MAURY USCG vessel records
← All vessels

CHABRIA SEA

Built
2006
Last inspected
15 July 2025
Documentation
Valid · NVDC file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Barge class in Maury's sources begin in 1972.

Inspection record

Last inspected 15 July 2025
…with no type recorded7
Operational controls None recorded without a removal date
Years with a record 18 calendar years (2006–2025)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

850407
Flag
UNITED STATES
Maury page id
psix-850407

Documentation record

Registered dimensions (L × B × D)308.0 ft × 54.0 ft × 16.0 ft
Registered tonnagegross 2,235 / net 2,235
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderTRINITY MARINE PRODUCTS INC · ASHLAND CITY, TN, UNITED STATES · built 2006
Hull materialSteel
PropulsionUNSPECIFIED
Hull shapeBox
Hull configurationMonohull
Hailing portPORTLAND, OR
Endorsements, as the file codes themcw_un, reg_nfv
DocumentationValid · issued 17 February 2026 · expires 31 March 2027
Service, as the file records itTank Barge
Hull formbarge (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it2235 - Simplified, Gross Ton
2235 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Professional
The full record for this vessel

Behind this panel: 42 inspections, each with its date, unit and type; 35 deficiencies with the resolution recorded against each; operational controls, none recorded without a removal date; 4 other vessels inspected with it; no other recorded names; the documentation record: dimensions, tonnage, builder, hailing port and endorsements. Every line is a record the Coast Guard wrote; the counts above are the same counts as in the summary, and they are free.

Professional is $39 a month or $299 a year, or $19.99 a month locked for life at the founding rate, for the first 200 subscribers. It unlocks every detail section on every vessel page, fleet watch tied to your account, and ownership records on request. Already a subscriber? Sign in.

Maury does not score, rate or grade vessels, at any price.

Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 1972 to 2026, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspected as a tow unit · 4

The Coast Guard recorded this vessel and the following in the same inspection activity — normally a tug and the barges in its tow. A recreational or unclassed hull in the same activity is held and not published, so it does not appear here: these lists are a floor, not a complete manifest.

LIGHTNING Towing Vessel · MISLE 1211246 · 19 July 2023 · activity 7747313NEPTUNE Towing Vessel · MISLE 371018 · 12 September 2015 · activity 5717967MADDIE K Towing Vessel · MISLE 165701 · 7 October 2010 · activity 3907121HMS LIBERTY Towing Vessel · MISLE 164098 · 24 March 2010 · activity 3702832

Inspection history · 42

15 July 2025 COI Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 8163252
30 April 2025 Cargo Tank Internal · Drydock Exam · Internal Structural Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 8123256
29 October 2024 Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 8025861
19 July 2023 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 7747313
22 June 2023 MTSA Verification · Periodic Inspection · Internal Structural Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7720556
28 July 2022 Annual Inspection · MTSA Verification
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7518742
27 July 2021 Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7269753
11 August 2020 MTSA Verification · COI Inspection · Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7029368
17 June 2020 Drydock Exam · Examination of Repairs · Internal Structural Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6979687
6 December 2019 Damage Survey
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6868614
5 November 2019 MTSA Verification · Periodic Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6850048
29 July 2019 Bulk Liquid Transfer Monitor
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6766372
9 October 2018 Annual Inspection · MTSA Verification
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6572042
18 October 2017 MTSA Verification · Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6290349
30 January 2017 Type not recorded
No type recorded · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 6080126
26 October 2016 Cargo Tank Internal · MTSA Verification · Deficiency Check · COI Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6027194
10 December 2015 MTSA Verification · Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 5778833
12 September 2015 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 5717967
14 August 2015 Load Line/Change of Employment
Administrative · Sector Delaware Bay · USCG East District (CGD-E) · Activity 5216003
2 July 2015 Drydock Exam
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 5170575
8 May 2015 Cargo Tank Internal
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 5155816
19 March 2015 Type not recorded
No type recorded · Sector Delaware Bay · USCG East District (CGD-E) · Activity 5089884
17 February 2015 Load Line/Change of Employment
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 5070047
29 October 2014 MTSA Verification · Periodic Inspection · Deficiency Check · Administrative Inspection · Internal Structural Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 5013827
1 April 2014 Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 4826868
25 January 2014 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 4789782
8 January 2014 Deficiency Check · MTSA Verification · Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 4778751
11 October 2012 MTSA Verification · Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 4462005
2 December 2011 Deficiency Check · Administrative Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 4200412
3 November 2011 Internal Structural Exam · Administrative Inspection · Deficiency Check · COI Inspection · Plan Review (Other than "T")
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 4181468
22 December 2010 Annual Inspection · Deficiency Check · MTSA Verification
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 3914688
15 October 2010 Examination of Repairs · Damage Survey
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 3872102
7 October 2010 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 3907121
24 March 2010 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 3702832
18 December 2008 Annual Inspection · MTSA Verification
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 3381729
13 November 2007 Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 3097388
24 August 2007 Deficiency Check · Administrative Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 3037055
1 February 2007 Administrative Inspection
Administrative · Commandant (CG-CVC) · Activity 2865657
4 January 2007 COI Inspection · MTSA Verification
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 2849921
20 December 2006 Administrative Inspection · Load Line/Change of Employment
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 2843767
30 November 2006 Cargo Tank Internal · Internal Structural Exam · Construction Oversight · Hull Examination · Initial Certification · MTSA Verification
Physical examination · Marine Safety Detachment Nashville · USCG Heartland District (CGD-H) · Activity 2831419
1 November 2006 Security Plan Amendment Review - ASP
Administrative · Marine Safety Center (MSC) · Activity 2812378

Deficiency record · 35

09 - Working and Living Conditions › 092 - Working Conditions › Guards - fencing around dangerous machinery parts
Issued 15 July 2025 Resolved
...all rotating machinery capable of injurying personnel must be provided with adequate covers or guards. Observed 02 exhaust fans in the thermal fluid heater space and 01 exhaust fan in the generator space with no protective casings or guards with rotating fan blades. 46 CFR 32.35-1 46 CFR 58.01-20
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 7 August 2025
Resolution: Received photo evidence of rectification.
04 - Emergency Systems › N/A - No Subsystem › Safe areas
Issued 22 June 2023 Resolved
Electric installations on vessels must ensure: (1) Maintenance of services necessary for safety under normal and emergency conditions. Number 2 generator appears to be missing an e-stop. Provide evidence accordingly 46CFR111.01-1 Prior to Cargo Operations
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 29 June 2023
Resolved 23 June 2023
Resolution: Vessel sent attached evidence of e-stop repair
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 22 June 2023 Resolved
Electric installations on vessels must ensure: (1) Maintenance of services necessary for safety under normal and emergency conditions. Air Receiver's contactor was found faulty and requires repair. Prior to Cargo Operations 46CFR111.01-1
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 29 June 2023
Resolved 23 June 2023
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 22 June 2023 Resolved
All safety and relief valves for use on pressure vessels or piping systems shall be designed to meet the protection and service requirements for which they are intended and shall be set to relieve at a pressure which does not exceed the “maximum allowable working pressure” of the pressure vessel or piping system. No gauge to tell what pressure the air receiver is relieving at. Prior to Cargo Operations 46CFR54.15-10
Condition: Design Flaw
Action required: 705 - Other - as specified
Due 29 June 2023
Resolved 23 June 2023
Resolution: Vessel submitted evidenve of repair.
02 - Structural Conditions › N/A - No Subsystem › Decks - corrosion
Issued 22 June 2023 Resolved
Scantlings, material, and workmanship, subdivision of cargo spaces, fitting of cofferdams, and testing of tanks shall be at least equivalent to the requirements of the American Bureau of Shipping or other recognized classification society. A pinhole was found in the goose neck vent pipe that requires temporary repair. 46 CFR 32.60-1 Prior to Cargo Operations
Condition: Design Flaw
Action required: 705 - Other - as specified
Due 29 June 2023
Resolved 25 June 2023
Resolution: Repair on pinhole has been effected as discussed previously.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Other (load lines)
Issued 28 July 2022 Resolved
replace all gaskets on void spaces
Action required: 16 - Rectify deficiencies w/in 14 days
Due 11 August 2022
Resolved 26 August 2022
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 28 July 2022 Resolved
33 cfr 83.20, make nav lights functional and intrinsically safe.
Action required: 705 - Other - as specified
Due 28 July 2022
Resolved 29 July 2022
Resolution: prior to carrying cargo of a flash point 140 degrees or below.
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Other (cargo)
Issued 28 July 2022 Resolved
46 cfr 111.105-31/17- make all connections within the hazardous zone intrinsically safe.
Action required: 705 - Other - as specified
Due 28 July 2022
Resolved 29 July 2022
Resolution: Prior to carrying cargo of a flash point 140 degrees or below vessel must make all connection within the hazardous zone intrinsically safe.
05 - Radio Communications › N/A - No Subsystem › Other (radio communication)
Issued 11 August 2020 Resolved
Stations in the maritime service must be licensed by the FCC either individually or by fleet. Vessel's radio station was not licensed.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 25 August 2020
Resolution: Proof of valid certificate received.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 11 August 2020 Resolved
On all tank vessels, cargo pumps shall be designed and installed as to minimize the possibility of sparking. Oil was leaking near the turbo mount on the port aft cargo pump engine. Rectify prior to using pump during operations.
Action required: 705 - Other - as specified
Resolved 12 August 2020
Resolution: Gasket was changed and no leak was discovered while running the engine.
Construction/Loadline › Penetrations › Gasket
Issued 26 October 2016 Resolved
Scantlings, material, and workmanship, subdivision of cargo spaces, fitting of cofferdams shall be at least equivalent to the requirements of the American Bureau of Shipping. During the inspection several of the gaskets for the hatches on the void spaces were found deteriorated or missing. 46 CFR 32.60-1(a)
Action required: 705 - Other - as specified
Due 9 November 2016
Resolved 7 November 2016
Resolution: Rep sent shipping papers for replacement gaskets for void hatches. Cleared.
Electrical › Electric Generation Source (service) › Generator
Issued 26 October 2016 Resolved
Each generator prime mover must have an overspeed device that is independent of the normal operating governor and adjusted so the speed cannot exceed the maximum rated speed by more than 15%. Each prime mover must shut down automatically upon loss of lubricating pressure to the generator bearings if the generator is directly coupled to the engine. 46 CFR 111.12-1
Action required: 705 - Other - as specified
Due 2 November 2016
Resolved 2 November 2016
Resolution: Witnessed lube oil and overspeed shutdowns on (01) of the generators.
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Relief Valve
Issued 10 December 2015 Resolved
Cargo pump relief valves shall be tested at least once each year to determine that they function satisfactorily at the pressure at which they are set to open. Relief valve tests were overdue. Test and provide documentation.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 4 January 2016
Resolved 31 December 2015
Resolution: Received test report.
Pollution Prevention/Response › Prevention Equipment › Cargo Monitor/Control System
Issued 10 December 2015 Resolved
Cargo pump pressure gage shall be tested at least once a year for accuracy. Cargo pump pressure gage tests were overdue. Test and provide documentation.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 4 January 2016
Resolved 31 December 2015
Resolution: Received calibration receipt.
Electrical › Electrical Distribution System (service) › Ground Detection
Issued 10 December 2015 Resolved
There must be ground detection for each power or lighting system that is isolated from the ship's service power. Ground detection lights were burned out at the 240-V distribution panel (barge house) and at the 120-v panel (generator room). Replace bulbs in kind and verify functionality of ground detection unit.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 4 January 2016
Resolved 18 December 2015
Resolution: Verified ground detection is working properly.
Construction/Loadline › Hull › Girder
Issued 2 July 2015 Resolved
NAW01 Make proper permanent repairs to buckled web in fwd stbd rake to satisfaction of CG MI
Condition: Damaged By Earlier Event
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 13 July 2015
Resolution: Web crop & renew satisfactory.
Construction/Loadline › Hull › Bottom Plating
Issued 2 July 2015 Resolved
NAW02: Make proper permanent repairs to inset in bottom plating on stbd void #1 2nd bay fwd from aft manhole to satisfaction of CGMI.
Condition: Damaged By Earlier Event
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 13 July 2015
Resolution: Insert plate in bottom plating was installed.
Construction/Loadline › Hull › Longitudinal Frame
Issued 29 October 2014 Resolved
Complete ISE work list items dated 10/29/2014 prior to next credit drydock on 06/30/2015.
Due 30 June 2015
Resolved 13 July 2015
Resolution: ISE items completed at Philly Shipyard
Engineering › Pressure Vessel › Relief Valve
Issued 28 October 2014 Resolved
The markings shall be IAW this chapter for devices covered by 46 CFR 54.15-10. The relief device on the pressure vessel is not marked with its MAWP. 46CFR 54.15-1(b).
Due 12 November 2014
Resolved 19 December 2014
Resolution: Vessel provided documentation showing that they received a new pressure relief valve and conducted a satisfactory test.
Electrical › Electrical Distribution System (service) › Ground Detection
Issued 8 January 2014 Resolved
Vessel must ensure the 120v panel on the main switchboard has operable ground detection. Provide electricians report, identifying cause and resolution to the electrical problem. 46CFR111.05-21 Must be corrected prior to operating in Restricted Vis.
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Resolved 9 January 2014
Resolution: The technician found that an improperly installed retaining screw on the pauluhn plug which fed the light caused a bond between one leg and the ground.
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Cargo Pump
Issued 8 January 2014 Resolved
Vessel must show proper operation of emergency manual shutdown on FWD STBD engine. 46CFR32.50-35 Prior to using pump for cargo ops.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 9 January 2014
Resolution: Witnessed operational testing of emergency shutdown of the forward starboard cargo pump. Satisfactory test completed.
Electrical › Lighting (service) › Lighting Fixture
Issued 8 January 2014 Resolved
Vessel must ensure that all stern lights and all anchor lights are operational. 33CFR83.24(e)(2) & 33CFR83.30(a) Prior to operating in restricted vis.
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Resolved 9 January 2014
Resolution: GME provided report stating that navigation lights are operational and burning brightly.
Electrical › Lighting (service) › Lighting Fixture
Issued 8 January 2014 Resolved
Ensure all deck lights are operational and provide electrician report addressing ongoing light failure.
Condition: Improper Installation
Due 8 February 2014
Resolved 9 January 2014
Resolution: Vessel deck lights are all energized and burning brightly. Vessel is going to change out deck lighting configuration to LED type lights which is more durable and better suited for that particular barge.
Electrical › Electrical Distribution System (service) › Wiring
Issued 8 January 2014 Resolved
Remove unused electrical wiring and inop battery chargers in machinery space (electrical hazard). 46CFR111.60-11
Condition: Improper Installation
Due 8 February 2014
Resolved 9 January 2014
Resolution: GME provided documentation showing the removal of old battery chargers that was creating a electrical hazard. Battery chargers and wiring have been removed from machinery space.
Electrical › Electrical Distribution System (service) › Panelboard
Issued 8 January 2014 Resolved
240v panel in crew quarters does not have ground detection after the transformer. Submit plans to Marine Safety Center for review and install approved ground detection system. 46CFR111.05-21. Extended due date from 08FEB to 31MAR.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 31 March 2014
Resolved 1 April 2014
Resolution: Inspected satisfactory repairs completed IAW MSC Plan Review.
Electrical › Electrical Distribution System (service) › Wiring
Issued 3 November 2011 Resolved
Provide plans to replace/install heat tape on overboard grey water line to remove temporary extension cord.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 30 November 2011
Resolved 17 November 2011
Resolution: Witnessed proper installation of electrical wiring to heat tape on gray water tank.
Electrical › Electric Generation Source (service) › Generator
Issued 3 November 2011 Resolved
Provide technician to conduct overspeed and low lube oil trips on generators.
Action required: 705 - Other - as specified
Due 31 January 2012
Resolved 2 December 2011
Resolution: The generators are not equipped with overspeed devices. A 6 month grace period has been granted by Cargo Branch [name withheld].
Construction/Loadline › Hull › Side Shell
Issued 15 October 2010 Resolved
C/R inset in the #3 starboard wing tank from seam to seam where damaged between bay #1 and bay #2 as discussed with the vessel representative and to the satisfaction of an attending Coast Guard Marine Inspector.
Action required: 705 - Other - as specified
Due 15 November 2010
Resolved 10 November 2010
Resolution: Visually inspected and witnessed pressure test of the affected area. the repair was performed IAW NVIC 7-68
Construction/Loadline › Hull › Transverse Frame
Issued 15 October 2010 Resolved
C/R damaged transverse web frame between bay #1 and bay #2 in the #3 starboard wing tank from above ssl #5 to the bilge knuckle as discussed with the vessel representative and to the satisfaction of an attending Coast Guard Marine Inspector.
Action required: 705 - Other - as specified
Due 15 November 2010
Resolved 10 November 2010
Resolution: Visually inspected and witnessed pressure test of the affected area. The repair was performed IAW NVIC 7-68.
Construction/Loadline › Hull › Transverse Frame
Issued 15 October 2010 Resolved
C/R damaged transverse web frame between bay #2 and bay #3 in the #3 starboard wing tank from above SSL #5 to the bilge knuckle as discussed with the vessel representative and to the satisfaction of an attending Coast Guard Marine Inspector.
Action required: 705 - Other - as specified
Due 15 November 2010
Resolved 10 November 2010
Resolution: Visually inspected and witnessed pressure test of the affected area. The repair was performed IAW NVIC 7-68.
Construction/Loadline › Hull › Longitudinal Frame
Issued 15 October 2010 Resolved
C/R damaged SSL #5 and SSL #6 in #3 starbaord wing tank from Bay #1 to Bay #3 as discussed with the vessel representative and to the satisfaction of an attending Coast Guard Marine Inspector.
Action required: 705 - Other - as specified
Due 15 November 2010
Resolved 10 November 2010
Resolution: Visually inspected and witnessed pressure test of the affected area. The repair was performed IAW NVIC 7-68.
Documentation › Safety/Response Plans/Programs › Vessel Response Plan
Issued 1 February 2007 Resolved
The approved VRP for this T/B does not list approval for COTP Zone NY. The VRP approval letter dtd 18 Dec 06 did not include COTP Zone NY. The POC at Harley Marine Service contacted the VRP program regarding add zone COTP NY revisions received on 31 Jan 07. The revision is under review and will be completed within a 3-4 week period. (Reference VRP control #02409, Correspondence log.)
Due 1 March 2007
Resolved 13 November 2007
Resolution: Provided.
Deck/Cargo › Holds/Tanks › Portable Gas Measuring Equipment
Issued 4 January 2007 Resolved
Provide proof of combustible gas indicator onboard prior to manned operations
Due 3 February 2007
Resolved 5 January 2007
Resolution: Received copy of receipt for purchase of CGI meter and test gas
Electrical › Electric Generation Source (service) › Generator
Issued 4 January 2007 Resolved
Provide proof of operation of second generator prior to manned operations
Due 3 February 2007
Resolved 5 January 2007
Resolution: Received statement from port engineer attesting to proper operation of second engineer
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Cargo Pump
Issued 30 November 2006 Resolved
Provide proof of cargo pump engine wiring harness and alternator meeting 46 CFR 111.105-31(l) N.E.C. class 1 / division 1 as per USCG D8(m) policy letter 02-2005 NLT 31AUG07.
Action required: 705 - Other - as specified
Due 31 August 2007
Resolved 24 August 2007
Resolution: Using guidance from MSC memorandum witch stated five options for vessel to become compliant. Cargo authority was change restricting the vessel to grade "D" cargos with aflashpoint of 140 degrees and higher, and also grade "E" cargos.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.