Records from 2006 to 2024. Most recent: inspection, 5 September 2024.
Inspection history · 26
5 September 2024
In-Service Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7997005
1 September 2024
PSC B
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7993587
13 January 2023
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7621030
10 January 2023
Administrative Inspection
Administrative · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 7618396
29 December 2022
Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 7614378
26 December 2022
Type not recorded
No type recorded · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7613293
24 October 2022
Deficiency Check
Physical examination · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 7582676
3 October 2022
Administrative Inspection
Administrative · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7570752
2 February 2022
PSC B
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 7382858
17 January 2019
Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 6612028
15 January 2019
Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 6610760
29 November 2018
Ballast Water Examination · PII Safety Exam · ISPS II Exam
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 6586657
12 April 2018
Type not recorded
No type recorded · Sector Virginia · USCG East District (CGD-E) · Activity 6390767
28 October 2017
ISPS II Exam · Ballast Water Examination · PII Safety Exam
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 6293387
28 April 2009
MARPOL Annex I Examination · Ballast Water Examination · PII Safety Exam · MARPOL Annex V Examination · ISPS II Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 3462777
20 June 2008
Deficiency Check
Physical examination · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 3242471
21 April 2008
Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 3189124
16 April 2008
Ballast Water Examination · MARPOL Annex V Examination · PII Safety Exam · ISPS II Exam · MARPOL Annex I Examination
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 3185128
16 October 2007
Ballast Water Examination · ISPS II Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 3080770
6 June 2007
Type not recorded
No type recorded · Sector Virginia · USCG East District (CGD-E) · Activity 2953238
30 March 2007
PII Safety Exam · ISPS III Exam · Ballast Water Examination
Physical examination · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 2898484
26 January 2007
Administrative Inspection
Administrative · Sector Virginia · USCG East District (CGD-E) · Activity 2862352
9 May 2006
Deficiency Check · ISPS II Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 2644421
13 March 2006
Random ISPS/MTSA/PSC · MARPOL Annex V Examination · Ballast Water Examination · MARPOL Annex I Examination
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 2601283
19 January 2006
ISPS II Exam · PII Safety Exam · Ballast Water Examination
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 2569396
19 January 2006
Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 2569426
14 - Pollution Prevention › 141 - MARPOL Annex I › Oil filtering equipment
Issued 2 February 2022
Resolved
Oil filtering equipment referred to in paragraph 1 of this regulation shall be of a design approved by the Administration and shall be such as will ensure that any oily mixture discharged into the sea after passing through the system has an oil content not exceeding 15ppm. PSCO observed non-operational oil content meter.
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 24 October 2022
Resolution: The OWS filter elements have been renewed and tested ensuring that the 15 PPM alarm is operating properly.
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 2 February 2022
Resolved
In a ship in which oil fuel is used the arrangements of the distribution and utilization of oil fuel shall be such as to ensure the safety of the ship and persons on board. PSCO observed excessively oiled accumulations in lagging below purifier room.
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 24 October 2022
Resolution: The vessel identified, secured the leaking equipment, then cleaned and or replaced oily laggings.
Pollution Prevention/Response › Prevention Equipment › Incinerator, Shipboard
Issued 16 April 2008
Resolved
As stated by ship's Chief Engineer and 2nd Engineer, ship is burning oil residue (non-liquid) via ship's incinerator, however the ship's IOPP does not state that the incinerator can be used for such disposal. Prior to return to US upon sailing foreign, have attending Class Surveyor review ship's oil residue procedures and ensure they reflect the IOPP and Management Plan.
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 21 April 2008
Resolution: Rcvd fax report fm ship''s Captain via Germanischer Lloyd surveyor stating that vessel''s sludge system is not connected to the incinerator, and that the crew has been advised not to continue burning residue from holding tanks regardless of the material.
Engineering › Fuel Oil Service System › Piping
Issued 16 April 2008
Resolved
Several pieces of oil-soaked lagging throughout Engineroom: (1) In vicinity of Sludge Pump adjacent to OWS, (2) Lagging around the Fuel Oil Filter for the #3 Ship's Service Generator, and (3) Approx. 90% of lagging in vicinity of Ship's Main Engine. Replace above lagging to the satisfaction of attending Class Surveyor.
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 20 June 2008
Resolution: Rcvd class report.
Pollution Prevention/Response › Prevention Equipment › Oily Water Separator (15 ppm)
Issued 13 March 2006
Resolved
OWS bilge pump is leaking excessivly ( i.e. gasket and or gland bad) bilge water
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 9 May 2006
Resolution: Observed satisfactory operation of OWS bilge pump.
Fire Fighting › Fire Main › Condition
Issued 13 March 2006
Resolved
Fire Main ajacent to escape door in the lower level foward engine space and, fire main ajacent to AFT I.C.C.P Power Supply are both leaking. Make repairs to satisfaction of class
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 9 May 2006
Resolution: Observed newly installed fire main valves and tested satisfactorily.