JESSIE

Built
1957
Last inspected
12 May 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard.

Inspection record

Last inspected 12 May 2026
…with no type recorded5
Operational controls None recorded without a removal date
Years with a record 31 calendar years (1991–2026)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

WDD6568
Flag
UNITED STATES
Tonnage
798 - Regulatory (Subpart C or D), Gross Ton 912 - Convention (Subpart B), Gross Ton 798 - Regulatory (Subpart C or D), Net Ton 273 - Convention (Subpart B), Net Ton
Maury page id
psix-72824
Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 1972 to 2026, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspected as a tow unit · 7

The Coast Guard recorded this vessel and the following in the same inspection activity — normally a tug and the barges in its tow. Only barges and towing vessels are in this archive, so any other vessel type in the same activity does not appear here: these lists are a floor, not a complete manifest.

KIRBY 29407 Tank Barge · MISLE 19119 · 30 November 2007 · activity 3107549FMT 3033 Tank Barge · MISLE 28800 · 30 November 2007 · activity 3107549G L 63 Freight Barge · MISLE 42319 · 30 November 2007 · activity 3107549UNCLE PETER Towing Vessel · MISLE 92004 · 30 November 2007 · activity 3107549KOLBI MICHELLE Towing Vessel · MISLE 116018 · 30 November 2007 · activity 3107549G.L. 170 Freight Barge · MISLE 170944 · 30 November 2007 · activity 3107549ADDI GRACE Towing Vessel · MISLE 506261 · 30 November 2007 · activity 3107549KIRBY 29407 Tank Barge · MISLE 19119 · 30 November 2007 · activity 3107562FMT 3033 Tank Barge · MISLE 28800 · 30 November 2007 · activity 3107562G L 63 Freight Barge · MISLE 42319 · 30 November 2007 · activity 3107562UNCLE PETER Towing Vessel · MISLE 92004 · 30 November 2007 · activity 3107562KOLBI MICHELLE Towing Vessel · MISLE 116018 · 30 November 2007 · activity 3107562G.L. 170 Freight Barge · MISLE 170944 · 30 November 2007 · activity 3107562ADDI GRACE Towing Vessel · MISLE 506261 · 30 November 2007 · activity 3107562KIRBY 29407 Tank Barge · MISLE 19119 · 13 November 2007 · activity 3097419FMT 3033 Tank Barge · MISLE 28800 · 13 November 2007 · activity 3097419G L 63 Freight Barge · MISLE 42319 · 13 November 2007 · activity 3097419UNCLE PETER Towing Vessel · MISLE 92004 · 13 November 2007 · activity 3097419KOLBI MICHELLE Towing Vessel · MISLE 116018 · 13 November 2007 · activity 3097419G.L. 170 Freight Barge · MISLE 170944 · 13 November 2007 · activity 3097419ADDI GRACE Towing Vessel · MISLE 506261 · 13 November 2007 · activity 3097419

Inspection history · 56

12 May 2026 Deficiency Check · MARPOL Annex I Examination · Annual Inspection
Physical examination · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 8357187
6 March 2025 Internal Structural Exam · Periodic Inspection · Examination of Repairs · Administrative Inspection · Drydock Exam · Deficiency Check
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 8089753
30 August 2024 Deficiency Check · Administrative Inspection
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 7992605
1 July 2024 Deficiency Check · Annual Inspection · In-Service Inspection · Administrative Inspection
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 7946764
18 July 2023 MARPOL Annex VI Survey · Annual Inspection · MARPOL Annex I Examination
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7744673
19 April 2022 MARPOL Annex VI Survey · MARPOL Annex I Examination · MTSA Verification · COI Inspection · Deficiency Check · Administrative Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 7429615
4 January 2022 Administrative Inspection · Drydock Exam · Internal Structural Exam
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 7375294
11 March 2021 In-Service Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 7154435
9 February 2021 MARPOL Annex VI Survey · MARPOL Annex I Examination · Annual Inspection · MTSA/ISPS Verification
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 7138184
6 February 2020 MARPOL Annex VI Survey · Drydock Exam · Internal Structural Exam · Annual Inspection · MARPOL Annex I Examination
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 6903892
6 March 2019 Annual Inspection · MARPOL Annex VI Survey · MARPOL Annex I Examination · Administrative Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 6638726
22 January 2018 MARPOL Annex I Examination · Administrative Inspection · MARPOL Annex VI Survey · Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6341619
25 October 2016 MTSA Verification · Administrative Inspection · COI Inspection · Hull Examination · Internal Structural Exam
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 6029440
12 February 2016 Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 5818362
22 April 2015 Examination of Repairs · Periodic Inspection · Hull Examination · Internal Structural Exam
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 5108413
21 May 2014 Annual Inspection · MTSA Verification
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 4871453
28 December 2011 Administrative Inspection · Drydock Exam · Internal Structural Exam · Examination of Repairs · COI Inspection · MARPOL Annex I Examination · MTSA Verification · MARPOL Annex VI Survey
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 4214980
9 August 2011 Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 4110335
27 April 2010 Administrative Inspection · Annual Inspection · MARPOL Annex VI Survey · Drydock Exam · Examination of Repairs · MARPOL Annex I Examination · Internal Structural Exam
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3730674
14 August 2009 Administrative Inspection · Examination of Repairs · MARPOL Annex I Examination · Annual Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3565131
17 April 2008 MTSA Verification · Annual Inspection
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3186360
30 November 2007 Type not recorded
No type recorded · Marine Safety Unit Galveston · USCG Heartland District (CGD-H) · Activity 3107549
30 November 2007 Type not recorded
No type recorded · Marine Safety Unit Galveston · USCG Heartland District (CGD-H) · Activity 3107562
13 November 2007 Type not recorded
No type recorded · Marine Safety Unit Galveston · USCG Heartland District (CGD-H) · Activity 3097419
16 March 2007 Hull Examination · COI Inspection · Examination of Repairs · Internal Structural Exam
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 2889094
10 January 2006 Security Plan Amendment Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2564112
26 September 2005 Administrative Inspection
Administrative · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 2501809
9 September 2004 Security Plan Amendment Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2190911
13 August 2004 Security Plan Amendment Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2165336
10 August 2004 Examination of Repairs
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 2197956
13 July 2004 MTSA Verification · Periodic Inspection
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 2140538
30 December 2003 Security Plan Review - VSP
Administrative · Commandant (CG-ODO) · Activity 1991734
24 November 2003 Administrative Inspection
Administrative · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1953251
21 October 2003 Examination of Repairs · Internal Structural Exam · Hull Examination
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1856755
2 October 2003 Annual Inspection
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1925373
10 September 2002 Deficiency Check
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1674766
27 June 2002 Re-Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1636918
12 April 2002 Internal Structural Exam · Hull Examination
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1598045
12 June 2001 COI Inspection
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1403412
15 June 2000 Deficiency Check
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 819634
9 May 2000 Deficiency Check
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1050168
15 March 2000 Re-Inspection
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1454781
13 September 1999 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 682723
26 August 1999 Hull Examination
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1365358
22 January 1999 COI Inspection
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1464147
24 June 1998 Deficiency Check
Physical examination · Activities Europe · Activity 793527
30 March 1998 Re-Inspection
Physical examination · Activities Europe · Activity 1438711
13 February 1997 Hull Examination · COI Inspection
Physical examination · Activities Europe · Activity 1354076
15 October 1995 Administrative
Administrative · Activities Europe - OLD · USCG Northeast District (CGD-NE) · Activity 880221
11 October 1994 Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 867470
3 July 1994 Re-Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 863055
27 August 1993 COI Inspection · MARPOL Annex I Examination
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1151410
5 May 1993 Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 834535
21 April 1993 Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1150791
18 March 1993 Examination of Repairs · Hull Examination
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1454000
8 April 1991 Hull Examination
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 926018

Deficiency record · 82

07 - Fire Safety › N/A - No Subsystem › Remote Means of control (opening,pumps,ventilation,etc.) Machinery spaces
Issued 9 May 2025 Resolved
Each power ventilation system for a machinery space must have two controls to stop the ventilation, one of which may be the supply circuit breaker.(b) The controls required in paragraph (a) of this section must be grouped so that they are operable from two positions, one of which must be outside the machinery space. Vessel lacked functioning emergency ventilation shutdown.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 13 May 2025
Resolution: Tested both ventilation shut-downs, all SAT.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 9 May 2025 Resolved
The construction of lights and shapes and the installation of lights on board the vessel must satisfy the Commandant, U.S. Coast Guard. Stern light and running lights were not connected nor visible.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 13 May 2025
Resolution: Vessel connected & energized nav lights, all SAT.
04 - Emergency Systems › N/A - No Subsystem › Fire drills
Issued 9 May 2025 Resolved
Every crewmember must participate in at least one abandon-ship drill and one fire drill every month. The drills of the crew must take place within 24 hours of the vessel leaving a port if more than 25 percent of the crew have not participated in abandon-ship and fire drills on board that particular vessel in the previous month. Vessel lacked records of fire and abandon ship drills.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 13 May 2025
Resolution: Vessel provided records of fire and abandon ship drills.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 9 May 2025 Resolved
Each lifebuoy must be marked in block capital letters with the name of the vessel and the name of the port required to be marked on the stern of the vessel under 67.123 of part 67 of this chapter. 01 lifebuoy was missing vessel name and homeport.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 13 May 2025
Resolution: Vessel marked lifebuoy with vessel name and homeport, all SAT.
09 - Working and Living Conditions › 091 - Living Conditions › Pipes, wires (insulation)
Issued 9 May 2025 Resolved
Piping, including valves, pipe fittings and flanges, conveying vapors, gases or liquids whose temperature exceeds 150 F., shall be suitably insulated where necessary to preclude injury to personnel. The starboard generator’s diesel engine was missing lagging on the exhaust piping.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 13 May 2025
Resolution: Vessel added lagging to starboard generator diesel engine exhaust piping.
01 - Certificates & Documentation › 013 - Documents › Conformance Test Report
Issued 9 May 2025 Resolved
If your vessel's Certificate of Inspection is renewed less often than annually, the marine inspector must check the settings of the safety or relief valves on all pressure vessels, except cargo tanks, twice every 5 years. The relief valves for both starting air receivers have not been tested since 2018.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 13 May 2025
Resolution: Vessel retested relief valves for start air receivers, all SAT.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 9 May 2025 Resolved
A lighting distribution panel must not supply branch circuits rated at over 30 amperes. Circuit breaker supplied branch circuits rated at 50 amps.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 13 May 2025
Resolution: Vessel replaced 50-amp breaker with 30-amp breaker, all SAT.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Gauges, thermometers, etc
Issued 9 May 2025 Resolved
Fuel oil service and transfer, fire, cargo, and boiler feed pumps must be provided with a discharge pressure gauge. Fire pump pressure gauge used was not compatible with the pressure to be indicated.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 13 May 2025
Resolution: Vessel replaced fire pump pressure gauge, all SAT.
14 - Pollution Prevention › 146 - MARPOL Annex VI › Bunker delivery notes
Issued 9 May 2025 Resolved
The bunker delivery note shall be kept on board the ship in such a place as to be readily available for inspection. It shall be retained for a period of three years after the fuel oil has been delivered on board. Vessel lacked bunker delivery notes.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 12 May 2026
Resolution: Bunker notes now stored onboard
14 - Pollution Prevention › 146 - MARPOL Annex VI › Other (MARPOL Annex VI)
Issued 9 May 2025 Resolved
The bunker delivery note shall be accompanied by a representative sample of the fuel oil delivered. The sample is to be sealed and signed by the supplier's representative and the master or officer in charge of the bunker operation and retained under the ship's control until the fuel is substantially consumed, but in any case for a period of not less than 12 months from the time of delivery. Vessel lacked fuel samples.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 12 May 2026
Resolution: Fuel samples now stored onboard
09 - Working and Living Conditions › 091 - Living Conditions › Sanitary Facilities
Issued 9 May 2025 Resolved
All washbasins, showers, and bathtubs shall be equipped with adequate plumbing, including hot and cold running water. All toilets must be installed with adequate plumbing for flushing. Marine Sanitation Device not installed.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 13 May 2025
Resolution: Vessel installed toilet and sink with adequate plumbing.
01 - Certificates & Documentation › 013 - Documents › SOPEP
Issued 9 May 2025 Resolved
Shipboard Oil Pollution Emergency Plan (SOPEP) appendices must include the following information: Twenty-four hour contact information and alternates to the designated contacts. These details must be routinely updated to account for personnel changes and changes in telephone, telex, and telefacsimile numbers. SOPEP plan lacked updated contact information.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 28 May 2025
Resolution: Received updated SOPEP plan, all SAT.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Other (load lines)
Issued 9 May 2025 Resolved
Vessels assigned a load line shall have the deck line and the load line marks permanently scribed or embossed as required by subchapter E (Load Lines) of this chapter. The marks shall be plainly visible and, if necessary, special arrangements shall be made for this purpose. Side fenders restrict visibility of load line marks.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 13 May 2025
Resolution: Side fenders blocking the load line marks were removed, all SAT.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 6 August 2024 Resolved
At least one-half the total number of lifebuoys on the vessel must each be fitted with a self-igniting light approved under approval series 161.010. Lifering buoy floating waterlights did not have the approved batteries. Replace to the satisfaction of the attending USCG Marine Inspector. 46 CFR 96.06 46 CFR 199.70(a)(3)(ii)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 20 August 2024
Resolved 9 August 2024
Resolution: Received photographs and attestation from vsl rep; alkaline batteries have been replace w/ lithium batteries.
09 - Working and Living Conditions › 092 - Working Conditions › Protection machinery
Issued 6 August 2024 Resolved
to minimize fire hazards insofar as is reasonable and practicable. The hydraulic lines for the Port booster pump were not properly supported by a bracket or other means. Repair or replace to the satisfaction of the attending USCG Marine Inspector. 46 CFR 92.05-1
Action required: 16 - Rectify deficiencies w/in 14 days
Due 20 August 2024
Resolved 9 August 2024
Resolution: Received photographs and attestation from vsl rep; hydraulic line bracket all sat.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Machinery space openings
Issued 19 April 2022 Resolved
Each cable installation must meet sections 25, except 25.11, of IEEE 45-2002. Camera wire was run through a watertight bulkhead leading from the pump room to the storage room on the lower deck and did not ensure the watertightness of the compartments. 46 CFR 111.60-5(a)(1)
Action required: 17 - Rectify deficiencies prior to departure
Due 19 April 2022
Resolved 10 May 2022
Resolution: Vessel secured watertight penetration with approved watertight fitting.
07 - Fire Safety › N/A - No Subsystem › Remote Means of control (opening,pumps,ventilation,etc.) Machinery spaces
Issued 19 April 2022 Resolved
Valves installed on the outside of the oil tanks must be arranged with a means of manual control locally at the valve and remotely from a readily accessible and safe location outside of the compartment in which the valves are located. The fuel reach rod on the main deck day tank was not operational. 46 CFR 56.50.60(d)(1)
Action required: 17 - Rectify deficiencies prior to departure
Resolved 26 April 2022
Resolution: Reach rod for the main deck day tank repaired and tested properly.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 19 April 2022 Resolved
All fuel pipes, pipe connections, and accessories shall be readily accessible, and effectively secured against excessive movement and vibration. The fuel oil piping and strainers for the generators were not secured to prevent vibrations and excessive movement. 46 CFR 56.50-75(b)(3) 46 CFR 56.50-70(b)(1)
Action required: 17 - Rectify deficiencies prior to departure
Resolved 26 April 2022
Resolution: Fuel oil piping and strainers for the generators properly secured.
09 - Working and Living Conditions › 092 - Working Conditions › Guards - fencing around dangerous machinery parts
Issued 19 April 2022 Resolved
Gears, couplings, flywheels and all machinery capable of injuring personnel shall be provided with adequate covers or guards. Both generators had exposed belts for auxiliary pumps that were not suitable guarded. 46 CFR 58.01-20
Action required: 17 - Rectify deficiencies prior to departure
Resolved 26 April 2022
Resolution: Covers were provided for the generators exposed belts.
09 - Working and Living Conditions › 092 - Working Conditions › Guards - fencing around dangerous machinery parts
Issued 19 April 2022 Resolved
Piping, including valves, pipe fittings and flanges, conveying vapors, gases or liquids whose temperature exceeds 150 F., shall be suitably insulated where necessary to preclude injury to personnel. The #1 gen's exhaust was missing approximately 2 feet of lagging. 46 CFR 56.50-1(k)
Action required: 17 - Rectify deficiencies prior to departure
Resolved 26 April 2022
Resolution: Exhaust lagging for the #1 generator was replaced.
07 - Fire Safety › N/A - No Subsystem › Fire-dampers
Issued 19 April 2022 Resolved
Where natural ventilation is provided for spaces protected by a carbon dioxide extinguishing system, provisions shall be made for easily and effectively closing off the ventilation. The paint locker's goose neck vent did not have a vent closure. 46 CFR 95.15-35(b)
Action required: 17 - Rectify deficiencies prior to departure
Resolved 26 April 2022
Resolution: Paint locker's goose neck vent now has an installed closure device.
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 19 April 2022 Resolved
Materials used in piping systems must be selected from the specifications that appear in this section. The fire main had a pinhole leak in the elbow bend of the piping directly after the discharge side of the main fire pump. 46 CFR 56.60-1(a)(2)
Action required: 17 - Rectify deficiencies prior to departure
Resolved 26 April 2022
Resolution: Elbow bend in fire main was cropped and renewed by Conrad Shipyard and tested to 150 psi in presence of marine inspector.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 19 April 2022 Resolved
Each fire hydrant shall be identified in red letters and figures at least two inches high "FIRE STATION NO. 1,""2,""3," etc. There were multiple fire hydrants that were not properly labeled with the fire station number. 46 CFR 97.37-15(a)
Action required: 17 - Rectify deficiencies prior to departure
Resolved 26 April 2022
Resolution: Fire hydrants were properly labeled.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 19 April 2022 Resolved
Each battery tray must be chocked with wood strips or their equivalent to prevent movement. The starting batteries for the #1 generator were not secured from movement. 46 CFR 111.15-5(d)
Action required: 10 - Deficiency Rectified
Resolved 19 April 2022
Resolution: Prior to the completion of the inspection, vessel representatives secured the batteries in the container.
14 - Pollution Prevention › 141 - MARPOL Annex I › Standard discharge connection
Issued 19 April 2022 Resolved
All ocean going ships of 400 gross tons and above must have a standard shore connection for reception facilities to discharge oily mixtures from machinery space bilges. There was not a standard discharge connection on board the vessel. Provide a permanent connection or portable adapter that meets the standard found in 46 CFR 155.430(a)(1)-(6) and also given via email to the vessel representative. 46 CFR 155.430(a)
Action required: 17 - Rectify deficiencies prior to departure
Resolved 26 April 2022
Resolution: Standard discharge connection was manufactured by shipyard and now located main deck starboard side.
14 - Pollution Prevention › 146 - MARPOL Annex VI › Bunker delivery notes
Issued 19 April 2022 Resolved
Details of fuel oil for combustion purposes delivered to and used on board shall be recorded by means of a bunker delivery note that shall contain at least the information specified in appendix V to this Annex. The bunker delivery notes on board did not contain: Density at 15 C, kg/m3; Sulphur content (% m/m); and a declaration signed and certified by the supplier's representative that the fuel supplied is in conformity with conformity with regulation 14.1 or 14.4 and 18.3. MARPOL (2011)VI Reg. 18.5
Action required: 17 - Rectify deficiencies prior to departure
Due 19 April 2022
Resolved 6 August 2024
Resolution: Reviewed bunker deliver notes; def is over 2yrs old and vsl complies with IMO/MARPOL regs.
01 - Certificates & Documentation › 013 - Documents › Oil record book
Issued 19 April 2022 Resolved
Each operation described in paragraphs (d), (e), and (f) of this section shall be fully recorded without delay in the Oil Record Book so that all the entries in the book appropriate to that operation are completed. Entries in the ORB were being completed for a tank vessel and not machinery operations. This does not ensure all required items are being properly recorded. 33 CFR 151.25(h)
Action required: 10 - Deficiency Rectified
Resolved 19 April 2022
Resolution: Provided guidance on properly filling out an oil record book to barge's PIC for oil transfers.
Engineering › Fuel Oil Service System › Piping
Issued 23 January 2018 Resolved
2 mounting brackets for high pressure fuel lines were missing on the No.1 Generator
Action required: 705 - Other - as specified
Due 30 January 2018
Resolved 24 January 2018
Resolution: New brackets installed
Engineering › Fuel Oil Storage/Transfer System › Manifold
Issued 23 January 2018 Resolved
2 valves leaking diesel on fuel transfer manifold.
Action required: 705 - Other - as specified
Due 30 January 2018
Resolved 24 January 2018
Resolution: O-rings in Valves replaced
Fire Fighting › Fire Main › Condition
Issued 23 January 2018 Resolved
Firemain had multiple pinholes in it that had been clad welded.
Action required: 705 - Other - as specified
Due 28 February 2018
Resolved 27 February 2018
Resolution: New section of pipe installed, tested via charging line with fire main pressure of over 100 psi, no leaks detected.
Engineering › Fuel Oil Service System › Hose
Issued 23 January 2018 Resolved
Fuel hoses greater the 30" (approx. 10ft) were installed on both generators for supply and return from fuel filters.
Action required: 705 - Other - as specified
Due 28 February 2018
Resolved 27 February 2018
Resolution: Hard piping installed.
Electrical › Electrical Distribution System (service) › Ground Indicator
Issued 23 January 2018 Resolved
Ground Indicator inop on switchboard.
Action required: 705 - Other - as specified
Due 30 January 2018
Resolved 24 January 2018
Resolution: Bulb was burnt out and replaced
Engineering › Bilge Water Management System › Strainer
Issued 23 January 2018 Resolved
No strainer was on bilge suction in engine room.
Action required: 705 - Other - as specified
Due 28 February 2018
Resolved 28 February 2018
Resolution: Proper strainer installed.
Lifesaving › Inflatable Liferafts › Float Free
Issued 23 January 2018 Resolved
Liferaft was installed incorrectly with the weak link tied off to the handrail and not the weak link so it would not float free.
Action required: 705 - Other - as specified
Due 23 January 2018
Resolved 23 January 2018
Resolution: Corrected on spot
Documentation › Logs/Records › Oil Record Book
Issued 23 January 2018 Resolved
(C) code entries in the oil record book have not been made in over 7 years.
Action required: 705 - Other - as specified
Due 31 March 2019
Resolved 24 February 2021
Resolution: Vsl rep provided evidence in the form of photographs of current entries in the ship's ORB.
Fire Fighting › Emergency Fire Pumps › Power Source
Issued 12 February 2016 Resolved
Emergency fire pump was inoperable and did not provide pressure to the system.
Action required: 705 - Other - as specified
Due 26 February 2016
Resolved 17 February 2016
Resolution: Emergency fire pump was fixed and operated correctly.
Electrical › Electrical Distribution System (service) › Switchboard
Issued 12 February 2016 Resolved
Switchboard had a cut-out in it that had been covered over with cardboard and painted the color of the switchboard. Required that a permanent repair be inserted into the switchboard to cover the opening.
Action required: 705 - Other - as specified
Due 26 February 2016
Resolved 17 February 2016
Resolution: A permanent plate was installed on switchboard and the issue was corrected.
Fire Fighting › Fixed CO2 Fire Extinguishing System › Servicing
Issued 12 February 2016 Resolved
Installed fixed CO2 hose reel had been dismantled after it was serviced. Required that it was recertified by a technician after the system had been put back together.
Action required: 705 - Other - as specified
Due 26 February 2016
Resolved 17 February 2016
Resolution: System was recertified and a new certification certificate was issued to the vessel.
Documentation › Safety/Response Plans/Programs › Vessel Response Plan
Issued 17 April 2008 Resolved
Provide proof that a Non-Tank Vessel Response Plan has been submitted to CG HQ.
Action required: 705 - Other - as specified
Due 17 May 2008
Resolved 25 April 2008
Resolution: Issued in error.
Fire Fighting › Portable CO2 Fire Extinguisher › Service
Issued 13 July 2004 Resolved
Fire extinguishing equipment due for annual servicing. Provide service certificate.
Due 30 July 2004
Resolved 10 August 2004
Resolution: The following CG-835 dated on 13july04 from activity 2140538 was cleared to the satisfaction of the attending Coast Guard inspector.
Electrical › Electric Generation Source (service) › Generator
Issued 13 July 2004 Resolved
Prove proper operation of generator safety trips - overspeed and high temp prior to using system. #1 Generator electical overspeed did not actuate shutdown. Temperature bath @ 212 F did not cause high temp shutdown.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 10 August 2004
Resolved 10 August 2004
Resolution: The following CG-835 dated on 13july04 from activity 2140538 was cleared to the satisfaction of the attending Coast Guard inspector.
Electrical › Electric Generation Source (service) › Generator
Issued 13 July 2004 Resolved
Flexible joints on generator #1 & #2 exhausts are both wasted. Replace flex joints.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 10 August 2004
Resolution: The following CG-835 dated on 13july04 from activity 2140538 was cleared to the satisfaction of the attending Coast Guard inspector.
Fire Fighting › Fire Main › Valves
Issued 13 July 2004 Resolved
Replace frozen fire main valve on the starboard side upper deck.
Condition: Improper/Lack of Maintenance
Due 30 July 2004
Resolved 10 August 2004
Resolution: The following CG-835 dated on 13july04 from activity 2140538 was cleared to the satisfaction of the attending Coast Guard inspector.
Fire Fighting › Fire Pumps › Gears
Issued 13 July 2004 Resolved
#2 fire pump needs gear box aft oil seal to be replaced. Pipe wrench needed to be used to get the pump running. Repair prior to operating booster.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 10 August 2004
Resolved 10 August 2004
Resolution: The following CG-835 dated on 13july04 from activity 2140538 was cleared to the satisfaction of the attending Coast Guard inspector.
Engineering › Diesel Engine (auxiliary) › Air Silencer
Issued 13 July 2004 Resolved
#2 generator exhaust muffler wasted and leaking excessively. Replace unit.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 30 July 2004
Resolved 10 August 2004
Resolution: The following CG-835 dated on 13july04 from activity 2140538 was cleared to the satisfaction of the attending Coast Guard inspector.
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 13 July 2004 Resolved
Replace wiring to the navigation lights and prove proper operation.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 30 July 2004
Resolved 10 August 2004
Resolution: The following CG-835 dated on 13july04 from activity 2140538 was cleared to the satisfaction of the attending Coast Guard inspector.
Fire Fighting › Firemans Outfit › Axe
Issued 13 July 2004 Resolved
Replace fire ax.
Condition: Design Flaw
Action required: 705 - Other - as specified
Due 30 July 2004
Resolved 10 August 2004
Documentation › Logs/Records › Oil Record Book
Issued 13 July 2004 Resolved
Oil record book not maintained properly. Transfer records to oil record book and maintain.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 30 July 2004
Resolved 10 August 2004
Resolution: The following CG-835 dated on 13july04 from activity 2140538 was cleared to the satisfaction of the attending Coast Guard inspector.
Construction/Loadline › Structures › Superstructure
Issued 2 October 2003 Resolved
Deck house wasted with visible light coming through near the #2 generator.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 17 October 2003
Resolved 28 June 2004
Resolution: Repaired deckhouse.
Navigation
Issued 25 July 2003 Resolved
Secure the portable nav. battery box.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 12 September 2003
Resolved 1 September 2003
Resolution: New nav battery boxes installed.
Engineering › Diesel Engine (propulsion-electric)
Issued 25 July 2003 Resolved
Repair the service generator over temp shutdown.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 12 September 2003
Resolved 29 September 2003
Resolution: displayed proper shutdown for high temp during inspection.
Fire Fighting › Fire Pumps
Issued 25 July 2003 Resolved
Repair packing at the fire main (excessive leakage). LEGACY COMPONENT DESC: Gland Sealing
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 12 September 2003
Resolved 1 September 2003
Resolution: Packing replaced and not leaking during operation of pump.
Fire Fighting › Fire Main
Issued 25 July 2003 Resolved
Repair ruptured fire main at main pump foundation.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 12 September 2003
Resolved 1 September 2003
Resolution: Wasted sections replaced.
Fire Fighting › Fire Main
Issued 25 July 2003 Resolved
Replace pressure gauge at fire main pump. LEGACY COMPONENT DESC: Pressure
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 12 September 2003
Resolved 1 September 2003
Resolution: Pressure gauge replaced.
Operations/Management › Cargo Transfer/Lightering
Issued 27 June 2002 Resolved
Provide Person in Charge (PIC) designation letter to marine inspector. LEGACY COMPONENT DESC: Person in Charge Presence/Supervision
Due 27 July 2002
Resolved 11 September 2002
Resolution: BARGE ENGINEER.
Construction/Loadline › Structures
Issued 27 June 2002 Resolved
Repair first step at forward upper deck ladder. LEGACY COMPONENT DESC: Ladder
Condition: Unknown
Due 27 July 2002
Resolved 11 September 2002
Electrical › Electric Generation Source (service)
Issued 27 June 2002 Resolved
Demonstrate overspeed and low lube shutdowns for Motor Generator 1 and 2 to marine inspector.
Due 27 July 2002
Resolved 11 September 2002
Resolution: LOW LUBE OIL AND OVERSPEED TRIP SATISFACTORY OPERATION FOR GENERATOR PRIME MOVERS.
Electrical
Issued 12 June 2001 Resolved
REPLACE STAND OFFS FOR ELECTRICAL WIRING FOR TOP DECK FLOOD LIGHTS.
Condition: Unknown
Due 29 June 2001
Resolved 29 June 2001
Accommodation/Occupational Safety
Issued 12 June 2001 Resolved
REPLACE BOTTOM COURSE OF STEEL CABLE HAND RAIL ON FWD PORT SIDE QUARTER, AFT OF FWD MOORING BIT.
Condition: Unknown
Due 29 June 2001
Resolved 29 June 2001
Fire Fighting
Issued 15 March 2000 Resolved
Have all portable fire extinguishers serviced.
Condition: Unknown
Due 17 March 2000
Resolved 3 April 2000
Construction/Loadline
Issued 15 March 2000 Resolved
Free up all closure devices on aft port and starboard ventilation blower covers; replace hex nuts with wing nuts.
Condition: Unknown
Due 15 March 2000
Resolved 15 March 2000
Lifesaving
Issued 15 March 2000 Resolved
Replace expired pyrotechnics.
Condition: Unknown
Due 15 March 2000
Resolved 15 March 2000
Fire Fighting
Issued 15 March 2000 Resolved
Replace portable fire extinguisher #2 in accordance with Safety Plan or update Plan with extinguisher's new location.
Condition: Unknown
Due 15 March 2000
Resolved 15 March 2000
Lifesaving
Issued 15 March 2000 Resolved
Renew vessel's name and homeport on ring buoys.
Condition: Unknown
Due 15 March 2000
Resolved 15 March 2000
Lifesaving
Issued 15 March 2000 Resolved
Properly position liferaft in cradle.
Condition: Unknown
Due 15 March 2000
Resolved 15 March 2000
Navigation
Issued 15 March 2000 Resolved
Paint all navigational running light screens flat black._x001C_ _x001C_
Condition: Unknown
Due 15 March 2000
Resolved 15 March 2000
Fire Fighting
Issued 15 March 2000 Resolved
Stencil / mark vessel's name on fire axe.
Condition: Unknown
Due 15 March 2000
Resolved 15 March 2000
Accommodation/Occupational Safety
Issued 15 March 2000 Resolved
Affix chain 9 inches above deck at port side embarkation handrail opening.
Condition: Unknown
Due 15 March 2000
Resolved 15 March 2000
Accommodation/Occupational Safety
Issued 15 March 2000 Resolved
Weld broken rung on ladder leading to pump room.
Condition: Unknown
Due 15 March 2000
Resolved 15 March 2000
Navigation
Issued 15 March 2000 Resolved
Replace burnt out lamp in top dredging light.
Condition: Unknown
Due 15 March 2000
Resolved 3 April 2000
Electrical
Issued 15 March 2000 Resolved
Repair emergency light on starboard side top deck exterior._x001C_ _x001C_
Condition: Unknown
Due 15 March 2000
Resolved 15 March 2000
Electrical
Issued 15 March 2000 Resolved
Replace burnt out forward bulb in interior emergency light fixture on athwartship port side watertight door.
Condition: Unknown
Due 15 March 2000
Resolved 15 March 2000
Engineering
Issued 15 March 2000 Resolved
Clean fuel tank vent flame screens.
Condition: Unknown
Due 15 March 2000
Resolved 15 March 2000
Engineering
Issued 15 March 2000 Resolved
Blank off oily water separator overboard discharge line.
Condition: Unknown
Due 15 March 2000
Resolved 15 March 2000
Documentation
Issued 15 March 2000 Resolved
Provide on board approved SOEPE.
Condition: Unknown
Due 15 March 2000
Resolved 15 March 2000
Construction/Loadline
Issued 15 March 2000 Resolved
Adjust and demonstrate operation/seal of starboard side athwartship weathertight door._x001C_ _x001C_
Condition: Unknown
Due 15 March 2000
Resolved 15 March 2000
Construction/Loadline
Issued 15 March 2000 Resolved
Tighten packing gland, eliminate excessive water leakage from Gould ballastpump.
Condition: Unknown
Due 15 March 2000
Resolved 15 March 2000
Documentation
Issued 26 August 1999 Resolved
Vessel Internal Structural and Drydock exam was due on 13JUL99. Vessel was not in the drydock until 15AUG99. CG Inspector asked why the vessel was possibly operating past drydock due dates. Port engineer [name withheld] saidthe vessel was late because it was operating on ship channel dredging ops.
Condition: Unknown
Due 7 September 1999
Resolved 12 September 1999
Documentation
Issued 30 March 1998 Resolved
Provide documentation of completion of assignment of the type "B" freeboardDual Loadline.
Condition: Unknown
Due 30 March 1998
Resolved 30 March 1998
Documentation
Issued 13 February 1997 Resolved
Resolve issue of Type B "reduced" loadline vs "unmanned" restriction on loadline certificate as detailed in EURMI letter to Great Lakes of 21FEB97.
Condition: Unknown
Due 13 February 1997
Resolved 13 February 1997
Documentation
Issued 3 July 1994 Resolved
PROVIDE PROOF OF VALID LOADLINE PROVISIONAL EXPIRED JAN 94.
Condition: Unknown
Due 4 August 1994
Resolved 9 August 1994
Deck/Cargo
Issued 18 March 1993 Resolved
Provide a P.E. Report (Professional Engineer) on air receiver pressure vessels as required by 46 CFR 54.01-5(e).
Condition: Unknown
Due 18 March 1993
Resolved 18 March 1993

Source. US Coast Guard records through 23 August 2026, retrieved 5 September 2026. Vessels the Coast Guard classes as Barge or Towing Vessel. Coverage and known gaps.