Records from 2006 to 2026. Most recent: inspection, 17 June 2026.
Inspection history · 25
17 June 2026
PSC B
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 8406597
30 October 2025
PSC B
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 8260773
2 February 2022
In-Service Inspection · Deficiency Check
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7389421
1 February 2022
Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7389416
26 January 2022
Administrative Inspection
Administrative · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7385965
27 October 2021
Administrative Inspection
Administrative · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7340887
30 August 2021
Ballast Water Examination · PSC B
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7300125
20 June 2021
Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 7230427
16 June 2021
Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 7226892
12 April 2021
Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 7173311
11 April 2021
Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 7173353
1 April 2021
Administrative Inspection
Administrative · Sector Virginia · USCG East District (CGD-E) · Activity 7167002
8 February 2021
Administrative Inspection
Administrative · Sector Virginia · USCG East District (CGD-E) · Activity 7137273
28 January 2021
PSC B
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7132164
10 June 2020
Administrative Inspection
Administrative · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6972797
9 June 2020
Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6972247
2 June 2020
Type not recorded
No type recorded · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 6966205
31 May 2020
Type not recorded
No type recorded · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 6964645
22 May 2020
Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 6957833
29 January 2018
Administrative Inspection
Administrative · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 6345723
23 January 2018
PII Safety Exam · Ballast Water Examination · ISPS II Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6341929
8 May 2008
ISPS II Exam · PII Safety Exam
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 3200926
2 February 2006
Type not recorded
No type recorded · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 2578136
2 February 2006
ISPS II Exam · PII Safety Exam
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 2578149
28 January 2006
Type not recorded
No type recorded · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 2575248
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 2 February 2022
Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure that the ship in all respects will remain fit to proceed to sea without danger to ship or persons on board. Vessel suffered loss of propulsion while mooring at Seagirt Terminal.
74 SOLAS (20) I/11(a)
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Due 2 February 2022
Resolved 2 February 2022
Resolution: Received Class Report rectifying this deficiency.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 2 February 2022
Resolved
Means shall be provided to control leaks of flammable liquids. PSCO observed cylinder oil leaks around #1, 2, 3 and 4 main diesel generator cylinder heads and governors. PSCO also observed lube oil leaks around main engine cylinder heads #1, 2, 3, 4, 6, 7 and 9.
74 SOLAS (04) II-2/4.1.1
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 2 February 2022
Resolved 2 February 2022
Resolution: Received Class Report rectifying this deficiency.