Documentation record
Registered dimensions (L × B × D)559.8 ft × 74.0 ft × 40.1 ft
Registered tonnagegross 11,147 / net 11,147
ITC dimensions (L × B × D)559.8 ft × 74.0 ft × 40.1 ft
ITC tonnagegross 13,462 / net 8,791
BuilderVT HALTER MARINE INC · PASCAGOULA, MS, UNITED STATES · built 2006
Hull materialSteel
PropulsionNone
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing portSAN FRANCISCO, CA
Endorsements, as the file codes themcw_un, reg
DocumentationValid · issued 28 July 2026 · expires 31 August 2027
Service, as the file records itTank Barge
Hull formbarge (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it11147 - Regulatory (Subpart C or D), Gross Ton
13462 - Convention (Subpart B), Gross Ton
27023 - Dead Weight, Gross Ton
32634 - Displacement, Gross Ton
11147 - Regulatory (Subpart C or D), Net Ton
8791 - Convention (Subpart B), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Inspection history · 60
18 February 2026
Administrative Inspection
Administrative · Sector Miami · USCG Southeast District (CGD-SE) · Activity 8312348
18 February 2026
Administrative Inspection · Damage Survey
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 8312667
18 February 2026
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 8317115
15 January 2026
Vessel Attendance · Administrative Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 8305887
25 October 2025
In-Service Inspection · Deficiency Check · Examination of Repairs
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 8258860
25 October 2025
Type not recorded
No type recorded · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 8259747
28 July 2025
MARPOL Annex II Examination · MTSA Verification · Annual Inspection
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 8191640
9 May 2025
Damage Survey
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 8131940
13 December 2024
Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 8047142
18 September 2024
Administrative Inspection
Administrative · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 8005085
1 May 2024
Internal Structural Exam
Physical examination · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 7905601
5 May 2023
Periodic Inspection · Administrative Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7681847
28 June 2022
Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7491978
24 May 2021
Administrative Inspection · COI Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7213870
26 April 2021
Internal Structural Exam · Drydock Exam · Administrative Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7176125
16 June 2020
Administrative Inspection · Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6978238
16 November 2019
In-Service Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6859223
15 November 2019
Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6871869
29 July 2019
Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6766786
2 July 2019
MTSA Verification · Annual Inspection · Administrative Inspection · Internal Structural Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6734139
20 August 2018
Periodic Inspection · Deficiency Check
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 6503560
29 May 2018
Damage Survey
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6427938
18 July 2017
Annual Inspection · Administrative Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6212662
20 December 2016
In-Service Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6060013
5 November 2016
Administrative Inspection
Administrative · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6052900
24 May 2016
Internal Structural Exam · Hull Examination · MARPOL Annex IV Survey · Cargo Tank Internal · COI Inspection
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 5885399
10 February 2016
Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 5812800
17 June 2015
Administrative Inspection
Administrative · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 5150386
31 May 2015
Type not recorded
No type recorded · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 5141586
11 May 2015
Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 5108601
26 August 2014
Administrative Inspection
Administrative · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 5123253
23 June 2014
Internal Structural Exam
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 4897703
1 April 2014
Plan Review (Other than "T")
Administrative · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 4965170
17 June 2013
Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 4598139
22 October 2012
Type not recorded
No type recorded · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 4471618
19 October 2012
Administrative Inspection
Administrative · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 4467611
17 August 2012
Administrative Inspection
Administrative · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 4413940
16 July 2012
Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 4360980
9 May 2012
Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 4312540
23 April 2012
Type not recorded
No type recorded · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 4293641
31 January 2012
Type not recorded
No type recorded · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 4235628
3 August 2011
Deficiency Check
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 4109262
22 July 2011
In-Service Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 4104464
16 June 2011
Administrative Inspection · Internal Structural Exam · MARPOL Annex I Examination · MARPOL Annex IV Survey · Hull Examination · COI Inspection · MARPOL Annex II Examination
Physical examination · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 4037559
10 December 2010
MARPOL Annex I Examination · Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 3908352
6 August 2010
Type not recorded
No type recorded · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 3903874
28 February 2010
Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 3715182
12 January 2010
Annual Inspection · Internal Structural Exam
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 3659129
5 January 2010
Administrative Inspection
Administrative · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 3659517
5 January 2010
Type not recorded
No type recorded · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 3661138
27 August 2009
Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 3578557
13 July 2009
Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 3533710
6 June 2009
Examination of Repairs
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 3659646
3 February 2009
MTSA Verification · Periodic Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 3402260
9 January 2009
Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 3391474
15 October 2008
Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 3359726
6 November 2007
MARPOL Annex I Examination · Ballast Water Examination · MTSA Verification · Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 3094025
14 March 2007
Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 2887704
19 December 2006
Plan Review (Other than "T") · Ballast Water Examination
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 2856617
7 October 2004
MTSA Verification · Hull Examination · MARPOL Annex II Examination · Plan Review (Other than "T") · Drydock Exam · Welding Related Inspections Qualification Testing · Initial Certification · Ballast Water Examination · Internal Structural Exam · Cargo Tank Internal · Construction Oversight · MARPOL Annex I Examination · Initial Construction-Excluding Oversight
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 2826393
02 - Structural Conditions › N/A - No Subsystem › Cargo area segregation
Issued 18 February 2026
Resolved
46 CFR 32.60-10 (c)(2):No openings to cargo tank shall be permitted. #1 port cargo tank is leaking into ballast tank. ABS survey and repair plan requested. Complete approved repairs to the satisfaction of CG Marine Inspector.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 4 March 2026
Resolved 26 February 2026
Resolution: Visually inspected final weld repair and witnessed soapy water test with cargo tank pressed up to 1.5 psi
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 25 October 2025
Resolved
46 CFR 32.45-1; 46 CFR 111.10-4; 705c Prior to Cargo Operations
Operating generators must provide a continuous and uninterrupted source of power for the ships service load under normal operating conditions.
It was reported the STBD generator suffered a fire while conducting cargo operations. Verifications must be made, to the satisfaction of the Coast Guard, that the damage was limited to the stbd generator and the port generator can safely be operated prior to conducting cargo operations.
Action required: 705 - Other - as specified
Due 25 October 2025
Resolved 25 October 2025
Resolution: Marine Inspectors, IO, and Class (ABS) attended vessel this date. Observed stbd gen isolated from ship. MI and Class observed port gen under load with approximately 500 kw to confirm capability of resuming cargo ops. Risk mitigation plan uploaded to docs.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 25 October 2025
Resolved
46 CFR 32.45-1; 46 CFR 111.10-4; 17c
Operating generators must provide a continuous and uninterrupted source of power for the ships service load under normal operating conditions.
It was reported the STBD generator suffered a fire while conducting cargo operations. Repairs must be made to the stbd generator to the satisfaction of the Coast Guard, prior to departure from the Port of Tampa.
Action required: 17 - Rectify deficiencies prior to departure
Due 25 October 2025
Resolved 8 November 2025
Resolution: Marine Inspector observed satisfactory repairs and replacement in kinds of electrical equipment to the Stbd Generator. All tests were sat. No further action.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 15 June 2021
Resolved
Prior to MSC approval of Cargo Authority Attachment, vessel shall be restricted of operations under current approved Cargo Authority Attachment.
Condition: Invalid
Action required: 705 - Other - as specified
Due 6 July 2021
Resolved 4 January 2022
Resolution: Signed and issued COF.
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Other (cargo)
Issued 24 May 2021
Resolved
Vessel's IG system is not operational.
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Due 1 July 2021
Resolved 25 May 2021
Resolution: Fixed and tested all alarms/shutdowns for IG system.
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Other (cargo)
Issued 24 May 2021
Resolved
Inboard air receiver relief valve does not actuate from any pressure more than 10 percent above or 10 percent below that for which the relief valve is marked.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 7 June 2021
Resolved 15 June 2021
Resolution: Showed proof of functioning pv-valve.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 2 July 2019
Resolved
ach tank vessel must undergo internal structural examinations in accordance with the intervals set forth in table 31.10-21(a). Double hull barge with external framing (cargo tank), no more than three years may lapse between any two examinations. The vessel's internal structural exam was required to be completed by 30Jun2019. This deficiency must be rectified prior to movement. Movements may be authorized on a case by case basis. Contact Duty Marine Inspector at [phone withheld].
Action required: 60 - Rectify deficiencies prior to movement
Resolved 3 July 2019
Resolution: ISE Complete
Deck/Cargo › Inert Gas System › IGS Scrubber
Issued 29 May 2018
Resolved
Make permanent repairs to the overboard discharge pipe on the barge's inert gas scrubber system piping by next dry-dock.
Action required: 705 - Other - as specified
Due 20 June 2021
Resolved 24 August 2018
Resolution: Piping section replaced and hydro tested. All sat.
Fire Fighting › Fixed Deck Foam System › Piping
Issued 18 July 2017
Resolved
Fixed foam sprinklers had 2 clogged nozzles.
Action required: 705 - Other - as specified
Due 18 July 2017
Resolved 18 July 2017
Resolution: Nozzles cleaned and tested prior to MI departure.
Engineering › Diesel Engine (auxiliary) › Piping (exhaust)
Issued 11 May 2015
Resolved
Provide adequate lagging to cover exhaust on turbo for auxiliary (hotel) generator.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 11 June 2015
Resolved 17 May 2015
Resolution: Lagging was installed on exhaust covering all exposed areas.
Electrical › Lighting (service) › Lighting Fixture
Issued 11 May 2015
Resolved
Replace in kind the explosion proof lighting located near portside manifold. Isolate fixture prior to cargo operations.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 11 June 2015
Resolved 17 May 2015
Resolution: Explosion proof lighting replaced in area identified.
Electrical › Electric Supply System (service) › Cable
Issued 11 May 2015
Resolved
Remove dead end wiring from IG compartment overhead.
Action required: 705 - Other - as specified
Due 11 June 2015
Resolved 17 May 2015
Resolution: Dead end wiring was routed and sealed in a junction box.
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 11 May 2015
Resolved
Replace float lights for life rings with the approved type.
Action required: 705 - Other - as specified
Due 11 June 2015
Resolved 17 May 2015
Resolution: Type approval for float lights identified was provided.
Fire Fighting › Portable CO2 Fire Extinguisher › Mounting Bracket
Issued 11 May 2015
Resolved
Replace fire extinguisher brackets with approved type for each type of extinguisher.
Action required: 705 - Other - as specified
Due 11 June 2015
Resolved 17 May 2015
Resolution: All portable extinguishers were placed with approved brackets.
Construction/Loadline › Hull › Hull Plating
Issued 23 June 2014
Resolved
Complete Internal Structural Examination and Thermal Fluid Heater Inspection to the satisfaction of the attending USCG Marine Inspector prior to departure.
Action required: 705 - Other - as specified
Due 26 June 2014
Resolved 26 June 2014
Resolution: Completed ISE and Thermal Fluid Heater Inspection.
Documentation › Manuals/Policy Documentation › Crude Oil Washing Operations/Equipment Manual
Issued 22 July 2011
Resolved
COW manual requires approval from ABS (ABS stamped "APPROVED" - an outstanding requirement that was missed in the review process (item P-006). Prior to conducting cargo operations that only require COW (this does not impact non-crude oil cargoes).
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 16 July 2012
Resolution: Def Cleared.
Documentation › Certificates/Documents › IOPP Certificate
Issued 22 July 2011
Resolved
To use the Crude Oil Wash (COW) system, the IOPP needs to be updated to reflect the system approval.
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 16 July 2012
Resolution: Def cleared.
Documentation › Certificates/Documents › Certificate of Inspection
Issued 22 July 2011
Resolved
Provide onboard an updated COI Cargo Authority Attachment (CAA) prior to the carriage of crude oil.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 16 July 2012
Engineering › Pressure Vessel › Shell Plate
Issued 15 July 2011
Resolved
Have the 2 unfired pressure vessels located on deck for teh FF Foam Extinguishing System undergo a 1.5 MAWP hydrostatic test to the satisfaction of an attending CG marine inspector. Both pressure vessels must not return to pressurized service until itme has been cleared. 46 CFR 60.10-5(b)(3)
Due 15 August 2011
Resolved 3 August 2011
Resolution: Witnessed 300 psi hydro of both pressure vessels.
Engineering › Pressure Vessel › Shell Plate
Issued 16 June 2011
Resolved
A certified NBBI inspector must examine both UPV's located on deck IWO foam station near starboard presentation flanges and attest to their condition and any approved repair proposals prior to those vessel being placed back into service. All cargoes requiring foam fire protection are not authorized to be carried until this defeciency has been cleared by attending CG marine inspector.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 16 July 2011
Resolved 15 July 2011
Resolution: Vessel operator did not have a NBBI inspector attend the inspection of pressure vessels (API-510 code inspector instead). Must prove alternate inspector''s findings with 1.5 hydrostatic test. Issuing CG-835 item this date to require the hydro test.
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Relief Valve
Issued 16 June 2011
Resolved
Cargo safety relief valves not annually tested as rqr'd. The vsl's crew typically conducts this test and cargo is needed as the medium. The vsl must provide proof of proper testing for all 14 cargo safety relief valves prior to offloading cargo.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 16 July 2011
Resolved 27 June 2011
Deck/Cargo › Cargo Heating › General
Issued 10 December 2010
Resolved
Demonstrate the proper operation of the thermal fluid heater prior to the operation of the thermal fluid heater.
Action required: 705 - Other - as specified
Due 13 January 2011
Resolved 15 December 2010
Resolution: Attending Inspector witnessed proper operation of thermal fluid heater.
Deck/Cargo › Cargo Heating › General
Issued 10 December 2010
Resolved
Install insulation blankets on thermal fluid heater supply and return lines.
Action required: 705 - Other - as specified
Due 13 January 2011
Resolved 15 December 2010
Resolution: Installed insulation blankets on thermal fluid heater supply and return lines. Repairs complete to the satisfaction of the attending Inspector.
Operations/Management › Vessel Safety Management › Maintenance of Ship/Equipment
Issued 5 January 2010
Resolved
Conduct Internal Structural Examination upon arrival in Sector LA/LB, and not later than 13Jan10
Action required: 705 - Other - as specified
Due 13 January 2010
Resolved 12 January 2010
Resolution: Conducted ISE on 01/12/2010