MAURY USCG vessel records
← All vessels

RBT 316

RBT 316 is a 2006 tank barge. The Coast Guard has recorded 29 inspections since 2006, most recently in March 2025, along with 8 deficiencies and 1 casualty investigation in 2006.

Records from 2006 to 2025. Most recent: inspection, 19 March 2025.

Built
2006
Last inspected
19 March 2025
Documentation
Not in the documentation file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Barge class in Maury's sources begin in 1972.

Inspection record

Last inspected 19 March 2025
…with no type recorded3
Operational controls None recorded without a removal date
Years with a record 18 calendar years (2006–2025)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

803107
Flag
UNITED STATES
Maury page id
psix-803107

Documentation record

Tonnage as PSIX records it1754 - Simplified, Gross Ton
1754 - Simplified, Net Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 1972 to 2026 for this class, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspected as a tow unit · 4

The Coast Guard recorded this vessel and the following in the same inspection activity — normally a tug and the barges in its tow. A recreational or unclassed hull in the same activity is held and not published, so it does not appear here: these lists are a floor, not a complete manifest.

MAC MCGINNIS Towing Vessel · MISLE 78302 · 6 December 2006 · activity 2836049CINCINNATI Towing Vessel · MISLE 562687 · 6 December 2006 · activity 2836049RBT 302 Tank Barge · MISLE 564407 · 6 December 2006 · activity 2836049RBT 310 Tank Barge · MISLE 669268 · 6 December 2006 · activity 2836049

Inspection history · 29

19 March 2025 MTSA Verification · Cargo Tank Internal · Drydock Exam · Internal Structural Exam · COI Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Huntington · USCG Heartland District (CGD-H) · Activity 8096051
14 April 2023 MTSA Verification · Periodic Inspection
Physical examination · Marine Safety Unit Huntington · USCG Heartland District (CGD-H) · Activity 7668625
9 February 2022 MTSA Verification · Annual Inspection
Physical examination · Marine Safety Unit Huntington · USCG Heartland District (CGD-H) · Activity 7393524
1 May 2020 MTSA Verification · Internal Structural Exam · COI Inspection
Physical examination · Marine Safety Unit Huntington · USCG Heartland District (CGD-H) · Activity 6948739
16 May 2019 MTSA Verification · Annual Inspection
Physical examination · Marine Safety Unit Huntington · USCG Heartland District (CGD-H) · Activity 6752096
30 July 2018 Deficiency Check
Physical examination · Marine Safety Unit Huntington · USCG Heartland District (CGD-H) · Activity 6496371
24 July 2018 MTSA Verification · Periodic Inspection
Physical examination · Marine Safety Unit Huntington · USCG Heartland District (CGD-H) · Activity 6490112
1 August 2017 MTSA Verification · Annual Inspection
Physical examination · Marine Safety Unit Huntington · USCG Heartland District (CGD-H) · Activity 6228436
25 June 2017 Type not recorded
No type recorded · Marine Safety Detachment Cincinnati · USCG Heartland District (CGD-H) · Activity 6188770
13 June 2017 Type not recorded
No type recorded · Marine Safety Unit Huntington · USCG Heartland District (CGD-H) · Activity 6175303
2 August 2016 Annual Inspection · MTSA/ISPS Verification
Physical examination · Marine Safety Unit Huntington · USCG Heartland District (CGD-H) · Activity 5960426
7 July 2015 Internal Structural Exam · COI Inspection · MTSA Verification · Drydock Exam · Cargo Tank Internal
Physical examination · Marine Safety Unit Huntington · USCG Heartland District (CGD-H) · Activity 5176917
3 March 2015 Administrative Inspection
Administrative · Marine Safety Unit Huntington · USCG Heartland District (CGD-H) · Activity 5077526
16 September 2014 MTSA Verification · Annual Inspection
Physical examination · Marine Safety Unit Huntington · USCG Heartland District (CGD-H) · Activity 4984977
26 September 2013 MTSA Verification · Periodic Inspection
Physical examination · Marine Safety Unit Huntington · USCG Heartland District (CGD-H) · Activity 4723627
17 August 2012 Annual Inspection · MTSA Verification
Physical examination · Marine Safety Unit Huntington · USCG Heartland District (CGD-H) · Activity 4413801
10 August 2011 Annual Inspection
Physical examination · Marine Safety Unit Huntington · USCG Heartland District (CGD-H) · Activity 4111369
2 November 2010 MTSA Verification · COI Inspection · Internal Structural Exam
Physical examination · Marine Safety Unit Huntington · USCG Heartland District (CGD-H) · Activity 3883837
3 February 2010 MTSA Verification · Annual Inspection
Physical examination · Marine Safety Unit Huntington · USCG Heartland District (CGD-H) · Activity 3675009
5 January 2009 Periodic Inspection · MTSA Verification
Physical examination · Marine Safety Unit Huntington · USCG Heartland District (CGD-H) · Activity 3388911
1 July 2008 Administrative Inspection
Administrative · Marine Safety Unit Huntington · USCG Heartland District (CGD-H) · Activity 3253825
5 March 2008 Annual Inspection · MTSA Verification
Physical examination · Marine Safety Unit Huntington · USCG Heartland District (CGD-H) · Activity 3159512
14 March 2007 Annual Inspection · MTSA Verification
Physical examination · Marine Safety Unit Huntington · USCG Heartland District (CGD-H) · Activity 2887853
6 December 2006 Type not recorded
No type recorded · Marine Safety Detachment Cincinnati · USCG Heartland District (CGD-H) · Activity 2836049
30 November 2006 Administrative Inspection
Administrative · Marine Safety Unit Huntington · USCG Heartland District (CGD-H) · Activity 2831678
17 November 2006 Administrative Inspection
Administrative · Marine Safety Center (MSC) · Activity 2823573
2 November 2006 Security Plan Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2813036
23 March 2006 Internal Structural Exam · MTSA Verification · Hull Examination · Initial Certification · Cargo Tank Internal · Construction Oversight
Physical examination · Marine Safety Detachment Nashville · USCG Heartland District (CGD-H) · Activity 2604114
14 February 2006 Security Plan Amendment Review - ASP
Administrative · Marine Safety Center (MSC) · Activity 2584676

Deficiency record · 8

08 - Alarms › N/A - No Subsystem › Machinery controls alarm
Issued 24 July 2018 Resolved
The combustion air alarm did not sound during operational test of alarms on thermal fluid heater.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 24 August 2018
Resolved 30 July 2018
Resolution: Adjusted diaphragm, alarm working properly
14 - Pollution Prevention › 141 - MARPOL Annex I › Control of discharge
Issued 24 July 2018 Resolved
The meter stick on the #1 starboard cargo tank was bent and did not move freely.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 24 August 2018
Resolved 30 July 2018
Resolution: Replaced meter stick
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Cargo operation
Issued 24 July 2018 Resolved
The valvue stem indicators on the #3 port and starboard tanks were not functioning properly
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 24 August 2018
Resolved 30 July 2018
Resolution: Repaired valve stem indicators
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Gauges, thermometers, etc
Issued 24 July 2018 Resolved
The electronic gauge on the pump engine was not working properly.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 24 August 2018
Resolved 30 July 2018
Resolution: Witnessed proper operation of electronic gauge on pump engine
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Closure Devices
Issued 2 August 2016 Resolved
valve 15, 16 & 17 had valve indicators that were not functioning properly
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 3 August 2016
Resolved 2 August 2016
Resolution: Fixed on the spot
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Nuts
Issued 2 August 2016 Resolved
Multiple nuts on top of the valve stem were loose and easly removed by hand
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 3 August 2016
Resolved 2 August 2016
Resolution: Fixed on the spot
Electrical › Electric Supply System (service) › Cable
Issued 2 August 2016 Resolved
Cables (used to hook up depth sounder) running into a junction box on stern of barge had the installation stripped back and wires were exposed.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 2 August 2016
Resolved 2 August 2016
Resolution: Corrected on the spot
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Flame Screens
Issued 2 August 2016 Resolved
Flame scren missing on external tank labelled "oil" on the stern of the barge.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 2 August 2016
Resolved 2 August 2016
Resolution: replaced missing flame screen

Casualty record · 1

6 December 2006Routine · role: Involved in a Marine Casualty · activity 2836049
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.