorded
No type recorded · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7348383
7 April 2021 Deficiency Check · ACP Annual Oversight · Annual Inspection · MTSA/ISPS Verification
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7170298
7 April 2021 Administrative Inspection
Administrative · Commandant (CG-5P-TI) · Activity 7241678
15 January 2021 Type not recorded
No type recorded · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7125324
15 January 2021 Deficiency Check
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7125417
4 November 2020 ACP Additional Oversight – Risk Assessment
Administrative · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7089934
14 September 2020 Deficiency Check
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7058201
4 September 2020 Type not recorded
No type recorded · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7062929
3 September 2020 Administrative Inspection
Administrative · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7058552
25 June 2020 Type not recorded
No type recorded · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7018470
19 May 2020 Administrative Inspection
Administrative · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6956160
6 May 2020 Type not recorded
No type recorded · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6949288
30 March 2020 Re-Inspection · MTSA/ISPS Verification · ACP COI Oversight · Deficiency Check
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6930690
28 January 2020 ACP Drydock Oversight
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6898185
16 January 2020 Permit to Proceed
Administrative · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6890915
11 November 2019 Administrative Inspection · Deficiency Check · ACP Additional Oversight – Risk Assessment · MTSA/ISPS Verification
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6855292
14 May 2019 ACP Annual Oversight · Annual Inspection · Deficiency Check
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6670994
14 May 2019 Administrative Inspection
Administrative · Commandant (CG-5P-TI) · Activity 6681217
20 April 2019 Type not recorded
No type recorded · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6668095
4 February 2019 ACP Additional Oversight – Risk Assessment · Deficiency Check
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6619936
8 November 2018 Administrative Inspection · Examination of Repairs
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6582314
5 September 2018 Examination of Repairs
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6532603
15 May 2018 ACP Annual Oversight · Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6403020
9 December 2017 Type not recorded
No type recorded · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6334136
5 December 2017 Type not recorded
No type recorded · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6321248
4 December 2017 Administrative Inspection
Administrative · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6318713
16 October 2017 Type not recorded
No type recorded · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6288587
12 August 2017 Type not recorded
No type recorded · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6249922
7 June 2017 Administrative Inspection · Examination of Repairs
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6170830
6 June 2017 Type not recorded
No type recorded · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6175258
3 May 2017 Deficiency Check · ACP Annual Oversight · Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6134771
1 April 2017 Type not recorded
No type recorded · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6145535
31 January 2017 Type not recorded
No type recorded · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6080663
23 January 2017 Type not recorded
No type recorded · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6080688
12 January 2017 Damage Survey
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6070137
6 July 2016 Type not recorded
No type recorded · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 5932117
18 May 2016 Administrative Inspection · Annual Inspection · ACP Annual Oversight
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 5880029
5 February 2016 Type not recorded
No type recorded · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 5810432
3 January 2016 Type not recorded
No type recorded · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 5801804
2 January 2016 Damage Survey
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 5794076

Deficiency record · 31

13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 15 August 2025 Resolved
Vessel reported a loss of propulsion after the main engine lube oil exhaust valve experienced a high temp alarm. Vessel was slowing down to repair a scavenger air leak. Vessel must arrange for a tug assist of appropriate horsepower for their transit from the sea buoy to the dock. Troubleshoot necessary repairs and provide technician report of satisfactory repairs and operation.
Action required: 705 - Other - as specified
Resolved 21 August 2025
Resolution: Received class report of CoC issued.
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 5 May 2025 Resolved
The following fire protection systems shall be kept in good order so as to ensure their required performance if a fire occurs: structural fire protection, including fire-resisting divisions, and protections of openings and penetrations in these divisions. A-60 fire door between engine room and steering gear room has a hole where the lock mechanism used to be.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 5 June 2025
Resolved 2 June 2025
Resolution: Received survey report rectifiying deficiency.
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 5 May 2025 Resolved
The following fire protection systems shall be kept in good order so as to ensure their required performance if a fire occurs: structural fire protection, including fire-resisting divisions, and protections of openings and penetrations in these divisions. Fire door between engine room and separator room, starboard side, has a crack in the upper inboard side of the door frame.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 5 June 2025
Resolved 2 June 2025
Resolution: Received survey report rectifying deficiency.
07 - Fire Safety › N/A - No Subsystem › Maintenance of Fire protection systems
Issued 5 May 2025 Resolved
Maintenance, testing, and inspections shall be carried out based on the guidelines developed by the Organization and in manner having due regard to ensuring the reliability of fire-fighting systems and appliances. The guidelines developed by the Organization, MSC Circular 1432 section 7.11, call for testing (or replacing) portable foam concentrate containers at 5 to 10 year intervals (depending on type). Fire control plan shows a total of 20 3% AFFF 5 gallon pails. Of those spot-checked during the inspection, all were dated over 10 years ago with no record of foam analysis testing. Check all 20 containers and test or replace any that exceed the time allowances in MSC Circular 1432.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 5 June 2025
Resolved 11 June 2025
Resolution: Finding number issued.
11 - Life Saving Appliances › N/A - No Subsystem › Lifeboats
Issued 27 November 2024 Resolved
Vessel's port lifeboat's on-load release mechanism is inopperable. Repair to satisfaction of manufacturer and class. Cite: Solas 74 ChIII, Reg 16; LSA Code 4.4.7.6.2
Action required: 17 - Rectify deficiencies prior to departure
Due 27 November 2024
Resolved 29 November 2024
Resolution: Condition of class was issued.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Cargo & other hatchways
Issued 18 July 2024 Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure that the ship in all respects will remain fit to proceed to sea without danger to ship or persons onboard. Vessel crew discovered damage to main hydraullic line to ram of aft loading ramp and made temporary repairs. Must make permanent repairs to main hydraullic line to the satisfaction of Class.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 August 2024
Resolved 24 July 2024
Resolution: Class Report uploaded in documents tab.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 31 May 2023 Resolved
Emergency generator be capable both of supplying the services mentioned and automatically started and supplying the required load as quickly as is safe and practicable subject to a maximum of 45s. Emergency generator automatically started, emergency generator breaker would not close to supply ship with emergency power. Ships crew replaced faulty breaker rectifying the deficiency.
Action required: 10 - Deficiency Rectified
Resolved 31 May 2023
Resolution: Corrected on the spot with DNV rep present.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 31 May 2023 Resolved
Measures shall be taken to the satisfaction of the Administration to ensure that the equipment is functioning in a reliable manner and that satisfactory arrangements are made for regular inspections and routine tests to ensure continuous reliable operation. Machinery Low Lube oil test equipment not functioning as intended. Replace or repair to comply with maintenance procedures. #1 SSDG over-speed shutdown was unsuccessfully tested from main switchboard, then manually manipulated governor with a wrench to activate shutdown. Repair or replace to comply with procedures.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 June 2023
Resolved 14 June 2023
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 4 May 2022 Resolved
Where a fixed fire detection & alarm system is required for the protection of spaces other than those specified in paragraph 5.1, at least one detector complying with the FSS Code shall be installed in each space. The function shall be tested under varying conditions of ventilation after installation. The 01 smoke detector installed inside the E/R workshop found hanging by a zip tie and would not function when tested in presence of MI.
Action required: 10 - Deficiency Rectified
Resolved 4 May 2022
Resolution: Detector head replaced with spare and tested SAT.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 12 October 2021 Resolved
During outbound transit to HI, VSL lost ability to operate main engine throttles remotely from bridge. VSL posted an engineer for local engine control. VSL is to repair failure pier side and have DNV surveyor provide report to duty MI prior to VSL sailing.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 13 October 2021
Resolution: Repairs verified by class
02 - Structural Conditions › N/A - No Subsystem › Closing devices/watertight doors
Issued 25 June 2021 Resolved
The machinery, boilers and other pressure vessels, associated piping systems and fittings shall be of a design and construction adequate for the service for which they are intended and shall be so installed and protected as to reduce to a minimum any danger to persons on board. When lifting the stern ramp the foot hydraulic line failed and discharged approximately one gallon of hydraulic fuel into the waterway. The vessel is required to repair the failed hydraulic line upon arrival at next port of call.
Condition: Improper/Lack of Maintenance
Action required: 15 - Rectify deficiencies by next port
Resolved 29 June 2021
Resolution: Received surveyor statement as well as master statement attesting to repairs.
08 - Alarms › N/A - No Subsystem › Boiler alarm
Issued 7 April 2021 Resolved
Each oil-fired boiler which is intended to be operated without manual supervision shall have safety arrangements which shut off the fuel supply and give alarm in case of low water level, air supply failure or flame failure. The auxiliary boiler "firing sequence controller" failed in NOV 2020. Boiler combustion failure alarm no longer alarms to engine control station. Crew has operated boiler in emergency operation mode under engineering watch since failure. No notification was made to DNV-GL or USCG until MAR 2021. Chief Engineer shall provide attestation that all boiler safety shutdowns have been tested since failure and boiler shutdowns to safe mode. Chief Engineer shall create boiler watchstanding standing orders to be approved by USCG and DNV-GL. Firing sequence controller shall be replaced within 30 days.
Condition: Invalid
Action required: 17 - Rectify deficiencies prior to departure
Due 7 April 2021
Resolved 7 April 2021
Resolution: C/E statement provided. C/E standing orders to man boiler front approved. Def changed to code 50C to repair . See def #07.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 7 April 2021 Resolved
All machinery shall be designed, constructed, installed and protected to reduce danger to a minimum to persons on board with due regard to hot surfaces. Incinerator #1 found with severly damaged refractory causing paint peeling and hot surfaces on back corner. Properly replace refractory.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 7 May 2021
Resolved 8 April 2021
Resolution: Received DNV-GL survey statement. Refractory issued CA by attending surveyor.
14 - Pollution Prevention › 146 - MARPOL Annex VI › Incinerator incl. operations and operating manual
Issued 7 April 2021 Resolved
Shipboard incineration of garbage containing more than tracers of heavy metals is prohibited. USCG Certificate of Approval does not allow any amount of unburned components in ashes (0%). Unburned metal bands and metal strainer found within combustion chamber in ashes. MARPOL Annex VI/16.2.3
Action required: 10 - Deficiency Rectified
Resolved 7 April 2021
Resolution: Crew educated on requirements.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 7 April 2021 Resolved
All steering gear components shall be of sound and reliable construction. Port side steering gear hydraulic suction piping found excessively leaking during testing. Repair leaking piping.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 7 April 2021
Resolution: Leak repaired. Witnessed by DNV-GL surveyor.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 7 April 2021 Resolved
Steering gear control shall be provided on the navigation bridge and in the steering gear compartment. Emergency steering gear controls at starboard pump found inoperable to port side due to improperly sized plunger pin button to solenoid.
Condition: Improper Installation
Action required: 10 - Deficiency Rectified
Resolved 7 April 2021
Resolution: Solenoid unit replaced in kind.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Scuppers, inlets and discharges
Issued 7 April 2021 Resolved
All inlets and discharges in the shell plating shall be fitted with efficient and accessible arrangements for preventing the accidental admission of water into the ship. OWS discharge pipe found with pinholes just inboard of the skin valve. Permanently repair piping.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 7 April 2021
Resolution: Piping permanently repaired. Witnessed by DNV-GL surveyor.
08 - Alarms › N/A - No Subsystem › Boiler alarm
Issued 7 April 2021 Resolved
Each oil-fired boiler which is intended to be operated without manual supervision shall have safety arrangements which shut off the fuel supply and give alarm in case of low water level, air supply failure or flame failure. The auxiliary boiler "firing sequence controller" failed in NOV 2020. Boiler combustion failure alarm no longer alarms to engine control station. Crew has operated boiler in emergency operation mode under engineering watch since failure. Firing sequence controller shall be replaced within 30 days.
Condition: Damaged By Earlier Event
Action required: 50 - Rectify deficiencies w/in 30 days
Due 8 May 2021
Resolved 19 May 2021
Resolution: PSTP testing witnessed by attending MI.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 15 January 2021 Resolved
The machinery, boilers and other pressure vessels, associated piping systems and fittings shall be of a design and construction adequate for the service for which they are intended and shall be so installed and protected as to reduce to a minimum any danger to persons on board. A weld in a section of pipe that is part of the main fuel system conditioning unit developed a crack and subsequent fuel leak.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 19 February 2021
Resolved 19 January 2021
Resolution: Fuel oil return line repaired and rewelded to the flanges by ABS certified welder. Pressure test was carried out with pressure 220 PSI in workshop. Reference attached class report DNV-GL Id No: 22906 Job Id: 1552079
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Other (cargo)
Issued 5 March 2020 Resolved
Before loading vehicles for stowage each vehicle must be inspected and stowed in accordance with the applicable sections of 49 CFR 176.905 unless the cargo hold has been designated "specially designed and approved for vehicles". The ships crew as well as general arrangement plans denote that the vessel's holds are designated "specially designed and approved for vehicles". This designation was predicated on a Statement-of-Fact issued by DNV-GL on 19FEB2016 in which exclaimed no electrical equipment was installed less than 460mm and all other electrical equipment was installed anti-explosion type. With the exception of the watertight decks each vehicle deck is perforated which may allow the passage of vapors shifting the less than 460mm criteria and the installed electrical equipment could not be verified to be intrinsically safe, flame proof, pressurized/purged, or an increased safety type (e.g. open outlets, marine grade lighting, ramp controllers). Nor were shipboard procedures to electrically isolate the spaces provided. Provide a corrective action plan to ensure vehicles are stowed in accordance with 49 CFR 176.905. 49 CFR 176.905 46 CFR 90.10-38 46 CFR 96.05-1 46 CFR 111.105
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 30 March 2020
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 5 March 2020 Resolved
An A-0 fire boundary shall be provided between the deck separating the steering gear space (7) and cargo space (8). The cable penetration between deck 5 and the steering gear space was found holed and modified. Permanently repair the cable penetration (block type) in accordance with the manufactures instructions. Temporary repair in way of fire stop caulking authorized. The crew stated that other penetrations have been modified in the same manner. Verify the integrity of all fire/watertight boundary penetrations and provide a corrective action plan to remedy. SOLAS(97) II-2/44
Action required: 50 - Rectify deficiencies w/in 30 days
Due 6 April 2020
Resolved 24 April 2020
Resolution: Rcvd satisfactory DNVGL narrative.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 19 November 2019 Resolved
Lighting fittings shall be so arranged as to prevent temperature rises which could damage the cables and wiring, and to prevent surrounding material from becoming excessively hot. Identified lighting without a protective light cover and damaged bulbs located on cargo deck 6 at frame 175 and frame 180. Replace lighting installation in kind. SOLAS 74 (2001 cons) Ch. II-1 Reg 45.7
Action required: 50 - Rectify deficiencies w/in 30 days
Due 19 December 2019
Resolved 21 November 2019
Resolution: Accepted as condition of DNV-GL with a due date of 12/19/2019.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 19 November 2019 Resolved
A fixed carbon dioxide system must comply with the manufacturer's approved Design, Installation, Operation and Maintenance Manual that meets Chapter II-2, Regulation 10.4 of SOLAS 2000 Amendments and the below supplemental requirements (ref. 46 CFR 34.15, 76.15, 95.15). Upon completion of the piping installation, and before the cylinders are connected, a pressure test in accordance with the manufacturer's Design, Installation, Operation, and Maintenance Manual shall be conducted. Per the manufacturer, flexible connections between cylinders and distribution piping of fixed carbon dioxide fire extinguishing systems must be renewed or tested at the appropriate test pressure. The flexible hose on the paint locker fixed fire extinguishing system connecting the extinguishing agent bottle to the manifold is not marked with the MAWP or test pressure date. A review of the maintenance records for the fire extinguishing system revealed that the flexible hose has not been replaced or pressure tested within the last 5 years or more. Replace the flexible hose in kind or provide proof of an appropriate pressure test in accordance with the system manufacturer. SOLAS 74 (2000 Amendment) Ch. II-2 Reg 10.4 and U.S. Supplement to DNV-GL Rules for Classification of Ships and International Conventions Rev. 0
Action required: 50 - Rectify deficiencies w/in 30 days
Due 19 December 2019
Resolved 21 November 2019
Resolution: Accepted as a condition of DNV-GL with a due date of 12/19/2019.
07 - Fire Safety › N/A - No Subsystem › Remote Means of control (opening,pumps,ventilation,etc.) Machinery spaces
Issued 19 November 2019 Resolved
Every oil fuel pipe, which, if damaged, would allow oil to escape from a storage, settling or daily service tank situated above the double bottom, shall be fitted with a cock or valve directly on the tank capable of being closed from a safe position outside the space concerned in the event of a fire occurring in the space in which such tanks are situated. Remote operated fuel valve for diesel tank in Group #4 did not shut when actuated. Valve was exercised and operated successfully when re-tested. SOLAS74 (2001 cons)II-2/15.2.5
Action required: 10 - Deficiency Rectified
Due 19 November 2019
Resolved 19 November 2019
Resolution: Valve was exercised and operated successfully when re-tested.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 14 May 2019 Resolved
Provide check valve for CO2 low pressure system in accordance with Global Fire and Safety Inc. report dated 6 Mar 2019. Class has issued a condition regarding this 835.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 14 June 2019
Resolved 22 May 2019
Resolution: DNV has issued as condition of class. See DNV finding number/report number 1300329 or see documents for details. Issue resolved as of 10Jul2019, DNV report# 1325276 - saved to Def Docs.
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 14 May 2019 Resolved
Provide retro reflective tape for all lifesaving appliances. Current retro tape is not SOLAS approved tape. DNV has issued as a condition of class.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 14 June 2019
Resolved 22 May 2019
Resolution: DNV has issued as condition of class. See DNV finding number/report number 1300329 or see documents for details. Issue resolved as of 10Jul2019, DNV report# 1325276 - saved to Def Docs.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 4 February 2019 Resolved
Demontrate proper operation of the MDE in the way of the exhaust leaks and burnt lagging.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 5 March 2019
Resolved 12 February 2019
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 4 February 2019 Resolved
Demonstrate proper operation of the MDE in the way of lube oil leaks from the exhaust valve actuator.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 5 March 2019
Resolved 17 April 2019
Resolution: Extended - parts on order. 17APR19-Class DVV/GL provided a class report attesting to the L/O leak repairs.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 4 February 2019 Resolved
Provide servicing and proper documentation of the portable fire extinguishers throughout the vessel.
Condition: Improper/Lack of Maintenance
Action required: 15 - Rectify deficiencies by next port
Due 5 March 2019
Resolved 12 February 2019
Lifesaving › Launching Appliances › Davit
Issued 3 May 2017 Resolved
Port life boat Davit: the aft outboard sheave is showing signs of metal delamination. Provide class reort of condition.
Action required: 705 - Other - as specified
Due 3 June 2017
Resolved 2 June 2017
Fire Fighting › Firemans Outfit › Protective Clothing
Issued 3 May 2017 Resolved
Vessel's compliment of fire fighters outfits shall be widely separated: Reference: SOLAS 2001, Chp. 2-II R/17.4
Due 3 June 2017
Resolved 2 June 2017

Casualty record · 27

24 November 2005Routine · role: Involved in a Marine Casualty · serious marine incident, as classified · 1 injured · activity 2546387
16 February 2006Routine · role: Involved in a Marine Casualty · serious marine incident, as classified · 1 injured · activity 2606938
27 March 2006Routine · role: Involved in a Marine Casualty · activity 2624066
15 January 2009Routine · role: Involved in a Marine Casualty · 1 injured · activity 3414177
29 June 2011Routine · role: Involved in a Marine Casualty · serious marine incident, as classified · 1 injured · activity 4063155
25 September 2012Routine · role: Involved in a Marine Casualty · activity 4450192
1 August 2013Routine · role: Involved in a Marine Casualty · activity 4679844
9 June 2014Routine · role: Involved in a Marine Casualty · activity 4892214
25 April 2015Routine · role: Involved in a Marine Casualty · activity 5112087
21 October 2015Routine · role: Involved in a Marine Casualty · activity 5814045
3 January 2016Routine · role: Involved in a Marine Casualty · activity 5801804
6 July 2016Routine · role: Involved in a Marine Casualty · activity 5932117
23 January 2017Routine · role: Involved in a Marine Casualty · activity 6080688
1 April 2017Routine · role: Involved in a Marine Casualty · activity 6145535
6 June 2017Routine · role: Involved in a Marine Casualty · activity 6175258
12 August 2017Routine · role: Involved in a Marine Casualty · activity 6249922
16 October 2017Routine · role: Involved in a Marine Casualty · activity 6288587
5 December 2017Routine · role: Involved in a Marine Casualty · activity 6321248
9 December 2017Routine · role: Involved in a Marine Casualty · activity 6334136
20 April 2019Routine · role: Involved in a Marine Casualty · activity 6668095
25 June 2020Routine · role: Involved in a Marine Casualty · activity 7018470
4 September 2020Routine · role: Involved in a Marine Casualty · activity 7062929
15 January 2021Routine · role: Involved in a Marine Casualty · activity 7125324
8 October 2021Routine · role: Involved in a Marine Casualty · activity 7341487
5 November 2024Routine · role: Involved in a Marine Casualty · activity 8033925
7 November 2024Routine · role: Involved in a Marine Casualty · activity 8038902
16 August 2025Routine · role: Involved in a Marine Casualty · activity 8212702
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.