Records from 2007 to 2025. Most recent: inspection, 8 December 2025.
Documentation record
Registered dimensions (L × B × D)246.6 ft × 52.0 ft × 19.0 ft
Registered tonnagegross 2,540 / net 790
ITC dimensions (L × B × D)246.6 ft × 52.0 ft × 19.0 ft
ITC tonnagegross 2,540 / net 790
BuilderBENDER SHIPBUILDING & REPAIR CO INC · MOBILE, AL, UNITED STATES · built 2007
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portHONOLULU, HI
Trade endorsementsCoastwise, unrestricted, Registry
DocumentationValid · issued 5 December 2025 · expires 31 December 2026
Service, as the file records itIndustrial Vessel
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it790 - Convention (Subpart B), Net Ton
2540 - Convention (Subpart B), Gross Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Inspection history · 30
8 December 2025
Security Plan Review - VSP · Administrative Inspection
Administrative · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 8279383
20 August 2025
ACP Annual Oversight · Annual Inspection · MTSA Verification
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 8214497
19 August 2025
Administrative Inspection
Administrative · Sector Virginia · USCG East District (CGD-E) · Activity 8213392
4 April 2025
Damage Survey
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 8105275
4 November 2024
Administrative Inspection
Administrative · Sector Virginia · USCG East District (CGD-E) · Activity 8029037
25 June 2024
Damage Survey · Administrative Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 7942499
18 December 2023
Annual Inspection · Deficiency Check · Examination of Repairs · ACP Annual Oversight
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7840026
14 November 2023
Deficiency Check
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7825283
13 August 2023
Damage Survey
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7768042
18 July 2023
Damage Survey
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7747809
15 July 2023
Damage Survey
Physical examination · Marine Safety Unit Cape Cod · USCG Northeast District (CGD-NE) · Activity 7743773
16 May 2023
In-Service Inspection
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7677287
18 April 2023
ACP COI Oversight · MTSA/ISPS Verification · Deficiency Check · Re-Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 7671193
17 December 2021
Administrative Inspection
Administrative · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 7369803
25 May 2021
Periodic Inspection · ACP COI Oversight
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 7206204
6 February 2020
Administrative Inspection
Administrative · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 6904082
11 February 2019
Administrative Inspection
Administrative · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 6624034
9 August 2018
MTSA/ISPS Verification · Annual Inspection · ACP Annual Oversight
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 6505867
10 August 2017
Examination of Repairs · ACP COI Oversight · Administrative Inspection · Re-Inspection · MTSA/ISPS Verification
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 6235997
26 January 2017
Type not recorded
No type recorded · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 6077834
20 July 2016
ACP Annual Oversight · Administrative Inspection
Administrative · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 5948622
5 April 2016
Administrative Inspection
Administrative · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 5876286
14 October 2015
Administrative Inspection · MTSA/ISPS Verification · ACP Annual Oversight
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 5743071
6 February 2012
Plan Review (Other than "T")
Administrative · USCG Heartland District (dp) · USCG Heartland District (CGD-H) · Activity 4398395
17 February 2011
ACP COI Oversight · ACP Handover Survey · MTSA/ISPS Verification · Initial Certification · Administrative Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 3947099
14 May 2008
Plan Review (Other than "T")
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 3210214
14 May 2008
Plan Review (Other than "T")
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 3210232
7 May 2008
Plan Review (Other than "T")
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 3201286
7 May 2008
Plan Review (Other than "T")
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 3201301
2 October 2007
Plan Review (Other than "T")
Administrative · USCG Heartland District · USCG Heartland District (CGD-H) · Activity 3073608
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 26 August 2025
Resolved
The following fire protection systems shall be kept in good order so as to ensure their required performance if a fire occurs: .2 fire detection and fire alarm systems.
The smoke detectors adjacent to the starboard steering gear, amidships in the tank farm, and in the main machinery space above the transformer are supported by zip ties.
74 SOLAS (20) II-2/14.2.1.1.2
Action required: 50 - Rectify deficiencies w/in 30 days
Due 26 September 2025
Resolved 4 September 2025
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 26 August 2025
Resolved
Containers, brackets, racks, and other similar stowage locations for life-saving equipment shall be marked with symbols in accordance with the recommendations of the Organization, indicating the devices stowed in that location for that purpose. If more than one device is stowed in that location, the number of devices shall also be indicated. The personal lifesaving equipment in EOS was not stowed with appropriate IMO placards.
74 SOLAS (20) III/20.10
Action required: 50 - Rectify deficiencies w/in 30 days
Due 26 September 2025
Resolved 4 September 2025
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 26 August 2025
Resolved
Electrical installations shall be such that: .3 the safety of passengers, crew and ship from electrical hazards will be ensured. The distribution panel labeled “Tank Farm 208-120V P103” and positioned on the starboard side of the tank farm has a cable drilled in through the side of the box, its purpose is unknown.
74 SOLAS (04) II-1/40.1.3
Action required: 50 - Rectify deficiencies w/in 30 days
Due 26 September 2025
Resolved 4 September 2025
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 26 August 2025
Resolved
Electrical installations shall be such that: .3 the safety of passengers, crew and ship from electrical hazards will be ensured. The hydraulic oil transfer pump on the port side steering gear space is a permanent fixture but not hardwired into ship’s power.
74 SOLAS (04) II-1/40.1.3
Action required: 50 - Rectify deficiencies w/in 30 days
Due 26 September 2025
Resolved 4 September 2025
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 26 August 2025
Resolved
The following fire protection systems shall be kept in good order so as to ensure their required performance if a fire occurs: .3 means of escape systems and appliances. The escape hatch adjacent to the starboard steering gear was seized.
74 SOLAS (20) II-2/14.2.1.1.3
Action required: 10 - Deficiency Rectified
Resolved 26 August 2025
Resolution: Corrected on the spot
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 19 August 2025
Resolved
Your vessel must undergo an annual inspection within the 3 months before or after each anniversary date.
Vessel did not undergo an annual inspection within 3 months after its anniversary date. Vessel must complete annual inspection prior to operations and prior to departure.
46 CFR 91.27-1, 17c
Action required: 17 - Rectify deficiencies prior to departure
Resolved 26 August 2025
Resolution: Completed annual inspection
02 - Structural Conditions › N/A - No Subsystem › Hull damage impairing seaworthiness
Issued 4 April 2025
Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or persons on board. The vessel captain reports a 1 inch hole through the vessel keel cooler housing box.
SOLAS 74 I/11 (a) & (c) (2020 Con. Ed.)
Action required: 17 - Rectify deficiencies prior to departure
Resolved 4 April 2025
02 - Structural Conditions › N/A - No Subsystem › Hull damage impairing seaworthiness
Issued 25 June 2024
Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or persons on board. Whenever an accident occurs to a ship or a defect is discovered, either of which affects the safety of the ship or the efficiency or completeness of its life-saving appliances or other equipment, the master or owner of the ship shall report at the earliest opportunity to the Administration. The vessel Captain reported taking on water through 1 inch by 1/4 inch hole on the vessel's sea chest.
Action required: 17 - Rectify deficiencies prior to departure
Due 25 June 2024
Resolved 26 June 2024
Resolution: Received class survey report attesting to and accepting the temporary repair. Issued CoC.
01 - Certificates & Documentation › 013 - Documents › Fire control plan - all
Issued 26 April 2024
Resolved
Plans and booklets shall be kept up to date; any alterations thereto shall be recorded as soon as practicable. Vessel's Safety Equipment Plan posted in the Pilot House did not match the other Safety Equipment Plans on the vessel. Update and verify vessel's Safety Equipment Plan.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 29 April 2024
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 18 July 2023
Resolved
Ship's service and emergency electrical-generation systems and their auxiliaries vital to the vessel's survivability and safety. #2 SSDG sustained catastrophic failure, and is a redundant vital system. #2 SSDG to be replaced and tested to the satisfaction of attending MI.
Action required: 60 - Rectify deficiencies prior to movement
Resolved 26 April 2024
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 1 May 2023
Resolved
If equipped with ballast tanks, the Master, Owner, Operator, Agent, or person in charge of any vessel must maintain a ballast water management plan to allow for the implementation to understand and follow the vessels BWM strategy and comply with requirements of this subpart. Vessel needs an updated BWM plan that is appropriate for the strategy to comply with US BWM requirements.
Condition: Invalid
Action required: 60 - Rectify deficiencies prior to movement
Resolved 14 November 2023
Resolution: Plan approved by ABS on 30JUN2023
11 - Life Saving Appliances › N/A - No Subsystem › Rescue boats
Issued 1 May 2023
Resolved
Before the ship leaves port and at all times during the voyage, all life saving appliances shall be in the ready for immediate use.
Grab lines need to be re attached to rescue boat.
Condition: Damaged By Earlier Event
Action required: 60 - Rectify deficiencies prior to movement
Resolved 14 November 2023
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 28 April 2023
Resolved
Before the ship leaves port and at all times during the voyage, all life saving appliances shall be in the ready for immediate use.
03 Lifebuoy lifelines are deteriorated and must be replaced.
Condition: Damaged By Earlier Event
Action required: 16 - Rectify deficiencies w/in 14 days
Due 12 May 2023
Resolved 1 May 2023
Resolution: Verified lifebuoy lifelines were replaced.
11 - Life Saving Appliances › N/A - No Subsystem › Rescue boats
Issued 28 April 2023
Resolved
Before the ship leaves port and at all times during the voyage, all life saving appliances shall be in the ready for immediate use.
Rescure Boat is non operational and grab lines are detached.
Condition: Damaged By Earlier Event
Action required: 17 - Rectify deficiencies prior to departure
Resolved 1 May 2023
Resolution: Verified proper operation of the rescue boat.
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 14 October 2015
Resolved
Properly connect waterlight line to life buoy (not to be spliced around grab line).
Action required: 705 - Other - as specified
Due 16 October 2015
Resolved 14 October 2015
Resolution: Corrected on the spot.
Electrical › Electric Supply System (service) › Cable
Issued 14 October 2015
Resolved
Remove cables prevent high voltage doors in ROV van from closing.
Action required: 705 - Other - as specified
Due 16 October 2015
Resolved 14 October 2015
Resolution: Corrected on the spot.
Electrical › Lighting (emergency) › Lighting Fixture
Issued 14 October 2015
Resolved
Properly replace broken E-light bulb in stbd rudder room emergency escape.
Action required: 705 - Other - as specified
Due 16 October 2015
Resolved 14 October 2015
Resolution: Corrected on the spot.
Fire Fighting › Fixed Fire Detection System › Smoke Detectors
Issued 14 October 2015
Resolved
Properly remove plastic wrapping around smoke detector in stbd rudder room (covered to conduct welding).
Action required: 705 - Other - as specified
Due 16 October 2015
Resolved 14 October 2015
Resolution: Corrected on the spot