M/V CECILE A. FITCH is a 1965 towing vessel. The Coast Guard has recorded 28 inspections since 1999, most recently in October 2020, along with 7 deficiencies, 2 operational controls and 3 casualty investigations between 2008 and 2020.
Records from 1999 to 2020. Most recent: inspection, 20 October 2020.
This record may be incomplete: the most recent inspection recorded for this vessel was 6 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Towing Vessel class in Maury's sources begin in 1980.
Every line above is a count of records the US Coast Guard wrote, or a date it recorded.
A blank resolution means none was recorded in this data; it does not establish that a
deficiency is outstanding. Years with a record are calendar years in which a record
exists, not years in service. What Maury does
not do.
Registered dimensions (L × B × D)79.8 ft × 32.1 ft × 9.6 ft
Registered tonnagegross 263 / net 179
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderGREENVILLE MANUFACTURING & MACHINE WORKS · GREENVILLE, MS, UNITED STATES · built 1965
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing portNEW ORLEANS, LA
Trade endorsementsCoastwise, unrestricted
DocumentationExpired · issued 30 June 2004
Service, as the file records itTowing Vessel
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it263 - Regulatory (Subpart C or D), Gross Ton 179 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Vessel history report
Every record for this hull, in one document — $299
Every recorded inspection, 1980 to
2026 for this class, in one chronology · every deficiency, with system, dates
and resolution · operational controls imposed and removed · every name this
hull has been recorded under · the vessels it was inspected alongside, and when
· how its record compares with hulls of similar age and size, as a fact about the
population and never a judgement about this vessel.
This report is in development and is not for sale yet. There is
no date, and nothing is charged. Leave an email and we will tell you when it exists, once.
Used only to tell you when the report exists.
Not shared, not sold, and not added to a mailing list.
The Coast Guard recorded this vessel and the following in the same
inspection activity — normally a tug and the barges in its tow. A recreational or
unclassed hull in the same activity is held and not published, so it does not appear
here: these lists are a floor, not a complete manifest.
All owners and operators of an existing tow vessel must have a valid COI prior to the specified phase-in period. This vessel is the only operating vessel in the fleet and has not obtained a valid COI. The vessel shall be made available for a Coast Guard COI inspection within 90 days. If an inspection is not completed prior to this date, the action for this deficiency shall be changed to a 60(Rectify deficiencies prior to movement) and the vessel may no longer permitted to operate.
Action required: 60 - Rectify deficiencies prior to movement
Resolved 18 May 2022
Resolution: Vessel no longer must apply for COI since it is laid up.
All owners and operators of an existing towing vessel must have a valid COI prior to the specified phase-in-period. This vessel has not obtained a valid COI. The vessel shall be made available for a Coast Guard COI inspection within 90 days. If an inspection is not completed prior to this date, the action for this deficiency shall be changed to a 60 and the vessel may not be permitted to operate.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 8 November 2020
Resolved 20 October 2020
Resolution: COI ISSUED
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 6 August 2020Resolved
Fire detection panel must be installed tested and maintained in accordance with the manufactures design manual. Fire Detection panel has a trouble alarm, power alarm and was showing a fire in zone 2.
Condition: Improper/Lack of Maintenance
Action required: 30 - Ship detained
Due 6 August 2020
Resolved 10 August 2020
Resolution: Owner 3rd party FAST attend vessel to make repairs and certify system. See Documents.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 6 August 2020Resolved
Monthly inspection required by NFPA 10 may be conducted by owner/operator. Several portable fire extinguishers were empty, low on charge and missing.
Condition: Improper/Lack of Maintenance
Action required: 30 - Ship detained
Due 6 August 2020
Resolved 10 August 2020
Resolution: Owner had 3rd party Inspect, fill and replace portable fire extinguishers. See tech report in documents.
An audible and visual alarm must be provided at the operating station for emergency conditions exist in the engine room. When testing the bilge alarm no notification was made to the operating station repeater panel.
Condition: Improper/Lack of Maintenance
Action required: 30 - Ship detained
Due 6 August 2020
Resolved 10 August 2020
Resolution: Ships crew made repairs to the repeater panel, Marine Inspectors satisfactory tested bilge and low hydraulic oil in the steering system.
07 - Fire Safety › N/A - No Subsystem › Fire prevention structural integrity
Issued 6 August 2020Resolved
Fire hazards shall be minimized. Several flammable liquid containers were stores inside the vessel, in bunk rooms in the bathroom closet. Ensure flammable liquids are stores in an approved flame locker with appropriate fire extinguisher nearby.
Condition: Placed in Improper Service
Action required: 30 - Ship detained
Due 6 August 2020
Resolved 10 August 2020
Resolution: Owner installed two approved fire lockers on the back deck with a fire extinguisher nearby. Also removed all the flammable liquids from inside the vessel.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 6 August 2020Resolved
Electrical systems and equipment must function properly and minimize system failures fire and shock hazards. Several loose exposed wires were found. An over current protection box to the port side on the helm was found with empty circuit breaker and no blank allowing access to the bar.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 6 August 2020
Resolved 10 August 2020
Resolution: Wires were removed or made safe.
31 May 2008Routine · role: Involved in a Marine Casualty · activity 3224732
12 December 2009Routine · role: Transiting Vicinity of Primary Subject · activity 3653478
11 February 2020Significant Marine Casualty · role: Involved in a Marine Casualty · serious marine incident, as classified · 2 dead · activity 6907817
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.
Recorded names · 1
BRENDA SUE (2008–2009). Names as the Coast Guard recorded them in incident records, with the years they appear; some are renames and some are spelling variants.
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.