Records from 2006 to 2026. Most recent: inspection, 12 May 2026.
Inspection history · 19
12 May 2026
Annual Inspection
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 8370776
18 November 2025
Bulk Liquid Transfer Monitor
Physical examination · Marine Safety Unit New Bedford · USCG Northeast District (CGD-NE) · Activity 8270606
14 April 2025
COI Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 8101101
1 April 2025
Drydock Exam · Internal Structural Exam
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 8102737
22 April 2024
MTSA/ISPS Verification · Annual Inspection · Deficiency Check
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 7899574
20 September 2023
Deficiency Check
Physical examination · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 7794498
2 August 2023
Periodic Inspection · MTSA Verification
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7760319
10 July 2023
Internal Structural Exam · Hull Examination
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7738234
24 August 2022
Annual Inspection · Administrative Inspection · MTSA/ISPS Verification
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7542951
24 August 2021
Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7294967
4 June 2020
Administrative Inspection · Cargo Tank Internal · Hull Examination · Drydock Exam · Internal Structural Exam
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6968249
28 May 2020
COI Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7013569
21 October 2019
Annual Inspection · Deficiency Check · Administrative Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6838494
29 August 2018
Administrative Inspection · Periodic Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6526642
24 August 2018
Hull Examination · Cargo Tank Internal · Internal Structural Exam · Administrative Inspection · Drydock Exam
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6521368
16 October 2017
Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6288776
5 October 2017
Administrative Inspection
Administrative · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6295007
2 October 2017
Administrative Inspection
Administrative · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 6281937
31 August 2016
Annual Inspection · MTSA Verification
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 5988870
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 14 April 2025
Resolved
The VSP must be audited annual with a letter certified by the CSO or VSO stating the audit was completed. No record of an annual audit for 2024. VSP was not up to date with the latest company/vessel info (CSO and vessel name/particulars).
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 14 May 2025
Resolved 15 April 2025
Resolution: CSO provided audit letter and update security plan.
11 - Life Saving Appliances › N/A - No Subsystem › Immersion suits
Issued 14 April 2025
Resolved
Each immersion suit must be marked with the vessel name. Immersion suits were marked with the incorrect vessel name.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 14 May 2025
Resolved 16 April 2025
Resolution: Immersion suits labeled.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 14 April 2025
Resolved
Each self-propelled vessel must have duplicate light sources for the side, masthead, and stern lights. The secondary lights for multiple nav lights did not work.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 14 April 2025
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 14 April 2025
Resolved
Each panelboard (distribution panel) must have a circuit directory with the description of the load for each circuit. Panel L-1 in the engine room had two breakers that were not labeled.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 14 April 2025
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 14 April 2025
Resolved
Electric installations must ensure maintenance of services necessary for safety under normal conditions. The circuit breaker for the port liquid mud pump would constantly trip when trying to reset.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 14 April 2025
04 - Emergency Systems › N/A - No Subsystem › Emergency fire pump and its pipes
Issued 14 April 2025
Resolved
Each OSV must have in the pilothouse controls to monitor the pressure in the fire main. The fire main pressure gauge in pilothouse did not work.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 14 April 2025
11 - Life Saving Appliances › N/A - No Subsystem › Launching arrangements for survival craft
Issued 14 April 2025
Resolved
Each muster station and embarkation station must be adequately illuminated by lighting supplied from the emergency source of electrical power. Emergency lighting was not sufficient at the embarkation station.
Condition: Placed in Improper Service
Action required: 50 - Rectify deficiencies w/in 30 days
Due 14 May 2025
Resolved 16 April 2025
Resolution: Lights replaced to illuminate launching and embarkation stations.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 22 April 2024
Resolved
The number and placement of fire detectors must be approved by the cognizant [name withheld] detector in stateroom F was inoperable.
46CFR130.470(c)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 24 May 2024
Resolved 24 May 2024
Resolution: Cleared
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 22 April 2024
Resolved
Each vessel must be designed and constructed to minimize fire hazards as far as reasonable and practicable. No.1 Generator's lubrication system for air starter was spraying excessive amounts of atomized diesel.
46CFR127.220(a)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 24 May 2024
Resolved 24 May 2024
Resolution: Cleared
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 22 April 2024
Resolved
Each vessel must be designed and constructed to minimize fire hazards as far as reasonable and practicable. Fuel flow meter was leaking excessive amounts of fuel.
46CFR127.220(a)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 24 May 2024
Resolved 24 May 2024
Resolution: Cleared
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 22 April 2024
Resolved
Electrical equipment and installations must be suitable for roll, pitch and vibration of the vessel underway. No.2 Generator chaffing gear not protecting cable from lifting pad eye on generator.
46CFR129.220(a)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 24 May 2024
Resolved 24 May 2024
Resolution: Cleared
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Other (cargo)
Issued 22 April 2024
Resolved
An OSV may carry in integral and fixed tanks NLSs listed by 153.2 of this chapter, in quantities not to exceed 20 percent of the vessel's dead weight. P/V valves were removed for carriage of methanol that is authorized on vessel's COI.
46CFR125.120(b)
Action required: 705 - Other - as specified
Due 24 April 2025
Resolved 24 May 2024
Resolution: Cleared
01 - Certificates & Documentation › 012 - Crew Certificates › Certificates for radio personnel
Issued 2 August 2023
Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Action required: 50 - Rectify deficiencies w/in 30 days
Due 31 August 2023
Resolved 28 August 2023
Resolution: Vessel Rep requested to go domestic only.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 2 August 2023
Resolved
Electrical equipment on a vessel must be designed, installed and maintained to protect crew, offshore workers, and vessel from electrical hazards. Vessel had a wire that had exposed wire ends & took 5 min to trace.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 31 August 2023
Resolved 20 September 2023
Resolution: Walked through vessels engine room and verified the dead end wire was properly removed,
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 2 August 2023
Resolved
When carrying flammable or combustible cargoes, additional fire protection shall be on board and properly maintained. Vessel's foam inductor was not functional and the vessel did not have the required dry chemical fire extinguishers. 705 - Vessel may not carry flammable or combustible cargoes in marine portable tanks or DOT tanks.
Action required: 705 - Other - as specified
Resolved 20 September 2023
Resolution: Witnessed proper operation of the vessels foam eductor.
07 - Fire Safety › N/A - No Subsystem › Ready availability of fire fighting equipment
Issued 2 August 2023
Resolved
Master shall ensure that the vessel's required firefighting equipment is on board in prescribed locations and always ready for use. The 01 deck fire station was secured with rope and not ready for immediate use to where the crew took over 5 minutes to untie and extend the fire hose.
Action required: 10 - Deficiency Rectified
Resolved 2 August 2023
Resolution: Vessel untied the line holding the bracket and properly stowed the fire hose.
05 - Radio Communications › N/A - No Subsystem › Operation of GMDSS equipment
Issued 2 August 2023
Resolved
Each vessel must comply with 47CFR Part 80 as applicable. Vessel had the GMDSS function turned off and had not been maintaining watch on GMDSS.
Action required: 10 - Deficiency Rectified
Resolved 2 August 2023
Resolution: Educated vessel crew and vessel rep on requirements for maintaining a watch on GMDSS.
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 2 August 2023
Resolved
Each vessel must carry adequate and up-to-date charts. Vessel's last recorded chart update was on 13JAN2023.
Action required: 10 - Deficiency Rectified
Resolved 2 August 2023
Resolution: Educated crew on updated chart requirement.
04 - Emergency Systems › N/A - No Subsystem › Fire drills
Issued 2 August 2023
Resolved
A fire drill must be held on each vessel, normally on alternate weeks. Fire drills were be held monthly per SMS training schedule:30JUL, 02JUL & 03JUN, etc.
Action required: 10 - Deficiency Rectified
Resolved 2 August 2023
Resolution: Educated crew on fire drill requirement of alternating weeks.
04 - Emergency Systems › N/A - No Subsystem › Abandon ship drills
Issued 2 August 2023
Resolved
An abandon ship drill must be held on each vessel, normally on alternate weeks. Abandon ship drills were being held montly per SMS training schedule: 23JUL & 25JUN, etc.
Action required: 10 - Deficiency Rectified
Resolved 2 August 2023
Resolution: Educated crew of requirement for abandon ship drills on alternating weeks.
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 2 August 2023
Resolved
The following matters must be entered in each vessel's logbook, Test and Inspection of Steering gear, draft and loadline markings, Tests of Emergency Lighting and Power, Abandon Ship and Firefighting drills. Vessel's log book did not contain steering tests, emergency lighting tests, etc.
Action required: 10 - Deficiency Rectified
Resolved 10 August 2023
Resolution: Educated crew on matters that are required to be logged.
05 - Radio Communications › N/A - No Subsystem › VHF EPIRB
Issued 2 August 2023
Resolved
Vessel shall ensure that EPIRB and SART are tested monthly and logged in the vessel's logbook. Vessel did not record lifesaving checks from the beginning of the log 23MAY to 09JUL and from 09JUL to the inspection.
Action required: 10 - Deficiency Rectified
Resolved 2 August 2023
Resolution: Educated Crew about required lifesaving checks.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 24 August 2022
Resolved
Vessel shall minimize fire hazards.
Starboard generator fuel lines had excessive chafing. Fuel lines need to be replaced.
46 CFR 92.05-1
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 25 August 2022
Resolved 25 August 2022
Resolution: Replaced hoses.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 24 August 2022
Resolved
Fire hose must conform to U. L. Standard 19 or Federal Specification ZZ-H-451E.
Fire hose in engine room passageway hydrant was chafed to where it was not serviceable.
46 CFR 95.10-10(n)(3)
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 25 August 2022
Resolved 25 August 2022
Resolution: Replaced fire hose.
11 - Life Saving Appliances › N/A - No Subsystem › Line-throwing appliance
Issued 24 August 2022
Resolved
Each vessel must have a line throwing appliance approved under approval series 160.040 with an auxiliary line that is at least 1,500 feet long.
Vessel had incorrect line throwing device for Subchapter "I" service, and did not have an auxiliary line on board. Vessel is limited to Subchapter "L" service, until proper line throwing device is on board. Vessel must obtain auxiliary line prior to departure.
46 CFR 199.170
8/25/22: Vessel acquired auxiliary line. Changed deficiency to restricted to "L" service. Vessel needs impulse type line throwing device to meet "I" requirement.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 16 September 2022
Resolution: Received email showing picture of four (04) impulse line throwing.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 24 August 2022
Resolved
Nonmetallic flexible hose may be used in fuel oil systems, only where lengths do not exceed 30 inches.
Port and starboard generator had flexible fuel hoses over 30 inches in length. Vessel will need to rectify during next scheduled drydock period.
46 CFR 56.60-25(b)(4)
Condition: Improper Installation
Action required: 705 - Other - as specified
Resolved 2 August 2023
Resolution: Vessel corrected issue.
14 - Pollution Prevention › 146 - MARPOL Annex VI › Bunker delivery notes
Issued 24 August 2022
Resolved
Every vessel over 400 GT shall have the bunker delivery note kept on board the vessel NLT three years and the bunker sample shall be kept on board until the fuel oil is substantially consumed, but NLT 12 months after delivery. Vessel did not have bunker notes for the previous 3 years nor fuel samples for the past 12 months.
MARPOL VI/18.5 & MARPOL VI/18.8.1
Action required: 702 - Prior to embarking on international voyage
Resolved 28 August 2023
Resolution: Vessel Rep requested for vessel to be domestic only.
01 - Certificates & Documentation › 013 - Documents › Oil record book
Issued 24 August 2022
Resolved
Every ship of 400 GT and above shall be provided with an Oil Record Book Part 1 and shall be completed on each occasion when machinery space operations occurs on vessel. Vessel’s Oil Record Book was from the previous vessel’s name, not completed IAW the ORB’s instructions, and had incorrect corrections using whiteout. Vessel’s Master had signed an incomplete page in the previous oil record book.
Action required: 702 - Prior to embarking on international voyage
Resolved 28 August 2023
Resolution: Vessel Rep requested vessel to be domestic only.
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 24 August 2021
Resolved
The emergency power source must meet table 112.05-5(a) and capacity to supply all loads that are simultaneously connected. Embarkation lights were not operable on emergency power. 46 CFR 112.05-5
Action required: 17 - Rectify deficiencies prior to departure
Resolved 24 August 2021
Resolution: Vessel rep provided photographic and video evidence of the embarkation lights being operational on E power.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 21 October 2019
Resolved
STBD generator prime mover failed to shut off during overspeed test. Provide evidence of overspeed automatic shutdown.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 21 October 2019
Resolved 21 October 2019
Resolution: Witnessed operation of overspeed shutdown.
02 - Structural Conditions › N/A - No Subsystem › Steering gear
Issued 21 October 2019
Resolved
Hydraulic hoses for steering system were wasted. Replace worn hoses.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 November 2019
Resolved 22 October 2019
Resolution: Inspected new installed hoses and tested steering at the station, all sat.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Gauges, thermometers, etc
Issued 21 October 2019
Resolved
Ammeter on switchboard was not functional. Provide evidence of working ammeter.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 21 November 2019
Resolved 22 October 2019
Resolution: Witnessed test of new ammeter, all sat.
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 21 October 2019
Resolved
Port side embarkation e-light was out. Provide evidence of working light.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 21 October 2019
Resolved 21 October 2019
Resolution: Replaced broken bulb.
07 - Fire Safety › N/A - No Subsystem › Ready availability of fire fighting equipment
Issued 21 October 2019
Resolved
In-line eductor for portable foam was not taking suction from fire station. Provide evidence of operation of eductor prior to carriage of portable tanks.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 21 October 2019
Resolved 22 October 2019
Resolution: Witnessed proper operation of the eductor with a vari-nozzle installed, all sat.