MARQUETTE II

MARQUETTE II is a 2005 passenger vessel (inspected). The Coast Guard has recorded 47 inspections since 2016, most recently in August 2026, along with 50 deficiencies and 8 casualty investigations between 2010 and 2025.

Records from 2010 to 2026. Most recent: inspection, 3 August 2026.

Built
2005
Last inspected
3 August 2026
Documentation
Valid · documentation file of 10 August 2026
Controls
None recorded without a removal date

Identity

WDC4831
737042
Flag
UNITED STATES
Maury page id
psix-737042

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 2016.

Inspections, by type

…with no type recorded4
Years with a record 11 calendar years (2016–2026)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. The counts in the strip above are the same counts; this table splits the inspections by the kind of activity recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Documentation record

Registered dimensions (L × B × D)74.0 ft × 24.0 ft × 8.3 ft
Registered tonnagegross 65 / net 44
ITC dimensions (L × B × D)74.0 ft × 24.0 ft × 8.3 ft
ITC tonnagegross 126 / net 72
BuilderGULF CRAFT INC · PATTERSON, LA, UNITED STATES · built 2005
Hull materialAluminum
PropulsionDiesel Reduction
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing portMACKINAC ISLAND, MI
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 20 June 2026 · expires 31 July 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it65 - Regulatory (Subpart C or D), Gross Ton
126 - Convention (Subpart B), Gross Ton
44 - Regulatory (Subpart C or D), Net Ton
72 - Convention (Subpart B), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Vessel history report
Every record for this hull, in one document — $299

What it gives that this page does not: the whole record in one dated, citable document — every line with its Coast Guard activity id, the retrieval date on the cover, built to print to PDF with its page breaks — that a surveyor can attach and a lender can file. The same facts as this page, complete and in one file.

Every recorded inspection, 2016 to 2026 for this class, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

A request, not a checkout: leave an email and Maury replies once, with the dated document for this hull and a Stripe invoice for $299. Nothing is charged before the document is in your hands.

Inspected as a tow unit · 1

The Coast Guard recorded this vessel and the following in the same inspection activity — normally a tug and the barges in its tow. A recreational or unclassed hull in the same activity is held and not published, so it does not appear here: these lists are a floor, not a complete manifest.

LA SALLE Passenger (Inspected) · MISLE 54766 · 17 July 2025 · activity 8199321

Inspection history · 47

3 August 2026 Damage Survey
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 8455009
13 May 2026 Annual Inspection
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 8383438
28 January 2026 Deficiency Check · Damage Survey · Examination of Repairs
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 8358526
28 October 2025 Deficiency Check · In-Service Inspection
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 8260104
8 September 2025 Administrative Inspection
Administrative · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 8229744
25 August 2025 Deficiency Check · Damage Survey
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 8219690
20 August 2025 In-Service Inspection
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 8215628
31 July 2025 In-Service Inspection
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 8201994
17 July 2025 Type not recorded
No type recorded · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 8199321
11 July 2025 Administrative Inspection
Administrative · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 8217805
9 May 2025 In-Service Inspection · Deficiency Check · Annual Inspection · MTSA Verification
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 8133311
13 January 2025 Administrative Inspection
Administrative · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 8062828
9 September 2024 Administrative Inspection
Administrative · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 7999089
13 July 2024 Administrative Inspection · Damage Survey
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 7957269
13 July 2024 Type not recorded
No type recorded · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 7971487
28 May 2024 MTSA Verification · COI Inspection
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 7913312
2 April 2024 Internal Structural Exam · Hull Examination
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 7891570
27 July 2023 In-Service Inspection
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 7814608
9 July 2023 Type not recorded
No type recorded · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 7744887
1 May 2023 MTSA Verification · Deficiency Check · Annual Inspection · Administrative Inspection
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 7683451
6 September 2022 Deficiency Check
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 7552670
2 September 2022 Administrative Inspection
Administrative · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 7549713
24 August 2022 In-Service Inspection
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 7546450
2 May 2022 Annual Inspection · MTSA Verification · Deficiency Check
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 7433244
30 August 2021 Deficiency Check
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 7301225
23 August 2021 In-Service Inspection
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 7341814
8 July 2021 Deficiency Check · Internal Structural Exam · Administrative Inspection
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 7248942
7 July 2021 Type not recorded
No type recorded · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 7249543
19 April 2021 Annual Inspection · MTSA Verification
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 7178558
13 September 2020 Administrative Inspection
Administrative · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 7057272
9 September 2020 Annual Inspection
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 7054483
5 August 2020 In-Service Inspection
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 7026307
27 May 2020 Deficiency Check
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 6963480
13 September 2019 Deficiency Check
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 6810817
7 June 2019 COI Inspection · DAPI Audit
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 6706635
21 February 2019 Internal Structural Exam · Hull Examination
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 6630658
18 September 2018 Administrative Inspection
Administrative · Navigation Center · Activity 6543293
18 July 2018 Annual Inspection
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 6484656
25 May 2018 Deficiency Check
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 6423440
22 May 2018 Deficiency Check · In-Service Inspection
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 6422721
5 April 2018 Administrative Inspection
Administrative · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 6385564
26 October 2017 Deficiency Check · Administrative Inspection
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 6304053
23 August 2017 Administrative Inspection
Administrative · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 6249904
1 June 2017 Deficiency Check
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 6167311
13 April 2017 MTSA Verification · Annual Inspection · Deficiency Check
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 5862409
19 April 2016 Annual Inspection · DAPI Audit · Administrative Inspection · Security Plan Review - ASP · Deficiency Check
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 5857934
8 January 2016 Construction Oversight · Plan Review (Other than "T")
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 5874339

Deficiency record · 50

13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 28 October 2025 Resolved
Sighted oil and coolant leaks on both MDE's. Determine sources of leaks and effect permanent repairs. Demonstrate proper operation prior to the carriage of passengers.
Action required: 701 - Prior to carriage of passengers/cargo
Due 28 October 2025
Resolved 7 November 2025
Resolution: company replaced STB MDE inboard exhaust manifold, turbo gaskets and Port MDE charged air cooler. Conducted full underway sea trials. No leaks noted, satisfactory results.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 31 July 2025 Resolved
Vessel crew found oil spraying from stbd main dipstick tube due to not seating correctly. Allowed temp repair of zip ties to hold the dipstick in place. Company will replace existing tube. Captain's must inspect visually daily and log findings. Report any degradation to the Coast Guard.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 14 August 2025
Resolved 9 April 2026
Resolution: Dipstick tubes replaced, all sat.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Gauges, thermometers, etc
Issued 9 May 2025 Resolved
Stbd reduction gear hydraulic temperature inoperative, erratic. Non-compliant temp sensor must be replaced with correct unit. Satisfactory operational testing must be witnessed.
Action required: 60 - Rectify deficiencies prior to movement
Due 9 May 2025
Resolved 9 May 2025
Resolution: corrected and witnessed, all sat.
07 - Fire Safety › N/A - No Subsystem › Fire-dampers
Issued 9 May 2025 Resolved
Port side engineroom fire damper inoperative.
Action required: 60 - Rectify deficiencies prior to movement
Due 9 May 2025
Resolved 9 May 2025
Resolution: Damper repaired, ops test witnessed.
07 - Fire Safety › N/A - No Subsystem › Operation of Fire protection systems
Issued 9 May 2025 Resolved
Fire station receptacle has damaged threads. Requires repairs or replacement. Fire hose not compatable with this vessel. Requires replacement.
Action required: 60 - Rectify deficiencies prior to movement
Due 9 May 2025
Resolved 9 May 2025
Resolution: Threads repaired, hose replaced, ops test witnessed. All sat.
02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-op. damage
Issued 9 May 2025 Resolved
Several cracked welds in forepeak and #3 void require repairs. 23 July: inspected cracks, they remain unchanged & pose no risk to furhter cracking, extended compliance date until after the summer operating season.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 7 June 2025
Resolved 9 April 2026
Resolution: Repaired, all sat.
09 - Working and Living Conditions › 092 - Working Conditions › Heating
Issued 9 May 2025 Resolved
Maindeck heaters supply line is corroded and cracked, must be replaced or disconnected.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 15 May 2025
Resolved 20 June 2025
Resolution: lines have been disconnected.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 9 May 2025 Resolved
Temporary electrical installation under helm must be installed permanently.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 7 June 2025
Resolved 9 July 2025
Resolution: corrected.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 17 July 2024 Resolved
Stbd MDE suffered over-pressurization which caused catastrophic internal damage requiring rebuild. Make repairs and demonstrate proper operation prior to the carriage of passengers.
Action required: 60 - Rectify deficiencies prior to movement
Due 17 July 2024
Resolved 9 May 2025
Resolution: Stbd MDE was removed and replaced-in-kind. Install inspection completed all sat. Sea trials witnessed all sat.
01 - Certificates & Documentation › 013 - Documents › Fire control plan - all
Issued 1 May 2023 Resolved
Fire and Saftey plan needs to be updated to reflect current PFD and fire extinguisher data.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 15 May 2023
Resolved 8 May 2023
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 1 May 2023 Resolved
Wrong size fire extinguisher located at entrance to the engine room.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 15 May 2023
Resolved 8 May 2023
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 1 May 2023 Resolved
Emergency escape hatch needs to be relabeled.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 15 May 2023
Resolved 8 May 2023
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 1 May 2023 Resolved
Fixed CO2 system hoses are overdue for hydro.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 15 May 2023
Resolved 15 May 2023
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 1 May 2023 Resolved
Shaft seal on hydro jet engine is leaking excessively.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 15 May 2023
Resolved 15 May 2023
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 1 May 2023 Resolved
Missing blanks at the 24 volt panel at the operating station.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 15 May 2023
Resolved 30 June 2023
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 1 May 2023 Resolved
Electrical box in engine room needs cover.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 15 May 2023
Resolved 30 June 2023
02 - Structural Conditions › N/A - No Subsystem › Hull - cracking
Issued 1 May 2023 Resolved
Found cracked welds on bow and stbd quarter.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 15 May 2023
Resolved 30 June 2023
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 1 May 2023 Resolved
Found a dead end wire on each MDE.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 15 May 2023
Resolved 15 May 2023
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 2 May 2022 Resolved
RLB’s need vessel name re-marked.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 16 May 2022
Resolved 18 May 2022
Resolution: corrected.
02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-op. damage
Issued 2 May 2022 Resolved
Stbd boarding ramp requires repairs (welding). Cracked welds on forward bit, canopy repairs and multiple main deck seat bases.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 2 June 2022
Resolved 18 May 2022
Resolution: repaired.
09 - Working and Living Conditions › 092 - Working Conditions › Warning notices
Issued 2 May 2022 Resolved
Vessel requires markings for no passengers beyond this point on main deck & 2nd deck. Engineroom emergency escape needs marking.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 1 June 2022
Resolved 6 September 2022
Resolution: corrected.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 2 May 2022 Resolved
Oil leaks sighted on both MDE’s and hydro-jet engine, monitor and repair, report to Marine Inspector the results.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 16 May 2022
Resolved 6 September 2022
Resolution: corrected.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 2 May 2022 Resolved
#2 void air compressor (for vessel whistle) has oil leak, must be repaired or replaced. Air compressor must be locked & tagged out for no use until repaired/replaced. Vessel must have alternate sound signaling device available to ships’ crew, ships’ crew must be made aware and properly trained. **Compressor on order, 6-8 weeks out.
Action required: 705 - Other - as specified
Due 16 July 2022
Resolved 15 June 2023
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 2 May 2022 Resolved
Fuel drip sighted on fuel tank sight glass shutoff valve. Valve is secured. Monitor daily and any increase must be immediately reported to the [name withheld] on order, 1-2 weeks out. Has this been received & installed?
Action required: 16 - Rectify deficiencies w/in 14 days
Due 16 May 2022
Resolved 6 September 2022
Resolution: replaced.
02 - Structural Conditions › N/A - No Subsystem › Hull damage impairing seaworthiness
Issued 8 July 2021 Resolved
Vessel grounded while maneuvering near dock in Mackinaw City. Prior to vessel movement conduct internal damage survey with USCG inspectors.
Action required: 60 - Rectify deficiencies prior to movement
Resolved 10 July 2021
Resolution: Corrected.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 8 July 2021 Resolved
After grounding, the voulcan coupling was found damaged and in need of replacement.
Action required: 60 - Rectify deficiencies prior to movement
Due 8 July 2021
Resolved 10 July 2021
Resolution: Corrected.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 8 July 2021 Resolved
Hydro-jet engine was found to have excessive oil leaks. Locate and secure sources of all oil leaks to the satisfaction of the attending MI. Do not use hydro-jet engine with passengers onboard until cleared.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 5 August 2021
Resolved 30 August 2021
Resolution: Corrected.
09 - Working and Living Conditions › 092 - Working Conditions › Guards - fencing around dangerous machinery parts
Issued 8 July 2021 Resolved
Guard around fire pump on the port engine not in place. Replace guard.
Action required: 60 - Rectify deficiencies prior to movement
Due 8 July 2021
Resolved 10 July 2021
Resolution: Corrected.
02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-op. damage
Issued 19 April 2021 Resolved
Fractured welds sighted & marked in forepeak and on stbd side ramp. Canopy has stress fractures at 4 stanchions port and stbd sides at main deck intersection and 3.5 feet above main deck. Effect permanent repairs to forepeak and ramp. Effect temporary repairs to canopy as approved by attending Marine Inspector; monitor weekly for additional fracturing.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 19 May 2021
Resolved 14 July 2021
Resolution: Received statement from Sr. Captain and pictures depicting temp repairs completed.
02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-op. damage
Issued 19 April 2021 Resolved
Make canopy and overhead canopy structures available for close inspection after completion of 2021 operating season. Submit permanent repair proposal to OCMI.
Action required: 705 - Other - as specified
Due 1 November 2021
Resolved 2 May 2022
Resolution: completed.
10 - Safety of Navigation › N/A - No Subsystem › Rudder angle indicator
Issued 19 April 2021 Resolved
Rudder angle indicator inoperative. Repair and demonstrate proper operation to attending CG MI.
Action required: 17 - Rectify deficiencies prior to departure
Due 27 April 2021
Resolved 28 April 2021
Resolution: Company rebuilt wiring harness. MI witnessed repair through a texted video and statement from the company rep.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 19 April 2021 Resolved
Stbd MDE has error code; vendor to attend/repair. Repair & demonstrate proper operation. Provide tech report.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 3 May 2021
Resolved 22 April 2021
Resolution: Resolved by MDE vendor.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 13 September 2020 Resolved
Starboard Main Engine main seal failure.
Condition: Invalid
Action required: 60 - Rectify deficiencies prior to movement
Due 27 September 2020
Resolved 1 October 2020
Resolution: Rep replaced seal.
09 - Working and Living Conditions › 091 - Living Conditions › Other (crew and accommodation)
Issued 27 June 2019 Resolved
Repair fractures at the base of 06 benches located in the inside cabin.
Condition: Design Flaw
Action required: 50 - Rectify deficiencies w/in 30 days
Due 27 July 2019
Resolved 27 May 2020
Resolution: Welded and corrected.
02 - Structural Conditions › N/A - No Subsystem › Steering gear
Issued 20 April 2019 Resolved
Replace port and starboard rudder post bearings due to excessive wear.
Action required: 705 - Other - as specified
Due 30 August 2019
Resolved 30 August 2019
Resolution: Recieved confirmation from Starline Safety Rep that repairs were effected satisfactorily. Will confirm during next visit.
10 - Safety of Navigation › N/A - No Subsystem › Automatic Identification System (AIS)
Issued 18 September 2018 Resolved
The vessel is currently broadcasting (1) Zero Draft, (2) No Ship type. The Ship should be 60 per the US official Encoding guide.
Condition: Invalid
Action required: 705 - Other - as specified
Due 18 October 2018
Resolved 15 May 2019
Resolution: Received notification of AIS broadcasting correction from vessel owner. Verified no errors in VIVS.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 18 July 2018 Resolved
Wheelhouse portable fire extinguisher was 2-B, not B-I, addional PFE provided during inspection was B-II in wheelhouse.
Condition: Improper Installation
Action required: 10 - Deficiency Rectified
Due 18 July 2018
Resolved 18 July 2018
11 - Life Saving Appliances › N/A - No Subsystem › On board training and instructions
Issued 18 July 2018 Resolved
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 18 July 2018
Resolved 18 July 2018
Fire Fighting › Ventilation Systems › Duct Hatches
Issued 22 May 2018 Resolved
Demonstrate proper operation of the engineroom power ventilation closures.
Condition: Damaged By Earlier Event
Action required: 701 - Prior to carriage of passengers/cargo
Due 5 June 2018
Resolved 25 May 2018
Resolution: Replaced selonoids, satisfactory operational check completed.
Engineering › Engine Controls (Electric/Electronic) › Software
Issued 26 October 2017 Resolved
Remove all accessories and after market software/monitoring equipment that has been installed without approval from the Marine Safety Center/[name withheld] proper operation of the propulsion system controls and both main diesel engines.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 1 November 2017
Resolved 31 October 2017
Resolution: Confirmed GPLink was disconnected from electronic control units, it was also disconnected from the power supply so it couldn’t easily be reconnected.
Engineering › Diesel Engine (propulsion-reduction gear) › Connecting Rod
Issued 23 August 2017 Resolved
Determine cause of starboard engine failure, make permanent repairs and demonstrate proper operation of same to the satisfaction of the attending marine inspector.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 15 May 2018
Resolved 22 May 2018
Resolution: MDE removed, rebuilt & reinstalled. Underway operational checks completed with no discreps.
Documentation › Manifests/Lists › Muster List/Emergency Instructions
Issued 13 April 2017 Resolved
Properly post instructions and broadcast placard in pilothouse
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 27 April 2017
Resolved 1 May 2017
Resolution: Posted.
Personnel › Manning/Qualifications › Minimum Safe Manning
Issued 13 April 2017 Resolved
Provide Sr. deckhand designations.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 26 May 2017
Resolved 1 June 2017
Resolution: Sighted appropriate designation ltr.
Fire Fighting › Miscellaneous Items › Waste Receptacles
Issued 13 April 2017 Resolved
Remove combustible pilothouse trash can. Replace with noncombustible type if desired.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 13 May 2017
Resolved 1 May 2017
Resolution: Replaced.
Electrical › Electrical Distribution System (service) › Cable
Issued 20 April 2016 Resolved
Remove all welding cable installed in power supply circuits. replace with UL Boat or UL Marine Cable as per 46 CFR 120.340.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 4 May 2016
Resolved 4 May 2016
Resolution: Replaced all cable with Boat Cable.
Electrical › Electrical Distribution System (service) › Cable
Issued 20 April 2016 Resolved
Properly insulate exposed negative cable on port battery.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 4 May 2016
Resolved 4 May 2016
Resolution: Replaced cable with Boat Cable.
Electrical › Electric Supply System (service) › Battery Charger
Issued 20 April 2016 Resolved
Deomnstrate proper overcurrent protection to battery chargers in engine room.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 4 May 2016
Resolved 4 May 2016
Resolution: Installed overcurrent protection
Fire Fighting › Means of Escape › Escape Route Signs
Issued 20 April 2016 Resolved
Provide emergency escape signage for fore and aft escpae route on main deck.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 4 May 2016
Resolved 4 May 2016
Resolution: Provided signage in passenger cabin
Stability › Intact Stability (when using lifting gear) › General
Issued 20 April 2016 Resolved
Properly label thrid deck passenger capacity to no more than 70 passengers iaw stability letter dated February 28, 2011.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 4 May 2016
Resolved 4 May 2016
Resolution: Provided signage
Lifesaving › Lifefloat › Painter
Issued 20 April 2016 Resolved
Line attaching group of lifefloats is not long enough to permit individual launch of each apparatus. Provide proper length of line iaw 46 CFR 117.137
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 4 May 2016
Resolved 4 May 2016
Resolution: Installed sufficient length of line.

Casualty record · 8

5 August 2010Routine · role: Involved in a Marine Casualty · activity 3833173
4 September 2010Routine · role: Involved in a Marine Casualty · activity 3844388
19 May 2012Routine · role: Involved in a Marine Casualty · activity 4327029
14 September 2013Routine · role: Involved in a Marine Casualty · activity 4715928
7 July 2021Routine · role: Involved in a Marine Casualty · activity 7249543
9 July 2023Routine · role: Involved in a Marine Casualty · serious marine incident, as classified · 1 injured · activity 7744887
13 July 2024Routine · role: Involved in a Marine Casualty · activity 7971487
17 July 2025Routine · role: Transiting Vicinity of Primary Subject · activity 8199321
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.