Records from 2005 to 2025. Most recent: inspection, 5 December 2025.
Documentation record
Registered dimensions (L × B × D)154.5 ft × 36.0 ft × 12.0 ft
Registered tonnagegross 80 / net 54
ITC dimensions (L × B × D)154.5 ft × 36.0 ft × 12.0 ft
ITC tonnagegross 498 / net 149
BuilderMASTER BOAT BUILDERS INC · CODEN, AL, UNITED STATES · built 2005
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portNEW ORLEANS, LA
Trade endorsementsCoastwise, unrestricted, Registry
DocumentationValid · issued 5 March 2026 · expires 31 March 2027
Service, as the file records itOffshore Supply Vessel
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it80 - Regulatory (Subpart C or D), Gross Ton
498 - Convention (Subpart B), Gross Ton
658 - Dead Weight, Net Ton
54 - Regulatory (Subpart C or D), Net Ton
149 - Convention (Subpart B), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Inspection history · 34
5 December 2025
Internal Structural Exam · Deficiency Check · Drydock Exam
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 8277989
16 December 2024
Annual Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 8048207
7 February 2024
Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7862345
7 December 2023
Internal Structural Exam · Drydock Exam · Deficiency Check
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 7836169
17 April 2023
Deficiency Check · Administrative Inspection · Damage Survey
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7672563
11 April 2023
Damage Survey · Deficiency Check
Physical examination · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 7666373
10 April 2023
Type not recorded
No type recorded · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 7792403
17 February 2023
Deficiency Check · Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 7634747
17 February 2023
Type not recorded
No type recorded · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 7782020
19 June 2022
Type not recorded
No type recorded · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7499456
3 March 2022
Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7405484
8 December 2020
COI Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7108585
30 November 2020
Cargo Tank Internal · Drydock Exam · Internal Structural Exam
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7103675
14 February 2020
Annual Inspection · Administrative Inspection · Deficiency Check
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6909078
15 November 2018
Administrative Inspection · Periodic Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6581541
6 November 2018
In-Service Inspection · Internal Structural Exam · Administrative Inspection · Hull Examination
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6575748
17 October 2018
Type not recorded
No type recorded · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6580508
14 November 2017
MTSA Verification · Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Unit Lafayette · USCG Heartland District (CGD-H) · Activity 6310346
8 February 2017
MTSA Verification · Administrative Inspection · Annual Inspection · Deficiency Check
Physical examination · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 6081289
26 January 2017
Type not recorded
No type recorded · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 6077834
18 November 2015
COI Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 5765354
5 November 2015
Internal Structural Exam · Administrative Inspection · Hull Examination
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 5758297
2 February 2012
Deficiency Check · Administrative Inspection · MTSA Verification · Annual Inspection · DAPI Audit
Physical examination · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 4231711
27 October 2010
Hull Examination · MTSA Verification · Cargo Tank Internal · Internal Structural Exam · COI Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3878342
22 December 2008
Administrative Inspection
Administrative · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3383748
27 October 2008
MTSA/ISPS Verification · Drydock Exam · Hull Examination · Administrative Inspection · Internal Structural Exam · Ballast Water Examination
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3352364
7 November 2007
Administrative Inspection · MTSA/ISPS Verification
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3094121
1 November 2007
Administrative Inspection
Administrative · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3091495
11 October 2007
Administrative Inspection
Administrative · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3077802
9 October 2007
MTSA Verification · Periodic Inspection · MARPOL Annex I Examination
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3076230
10 January 2007
Deficiency Check
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 2853424
23 October 2006
Security Plan Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2806607
20 September 2005
Security Plan Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2497231
21 April 2005
MTSA Verification · Hull Examination · Ballast Water Examination · MARPOL Annex I Examination · Welding Related Inspections Qualification Testing · MARPOL Annex V Examination · Initial Construction-Excluding Oversight · Cargo Tank Internal · Construction Oversight · Plan Review (Other than "T") · Initial Certification
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 2536012
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 7 December 2023
Resolved
The inspection for certification is made by a marine inspector to determine whether the vessel is in a safe and seaworthy condition. The owner or builder shall make the vessel and its equipment available for inspection, including the following items:(a) Structure. The following work list items were noted:
1) #1 Port and Stbd mud tanks- holes in sounding tubes and wasted piping- crop and renew 2) Forepeak- missing section of sounding tube- crop and renew 3) Port fresh water tank- damaged tripping bracket- crop and renew 4) Aft bulwark inset- crop and renew
Action required: 17 - Rectify deficiencies prior to departure
Due 31 December 2023
Resolved 21 December 2023
Resolution: All repairs completed and witness by MI.
02 - Structural Conditions › N/A - No Subsystem › Closing devices/watertight doors
Issued 17 February 2023
Resolved
A Class-1 door may be installed at any place if the vessel's pilothouse contains a visual indicator showing whether the door is open or closed. The indicator for the Class I w/t door in the engineroom that leads to escape hatch is not operating. Make repairs and prove proper operation to CG Marine Inspector. Until repairs are proven, hourly checks on door to ensure it is closed while underway shall be made and logged. 46 CFR 174.210 (c) (3)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 3 March 2023
Resolved 23 February 2023
Resolution: Vessel provided photographic evidence that door open and closed indicators working properly. Photos attached under Deficiencies > Documents tab.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 14 February 2020
Resolved
Each vsl switchboard must have ground detection that meets sub part 111.105. Observed ground detection on main switchboard that had ground fault or faulty lamp.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 28 February 2020
Resolved 16 February 2020
Resolution: Ground identified and corrected
03 - Water/Weathertight Conditions › N/A - No Subsystem › Doors
Issued 14 February 2020
Resolved
The marine inspector during inspection shall determine whether the vessel is in a safe and seaworthy condition, including the vessel’s watertight integrity. Observed poor gasket in STBD E/R Escape Hatch and poor fitting of E/R watertight door leading to STBD escape trunk.
Action required: 17 - Rectify deficiencies prior to departure
Due 14 February 2020
Resolved 14 February 2020
Resolution: Adjusted escape hatch and replaced gasket. Verified by ABS.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 14 February 2020
Resolved
Vessel piping systems and arrangements shall be done so that the completely erected piping conforms with the requirements of the regulations within subchapter F. Observed unauthorized portable bilge piping system.
Action required: 17 - Rectify deficiencies prior to departure
Due 14 February 2020
Resolved 14 February 2020
Resolution: Portable piping removed and fixed piping plugged off.
14 - Pollution Prevention › 141 - MARPOL Annex I › Retention of oil on board
Issued 14 February 2020
Resolved
Containment must be sealed and watertight. Observed containment with inoperable scupper plugs.
Action required: 10 - Deficiency Rectified
Due 14 February 2020
Resolved 14 February 2020
Resolution: Installed operable scupper plugs.
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 14 February 2020
Resolved
Each life float painter must be stowed in such a way that it runs out freely when the life float floats away from sinking OSV. Observed painter on stbd life float that did not run out freely.
Action required: 17 - Rectify deficiencies prior to departure
Due 14 February 2020
Resolved 14 February 2020
Resolution: Painter line replaced and properly installed.
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 14 February 2020
Resolved
Each life float painter must have a float-free link meeting the requirements of sub part 160.073. Observed float-free link on port life float with no tag that certifies it to the proper rated persons for life float.
Action required: 17 - Rectify deficiencies prior to departure
Due 14 February 2020
Resolved 14 February 2020
Resolution: Attached new wink link.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 14 February 2020
Resolved
Each lifebuoy must be marked in block capital letters with the name of the OSV and the name of the port. Each lifebuoy must be marked with retro-reflective tape. Observed multiple lifebuoys with faded retro-reflective tape as well as faded stenciling.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 28 February 2020
Resolved 14 February 2020
Resolution: Lifebuoys re-stenciled and added new retrotape.
01 - Certificates & Documentation › 011 - Ships Certificates › USCG Certificate of Documentation (COD)
Issued 14 February 2020
Resolved
The hailing port of the vessel must be marked on the stern of the vessel. Observed hailing port on stern that did not match with COD and COI. Vsl rep determined that he wishes to keep stern hailing port and will change hailing port on COD and COI. To be done Prior to November 18th, 2020 (next COI).
Action required: 705 - Other - as specified
Due 18 November 2020
Resolved 24 March 2021
Resolution: Received phone call from vessel rep that he was in receipt of new COD which reflects new homeport to NOLA.
11 - Life Saving Appliances › N/A - No Subsystem › Rigid liferafts
Issued 15 November 2018
Resolved
Ensure lifefloats are equipped with proper painter and float free link.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 15 December 2018
Resolved 16 November 2018
Resolution: Cleared to the satisfaction of the Coast Guard
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 15 November 2018
Resolved
Provide repairs to vital fuel transfer system
Action required: 50 - Rectify deficiencies w/in 30 days
Due 15 December 2018
Resolved 15 November 2018
Resolution: Cleared to the satisfaction of the Coast Guard
Engineering › Pressure Vessel › Relief Valve
Issued 8 February 2017
Resolved
Replace port air receiver releif valve. Releif valve is rated for 175 psi and but did not releive at set point.
Action required: 705 - Other - as specified
Due 8 March 2017
Resolved 21 February 2017
Resolution: New relief valves were installed
Stability › Watertight Integrity › Watertight Subdivision Standard
Issued 18 November 2015
Resolved
Failing gasket on engine room escape hatch. Provide sufficient watertight gasket for escape hatch.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 18 November 2015
Resolution: Witnessed corrected gasket before departure.
Operations/Management › Drills/Instruction › Fire
Issued 18 November 2015
Resolved
Perform fire drills at required 2 week interval.
Condition: Invalid
Action required: 705 - Other - as specified
Due 18 November 2016
Resolved 20 November 2017
Electrical › Lighting (emergency) › Battery Operated Lantern
Issued 2 February 2012
Resolved
Emergency light at escape ladder was innoperable
Due 12 February 2012
Resolved 8 February 2012
Resolution: New 12v bulb provided onboard and installed.
Lifesaving › Rocket Parachute Flares › General
Issued 2 February 2012
Resolved
Required number of parachute flares were not on board. Vsl had 6 hand held flares and 6 hand held smoke.
Due 15 February 2012
Resolved 8 February 2012
Resolution: 12 red rocket parachute flares provided onboard,
Lifesaving › Line-Throwing Appliances › Lines
Issued 2 February 2012
Resolved
Auxillary line not onboard
Due 15 February 2012
Resolved 8 February 2012
Resolution: 500 ft of aux line provided onboard.
Communications › Radio Communications › EPIRB
Issued 2 February 2012
Resolved
Hydrostatic release was expired
Due 15 February 2012
Resolved 8 February 2012
Resolution: New hydro static release installed for epirb.
Pollution Prevention/Response › Prevention Equipment › Oily Water Separator (15 ppm)
Issued 9 October 2007
Resolved
Required vessel to have Oily Water Seperator serviced and provide report to the CG verifying OWS is operating at 15PPM.
Due 9 November 2007
Resolved 9 October 2007
Fire Fighting › International Shore Connection › Connection
Issued 9 October 2007
Resolved
Vessel failed to have international shore connection.
Due 9 November 2007
Resolved 9 October 2007
Fire Fighting › International Shore Connection › Connection
Issued 9 October 2007
Resolved
Vessel failed to have international shore connection.
Due 9 November 2007
Resolved 9 October 2007
Fire Fighting › Portable CO2 Fire Extinguisher › Condition
Issued 9 October 2007
Resolved
Vessel issued 835 to have paint locker fire extinguisher servived annually. Must provide servicing report to the local OCMI prior to getting underway.
Action required: 17 - Rectify deficiencies prior to departure
Due 9 October 2007
Resolved 10 October 2007