MAURY USCG vessel records
← All vessels

DOUBLE SKIN 54

DOUBLE SKIN 54 is a 2005 tank barge. The Coast Guard has recorded 53 inspections since 2005, most recently in January 2026, along with 13 deficiencies — 1 with no resolution recorded — and 5 casualty investigations between 2007 and 2022.

Records from 2005 to 2026. Most recent: inspection, 15 January 2026.

Built
2005
Last inspected
15 January 2026
Documentation
Valid · documentation file of 10 August 2026
Controls
None recorded without a removal date

Identity

WDC6622
729469
Flag
UNITED STATES
Maury page id
psix-729469

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Barge class in Maury's sources begin in 1972.

Inspections, by type

…with no type recorded12
Years with a record 21 calendar years (2005–2026)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. The counts in the strip above are the same counts; this table splits the inspections by the kind of activity recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Documentation record

Registered dimensions (L × B × D)348.0 ft × 62.0 ft × 24.5 ft
Registered tonnagegross 4,235 / net 2,307
ITC dimensions (L × B × D)348.0 ft × 62.0 ft × 24.5 ft
ITC tonnagegross 4,235 / net 2,307
BuilderJEFFBOAT LLC · JEFFERSONVILLE, IN, UNITED STATES · built 2005
Hull materialSteel
PropulsionUNSPECIFIED
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing portBALTIMORE, MD
Trade endorsementsCoastwise, unrestricted, Registry
DocumentationValid · issued 17 November 2025 · expires 31 October 2026
Service, as the file records itTank Barge
Hull formbarge (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it4235 - Convention (Subpart B), Gross Ton
2307 - Convention (Subpart B), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Vessel history report
Every record for this hull, in one document — $299

What it gives that this page does not: the whole record in one dated, citable document — every line with its Coast Guard activity id, the retrieval date on the cover, built to print to PDF with its page breaks — that a surveyor can attach and a lender can file. The same facts as this page, complete and in one file.

Every recorded inspection, 1972 to 2026 for this class, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

A request, not a checkout: leave an email and Maury replies once, with the dated document for this hull and a Stripe invoice for $299. Nothing is charged before the document is in your hands.

Inspected as a tow unit · 4

The Coast Guard recorded this vessel and the following in the same inspection activity — normally a tug and the barges in its tow. A recreational or unclassed hull in the same activity is held and not published, so it does not appear here: these lists are a floor, not a complete manifest.

RV ENDEAVOR Research Vessel · MISLE 228893 · 17 January 2022 · activity 7382503FORT SCHUYLER Towing Vessel · MISLE 1322230 · 12 July 2019 · activity 6752248DELAWARE Towing Vessel · MISLE 1395329 · 5 March 2018 · activity 6370611WICOMICO Towing Vessel · MISLE 792670 · 22 August 2007 · activity 3037147

Inspection history · 53

15 January 2026 Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 8296767
21 November 2025 Bulk Liquid Transfer Monitor
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 8272133
29 March 2025 Bulk Liquid Transfer Monitor
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 8101774
9 January 2025 Deficiency Check · Periodic Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 8060228
7 November 2023 MTSA Verification · Internal Structural Exam · Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7821250
10 August 2023 Damage Survey
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7765625
11 April 2023 MTSA Verification · Deficiency Check · Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7665946
17 January 2022 Type not recorded
No type recorded · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7382503
16 November 2021 Examination of Repairs · Drydock Exam · Internal Structural Exam · COI Inspection · Cargo Tank Internal · MTSA Verification · Deficiency Check
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7345462
2 November 2021 Administrative Inspection
Administrative · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7344200
23 April 2020 Administrative Inspection
Administrative · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6942981
12 July 2019 Type not recorded
No type recorded · Marine Safety Unit New Bedford · USCG Northeast District (CGD-NE) · Activity 6752248
21 May 2019 Annual Inspection · MTSA Verification
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6689384
4 September 2018 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 6531352
8 June 2018 Periodic Inspection · MTSA Verification
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6437752
9 March 2018 Damage Survey
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6371211
5 March 2018 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 6370611
9 November 2017 Internal Structural Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6303845
17 April 2017 MTSA Verification · Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6126763
2 May 2016 MTSA Verification · Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 5864804
2 March 2016 Administrative Inspection
Administrative · Sector Delaware Bay · USCG East District (CGD-E) · Activity 5860305
8 January 2016 Type not recorded
No type recorded · Sector Boston · USCG Northeast District (CGD-NE) · Activity 5793669
28 September 2015 Deficiency Check
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 5730361
26 August 2015 Administrative Inspection
Administrative · Sector Delaware Bay · USCG East District (CGD-E) · Activity 5227014
12 June 2015 COI Inspection · SIP Inspection/Audit · MTSA Verification
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 5147831
19 May 2015 Cargo Tank Internal · Internal Structural Exam · Drydock Exam
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 5135603
12 August 2014 SIP Inspection/Audit · MTSA Verification · Annual Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 4953738
2 June 2014 Type not recorded
No type recorded · Sector Boston · USCG Northeast District (CGD-NE) · Activity 4876809
3 September 2013 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 4705943
6 August 2013 MTSA Verification · SIP Inspection/Audit · DAPI Audit
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 4676514
30 November 2012 Internal Structural Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 4493312
22 October 2012 Administrative Inspection
Administrative · Sector Delaware Bay · USCG East District (CGD-E) · Activity 4469301
26 June 2012 SIP Inspection/Audit · MTSA Verification
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 4357295
6 June 2011 Annual Inspection · SIP Inspection/Audit · MTSA Verification
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 4044210
3 June 2010 DAPI Audit · COI Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 3756399
2 June 2010 Internal Structural Exam · Cargo Tank Internal · Hull Examination
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 3740667
24 March 2010 Type not recorded
No type recorded · Sector Delaware Bay · USCG East District (CGD-E) · Activity 3702782
19 March 2010 Administrative Inspection
Administrative · Sector Delaware Bay · USCG East District (CGD-E) · Activity 3698724
27 May 2009 SIP Inspection/Audit · Annual Inspection · MTSA Verification
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 3487208
7 May 2009 Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 3474215
8 April 2009 Administrative Inspection
Administrative · Sector Delaware Bay · USCG East District (CGD-E) · Activity 3448950
7 April 2009 Type not recorded
No type recorded · Sector Delaware Bay · USCG East District (CGD-E) · Activity 3447943
25 September 2008 Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 3332382
6 August 2008 SIP Inspection/Audit · Annual Inspection · MTSA Verification
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 3290487
6 December 2007 SIP Initial Entry
Administrative · Sector Delaware Bay · USCG East District (CGD-E) · Activity 3176063
2 November 2007 Internal Structural Exam
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 3091802
22 August 2007 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 3037147
8 May 2007 Annual Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 2925086
8 May 2007 SIP Initial Entry
Administrative · Sector Delaware Bay · USCG East District (CGD-E) · Activity 3176003
12 July 2006 SIP Initial Entry
Administrative · Sector Delaware Bay · USCG East District (CGD-E) · Activity 3175937
8 June 2006 Annual Inspection · MTSA Verification
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 2673663
12 May 2005 Cargo Tank Internal · Initial Certification · Internal Structural Exam · Hull Examination
Physical examination · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 2397342
19 April 2005 Security Plan Review - ASP
Administrative · Marine Safety Center (MSC) · Activity 2337687

Deficiency record · 13

06 - Cargo Operations Including Equipment › N/A - No Subsystem › Other (cargo)
Issued 15 January 2026 Resolved
In tank vessels carrying Grade A, B, C, or D liquid cargo, cargo pumps shall be isolated from source of vapor ignition by gastight bulkheads. 46 CFR 32.60-20 PORT CARGO PUMP: Observed misaligned seal on forward bulkhead penetration.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 26 January 2026
Resolution: Renewed gasket/seal. All sat.
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Other (cargo)
Issued 9 January 2025 Resolved
All piping, values, and fittings shall meet the applicable requirements of subchapter F (Marine Engineering). Port cargo pump prime mover water hose exhibits excessive wear; To repair and replace. Port cargo pump prime mover has plastic bowl around fuel filter; To replace with metal bowl.
Action required: 705 - Other - as specified
Resolved 10 January 2025
Resolution: Fuel filter bowl and plug were replace with metal.
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Cargo operation
Issued 7 November 2023 No resolution recorded
Cargo tanks in which Grade A, B, or C liquids are to be transported shall be fitted with either individual pressure-vacuum (P/V) relief valves or shall be fitted with a venting system consisting of branch vent lines connected to a vent header and be fitted with a pressure-vacuum relief valve. The port side slop tank was fitted with an additional goose neck vent underneath it's P/V valve, not consistent with the vessel's branch diagram. Make appropriate modifications to return venting arrangement for the slop tank back to the configuration of the original drawings. Rectify prior to using the port side slop tank.
Action required: 705 - Other - as specified
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 10 August 2023 Resolved
Crop and renew inset on starboard bow with a 24" x 24" insert plate. Provide USCG with ABS report on satisfactory back-gouge inspection. USCG shall inspect final weld and witness NDT.
Action required: 60 - Rectify deficiencies prior to movement
Resolved 14 August 2023
Resolution: Witnessed satisfactory NDT and inspected final weld. All sat.
09 - Working and Living Conditions › 092 - Working Conditions › Holds and tanks safety
Issued 11 April 2023 Resolved
All tank vessels, except unmanned tank barges, contracted for on or after July 1, 1969, shall have efficient guard rails or bulwarks on decks and bridges. All rails shall consist of solid or tubular sections or chains or wire rope or a combination thereof. Port Bow railings were found broken off and bent. Route restricted to Lakes, Bays and Sounds.
Condition: Damaged By Earlier Event
Action required: 16 - Rectify deficiencies w/in 14 days
Due 25 April 2023
Resolved 25 April 2023
Resolution: Recieved proof handrails have been fixed.
02 - Structural Conditions › N/A - No Subsystem › Cargo pumproom
Issued 11 April 2023 Resolved
On all tank vessels, the construction or conversion of which is started on or after November 10, 1936, the cargo pumps shall be designed and installed to minimize the danger of sparking. Special care shall be exercised in the design of packing spaces in order to secure ample depth and accessibility of glands. Where cargo pump shafts pierce gas tight bulkheads, stuffing boxes with readily accessible gas tight glands shall be provided. Observed wasted gaskets on both Port and STBD shaft seals of cargo pumps that allowed air to pass from the hazardous zone into the non-hazardous rated space. Cargo restricted to D/E cargo.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 25 April 2023
Resolved 12 April 2023
Resolution: Replaced cargo pump shaft seal on both pumps.
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 11 April 2023 Resolved
Grounded neutral and high-impedance grounded neutral alternating current systems must have a suitably sensitive ground detection system which indicates current in the ground connection, is able to withstand the maximum available fault current without damage, and provides continuous indication of circuit status to ground. A provision must be included to compare indications under fault conditions with those under normal conditions. Ground detection lighting was found extinguished.
Condition: Design Flaw
Action required: 16 - Rectify deficiencies w/in 14 days
Due 25 April 2023
Resolved 12 April 2023
Resolution: Replaced bulbs. All Sat.
07 - Fire Safety › N/A - No Subsystem › Division - decks, bulkheads and penetrations
Issued 21 May 2019 Resolved
Where cargo pump shafts pierce gastight bulkheads, gastight glands shall be provided. #1 cargo pump shaft gland is deteriorated and no longer gastight. Make proper repairs to the satisfaction of the attending Marine Inspector prior to carrying cargoes other than Diesel, and within 14 days.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 June 2019
Resolved 31 May 2019
Resolution: Crew replaced shaft gland with new
11 - Life Saving Appliances › N/A - No Subsystem › Stowage and provision of liferafts
Issued 21 May 2019 Resolved
Each cargo vessel must carry liferafts stowed in a position providing for easy side-to-side transfer at a single open deck level, or with an aggregate capacity on each side sufficient to accommodate the total number of persons on board. Life raft is stored on top of accommodation structure and is unable to be moved from side-to-side.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 20 June 2019
Resolved 17 June 2019
Resolution: Life raft moved to main deck just forward of notch allowing for side-to-side transfer.
14 - Pollution Prevention › 144 - MARPOL Annex IV (Not Applicable to PSC Exams conducted in the U.S.) › Sewage treatment plant
Issued 21 May 2019 Resolved
No person may operate any vessel equipped with installed toilet facilities unless it is equipped with an operable type II or III device that is labeled under 159.16 or is certified under 159.12 or 159.12a Vessel could not provide proof of MSD certification. Provide proof of USCG certification for MSD currently installed.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 June 2019
Resolved 31 May 2019
Resolution: Vesel rep provided system label with USCG approval.
Construction/Loadline › Hull › Hull Plating
Issued 9 March 2018 Resolved
Conduct repairs to satisfaction of attending marine inspector.
Condition: Damaged By Earlier Event
Action required: 701 - Prior to carriage of passengers/cargo
Due 9 March 2018
Resolved 9 March 2018
Resolution: Satisfactory repairs completed.
Lifesaving › Line-Throwing Appliances › Projectiles
Issued 11 June 2013 Resolved
Line throwing rocket expired.
Due 12 June 2013
Resolved 12 June 2013
Resolution: New rocket provided to vessel.
Construction/Loadline › Hull › Stiffener
Issued 30 November 2012 Resolved
#2S; 3rd SSS from aft, 3rd SSL from bottom, V/W in 2 places as marked; C/R damaged area; provide repair proposal when going into next drydock. Repairs are required to be completed at next drydock.
Action required: 705 - Other - as specified
Due 31 May 2015
Resolved 12 June 2015
Resolution: Cleared in drydock.

Casualty record · 5

22 August 2007Routine · role: Transiting Vicinity of Primary Subject · activity 3037147
24 March 2010Routine · role: Involved in a Marine Casualty · serious marine incident, as classified · 1 injured · activity 3702782
5 March 2018Routine · role: Involved in a Marine Casualty · activity 6370611
12 July 2019Routine · role: Source Vessel for Cargo Transfer · activity 6752248
17 January 2022Routine · role: Involved in a Marine Casualty · activity 7382503
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.