Inspection history · 13
23 June 2026
Administrative Inspection · COI Inspection · Deficiency Check
Physical examination · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 8381975
21 October 2025
Drydock Exam · Administrative Inspection · Internal Structural Exam · Deficiency Check
Physical examination · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 8257874
24 September 2025
Administrative Inspection · DAPI Audit · Annual Inspection
Physical examination · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 8204042
18 June 2025
Administrative Inspection · Deficiency Check
Physical examination · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 8165498
13 September 2024
Annual Inspection
Physical examination · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 8000704
10 July 2024
Deficiency Check
Physical examination · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 7955508
14 September 2023
Deficiency Check · Annual Inspection
Physical examination · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 7778857
12 September 2022
Administrative Inspection · Annual Inspection
Physical examination · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 7557504
27 May 2021
Initial Certification · Administrative Inspection · Deficiency Check
Physical examination · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 7208724
29 June 2016
Type not recorded
No type recorded · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 5942042
15 November 2006
Administrative Inspection
Administrative · Marine Safety Center (MSC) · Activity 2821429
2 December 2003
Security Plan Review - ASP
Administrative · Marine Safety Center (MSC) · Activity 1958096
8 January 1999
Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 222706
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Gauges, thermometers, etc
Issued 23 June 2026
No resolution recorded
Machinery alarms for the main engines must be tested twice in 5 years with no more than 3 years between tests. Prove proper operation of the low lube oil pressure and high jacket water temperature alarms to the attending marine inspector
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 23 July 2026 — due date passed with no resolution recorded
09 - Working and Living Conditions › 092 - Working Conditions › Protection machines/parts
Issued 23 June 2026
Resolved
Exposed hazards such as rotating machinery must be protected by guards. The alternator and bilge pump pulleys on the front of the main engines are exposed and not protected, provide guards.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 23 July 2026
Resolved 23 July 2026
09 - Working and Living Conditions › 092 - Working Conditions › Other (accident prevention)
Issued 23 June 2026
Resolved
Where crew may be employed there must be two means of escape. The secondary means of escape from the engine room is blocked by a seat cushion on the bridge. Provide a means to allow free exit and mark to ensure it is not blocked.
Condition: Design Flaw
Action required: 50 - Rectify deficiencies w/in 30 days
Due 23 July 2026
Resolved 23 July 2026
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 24 September 2025
Resolved
Replace dented HAD and install engine/power ventilation shutdowns on installed fire-extinguishing system in the engine room. Current setup on-board is not set up in accordance with the CG approved Manufactures Design, Installation, Operation and Maintenance Manual. Final testing need to be witness By USCG Marine Inspector prior to next operating season.
Action required: 705 - Other - as specified
Due 1 April 2026
Resolved 12 June 2026
Resolution: Vessel is excepted under 46CFR136.110 and compnay removed the CO2 system
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 24 September 2025
Resolved
Replace batteries in both Life ring buoy lights with approved ones.
Action required: 701 - Prior to carriage of passengers/cargo
Due 24 September 2025
Resolved 23 June 2026
05 - Radio Communications › N/A - No Subsystem › Satellite EPIRB 406MHz/1.6GHz
Issued 24 September 2025
Resolved
Replace Expired hydrostatic release on EPRIB,
Action required: 701 - Prior to carriage of passengers/cargo
Due 24 September 2025
Resolved 23 June 2026
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 24 September 2025
Resolved
Vessel must provide records of drills and instruction. Vessel has no logs for 2025 Operational season.
Action required: 701 - Prior to carriage of passengers/cargo
Due 24 September 2025
Resolved 23 June 2026
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 17 September 2024
Resolved
replace life ring buoy light battery with correct approved lithium one prior to going back into the water and operating.
Action required: 705 - Other - as specified
Due 1 April 2025
Resolved 23 June 2025
Resolution: all sat
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 17 September 2024
Resolved
Replace all Expired items in the first aid kit prior to going back into the water and operating.
Action required: 705 - Other - as specified
Due 1 April 2025
Resolved 23 June 2025
Resolution: all sat
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 17 September 2024
Resolved
Vessel’s 2024 log book is missing. Vessel must provide an log book prior to going back into the water and operating
Action required: 705 - Other - as specified
Due 1 April 2025
Resolved 23 June 2025
Resolution: all sat
01 - Certificates & Documentation › 011 - Ships Certificates › Cargo Ship Safety Radio (including exemption)
Issued 17 September 2024
Resolved
Get FCC Bridge to Bridge Cert. prior to going back in the water and operating.
Action required: 705 - Other - as specified
Due 1 April 2025
Resolved 23 June 2025
Resolution: all sat
11 - Life Saving Appliances › N/A - No Subsystem › Immersion suits
Issued 17 September 2024
Resolved
provide 2 immersion suits prior to going back into the water and operating
Action required: 705 - Other - as specified
Due 1 April 2025
Resolved 23 June 2025
Resolution: all sat
05 - Radio Communications › N/A - No Subsystem › Satellite EPIRB 406MHz/1.6GHz
Issued 17 September 2024
Resolved
Replace expired hydrostatic release prior to going back into the water and operating.
Action required: 705 - Other - as specified
Due 1 April 2025
Resolved 23 June 2025
Resolution: all sat
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 14 September 2023
Resolved
Each watertight hatch must be marked on both sides in clearly legible letters at least 25 millimeters (1 inch) high: “WATERTIGHT DOOR—KEEP CLOSED” or “WATERTIGHT HATCH—KEEP CLOSED”. The watertight hatches to the lazerette, machinery space, and forward storage space were not marked. Properly mark watertight hatches.
46 CFR 140.160(e)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 14 October 2023
Resolved 24 October 2023
Resolution: Watertight hatches and doors were properly marked.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 14 September 2023
Resolved
Each entrance to a space storing carbon dioxide cylinders, a space protected by carbon dioxide systems, or any space into which carbon dioxide might migrate must be conspicuously marked: Spaces protected by carbon dioxide—“CARBON DIOXIDE GAS CAN CAUSE INJURY OR DEATH. WHEN ALARM OPERATES, DO NOT ENTER UNTIL VENTILATED. LOCK OUT SYSTEM WHEN SERVICING.” Spaces into which carbon dioxide might migrate — “CARBON DIOXIDE GAS CAN CAUSE INJURY OR DEATH. DISCHARGE INTO NEARBY SPACE CAN COLLECT HERE. WHEN ALARM OPERATES VACATE IMMEDIATELY.” The machinery space and forward storage space were Carbon Dioxide can collect were not marked, properly mark entrances to spaces.
46 CFR 136.110
46 CFR 78.47-11(b)-(c)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 14 October 2023
Resolved 24 October 2023
Resolution: The machinery space and forward storage space were properly marked for carbon dioxide hazards.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 14 September 2023
Resolved
Each ship subject to the Bridge-to-Bridge Act must have on board a radio operator who holds a restricted radiotelephone operator permit or higher class license. The Captain on-board did not have a FCC restricted operator permit of higher class license, obtain FCC radio operator license.
33 CFR 164.72(a)(3)
47 CFR 80.163
31OCT2023: Company Rep is coordinating with mariner to complete required FCC radio licensing.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 14 October 2023
Resolved 10 July 2024
Resolution: Mariner obtained FCC Marine Radio Operator Permit.
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 28 May 2021
Resolved
Vsl doesn't have a desiganted installed fire pump.
Action required: 705 - Other - as specified
Resolved 9 July 2021
Resolution: Rcvd request for excepted status, vessel now not required Fire pump.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 28 May 2021
Resolved
There are exposed wires on he port side aft bulkhead near the overhead.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 September 2021
Resolved 7 July 2021
Resolution: All exposed wire have been capped or removed.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 28 May 2021
Resolved
In the electrical breaker panel on the Port Side near aft bulk head, there are open punch outs. Replace with blanks.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 7 July 2021
Resolution: Punch outs replace with blanks