KIRBY 11315 is a 2005 tank barge. The Coast Guard has recorded 30 inspections since 2005, most recently in January 2026, along with 5 deficiencies and 2 casualty investigations in 2012.

Records from 2005 to 2026. Most recent: inspection, 20 January 2026.

Built
2005
Last inspected
20 January 2026
Documentation
Valid · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

771072
Flag
UNITED STATES
—
Maury page id
psix-771072

Inspections, by type

…with no type recorded2
Years with a record 19 calendar years (2005–2026)
The 30 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Barge class in Maury's sources begin in 1972.

Documentation record

Registered dimensions (L × B × D)200.0 ft × 35.0 ft × 12.5 ft
Registered tonnagegross 735 / net 735
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderJEFFBOAT LLC · JEFFERSONVILLE, IN, UNITED STATES · built 2005
Hull materialSteel
PropulsionNot recorded
Hull shapeBox
Hull configurationMonohull
Hailing portWILMINGTON, DE
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 11 September 2025 · expires 31 October 2026
Service, as the file records itTank Barge
Hull formbarge (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it735 - Simplified, Gross Ton
735 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspected as a tow unit · 4

Inspection history · 30

20 January 2026 COI Inspection · MTSA Verification · Cargo Tank Internal · Examination of Repairs · Drydock Exam · Internal Structural Exam
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 8295497
15 March 2023 Administrative Inspection · Examination of Repairs
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7651485
26 February 2023 Administrative Inspection
Administrative · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7667830
12 December 2022 Examination of Repairs · Administrative Inspection
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7607779
1 December 2022 Administrative Inspection
Administrative · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7629878
1 March 2021 Construction Oversight · Administrative Inspection
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7147951
14 August 2020 COI Inspection · Internal Structural Exam · MTSA Verification
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 7029113
27 April 2018 Administrative Inspection · Annual Inspection · MTSA Verification
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6489718
3 May 2017 Periodic Inspection · Administrative Inspection · MTSA Verification
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6138367
31 August 2016 Administrative Inspection
Administrative · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 5988748
19 May 2016 MTSA Verification · Administrative Inspection · Annual Inspection
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 5885053
23 June 2015 MTSA Verification · Cargo Tank Internal · Hull Examination · COI Inspection · Internal Structural Exam
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 5160055
30 September 2014 Damage Survey
Physical examination · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 4997441
18 August 2014 Annual Inspection · MTSA Verification
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 5007500
12 August 2013 MTSA Verification · Annual Inspection
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 4772608
5 June 2013 Cargo Tank Internal · MTSA Verification · Administrative Inspection
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 4611959
29 September 2012 Type not recorded
No type recorded · Marine Safety Unit Victoria · USCG Heartland District (CGD-H) · Activity 4454486
31 August 2012 MTSA Verification · Periodic Inspection
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 4427167
26 June 2012 Type not recorded
No type recorded · Marine Safety Unit Victoria · USCG Heartland District (CGD-H) · Activity 4358572
30 August 2011 Annual Inspection · MTSA Verification
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 4168655
5 October 2010 COI Inspection · MTSA Verification · Internal Structural Exam
Physical examination · Marine Safety Unit Galveston · USCG Heartland District (CGD-H) · Activity 3864737
19 August 2009 Cargo Tank Internal
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3570418
19 August 2009 Annual Inspection
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3622818
14 October 2008 Annual Inspection
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3344483
17 September 2007 Cargo Tank Internal · MTSA Verification · Periodic Inspection
Physical examination · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 3070318
11 September 2006 Annual Inspection · MTSA Verification
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 2775489
11 August 2006 MTSA Verification · Administrative Inspection
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 2749989
14 February 2006 MTSA Verification
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 2585012
29 September 2005 Cargo Tank Internal · Hull Examination · Initial Certification · Internal Structural Exam · MTSA Verification
Physical examination · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 2502907
18 August 2005 Security Plan Amendment Review - ASP
Administrative · Marine Safety Center (MSC) · Activity 2466921

Deficiency record · 5

Construction/Loadline › Structures › Rake
Issued 5 October 2010 Resolved
Complete ISE.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 14 October 2010
Resolution: USCG Inspectors completed ISE. All Sat.
Deck/Cargo › Vapor Control Systems › Piping/Hoses
Issued 5 October 2010 Resolved
Open Vapor Line for inspection.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 14 October 2010
Resolution: Vapor Line was opened and inspected by USCG Inspectors. Sat.
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Pressure/Vacuum Relief Valve
Issued 5 October 2010 Resolved
Make the P/V Valve availible for inspection.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 14 October 2010
Resolution: P/V Valve was availible and USCG inspectors checked the valve. Sat.
Deck/Cargo › Holds/Tanks › Hatch
Issued 5 October 2010 Resolved
Lable all cargo tank hatches "Danger Keep Out"
Due 5 November 2010
Resolved 14 October 2010
Resolution: Cargo Tank hatches "Danger Keep Out" signs were redone.
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Cargo Pump
Issued 29 September 2005 Resolved
Vessel owners are to prove that cargo pump engine units are in complete compliance with 46 CFR 111.105-31(l).
Action required: 705 - Other - as specified
Due 30 June 2011
Resolved 31 August 2012

Casualty record · 2

26 June 2012Routine · role: Transiting Vicinity of Primary Subject · activity 4358572
29 September 2012Routine · role: Involved in a Marine Casualty · activity 4454486
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.