Records from 1993 to 2023. Most recent: inspection, 13 October 2023.
Inspection history · 32
13 October 2023
MTSA Verification · Deficiency Check · Annual Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7807965
17 October 2022
Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7592729
15 September 2022
Annual Inspection · Deficiency Check
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7548157
21 July 2022
Examination of Repairs
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7512654
8 October 2021
Type not recorded
No type recorded · Station Freeport · USCG Heartland District (CGD-H) · Activity 7329769
3 September 2021
Deficiency Check
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 7303555
21 April 2021
Administrative Inspection · Examination of Repairs · Initial Certification
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7179778
15 November 2016
Type not recorded
No type recorded · Station Marathon · USCG Southeast District (CGD-SE) · Activity 6041815
15 November 2016
Type not recorded
No type recorded · Sector Key West · USCG Southeast District (CGD-SE) · Activity 6046025
9 November 2012
Industry Initiated Exam · DAPI Audit
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 4495294
1 August 2012
Industry Initiated Exam · DAPI Audit
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 4424777
2 November 2011
Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 4181512
8 December 2008
Type not recorded
No type recorded · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 3391019
31 October 2003
Type not recorded
No type recorded · Station Lake Worth Inlet · USCG Southeast District (CGD-SE) · Activity 1954710
16 December 2002
Type not recorded
No type recorded · MSO WILMINGTON · USCG East District (CGD-E) · Activity 1719722
23 September 2001
Type not recorded
No type recorded · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 163187
11 March 2001
Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 78292
10 February 2001
Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 68607
18 December 2000
Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 52897
14 December 2000
Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 41198
14 December 2000
Type not recorded
No type recorded · Station Fort Pierce · USCG Southeast District (CGD-SE) · Activity 1515262
25 February 2000
Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 17410
2 July 1999
Uninspected Towing Vessel
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1089006
22 December 1998
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 166509
4 August 1997
Type not recorded
No type recorded · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 139383
8 April 1997
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 164668
8 November 1994
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 680851
22 September 1994
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 98501
8 June 1994
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 53522
28 January 1994
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 680852
4 November 1993
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 143095
4 November 1993
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 231959
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 13 October 2023
Resolved
Machinery and electrical systems must be designed and maintained to provide for safe operation of the towing vessel and safety of persons onboard under normal and emergency conditions. The hydraulic line near the pump showed evidence of leaking.
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Due 2 November 2023
Resolved 13 November 2023
Resolution: Replaced lines and renewed thread tape
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Gauges, thermometers, etc
Issued 13 October 2023
Resolved
The following systems must be equipped with gauges at the machinery location: (2) Main engine cooling water temperature. Main engine cooling water temp gauge was not functioning.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 16 November 2023
Resolved 13 November 2023
Resolution: Replaced gauge
01 - Certificates & Documentation › 013 - Documents › Signs, indications
Issued 13 October 2023
Resolved
Each EAP education program must include at least the following elements: display and distribution of informational material; display and distribution of a community service hot-line telephone number for crewmember assistance, and display and distribution of the employer's policy regarding drug and alcohol use in the workplace. Signage was not posted.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 16 November 2023
Resolved 13 November 2023
Resolution: Sign was hung up with other signs
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 13 October 2023
Resolved
The alcohol testing of each individual must be conducted within 2 hours of when the SMI occurred, unless precluded by safety concerns directly related to the incident. Alcohol tests were not available.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 16 November 2023
Resolved 13 November 2023
Resolution: Obtained saliva screening tests on board
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 13 October 2023
Resolved
Electrical connections must be suitably installed to prevent them from coming loose through vibration or accidental contact. Wire nuts on starboard engine were not protected from vibrating loose.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 2 December 2023
Resolved 13 November 2023
Resolution: Secured wire nuts
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 13 October 2023
Resolved
Piping and machinery components that exceed 220 °C (428 °F), including fittings, flanges, valves, exhaust manifolds, and turbochargers, must be insulated. Measures must be in place to prevent flammable or combustible liquid piping leaks from coming into contact with these components. Starboard engine turbo exhaust missing lagging.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 2 December 2023
Resolved 13 November 2023
Resolution: Added additional lagging
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 13 October 2023
Resolved
Machinery and electrical systems must be designed and maintained to provide for safe operation of the towing vessel and safety of persons onboard under normal and emergency conditions. Excess oil found in bilge.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 2 December 2023
Resolved 13 November 2023
Resolution: Pumped bilge out.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 13 October 2023
Resolved
Propulsion machinery, including main engines, reduction gears, shafting, bearings, and electrical equipment and systems, must: (1) Be maintained to ensure proper operation. Both shaft packings allowing excess water in.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 2 December 2023
Resolved 13 November 2023
Resolution: Stopped leaking shafts
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 13 October 2023
Resolved
Emergency lighting must be provided for all internal crew working and living areas. Emergency lighting sources must provide for sufficient illumination under emergency conditions to facilitate egress from each space. Emergency lighting above generators did not function.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 2 December 2023
Resolved 13 November 2023
Resolution: Corrected lighting and secured wires
05 - Radio Communications › N/A - No Subsystem › Other (radio communication)
Issued 13 October 2023
Resolved
Each towing vessel must be fitted with a communication system between the pilothouse and the engine room. Crew did not have a reliable communication method from engine room to bridge.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 2 December 2023
Resolved 13 November 2023
Resolution: Added handheld radio to engine room
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 13 October 2023
Resolved
Each towing vessel must be equipped with at least two portable, battery-powered lights. One must be located in the pilothouse and the other at the access to the engine room. Engine room did not have a portable light.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 2 December 2023
Resolved 13 November 2023
Resolution: Added a flashlight to engine room.
01 - Certificates & Documentation › 012 - Crew Certificates › Medical certificate
Issued 15 September 2022
Resolved
A person may not employ or engage an individual in a position required to hold an MMC unless that individual maintains a current medical certificate. Vessel master was unable to provide a valid medical certificate. 46 CFR 15.401(c)
Action required: 60 - Rectify deficiencies prior to movement
Resolved 30 September 2022
Resolution: Received master's medical certificate.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 15 September 2022
Resolved
Electrical systems and equipment must function properly and minimize system failures and fire and shock hazards. MI found the breaker panel to have a max rating of 225 amps. The total amount of breakers totaled 870 amps. A certified marine 3rd party electrician is required to provide a report attesting that the breaker panel is installed in accordance with all applicable electrical references. 46 CFR 46 CFR 143.400(a)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 September 2022
Resolved 30 September 2022
Resolution: Received satisfactory third party electrician's report.
09 - Working and Living Conditions › 091 - Living Conditions › Water, pipes, tanks
Issued 15 September 2022
Resolved
All vessel equipment must be used in accordance with the manufacturer's recommended practice and in a manner that minimizes risk of injury or death. MI found the hydro-pneumatic tank loosely secured with a ratchet strap in the engine room. Vessel is to permanently affix a bracket to secure tank. 46CFR140.505 (b)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 September 2022
Resolved 30 September 2022
Resolution: Mounting bracket installed.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 15 September 2022
Resolved
Electrical systems and equipment must function properly and minimize system failures and fire and shock hazards. MI found both generator windings dirty with oil. 46CFR143.400
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 September 2022
Resolved 30 September 2022
Resolution: P/S generator windings cleaned.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 15 September 2022
Resolved
Electrical connections must be suitably installed to prevent them from coming loose through vibration or accidental contact. MI found the battery connections to have wing nuts. Vessel to install locking nuts on battery connections. 46CFR143.400 (e)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 September 2022
Resolved 30 September 2022
Resolution: Wing nuts replaced with proper locking nuts.
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 15 September 2022
Resolved
The master must ensure that all lifesaving equipment is properly maintained and ready for use at all times. 46CFR141.230. MI found the 2nd deck portside lifebuoy retro tape failed, name of the Vessel eligible, and the life buoy plug deteriorated. 46 CFR 141.230
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 September 2022
Resolved 30 September 2022
Resolution: Life ring repaired satisfactorily.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Gauges, thermometers, etc
Issued 15 September 2022
Resolved
The following systems must be equipped with gauges at the machinery location: Hydraulic steering fluid pressure, if the vessel is equipped with hydraulic steering systems. MI discovered the gauge was improperly sized for the intended use. 46 CFR 143.230(c)(5)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 16 October 2022
Resolved 30 September 2022
Resolution: Gauge replaced with gauge of proper scale.
09 - Working and Living Conditions › 092 - Working Conditions › Guards - fencing around dangerous machinery parts
Issued 15 September 2022
Resolved
An exposed hazard such as gears and rotating machinery, must be protected by a cover, guard or rail. MI found the steering pump to motor rotating coupling exposed without a guard. 46 CFR 144.820
Action required: 50 - Rectify deficiencies w/in 30 days
Due 16 October 2022
Resolved 30 September 2022
Resolution: Guard installed.
09 - Working and Living Conditions › 092 - Working Conditions › Other (accident prevention)
Issued 15 September 2022
Resolved
Machinery and electrical systems must be designed and maintained to provide for safe operation of the towing vessel and safety of persons onboard under normal and emergency conditions. MI found the vessel’s both main diesel engine rear mounts not secured to supporting frame. 46 CFR 140.505(c)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 16 October 2022
Resolved 19 October 2022
Resolution: Rear mounts properly installed.
07 - Fire Safety › N/A - No Subsystem › Ventilation
Issued 15 September 2022
Resolved
Means must be provided for stopping each fan in a ventilation system serving machinery spaces and for closing, in case of fire, each doorway, ventilator, and annular space around funnels and other openings into such spaces. MI discovered port side natural ventilation louvre unable to seal and no mean of closing engine room exhaust fan vent. 46 CFR 144.605
Action required: 50 - Rectify deficiencies w/in 30 days
Due 16 October 2022
Resolved 30 September 2022
Resolution: Ventilation cover installed for natural vent. Mushroom style mechanical vent fan provided with means of closure.
09 - Working and Living Conditions › 091 - Living Conditions › Other (crew and accommodation)
Issued 15 September 2022
Resolved
Each EAP education program must include at least the following elements: display and distribution of informational material; display and distribution of a community service hot-line telephone number for crewmember assistance, and display and distribution of the employer's policy regarding drug and alcohol use in the workplace. The vessel did not display the above EAP informational material or have the information readily available for the crew. 46 CFR 16.401(a)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 16 October 2022
Resolved 30 September 2022
Resolution: DAPI info posted.
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 15 September 2022
Resolved
The following list of items must be recorded in the TVR, official logbook, or in accordance with the TSMS applicable to the vessel: Navigation assessment, in accordance with § 140.635. The vessel had no documented navigation assessments in their towing vessel record. 46 CFR 140.915(a)(6)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 16 October 2022
Resolved 30 September 2022
Resolution: Vessel submitted completed nav assessments.
09 - Working and Living Conditions › 091 - Living Conditions › Water, pipes, tanks
Issued 15 September 2022
Resolved
The owner or managing operator must implement procedures to identify and mitigate health and safety hazards, including but not limited to: Potable water supply. The documented procedures for potable water supply were inconsistent with actual implementation onboard the vessel. 46 CFR 140.510(a)(14)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 16 October 2022
Resolved 19 October 2022
Resolution: HSP updated.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 15 September 2022
Resolved
All fire-suppression and detection equipment and systems on board a towing vessel must be maintained in accordance with the attached nameplate, manufacturer's approved design manual, or as otherwise provided in any TSMS applicable to the vessel. The vessel did not have ready access to the approved design manual to verify maintenance procedures and testing requirements. 46 CFR 142.240(b)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 16 October 2022
Resolved 30 September 2022
Resolution: Manual is now onboard.
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 15 September 2022
Resolved
Emergency lighting must be provided for all internal crew working and living areas. Emergency lighting sources must provide for sufficient illumination under emergency conditions to facilitate egress from each space. The berthing area was not properly illuminated with either lighting or non-electric phosphorescent lighting strips. 46 CFR 143.410 (b)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 16 October 2022
Resolved 30 September 2022
Resolution: Both lighting and non-electric phosphorescent "EXIT" signs
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Safety and environment policy
Issued 2 August 2021
Resolved
All crew members must be provided with health and safety information and training..
Crew member training required by this section must be conducted as soon as practicable, but not later than 5 days after employment. Refresher training must be repeated annually and may be conducted overtime in modules.
Vessels Master and deck hands had not received training on the companies health and safety manual. Provide training and provide evidence to the satisfaction of the Marine Inspector.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 16 August 2021
Resolved 8 September 2021
Resolution: Received report from Sector Corpus that item was cleared.
10 - Safety of Navigation › N/A - No Subsystem › Navigation records
Issued 2 August 2021
Resolved
The officer in charge of a navigational watch must conduct a navigation assessment for the intended route and operations prior to getting underway. The navigation assessment must incorporate the requirements of pilothouse resource management of 140.640, assess operational risks, and anticipate and manage worload demands at minimum, this assessment must consider: (a)1-(a)13.
Vessel master was not sure of all the requirements listed and company did not provide information.
Action required: 10 - Deficiency Rectified
Resolved 2 August 2021
Resolution: Master trainied and made a navigation assessment checklist.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 2 August 2021
Resolved
Each towing vessel must have a reliable means to provide notification when an emergency condition exists or an essential system develops problems that require attention. Low hydraulic steering fluid levels.
Vessel low level alarm for steering was inoperable with no sound. Technician repaired while on board.
Action required: 10 - Deficiency Rectified
Due 2 August 2021
Resolved 2 August 2021
Resolution: Technician repaired while on board.
08 - Alarms › N/A - No Subsystem › General alarm
Issued 2 August 2021
Resolved
Each towing vessel must be fitted with a general alarm that: is capable of notifying persons in any accommodation, work space, and the engine room. Has installed in the Engine room and any other area where background noise makes a general alarm hard to hear.
Vessel did not have an audible alarm in the engine room. Vessel general alarm could not be heard on the main deck or forward. Install audible alarms to ensure all areas have an audible alarm.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 16 August 2021
Resolved 2 September 2021
Resolution: Received email from Sector Corpus that item was cleared.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 2 August 2021
Resolved
Fuel systems for towing vessel main engines and generators must have a documented maintenance plan to ensure proper operation of the system.
Vessel did not have documented maintenance plan and crew personal had different time requirements. Provide a written plan.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 16 August 2021
Resolved 9 September 2021
Resolution: Received email from Sector Corpus clearing deficiencies
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 2 August 2021
Resolved
Electrical systems and equipment must function properly and minimize system failures and fire and shock hazards.
Vessel had multiple open wires, electrical cords plugged into extension cords for critical systems including air compressor and stuffing box bilge pump, and electric outlet with water dripping onto outlet.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 16 August 2021
Resolved 9 September 2021
Resolution: Received email from Sector Corpus clearing deficiency.
Lifesaving
Issued 2 July 1999
Resolved
PROVIDE A RING LIFE BOUY
Condition: Unknown
Due 6 July 1999
Resolved 6 July 1999
Documentation
Issued 2 July 1999
Resolved
OBTAIN AVALID RADIO OPERATORS PERMIT.
Condition: Unknown
Due 6 July 1999
Resolved 6 July 1999
Navigation
Issued 2 July 1999
Resolved
PROVIDE A COPY OF INLAND NAV RULES
Condition: Unknown
Due 6 July 1999
Resolved 6 July 1999
Documentation
Issued 2 July 1999
Resolved
PROVIDE A VALID FCC SSL
Condition: Unknown
Due 6 July 1999
Resolved 6 July 1999